Image: A Generac commercial standby generator unit, typically a large, rectangular, weather-resistant enclosure, installed outdoors.
Generac was the first manufacturer to recognize that commercial businesses would benefit from the affordable backup power a natural gas or LP generator provides, revolutionizing the commercial standby market. Previously, generators powerful enough for commercial use were expensive, diesel-configured systems. By offering a broad range of commercial options, Generac has made reliable backup power accessible to thousands of businesses. Units are readily available in single and three-phase, LP, and natural gas options, ensuring businesses can operate without interruption from the dangers and costly effects of power outages.
Natural gas and liquid propane (LP) offer significant benefits for backup power:
Power outages pose a significant threat to businesses. Every year, over two million U.S. businesses experience outages lasting eight hours or more. The U.S. Department of Energy estimates that power outages cost $80 billion annually, with 98% of these losses originating from the business sector.
Financially, power failures can lead to substantial losses. For instance, when IT systems are disrupted:
Business | Lost Sales per Hour* | Typical kW | Approximate Generator Cost Installed | Payback Hours |
---|---|---|---|---|
Convenience store / gas station | $556 | 100 | $26,828 | 48 |
High-volume restaurant | $881 | 150 | $37,000 | 42 |
Drug store | $1,750 | 150 | $37,000 | 21 |
Supermarket | $4,388 | 300 | $80,779 | 18 |
*Does not include the costs of damage or inventory losses.
Beyond lost revenue, power outages incur direct costs and intangible losses:
Image: A commercial gas station canopy at night, illuminated, with fuel pumps visible.
Generac's commercial generators, ranging from 22-150 kW, are available in single and three-phase options and back up an extensive range of businesses. Common applications include:
Image: A Generac commercial standby generator unit, typically a large, rectangular, weather-resistant enclosure, installed outdoors.
For homeowners with larger residences, a higher kW unit may be necessary for whole-house coverage, including amenities like additional living areas, garages, air conditioners, pools, greenhouses, mother-in-law suites, and critical home medical care. Commercial generators can provide the required kW.
For residential and smaller business applications requiring less power, Generac's Guardian® Series starts at 8 kW. Contact a Generac representative or visit generac.com for more information.
Many businesses can continue serving customers during power outages, not only preventing revenue loss but also providing essential services:
Image: A commercial building facade, possibly a retail store or restaurant, with prominent signage.
Generac's commercial generators are designed for quiet operation, durability in severe weather, and ease of ownership.
Images: Two Generac generators of different sizes (60 kW and 45 kW).
This system uses a process that evenly joins paint particles to every part of the metal surface. Components are baked to form a lasting bond for superior protection against the elements, ensuring consistent coverage on the enclosure and base frame.
All automatic standby generators perform a weekly self-diagnostic test. Generac's patented, programmable Quiet-Test mode offers an ultra-quiet, neighborhood-friendly self-test, available on 22-150 kW models.
Choose from premium all-weather aluminum or sturdy galvanneal steel enclosures with RhinoCoat:
Provides easy monitoring and management of generator functions, supporting remote monitoring with an LCD display, keypad, and alarm log.
Image: A close-up of the Generac Nexus™ controller interface with an LCD display and keypad.
Generac designs and manufactures a complete line of automatic transfer switches (ATS) to meet the requirements of virtually any emergency standby power application. Generac transfer switches are known for outstanding quality, performance, and competitive pricing.
Image: Two technicians wearing hard hats and safety glasses working inside an electrical panel, installing components.
Engineered with Generac's Digital Load Management (DLM) technology, the Nexus Smart Switch is designed to cycle on and off air conditioners without additional components, allowing a smaller generator to cover more circuits. It supports up to 400 Amp service, NEMA 3R outdoor-rated enclosures, and can cover every circuit when paired with a higher kW generator.
Images: Generac Nexus Smart Switch™ unit and a DLM Module.
With a built-in 16-circuit load center, the Nexus LTS is ideal for managing more than six large loads. It is 200 Amp, service rated, and features an aluminum NEMA 3R outdoor-rated enclosure.
Image: Generac Nexus™ LTS unit.
RTS transfer switches are suitable for applications requiring up to 400 Amps. They support various phase and voltage configurations (100-800 Amp, three-phase 120/208, 120/240, 277/480; 600-800 Amp, single-phase 120/240). They are compatible with generators up to 150 kW, integrate with the Nexus controller, and CSA-approved models are available.
