Fujitsu Inverter Room Air Conditioner Operating Manual

Model: Wall Mounted Type, Heat & Cool Model (Reverse Cycle)

Indoor Unit Models: ASBA24LFC, ASBA30LFC

Outdoor Unit Models: AOBR24LFL, AOBR30LFT

Safety Precautions

DANGER!

CAUTION!

Features and Functions

WIRED REMOTE CONTROLLER (OPTION): An optional wired remote controller (model No. : UTB-YUD) is available, offering additional functions like a weekly timer and temperature set-back timer. It cannot be used simultaneously with the wireless remote controller.

Name of Parts

Diagrams illustrate the indoor unit, outdoor unit, and remote controller, identifying key components such as the operating control panel, indicators, intake grille, air filters, louvers, drain hose, intake port, outlet port, and remote controller buttons.

Preparation

Load Batteries: Insert AAA R03/LR03 batteries into the remote controller, ensuring correct polarity. Close the battery compartment lid.

Set the Current Time: Press the CLOCK ADJUST button, then use the TIMER SET buttons ( / ) to adjust the time. Press CLOCK ADJUST again to complete the setting.

To Use the Remote Controller: Point the controller at the signal receiver. The operating range is about 7 meters. A beep confirms signal reception.

Remote Controller Holder: Instructions are provided for mounting the holder and inserting/removing the remote controller.

Operation

To Select Mode Operation: Press START/STOP to begin operation. Press MASTER CONTROL to cycle through AUTO, COOL, DRY, HEAT, and FAN modes.

To Set the Thermostat: Use the SET TEMP. buttons ( / ) to adjust the desired temperature. The setting range varies by mode (18-30°C for AUTO/Cooling/Dry, 16-30°C for Heating).

To Set the Fan Speed: Press the FAN CONTROL button to cycle through AUTO, HIGH, MED, LOW, and QUIET speeds. Fan speed behavior varies by mode.

SUPER QUIET Operation: Select QUIET for reduced airflow and quieter operation. Note that this mode is not available during Dry mode and may reduce heating/cooling performance.

To Stop Operation: Press the START/STOP button.

About AUTO CHANGEOVER Operation: The unit automatically selects the operating mode based on room conditions. It may take time to reach the set temperature.

About Mode Operation: Detailed descriptions are provided for Heating, Cooling, Dry, and Fan modes, including specific operational characteristics and temperature considerations.

Timer Operation

To Use the ON timer or OFF timer: Press START/STOP, then TIMER MODE to select CANCEL, OFF, ON, or PROGRAM. Use TIMER SET buttons to adjust the time. The TIMER Indicator Lamp will light.

To Use the Program timer: Set ON and OFF times using the TIMER MODE button. The unit can sequence OFF → ON or ON → OFF operations within a 24-hour period.

To Cancel the Timer: Use the TIMER MODE button to select CANCEL.

To Change Timer Settings: Follow the steps for setting the timer and select the desired mode.

To Stop Air Conditioner Operation while the Timer is Operating: Press the START/STOP button.

To Change Operating Conditions: After setting the timer, press the appropriate buttons to change mode, fan speed, etc.

Sleep Timer Operation

The SLEEP timer automatically adjusts the thermostat setting to prevent excessive warming or cooling during sleep. The unit stops automatically when the set time has elapsed.

To Use the SLEEP Timer: Press the SLEEP button. The OPERATION Indicator Lamp and TIMER Indicator Lamp will light.

To Cancel the Timer: Use the TIMER MODE button to select CANCEL.

To Change the Timer Settings: Press the SLEEP button again and use the TIMER SET buttons.

To Stop the Air Conditioner During Timer Operation: Press the START/STOP button.

Manual Auto Operation

Use the MANUAL AUTO button on the main unit control panel when the remote controller is lost or unavailable. Operation will be under the AUTO mode with a standard fan speed and thermostat setting (24°C).

Adjusting the Direction of Air Circulation

Vertical Air Direction Adjustment: Use the SET button (Vertical) to adjust the up/down airflow direction. The direction is set automatically based on the selected mode (horizontal for Cooling/Dry, downward for Heating).

Horizontal Air Direction Adjustment: Use the SET button (Horizontal) to adjust the left/right airflow direction.

Note: Never insert fingers or foreign objects into the outlet ports. Always use the remote controller's SET button for adjustments.

Swing Operation

To select SWING Operation: Press the SWING button. The SWING Display will light. Cycle through Up/down swing, Left/right swing, and Up/down/left/right swing operations.

To stop SWING Operation: Press the SWING button and select STOP.

About Swing Operation: Descriptions detail how the louvers move for different swing types and airflow directions.

Coil Dry Operation

To select COIL DRY Operation: Press the COIL DRY button. The COIL DRY Display will light. The operation runs for 20 minutes and stops automatically.

To cancel COIL DRY Operation: Press the START/STOP button.

