TÜV Rheinland Test Report - Products
Test Report No.: CN255G0F 001
Client Reference No.: 1288983
Client: IKEA of Sweden AB, Box 702, SE-343 81 Älmhult, Sweden
Test Item: Self-ballasted LED lamp
Identification / Type No.: LED2419G4NA
FCC ID: FHO-LED2419G4NA
Order Content: TÜV Rheinland EMC service
Test Specification: FCC 47 CFR Part 15, Subpart B:2023 Class B, ICES-005:2018
Date of Sample Receipt: 2025-02-01
Test Result: Pass
Tested By: Jessie Xu, Project Engineer
Authorized By: [Authorizer Name - Signature Placeholder], Authorizer
Issue Date: 2025-04-03
Remarks
1. All test equipment used was calibrated according to the test laboratory's calibration program and meets the requirements of the test programs. Traceability is ensured by the management system. Detailed information on test conditions, equipment, and measurement uncertainty is available upon request.
2. This document is digitally signed as agreed. TÜV Rheinland has not verified the legal or other requirements applicable to this document; this is the user's responsibility. Validity of the digital signature can be confirmed by a separate document upon request to the sales department, subject to an environmental fee.
3. Test clauses marked with * were subcontracted to qualified subcontractors. Deviations from specifications or customer requirements are listed in the respective test clause.
4. The decision rule for conformity statements is based on the "Zero Guard Band Rule" and "Simple Acceptance" per ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified. Measurement uncertainty is not considered in this report.
General Product Information
2.1 Product Function and Intended Use
The EUT (equipment under test) is an ordinary self-ballasted LED lamp for lighting and similar use. Refer to the user's manual for further information.
2.2 Ratings and System Details
- Rated Input: AC 120 V, 60 Hz, 38 mA
- Rated Power: 3.8 W
2.3 Independent Operation Modes
The basic operation modes are "ON" and "OFF". Test modes included:
- Mode 1: Lighting on with maximum lighting output via dimmer.
- Mode 2: Lighting on with minimum lighting output via dimmer.
2.4 Description of Interconnecting Cables
N/A
2.5 Noise Generating and Noise Suppressing Parts
Refer to the circuit diagram for further information.
2.6 Highest Frequency Generated or Used
The highest frequency used in the EUT is 49 kHz.
2.7 Submitted Documents
Circuit diagram, user's manual, and rating label.
Test Set-up and Operation Modes
3.1 Principle of Configuration Selection
For emission testing, the EUT was configured to measure its highest possible emission level under adapted test conditions. The sequence of testing was: Conducted emission tests on 2025-02-24 and Radiated emission tests on 2025-02-26.
3.2 Equipment and Cable Arrangement
A block diagram illustrates the conducted emission test setup. It shows the Equipment Under Test (EUT) connected to a Line Impedance Stabilization Network (LISN). The LISN is connected to a transformer, power supply, and then to an EMI receiver and computer for measurement. The EUT is positioned 0.8 meters from the LISN, with the power cord bundled to a length of 0.3-0.4 meters.
A block diagram illustrates the radiated emission test setup. It depicts the EUT placed on a 0.8m high support. A receiving antenna is positioned 3 meters away from the EUT. The antenna height can be varied from 1 to 4 meters, and the EUT is rotated 360 degrees to find maximum disturbance.
3.3 Test Software
No special test software was used.
3.4 Special Accessories and Auxiliary Equipment
During the EMI tests, a dimmer (model: ICDL-20NA-BI-2, brand: IKEA) was used.
3.5 Countermeasures to Achieve EMC Compliance
No other special measures were employed.
Conformity Decision Rule
For all EMI tests, compliance with limits is determined by comparing measurement results directly with corresponding limits, without considering measurement uncertainties, as the uncertainties are less than the values specified in CISPR 16-4-2.
