Generac Protector Series Standby Generators

The Generac Protector Series offers reliable standby generators designed for liquid-cooled gaseous engine operation. These units provide essential backup power for homes and businesses.

Standard Features

  • Evolution™ Controller
  • Cellular Connectivity for Mobile Link® and Fleet
  • Padlockable Control Panel Cover
  • Quiet Operation
  • Corrosion Resistant Aluminium Enclosure
  • 5 Year/2,000 Hour Limited Warranty
  • High Motor-Starting, Surge Capacity
  • ±1% Digital Voltage Regulation
  • <5% Total Harmonic Distortion Power Quality
  • Fuel Efficiency
  • Controller-Selectable Fuel Type - Propane or Natural Gas
  • EPA Emissions Certified
  • CA & MA Emissions Compliant Models
  • 115 mph (185 km/h) Wind Speed Rating
  • UL 2200 Listed
  • SwRI Listed & Labeled allowing installation as close as 18 in (457 mm) from structure

Optional Field-Installable Features

  • Push-Button Emergency Stop
  • Cold Weather Operation Heaters

Generator Specifications

Generator Output

VoltageRG04845RG06045RG08045
Power (kW)Current (A)Power (kW)Current (A)Power (kW)Current (A)
PROPANE
120/240 V 1-Phase482006025075312
208/120 V 3-Phase481676020875260
240/120 V 3-Phase481446018075226
480/277 V 3-Phase4872609075113
NATURAL GAS
120/240 V 1-Phase482006025080333
208/120 V 3-Phase481676020880278
240/120 V 3-Phase481446018080241
480/277 V 3-Phase4872609080120

Emergency Standby Power (ESP) Rating: Standby ratings apply to installations served by a reliable utility source. The ESP rating is applicable to varying loads for the duration of a power outage. The average power output over 24 hours shall not exceed 70% of the ESP rating.

Voltage Regulation

TypeDigital
SensingSingle Phase
Regulation±1%

Alternator System

RG04845RG06045RG08045
Circuit Breaker (CB) Size (A)120/240 V 1-Phase200300400
208/120 V 3-Phase175200300
240/120 V 3-Phase150200300
480/277 V 3-Phase80100150
Alternator TypeSynchronous
Rotor Insulation ClassH
Stator Insulation ClassH
Telephone Interference Factor (TIF)<50
BearingsSealed Ball
CouplingFlexible Disc
Excitation SystemDirect
Total Harmonic Distortion<5%

Surge Capacity

Surge Amps at <0.4 Power FactorRG04845RG06045RG08045
15% Voltage Dip (A)30% Voltage Dip (A)15% Voltage Dip (A)30% Voltage Dip (A)15% Voltage Dip (A)30% Voltage Dip (A)
120/240 V 1-Phase100300150413283600
208/120 V 3-Phase118242135313236500
240/120 V 3-Phase144260117289204432
480/277 V 3-Phase6412354122102192

Engine System

RG04845RG06045-RG08045
MakeGeneracGenerac
Model4.5 L Inline 4-Cylinder, Naturally Aspirated4.5 L Inline 4-Cylinder, Turbocharged & Aftercooled
Compression Ratio9.9:18.9:1
Lifter TypeHydraulicHydraulic
Oil Pump TypeGearGear
Oil Filter TypeFull Flow Spin-on CartridgeFull Flow Spin-on Cartridge
Crankcase Capacity (qt (L))12 (11)12 (11)
Temperature Derate1.7% per 10 °F above 77 °F (1.5% per 5 °C above 25 °C)1.7% per 10 °F above 77 °F (1.5% per 5 °C above 25 °C)
Altitude Derate3% per 1,000 ft above 600 ft (1% per 100 m above 183 m)3% per 1,000 ft above 3,000 ft (1% per 100 m above 915 m)
Exercise Speed (rpm)1,5001,500
Operating Speed (rpm)1,8001,800
Exhaust Flow at Rated Output (cfm (m³/min))104 (2.9)181 (5.1)