Images: Examples of CSA models RTS-D, J and RTS-X, RTS-N models.
Digital controls enhance generator system functionality, overseeing the transfer switch and operation. They track oil pressure, coolant levels, and voltage. Generac designs its own digital controls for superior reliability and system integration, incorporating a sealed connection point philosophy for durability and long-life protection against corrosion, vibration, moisture, EMI/RFI, dust, and static discharge.
Expanded features create an improved user interface for monitoring and managing generator functions on liquid-cooled models (22-150 kW). These controllers include many features and alarms previously available only on larger models.
FEATURES | BENEFIT |
---|---|
LCD display and keypad | Improved user interface. Provides accurate, real-time readings to owner and service contractor. |
Remote monitoring capabilities | Provides wireless capabilities to easily connect with a Generac in-home remote monitor. |
Time & date | Assures speed and accuracy in maintaining key aspects of user interface, such as scheduled maintenance and exercise cycles. |
Alarm log | Provides accurate means of tracking both scheduled and unscheduled run time events that could affect maintenance, service, and product life. |
Run log | Maintains readings of run time in exercise cycles and use related to outages for improved accuracy in scheduling maintenance and determining product life. |
Set exercise via display | Simple, easy-to-use control set-up allows the owner to easily change the time of exercise. |
Engine hours display | Provides accurate run times to help assure proper maintenance intervals are maintained. |
RPM and frequency displays | Hastens service diagnosis and provides immediate operation data at installation. |
Low fuel pressure indication | Helps to assure correct installation of fuel source at start-up. |
Dry contacts | A dry set of contacts allow for additional alert capability during shutdowns. |
Check generator status wirelessly from inside your home. Features visual and audio alerts for maintenance or low battery. It is small, compact, and magnetically backed for mounting.
Remotely control generator functions with an LCD display. Allows remote testing, setting exercise cycles, and maintenance reminders. AC powered with battery backup, it can be desk or wall mounted. View generator events, faults, warnings, voltage, frequency, and graphing capabilities.
Consists of a battery warmer with an automatically controlled thermostat, recommended for areas where temperatures drop below 32° F for extended periods.
Ensures the generator system is always in top operating condition and warranty requirements are met. Includes block heaters and associated mounting hardware.
Manage up to four additional large 240V loads by adding individual DLM modules to your Nexus Smart Switch™. These 50-amp modules are housed in a NEMA 3R enclosure for indoor or outdoor installation.
Model | Amps | Service Rated | Voltage | Phase | Enclosure Rating | Enclosure Material | Dimensions (H" x W" x D") | Weight (lbs) | UL Listed | CUL Listed |
---|---|---|---|---|---|---|---|---|---|---|
RTSX100A3 | 100 | No | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 20 x 14.6 x 7.1 | 20 | Yes | Yes |
RTSD100A3 | 100 | Yes | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 20 x 14.6 x 7.1 | 22.5 | Yes | No |
RTSD150A3 | 150 | Yes | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 30 x 13.5 x 7.1 | 39 | Yes | No |
RTSX200A3 | 200 | No | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 20 x 14.6 x 7.1 | 20 | Yes | Yes |
RTSD200A3 | 200 | Yes | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 30 x 13.5 x 7.1 | 39 | Yes | No |