Test Results Emission
5.1 Emission in the Frequency Range up to 30 MHz (Conducted Emission)
Result: Passed
Date of Testing: 2025-02-24
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-1
Frequency Range: 0.15 - 30 MHz
Limits:
- Quasi-peak limit: 0.15-0.5 MHz: 66 to 56 dBμV (decreasing with frequency); 0.5-5 MHz: 56 dBμV; 5-30 MHz: 60 dBμV
- Average limit: 0.15-0.5 MHz: 56 to 46 dBμV (decreasing with frequency); 0.5-5 MHz: 46 dBμV; 5-30 MHz: 50 dBμV
Bandwidth of EMI receiver: 9 kHz
Measurement Time: 1 s
Kind of Test Site: Shielded room
Input Voltage: AC 120 V, 60 Hz
Ambient Conditions: Temperature: 24.2 °C; Relative humidity: 45.6 %
Expanded Measurement Uncertainty (k=2): 2.33 dB
The minimum margin to the limit is 5.64 dB at 0.152250 MHz.
Mode 1: Lighting on with max. lighting output
Final Quasi-peak measurement result (Mode 1):Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.152250 | 56.52 | 65.88 | 9.36 | 1000.0 | 9.000 | L1 |
0.750750 | 21.12 | 56.00 | 34.88 | 1000.0 | 9.000 | L1 |
0.892500 | 20.78 | 56.00 | 35.22 | 1000.0 | 9.000 | L1 |
20.629500 | 22.81 | 60.00 | 37.19 | 1000.0 | 9.000 | L1 |
20.757750 | 22.39 | 60.00 | 37.61 | 1000.0 | 9.000 | L1 |
20.886000 | 22.89 | 60.00 | 37.11 | 1000.0 | 9.000 | L1 |
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.150000 | 26.07 | 56.00 | 29.93 | 1000.0 | 9.000 | L1 |
20.249250 | 15.03 | 50.00 | 34.97 | 1000.0 | 9.000 | L1 |
20.629500 | 16.97 | 50.00 | 33.03 | 1000.0 | 9.000 | L1 |
20.757750 | 16.34 | 50.00 | 33.66 | 1000.0 | 9.000 | L1 |
20.886000 | 16.17 | 50.00 | 33.83 | 1000.0 | 9.000 | L1 |
21.005250 | 14.94 | 50.00 | 35.06 | 1000.0 | 9.000 | L1 |
Mode 2: Lighting on with min. lighting output
Final Quasi-peak measurement result (Mode 2):Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.152250 | 60.23 | 65.88 | 5.64 | 1000.0 | 9.000 | L1 |
0.516750 | 26.50 | 56.00 | 29.50 | 1000.0 | 9.000 | L1 |
0.919500 | 24.97 | 56.00 | 31.03 | 1000.0 | 9.000 | L1 |
2.136750 | 20.10 | 56.00 | 35.90 | 1000.0 | 9.000 | L1 |
20.629500 | 22.18 | 60.00 | 37.82 | 1000.0 | 9.000 | L1 |
20.888250 | 22.37 | 60.00 | 37.63 | 1000.0 | 9.000 | L1 |
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.150000 | 29.40 | 56.00 | 26.60 | 1000.0 | 9.000 | L1 |
20.249250 | 14.47 | 50.00 | 35.53 | 1000.0 | 9.000 | L1 |
20.629500 | 16.07 | 50.00 | 33.93 | 1000.0 | 9.000 | L1 |
20.757750 | 15.87 | 50.00 | 34.13 | 1000.0 | 9.000 | L1 |
20.886000 | 15.68 | 50.00 | 34.32 | 1000.0 | 9.000 | L1 |
21.005250 | 14.51 | 50.00 | 35.49 | 1000.0 | 9.000 | L1 |
5.1.1 Conducted Emission (Neutral Line)
The spectral diagrams and tables for conducted emission on the Neutral line (N) are presented below.