Governor

TypeElectronic
Frequency RegulationIsochronous

Cooling System

RG04845RG06045-RG08045
Coolant50/50 (50% Ethylene Glycol)
Coolant System Capacity (US gal (L))2.9 (11)4.5 (17)
Water Pump TypeBelt Driven
Fan TypeBelt Driven
Fan Quantity1
Maximum Ambient Air Temperature (°F (°C))122 (50)

Fuel System

Fuel TypesLiquid Propane (LP) Vapor or Natural Gas (NG)
Fuel Type ConfigurationController-Selected Only
LP Vapor Pressure (in H2O (kPa))7-14 (1.74-3.48)
NG Pressure (in H2O (kPa))3.5-14 (0.87-3.48)
Fuel Shutoff SolenoidStandard

Fuel Consumption

Liquid Propane

Rated LoadRG04845RG06045RG08045
(US gph)(L/h)(US gph)(L/h)(US gph)(L/h)
Exercise0.72.60.93.40.93.4
25%2.911.02.17.92.69.8
50%4.215.94.416.75.721.6
75%5.320.16.825.78.331.4
100%6.625.08.431.810.840.9

Propane - 91,452 BTU/US gal (25.5 MJ/L); 36 ft³/US gal (0.27 m³/L); 2,540 BTU/ft³ (94.6 MJ/m³); 4.24 lb/US gal (0.508 kg/L)

Natural Gas

Rated LoadRG04845RG06045RG08045
(cfh)(m³/h)(cfh)(m³/h)(cfh)(m³/h)
Exercise1012.91032.91032.9
25%2015.72577.32928.3
50%3369.543212.253415.1
75%44712.761817.579922.6
100%60717.280822.91,06330.1

Natural Gas - 1,036 BTU/ft³ (38.6 MJ/m³)

See Emissions Data Sheets for maximum fuel flow for EPA and SCAQMD permitting purposes.

Electrical System

System Voltage (V)12
Charge Alternator (A)35
Battery Charger (A)2.5
Recommended Battery (not included)Flooded Lead Acid, Group 27, 600 CCA Minimum
Maximum Battery SizeFlooded Lead Acid, Group 31, 750 CCA Minimum

Enclosure

RG04845RG06045RG08045
Sound Level at Exercise Speed (dB(A) @ 23 ft [7 m])686868
Wind Speed Rating (mph (km/h))115 (185)115 (185)115 (185)
ColorBisque

Controller Features

  • Two-Line Plain Text LCD: Simple user interface for ease of operation.
  • Multi-Lingual: Supports English, French, Spanish, and Portuguese.
  • Mode Switch: AUTO (Automatic Start on Utility failure. 7 day exerciser.), OFF (Stops unit. Power is removed. Control and charger still operate.), MANUAL (Start with starter control, unit stays on. If utility fails, transfer to load takes place.)
  • Programmable start delay: Between 10 - 30 seconds (Standard 10 sec)
  • Engine Start Sequence: Cyclic cranking: 16 sec on, 7 sec rest (90 sec maximum duration)
  • Engine Warm-up: 5 sec
  • Engine Cool-Down: 1 min
  • Starter Lock-out: Starter cannot re-engage until 5 sec after engine has stopped.
  • Smart Battery Charger: Standard
  • Automatic Voltage Regulation with Over and Under Voltage Protection: Standard
  • Automatic Low Oil Pressure Shutdown: Standard
  • Overspeed Shutdown: Standard, 72 Hz
  • High Temperature Shutdown: Standard
  • Overcrank Protection: Standard
  • Safety Fused: Standard
  • Failure to Transfer Protection: Standard
  • Low Battery Protection: Standard
  • 50 Event Run Log: Standard
  • Future Set Capable Exerciser: Standard
  • Incorrect Wiring Protection: Standard
  • Internal Fault Protection: Standard
  • Common External Fault Capability: Standard
  • Governor Failure Protection: Standard