RTSJ200A3 | 200 | Yes | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 42.3 x 20.1 x 7.9 | 80 | Yes | Yes |
RTSX400A3 | 400 | No | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 48 x 21.8 x 10.1 | 133 | Yes | Yes |
RTSD400A3 | 400 | Yes | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 48 x 21.8 x 10.1 | 140 | Yes | Yes |
RTSE100A3CSA | 100 | Yes - CSA | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 20 x 14.6 x 7.1 | 21 | No | Yes - CSA |
RTSE200A3CSA | 200 | Yes - CSA | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 30 x 16 x 7.1 | 38.5 | No | Yes - CSA |
Model | Amps | Service Rated | Voltage | Phase | Enclosure Rating | Enclosure Material | Dimensions (H" x W" x D") | Weight (lbs.) | UL/CUL Listed |
---|---|---|---|---|---|---|---|---|---|
RTSN100G3 | 100 | No | 208V, 3-pole | 3ø | NEMA 3R | Aluminum | 24.1 x 20.2 x 7.1 | 20 | Yes |
RTSN100K3 | 100 | No | 480V, 3-pole | 3ø | NEMA 3R | Aluminum | 36.1 x 20.2 x 10.0 | 105 | Yes |
RTSN100J3 | 100 | No | 240V, 3-pole | 3ø | NEMA 3R | Aluminum | 24.1 x 20.2 x 7.1 | 53 | Yes |
RTSN200G3 | 200 | No | 208V, 3-pole | 3ø | NEMA 3R | Aluminum | 24.1 x 20.2 x 7.1 | 20 | Yes |
RTSN200K3 | 200 | No | 480V, 3-pole | 3ø | NEMA 3R | Aluminum | 48.1 x 30.1 x 13.1 | 110 | Yes |
RTSN200J3 | 200 | No | 240V, 3-pole | 3ø | NEMA 3R | Aluminum | 24.1 x 20.2 x 7.1 | 53 | Yes |
RTSN400G3 | 400 | No | 208V, 3-pole | 3ø | NEMA 3R | Aluminum | 36.1 x 24.0 x 10 | 133 | Yes |
RTSN400K3 | 400 | No | 480V, 3-pole | 3ø | NEMA 3R | Steel | 48 x 24.0 x 10 | 133 | Yes |
RTSN400J3 | 400 | No | 240V, 3-pole | 3ø | NEMA 3R | Aluminum | 36.1 x 24.0 x 10 | 133 | Yes |
RTSN600A3 | 600 | No | 240V, 2-pole | 1ø | NEMA 3R | Aluminum | 66.0 x 36.0 x 21.0 | 439 | Yes |
RTSN600G3 | 600 | No | 208V, 3-pole | 3ø | NEMA 3R | Steel | 66.0 x 36.0 x 21.0 | 439 | Yes |
RTSN600K3 | 600 | No | 480V, 3-pole | 3ø | NEMA 3R | Steel | 66.0 x 36.0 x 21.0 | 439 | Yes |
RTSN600J3 | 600 | No | 240V, 3-pole | 3ø | NEMA 3R | Steel | 66.0 x 36.0 x 21.0 | 439 | Yes |
RTSN800A3 | 800 | No | 240V, 2-pole | 1ø | NEMA 3R | Steel | 66.0 x 36.0 x 21 | 469 | Yes |
RTSN800G3 | 800 | No | 208V, 3-pole | 3ø | NEMA 3R | Steel | 66.0 x 36.0 x 21 | 469 | Yes |
RTSN800K3 | 800 | No | 480V, 3-pole | 3ø | NEMA 3R | Steel | 66.0 x 36.0 x 21 | 469 | Yes |
RTSN800J3 | 800 | No | 240V, 3-pole | 3ø | NEMA 3R | Steel | 66.0 x 36.0 x 21 | 469 | Yes |
QT02224 | QT02515 | QT02724 | QT03015 | QT03624 | QT04524 | QT04854 | QT06024 | QT07068 | QT08046 | QT10068 | QT13068 | QT15068 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Rated Power LP | 22 kW | 25 kW | 27 kW | 30 kW | 36 kW | 45 kW | 48 kW | 60 kW | 67 kW | 80 kW | 100 kW | 130 kW | 150 kW |
Rated Power NG | 22 kW | 25 kW | 25 kW | 30 kW | 35 kW | 45 kW | 48 kW | 60 kW | 64 kW | 80 kW | 89 kW | 130 kW | 150 kW |
Amps @ 240V, 1ø LP/NG | 92 | 104 | 112/104 | 125 | 150/146 | 188 | 200 | 250 | 279/267 | 320 | 417/371 | 542/488 | 600/567 |
Amps @ 208V, 3ø LP/NG | 76 | 87 | 94/87 | 104 | 125/121 | 156 | 166 | 208 | 243*/232* | 278 | 347/326 | 451/423 | 520/493 |
Amps @ 240V, 3ø LP/NG | 66 | 75 | 81/75 | 90 | 108/105 | 135 | 144 | 180 | 210*/201* | 249 | 301/283 | 391/367 | 451/427 |
Amps @ 480V, 3ø LP/NG | N/A | N/A | N/A | N/A | 54/52 | 68 | 72 | 90 | 105*/101* | 120 | 151/141 | 195/183 | 225/214 |
Engine/Alternator RPM | 1800/1800 | 3600/3600 | 1800/1800 | 3600/3600 | 1800/1800 | 3600/3600 | 1800/1800 | 3600/3600 | 1800/1800 | 3600/3600 | 2300/1800 | 3000/1800 | 3600/3600 |
Engine Size | 2.4L | 1.5L | 2.4L | 1.5L | 2.4L | 2.4L | 5.4L | 2.4L | 6.8L | 4.6L | 6.8L | 6.8L | 6.8L |