Mode 1: Lighting on with max. lighting output
Final Quasi-peak measurement result (Mode 1, Neutral):Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.152250 | 57.63 | 65.88 | 8.25 | 1000.0 | 9.000 | N |
0.363750 | 29.37 | 58.64 | 29.27 | 1000.0 | 9.000 | N |
0.879000 | 19.25 | 56.00 | 36.75 | 1000.0 | 9.000 | N |
20.629500 | 22.83 | 60.00 | 37.17 | 1000.0 | 9.000 | N |
20.757750 | 22.28 | 60.00 | 37.72 | 1000.0 | 9.000 | N |
20.888250 | 22.98 | 60.00 | 37.02 | 1000.0 | 9.000 | N |
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.150000 | 26.96 | 56.00 | 29.04 | 1000.0 | 9.000 | N |
20.249250 | 15.03 | 50.00 | 34.97 | 1000.0 | 9.000 | N |
20.629500 | 17.08 | 50.00 | 32.92 | 1000.0 | 9.000 | N |
20.757750 | 16.04 | 50.00 | 33.96 | 1000.0 | 9.000 | N |
20.886000 | 16.14 | 50.00 | 33.86 | 1000.0 | 9.000 | N |
21.005250 | 14.77 | 50.00 | 35.23 | 1000.0 | 9.000 | N |
Mode 2: Lighting on with min. lighting output
Final Quasi-peak measurement result (Mode 2, Neutral):Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.152250 | 59.55 | 65.88 | 6.33 | 1000.0 | 9.000 | N |
0.354750 | 36.45 | 58.85 | 22.40 | 1000.0 | 9.000 | N |
0.363750 | 36.06 | 58.64 | 22.58 | 1000.0 | 9.000 | N |
0.505500 | 29.36 | 56.00 | 26.64 | 1000.0 | 9.000 | N |
0.915000 | 23.48 | 56.00 | 32.52 | 1000.0 | 9.000 | N |
2.220000 | 19.99 | 56.00 | 36.01 | 1000.0 | 9.000 | N |
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line |
---|---|---|---|---|---|---|
0.150000 | 29.01 | 56.00 | 27.00 | 1000.0 | 9.000 | N |
20.620500 | 16.29 | 50.00 | 33.71 | 1000.0 | 9.000 | N |
20.757750 | 16.62 | 50.00 | 33.38 | 1000.0 | 9.000 | N |
20.886000 | 15.96 | 50.00 | 34.04 | 1000.0 | 9.000 | N |
21.005250 | 15.02 | 50.00 | 34.98 | 1000.0 | 9.000 | N |
21.133500 | 14.06 | 50.00 | 35.94 | 1000.0 | 9.000 | N |
5.2 Emission in the Frequency Range above 30 MHz (Radiated Emission 30-1000 MHz)
Result: Passed
Date of Testing: 2025-02-26
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-3
Product Classification: Class B
Frequency Range: 30 – 1000 MHz
Limits (3 m distance):
- 30 – 88 MHz: 40 dBμV/m
- 88 – 216 MHz: 43.5 dBμV/m
- 216 – 1000 MHz: 46 dBμV/m
Bandwidth of EMI receiver: 120 kHz
Measurement Time: 1 s
Kind of Test Site: Semi-anechoic chamber
Input Voltage: AC 120 V, 60 Hz
Ambient Conditions: Temperature: 24.1 °C; Relative humidity: 46.2 %
Expanded Measurement Uncertainty (k=2): 5.40 dB
The minimum margin to the limit is 12.0 dB.