About COIL DRY Operation: This function helps prevent mold and bacteria but does not sterilize.

Cleaning and Care

CAUTION! Always turn off and disconnect the power supply before cleaning. Ensure the intake grille is securely installed.

Cleaning the Intake Grille: Remove the grille, clean with water, and replace.

Cleaning the Air Filter: Open the intake grille, remove the air filter, clean with a vacuum cleaner or by washing, and allow to dry thoroughly. Clean every two weeks.

Air Cleaning Filter Installation: Instructions for installing standard and air cleaning filters are provided.

Replacing dirty Air cleaning filters: Specific filter models (POLYPHENOL CATECHIN AIR CLEANING FILTER: UTR-FA13-1, Negative air ions deodorizing filter: UTR-FA13-2) are mentioned for replacement.

Maintenance of Deodorizing Filters: Clean deodorizing filters every three months by flushing with high-pressure hot water and drying.

Troubleshooting

The manual provides a table of symptoms and potential problems, along with checks to perform before requesting service. Common issues include:

If problems persist, stop operation, disconnect power, and consult authorized service personnel.

Operating Tips

Operation and Performance: The air conditioner uses a heat-pump principle. Heating performance may be reduced in cold weather. Heat-pump units recirculate air, so the room takes time to heat up.

Microcomputer-controlled Automatic Defrosting: During low temperatures and high humidity, frost may form on the outdoor unit. The unit will temporarily stop and defrost automatically. The OPERATION Indicator Lamp will flash during this process.

AUTO Restart: In case of power interruption, the air conditioner will restart automatically in its previous mode when power is restored. If a power failure occurs during timer operation, the timer may reset.

Temperature and Humidity Range: Recommended operating ranges for Cooling, Dry, and Heating modes are provided. Using the unit outside these ranges may cause damage or reduced performance.

Specifications

Detailed specifications are provided for the indoor and outdoor units, including model numbers, type, power requirements, cooling and heating capacity, power input, current, energy efficiency ratio, airflow, maximum pressure, refrigerant type, dimensions, and weight.

PDF preview unavailable. Download the PDF instead.

OM 9315345318-03 En Acrobat Distiller 7.0 (Windows)

Related Documents

Preview Fujitsu Halcyon Room Air Conditioner Operating Manual
This manual provides operating instructions for the Fujitsu Halcyon Inverter Room Air Conditioner, Wall Mounted Type, Heat & Cool Model (Reverse Cycle). It covers features, preparation, operation modes, timer functions, troubleshooting, and specifications for models ASU18RLXS, ASU24RLXS, ASU30RLX, AOU18RLXS, AOU24RLXS, and AOU30RLX.
Preview Fujitsu Halcyon Room Air Conditioner Operating Manual
Comprehensive operating manual for Fujitsu Halcyon wall-mounted room air conditioners (ASU9RQ, ASU12RQ, AOU9RQ, AOU12RQ), covering features, operation, maintenance, and troubleshooting.
Preview Fujitsu ASYA12LCC AOYR12LCC Split Type Air Conditioner Service Manual
Comprehensive service manual for Fujitsu split type, wall-mounted room air conditioners, models ASYA12LCC and AOYR12LCC. Includes specifications, diagrams, error codes, disassembly instructions, parts lists, and accessories.
Preview Fujitsu Split Type Room Air Conditioner Service Manual
Comprehensive service manual for Fujitsu split type room air conditioners, covering models ASYA14LCC, AOYR14LCC, ASYA14LCL, ASYA18LCC, AOYR18LCC, and AOYR18LCL. Includes specifications, diagrams, error codes, and parts lists.
Preview Fujitsu ASYG14LECA Room Air Conditioner Service Manual
This service manual provides detailed specifications, dimensions, refrigerant system diagrams, circuit diagrams, error detection codes, and parts lists for the Fujitsu ASYG14LECA Room Air Conditioner (Wall Mounted Type).
Preview Fujitsu ASYA18LEC / AOYR18LEC Split Type Room Air Conditioner Service Manual
This service manual provides detailed specifications, diagrams, error codes, and parts lists for the Fujitsu ASYA18LEC indoor unit and AOYR18LEC outdoor unit, split-type room air conditioners.
Preview Fujitsu ASYG07LMCE/ASYG09LMCE Wall Mounted Air Conditioner Service Manual
Comprehensive service manual for Fujitsu split type wall-mounted air conditioners, models ASYG07LMCE and ASYG09LMCE. Includes specifications, dimensions, refrigerant system diagram, circuit diagrams, error detection codes, and detailed parts lists for both indoor and outdoor units.
Preview Fujitsu Wall Mounted Air Conditioner Design & Technical Manual for Extra Cold Climate Area
This design and technical manual provides detailed specifications, installation guidelines, performance data, and operational information for Fujitsu wall-mounted air conditioning systems (ASUG/AOUG series) engineered for extra cold climate conditions.