Cylinder Arrangement | In-line 4 | In-line 4 | In-line 4 | In-line 4 | In-line 4 | In-line 4 | V-8 | In-line 4 | V-10 | V-8 | V-10 | V-10 | V-10 |
Fuel Consumption LPG | 125 (3.4) | 172 (4.7) | 143 (3.9) | 197 (5.4) | 200 (5.5) | 290 (8.0) | 302 (7.96) | 327 (9.0) | 411 (11.17) | 465 (12.78) | 507 (13.9) | 719 (19.8) | 830 (22.57) |
Fuel Consumption NG | 316 | 430 | 359 | 492 | 503 | 730 | 756 | 862 | 1020 | 1154 | 1260 | 1786 | 2061 |
Quiet-Test Low Speed Mode | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
db(A) at Exercise | 61 | 59 | 61 | 59 | 58 | 61 | 63 | 65 | 61 | 64 | 61 | 65 | 66 |
db(A) at Normal Operating Load | 70 | 72 | 70 | 73 | 64 | 73 | 68 | 72 | 65 | 74 | 72 | 75 | 79 |
Transfer Switch Type Needed | RTS | RTS | RTS | RTS | RTS | RTS | RTS | RTS | RTS | RTS | RTS | RTS | RTS |
Enclosure Material | Aluminum | Steel | Aluminum | Steel | Aluminum | Steel | Aluminum | Steel or Alum** | Aluminum | Aluminum | Aluminum | Aluminum | Aluminum |
Enclosure Color | Grey | Bisque | Grey | Bisque | Grey | Bisque | Grey | Bisque | Bisque | Bisque | Bisque | Bisque | Bisque |
Dimensions (L" x W" x H") | 62.2 x 29 x 33.5 | 62.2 x 29 x 33.5 | 62.2 x 29 x 33.5 | 62.2 x 29 x 33.5 | 77 x 33.5 x 45 | 77 x 33.5 x 45 | 77 x 33.5 x 45 | 77 x 33.5 x 45 | 96.5 x 37 x 48 | 116 x 37 x 55 | 116 x 37 x 55 | 116 x 37 x 55 | 116 x 37 x 5 |
Generator Weight Steel (lbs.) | N/A | 875 | N/A | 935 | N/A | 1414 | N/A | 1441 | N/A | N/A | N/A | N/A | N/A |
Generator Weight Aluminum (lbs.) | 843 | N/A | 891 | N/A | 1271 | N/A | 1516 | 1324 | 2040 | 2075 | 2531 | 2699 | 2492 |
* For 70 kW / 68 kW. ** For complete ordering options, review the Product Selection Guide.
To determine the correct product codes for a Commercial liquid-cooled generator and transfer switch, follow the steps below. A product code is required to order. Contact your inside sales representative or order online. Freight is FOB factory.
STEP 1 kW Ratings e.g. (45 kW = 045) |
STEP 2 Engine e.g. (6.8L = 68) |
STEP 3 Voltage 120/240 1ø = A 120/208 3ø = G 120/240 3ø = J 277/480 3ø = K |
STEP 4 Fuel Natural Gas = N Propane Vapor = V Field Convertible to LP = * |
STEP 5 Enclosure Steel = S Aluminum = A |
STEP 6 Emission/Catalytic Converter No Catalyst = X1 Catalyst & A/F Ratio = C2 |
---|---|---|---|---|---|
22 | 2.4L @ 1800 RPM | A,G,J | N* | A | X |
25 | 1.5L @ 3600 RPM | A,G,J | N* | S | X |
27 | 2.4L @ 1800 RPM | A,G,J | N* | A | X |
30 | 1.5L @ 3600 RPM | A,G,J | N* | S | X |
363 | 2.4L @ 1800 RPM | A, G, J, K | N* | A | X |
45 | 2.4L @ 3600 RPM | A, G, J, K | N* | S | X, C |
48 | 5.4L @ 1800 RPM | A, G, J, K | N* | A | X, C |
603 | 2.4L @ 3600 RPM | A, G, J, K | N, V | S, A | X |
70 | 6.8L @ 1800 RPM | A, G, J, K | N, V | A | X, C |
803 | 4.6L @ 3600 RPM | A, G, J, K | N, V | A | X |
100 | 6.8L @ 2300 RPM Gear Drive | A, G, J, K | N, V | A | C |
130 | 6.8L @ 3000 RPM Gear Drive | A, G, J, K | N, V | A | C |
150 | 6.8L @ 3600 RPM | A, G, J, K | N, V | A | C |
Sample Product Code: QT06024GNSX
STEP 1 Selection Criteria Transfer Switch Used With Generator Controller R Controller or Nexus Controller = RTS |
STEP 2 Switch Type DLM Load Shedding = X1 Service Entrance Rated DLM Load Shedding = D1 16 Circuit Load Shedding = J2 All 3ø = N |
STEP 3 Amp Rating e.g. (200 Amp = 200) |
STEP 4 Voltage 120/240 1ø = A 120/208 3ø = G 120/240 3ø = J 277/480 3ø = K3 |
STEP 5 Enclosure Type NEMA 3R = 3 |
|
---|---|---|---|---|---|
For Standby Generators 22 - 150 kW |
RTS | X, D, J, N | 100, 1504, 200, 400, 600, 800 |
A, G, J, K | 3 |
Sample Product Number: RTSX200A3
Notes:
Important: There are no returns, changes, or cancellations on Generac Commercial Series orders. This equipment is built-to-order once payment is received.