Mode 1: Lighting on with max. lighting output
Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 1Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - QPK (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
30.606250 | 27.8 | 120.000 | 145.0 | H | 102 | 24.5 | 12.2 | 40.0 |
115.966250 | 21.8 | 120.000 | 148.0 | H | 113 | 18.8 | 21.7 | 43.5 |
149.673750 | 20.8 | 120.000 | 197.0 | H | -104 | 17.6 | 22.8 | 43.5 |
262.193750 | 24.0 | 120.000 | 126.0 | H | -176 | 20.9 | 22.0 | 46.0 |
599.268750 | 30.8 | 120.000 | 157.0 | H | 10 | 26.9 | 15.2 | 46.0 |
972.355000 | 33.8 | 120.000 | 137.0 | H | 69 | 29.7 | 12.2 | 46.0 |
Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - QPK (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
30.606250 | 27.9 | 120.000 | 123.0 | V | 24 | 24.5 | 12.1 | 40.0 |
31.455000 | 27.4 | 120.000 | 145.0 | V | -133 | 24.1 | 12.6 | 40.0 |
140.822500 | 21.3 | 120.000 | 178.0 | V | -47 | 18.2 | 22.2 | 43.5 |
590.902500 | 30.6 | 120.000 | 189.0 | V | -7 | 26.8 | 15.4 | 46.0 |
881.417500 | 33.3 | 120.000 | 154.0 | V | -158 | 28.7 | 12.7 | 46.0 |
992.118750 | 34.0 | 120.000 | 167.0 | V | -76 | 29.8 | 12.0 | 46.0 |
Mode 2: Lighting on with min. lighting output
Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 2Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - QPK (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
30.848750 | 27.8 | 120.000 | 159.0 | H | 14 | 24.4 | 12.2 | 40.0 |
32.425000 | 27.0 | 120.000 | 149.0 | H | -87 | 23.7 | 13.0 | 40.0 |
128.455000 | 21.8 | 120.000 | 128.0 | H | -141 | 18.7 | 21.7 | 43.5 |
255.767500 | 23.2 | 120.000 | 194.0 | H | -77 | 20.2 | 22.8 | 46.0 |
603.027500 | 30.5 | 120.000 | 149.0 | H | 67 | 27.0 | 15.5 | 46.0 |
976.113750 | 34.0 | 120.000 | 157.0 | H | 36 | 29.7 | 12.0 | 46.0 |
Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin - QPK (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
30.242500 | 28.1 | 120.000 | 135.0 | V | -44 | 24.7 | 12.0 | 40.0 |
33.152500 | 26.6 | 120.000 | 148.0 | V | -77 | 23.4 | 13.4 | 40.0 |
128.940000 | 21.7 | 120.000 | 195.0 | V | -93 | 18.7 | 21.8 | 43.5 |
263.042500 | 23.9 | 120.000 | 167.0 | V | 152 | 20.8 | 22.1 | 46.0 |
863.230000 | 33.3 | 120.000 | 155.0 | V | 145 | 28.8 | 12.7 | 46.0 |
974.173750 | 33.8 | 120.000 | 125.0 | V | -50 | 29.7 | 12.2 | 46.0 |
List of Test and Measurement Instruments
Equip. | Description | Model | Manufacturer | Last Date | Due Date |
---|---|---|---|---|---|
9061503 | Shielded enclosure | 10.055x3.605x3.000 | Frankonia | 08.11.2023 | 08.11.2028 |
9023229 | EMI test receiver | ESR3 | Rohde&Schwarz | 03.08.2024 | 03.08.2025 |
G1830003 | Artificial mains network | ENV432 | Rohde&Schwarz | 11.10.2024 | 11.10.2025 |
G1824248 | Dual display multimeter | F45 | Fluke | 28.06.2024 | 28.06.2025 |
9062744 | EMI measurement software | EMC32-E+(10.60.20) | Rohde&Schwarz | N/A | N/A |
G1811378 | 3m semi-anechoic chamber | SAC3 | Frankonia | 03.12.2023 | 03.12.2026 |
G1811391 | EMI test receiver | ESCI | Rohde & Schwarz | 17.10.2024 | 17.10.2025 |
G1811425 | Bilog antenna | CBL 6112D | Teseq | 20.04.2023 | 20.04.2026 |
9062745 | EMI measurement software | EMC32-MEB (10.60.20) | Rohde&Schwarz | N/A | N/A |
List of Figures
- Figure 1: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, L, Mode 1
- Figure 2: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, N, Mode 1
- Figure 3: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, L, Mode 2
- Figure 4: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, N, Mode 2
- Figure 5: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 1
- Figure 6: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Vertical polarization, Mode 1
- Figure 7: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 2
- Figure 8: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Vertical polarization, Mode 2
End of test report