Available Accessories

Control System Kits

  • Generac Generator Connectivity Accessory, Cellular (GGCAC): Provides cellular connection for monitoring via Mobile Link and Fleet.
  • Enclosure Mounted Emergency Stop Kit: Red push button switch replacing the generator emergency shutdown rocker switch.
  • Remote Emergency Stop Kit, Surface Mount: Red push button switch with twist release, in an aluminum enclosure, mounts remotely.
  • Remote Emergency Stop Kit, Flush Mount: Red push button switch with twist release, in a flush-mount aluminum enclosure.
  • Remote Emergency Stop Kit, Break Glass: Spring-loaded switch behind breakable glass in an aluminum enclosure, mounts remotely.
  • Generac Load Manager, 50 A: Optimizes generator performance by managing large electrical loads upon startup and shed.
  • Generac Load Manager, 100 A: Optimizes generator performance by managing large electrical loads upon startup and shed.
  • Generac LTE Propane Tank Fuel Level Monitor: Connects to 4G LTE cellular service to measure and report LP fuel levels.

Operating Environment Kits

  • Battery Heater Kit: Recommended for temperatures below 32 °F (0 °C), externally powered by 120 VAC, 60 Hz.
  • Engine Block Heater Kit: Recommended for temperatures below 0 °F (-18 °C), externally powered by 120 VAC, 60 Hz.

Installation Kits

  • Base Plug Kit: Plugs for baseframe lifting holes to keep debris out.

Maintenance Kits

  • 4.5 L Gaseous Engine Regular Maintenance Kit: Includes oil filter, oil funnel, air filter, and spark plugs.
  • Bisque Paint Kit: For touching up generator enclosure paint.

Installation Drawings Summary

Detailed installation drawings are provided for the 48 kW and 60/80 kW models. These drawings illustrate overall dimensions, component locations (e.g., air intake, exhaust, oil fill, battery, control panel access), and mounting details. Key notes cover concrete pad requirements (e.g., minimum size and offset), service access, ventilation requirements (fresh air intake, discharge air), and compliance with applicable NFPA standards. Specific dimensions for various views (top, side, rear) are provided in millimeters and inches.

PDF preview unavailable. Download the PDF instead.

Generac-48kw-60kw-80kw-specsheet - 2024 Microsoft: Print To PDF

Related Documents

Preview Generac RG Protector Series Standby Generators: Specifications and Installation Details
Comprehensive specifications, features, and installation drawings for Generac RG Protector Series Standby Generators, including models RG04845, RG06045, and RG08045. Covers engine, fuel, electrical, and enclosure details, plus installation guidance.
Preview Generac Standby Generators: Reliable Home & Small Business Backup Power
Explore Generac's range of home and commercial standby generators, including PowerPact, Guardian Series, and Protector Series. Discover features like Mobile Link, TruePower Technology, and various coverage options for uninterrupted power.
Preview Generac Generators: Automatic Standby and Portable Power Solutions
Explore Generac's comprehensive range of automatic standby and portable generators, designed to provide reliable power for homes and businesses. Learn about features, specifications, coverage options, and the Generac Promise for peace of mind during power outages.
Preview Generac Generators: Portable, Residential, and Commercial Solutions
Explore Generac's comprehensive range of generators, including portable, residential standby, and commercial standby systems. Learn about features, specifications, and applications for reliable power solutions.
Preview Generac Guardian Series Standby Generators: Features, Specifications, and Data
Explore the Generac Guardian Series of liquid-cooled gas engine standby generators. This document details features, technical specifications, operating data, and installation layouts for models QT025, QT030, QT045, and QT060.
Preview Generac RG Protector Series Liquid-Cooled Standby Generators: Specifications
Detailed specifications for Generac RG Protector Series liquid-cooled gaseous standby generators, covering models from 22 kW to 60 kW. Includes features, technical data, engine specifications, fuel consumption, electrical system details, enclosure information, controller features, and available accessories.
Preview Generac Commercial Generators 22-150 kW: Reliable Standby Power Solutions
Generac offers a comprehensive range of commercial standby generators from 22-150 kW, providing reliable backup power for businesses. This document details product features, applications, transfer switches, controllers, accessories, and ordering information, emphasizing business continuity and operational resilience.
Preview Generac Generators: Automatic Standby and Portable Power Solutions
Explore Generac's comprehensive range of automatic standby and portable generators designed to provide reliable power for homes and businesses during outages. Discover features, benefits, and specifications for peace of mind.