Image: A row of commercial buildings, including a hardware store and a restaurant, with parking lots.
Generac is committed to providing customers with unsurpassed after-the-sale service and support. Their nationwide dealer network has factory-trained technicians and maintains large inventories of Generac parts, components, and accessories. A state-of-the-art training center ensures technicians are up-to-date on product innovations and improvements, receiving comprehensive training and hands-on experience. Generac's commitment includes scheduled maintenance programs, warranty assistance, and emergency service.
For over 50 years, Generac Power Systems has led the industry with innovative design and superior manufacturing. Their sole focus has been standby power, resulting in durable and reliable products. Generac designs and builds its own air-cooled engines, alternators, control systems, automatic transfer switches, enclosures, and base tanks. Vertical integration allows control over quality and material flow. Products are fully integrated power systems and factory tested before shipment. Generac is the name that home and business owners trust.
Image: Two men, one in a suit and the other in work clothes, examining a large metal component in a factory setting.
![]() |
Generac Guardian Series 16/20/22 kW Residential Standby Generators | Features & Specifications Explore the Generac Guardian Series 16, 20, and 22 kW residential standby generators. Learn about True Power™ technology, Evolution™ controls, transfer switch options, and detailed specifications for reliable home backup power. |
![]() |
Generac Standby Generators for Residential & Small Business: Reliable Backup Power Solutions Explore Generac's comprehensive range of automatic standby generators designed for homes and small businesses. Learn about the benefits of backup power, different generator series (CorePower, Guardian, EcoGen, QuietSource), sizing options, transfer switches, and essential accessories. Ensure uninterrupted power during outages with Generac's reliable and efficient solutions. |
![]() |
Generac Generators: Automatic Standby & Portable Power Solutions Explore Generac's comprehensive range of automatic standby and portable generators, designed for reliable home backup, commercial use, and emergency power. Learn about OHVI engines, sizing, features, and choosing the right system. |
![]() |
Generac Guardian Series Automatic Home Standby Generators 10-22 kW Generac Guardian Series automatic home standby generators offer 10-22 kW power with True Power Technology, Mobile Link wireless monitoring, G-Force engines, and durable aluminum enclosures for reliable home backup power. |
![]() |
Generac Generators: Portable, Residential, and Commercial Solutions Explore Generac's comprehensive range of generators, including portable, residential standby, and commercial standby systems. Learn about features, specifications, and applications for reliable power solutions. |
![]() |
Generac Generators: Automatic Standby & Portable Power Solutions Explore Generac's comprehensive range of automatic standby and portable generators, designed to provide reliable power for homes and businesses. Learn about features, specifications, coverage options, and the Generac Promise. |
![]() |
Generac 60 Hz Air-Cooled Generators Owner's Manual (10-24 kW) Comprehensive owner's manual for Generac 60 Hz air-cooled standby generators, covering operation, maintenance, safety, and troubleshooting for models ranging from 10 kW to 24 kW. |
![]() |
Generac 60 Hz Air-Cooled Generator Owner's Manual (10 kW - 24 kW) Comprehensive owner's manual for Generac 60 Hz Air-Cooled Generators (10 kW to 24 kW), covering safety, operation, maintenance, and troubleshooting. Includes detailed specifications and operational guidance. |