SCT-1100 Quick Setup Guide

Key Functions

Key Function Key Function Key Function
ZERO In setup: scroll forward through parameters
In numeric input: decreases digit to be modified
MODE In setup: quickly position the first step of a menu
In numeric input: selects digit to be modified, from left to right
C ON/OFF Turn the instrument on/off
In setup: exit a step without confirming the setting
In numeric input: clears the present value
TARE In setup: scroll back through the functions
In numeric input: increases digit to be modified
PRINT In setup: enter into a parameter or to confirm a setting
In numeric input: confirms the entry made

Setup Menu

  1. Press the ON/OFF key (C) to turn the instrument on.
  2. Press the mode key (►) when the firmware version displays to enter the setup menu.
  3. Press the print key (◄◄) in the setup menu to view/select the parameter choices.

Parameter Selection and Configuration:

Parameter Description
EYPE Press and [up/down arrows] to set channel type (e.g., ch, trAn57, or dEP .ch).
nChan Press and [up/down arrows] to select the number of channels.
ChAn Press and [up/down arrows] to select the channel to calibrate.
du.dec Press and [up/down arrows] to set decimals and minimum division.
CAPAC Press and [up/down arrows] to set the scale capacity.
CEL.CAP Press and [up/down arrows] to set the total capacity of the load cells.
CEL.SEN Press and [up/down arrows] to set the mV/V sensitivity of the load cell.
DEAD .Ld Press and [up/down arrows] to set the dead load present on the load cell.
0.CAL16 Quick calibration of zero. Press and [up/down arrows] to set the zero value. For new acquisition of zero, with scale empty. Establishes new zero reference.
SPAN Apply calibration weight. Press and [up/down arrows] to enter applied calibration weight.
Adc.uu Check the load cell signal in millivolts.
An.out Select channel to be configured.
RONAH Set the analog output on net or gross weight.
Ao2Er Set the maximum value of analog output.
Aon in Set the analog output when scale shows zero weight.
485 Set the minimum value of analog output.
SEE .Add Set the key to be emulated by the input.
bAud Press and [up/down arrows] to set baud rate.

Calibration Information:

Default Factory Calibration: The instrument has a default calibration with a capacity of 10,000 kg, load cell sensitivity of 2.000mV/V, and 1 division.

Theoretical Calibration: Use parameters EYPE, nChan, chan, du.dec, CAPAC, CEL.CAP, CEL.SEN, DEAD.Ld to perform a theoretical calibration.

Calibration Using Known Weight: Use parameters EYPE, nChan, chan, du.dec, CEL.CAP, 2Ero, SPAn to perform a standard calibration with a known weight. For parameters 2Ero & SPAn, press and wait for ERNOT, STORE?. Then press [enter key] to accept. For parameter SPAn, apply test weight before pressing [enter key].

Setpoint Programming

In the weigh mode, press and hold [enter key] to access output's setpoint programming.

Parameter Description
outPut Select channel to be configured.
norni Set the output normal state.
FunC Setpoint on the gross weight.
Gro5 Disabled.
net Setpoint on the net weight.

Wiring Diagram

The document includes a detailed wiring diagram illustrating the connections for Load Cells 1, 2, 3, and 4, as well as power supply, analog output, serial port, inputs, outputs, and relays.

Pin Assignments:

Note: When settings are complete, press C until the indicator displays SAUEP. Press [enter key] to save setup and return to weigh mode. Pressing any other key exits the setup and discards changes.

Models: SCT-1100 Signal Conditioning Transmitter, Signal Conditioning Transmitter, Conditioning Transmitter, Transmitter

File Info : application/pdf, 2 Pages, 536.11KB

PDF preview unavailable. Download the PDF instead.

a us 185438 quicksetupguide sct-1100

References

Adobe PDF Library 17.0

Related Documents

Preview Rice Lake Weight Indicator Guide
A comprehensive guide to Rice Lake Weighing Systems' digital weight indicators and controllers, covering programmable, general purpose, basic weighing, signal conditioning transmitters, specialty, and remote display indicators.
Preview SCT-1100 Advanced Series Weight Transmitter Technical Manual
This technical manual provides comprehensive information on the Rice Lake SCT-1100 Advanced Series Weight Transmitter, covering its features, installation, operation, calibration, and troubleshooting. It is designed for users to understand the instrument's functions, key features, and display indications.
Preview SCT-4XD Belt Scale Integrator Technical Manual
This technical manual provides comprehensive information on the SCT-4XD Belt Scale Integrator, covering its introduction, installation, setup, calibration, operation, communications, fieldbus integration, and specifications. It includes safety guidelines, definitions, and detailed procedures for accurate weight measurement and data integration.
Preview 1280 Enterprise Series Color Touchscreen Programmable Indicator Technical Manual
Comprehensive technical manual for the Rice Lake Weighing Systems 1280 Enterprise Series color touchscreen programmable indicator, covering installation, configuration, features, and operation.
Preview IQplus 800/810 Panel Mounting Kit Installation Guide
Detailed installation guide for the Rice Lake Weighing Systems IQplus 800/810 Panel Mounting Kit, including cut-out dimensions and step-by-step instructions for desktop model integration.
Preview SCT-4XD Belt Scale Integrator Technical Manual
This technical manual provides comprehensive information on the SCT-4XD Belt Scale Integrator, covering installation, configuration, calibration, operation, communications, fieldbus integration, and specifications. It is designed for users and technicians working with Rice Lake Weighing Systems.
Preview Rice Lake 1280 HMI Conveyor Belt Scale System with SCT-4XD Integrator
Discover the Rice Lake 1280 HMI Conveyor Belt Scale System with the SCT-4XD Integrator. This system offers advanced data and diagnostics for real-time weighing operations, featuring a high-speed integrator, dual speed encoders, and support for up to four load cells. Enhance efficiency with its customizable graphical interface, integrated web server, and system data tracking capabilities.
Preview SCT-2200 Advanced Series Weight Transmitter Technical Manual
This technical manual provides comprehensive information on the Rice Lake SCT-2200 Advanced Series Weight Transmitter, covering its introduction, installation, operation, setup, calibration, communications, compliance, and specifications. It is designed to help technicians understand the unit's functioning modes, key functions, and display indications.