TÜV Rheinland Test Report - Products

Test Report No.: CN255G0F 001

Client Reference No.: 1288983

Client: IKEA of Sweden AB, Box 702, SE-343 81 Älmhult, Sweden

Test Item: Self-ballasted LED lamp

Identification / Type No.: LED2419G4NA

FCC ID: FHO-LED2419G4NA

Order Content: TÜV Rheinland EMC service

Test Specification: FCC 47 CFR Part 15, Subpart B:2023 Class B, ICES-005:2018

Date of Sample Receipt: 2025-02-01

Test Result: Pass

Tested By: Jessie Xu, Project Engineer

Authorized By: [Authorizer Name - Signature Placeholder], Authorizer

Issue Date: 2025-04-03

Remarks

1. All test equipment used was calibrated according to the test laboratory's calibration program and meets the requirements of the test programs. Traceability is ensured by the management system. Detailed information on test conditions, equipment, and measurement uncertainty is available upon request.

2. This document is digitally signed as agreed. TÜV Rheinland has not verified the legal or other requirements applicable to this document; this is the user's responsibility. Validity of the digital signature can be confirmed by a separate document upon request to the sales department, subject to an environmental fee.

3. Test clauses marked with * were subcontracted to qualified subcontractors. Deviations from specifications or customer requirements are listed in the respective test clause.

4. The decision rule for conformity statements is based on the "Zero Guard Band Rule" and "Simple Acceptance" per ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified. Measurement uncertainty is not considered in this report.

General Product Information

2.1 Product Function and Intended Use

The EUT (equipment under test) is an ordinary self-ballasted LED lamp for lighting and similar use. Refer to the user's manual for further information.

2.2 Ratings and System Details

  • Rated Input: AC 120 V, 60 Hz, 38 mA
  • Rated Power: 3.8 W

2.3 Independent Operation Modes

The basic operation modes are "ON" and "OFF". Test modes included:

  • Mode 1: Lighting on with maximum lighting output via dimmer.
  • Mode 2: Lighting on with minimum lighting output via dimmer.

2.4 Description of Interconnecting Cables

N/A

2.5 Noise Generating and Noise Suppressing Parts

Refer to the circuit diagram for further information.

2.6 Highest Frequency Generated or Used

The highest frequency used in the EUT is 49 kHz.

2.7 Submitted Documents

Circuit diagram, user's manual, and rating label.

Test Set-up and Operation Modes

3.1 Principle of Configuration Selection

For emission testing, the EUT was configured to measure its highest possible emission level under adapted test conditions. The sequence of testing was: Conducted emission tests on 2025-02-24 and Radiated emission tests on 2025-02-26.

3.2 Equipment and Cable Arrangement

A block diagram illustrates the conducted emission test setup. It shows the Equipment Under Test (EUT) connected to a Line Impedance Stabilization Network (LISN). The LISN is connected to a transformer, power supply, and then to an EMI receiver and computer for measurement. The EUT is positioned 0.8 meters from the LISN, with the power cord bundled to a length of 0.3-0.4 meters.

A block diagram illustrates the radiated emission test setup. It depicts the EUT placed on a 0.8m high support. A receiving antenna is positioned 3 meters away from the EUT. The antenna height can be varied from 1 to 4 meters, and the EUT is rotated 360 degrees to find maximum disturbance.

3.3 Test Software

No special test software was used.

3.4 Special Accessories and Auxiliary Equipment

During the EMI tests, a dimmer (model: ICDL-20NA-BI-2, brand: IKEA) was used.

3.5 Countermeasures to Achieve EMC Compliance

No other special measures were employed.

Conformity Decision Rule

For all EMI tests, compliance with limits is determined by comparing measurement results directly with corresponding limits, without considering measurement uncertainties, as the uncertainties are less than the values specified in CISPR 16-4-2.

Test Results Emission

5.1 Emission in the Frequency Range up to 30 MHz (Conducted Emission)

Result: Passed

Date of Testing: 2025-02-24

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-1

Frequency Range: 0.15 - 30 MHz

Limits:

  • Quasi-peak limit: 0.15-0.5 MHz: 66 to 56 dBμV (decreasing with frequency); 0.5-5 MHz: 56 dBμV; 5-30 MHz: 60 dBμV
  • Average limit: 0.15-0.5 MHz: 56 to 46 dBμV (decreasing with frequency); 0.5-5 MHz: 46 dBμV; 5-30 MHz: 50 dBμV

Bandwidth of EMI receiver: 9 kHz

Measurement Time: 1 s

Kind of Test Site: Shielded room

Input Voltage: AC 120 V, 60 Hz

Ambient Conditions: Temperature: 24.2 °C; Relative humidity: 45.6 %

Expanded Measurement Uncertainty (k=2): 2.33 dB

The minimum margin to the limit is 5.64 dB at 0.152250 MHz.

Mode 1: Lighting on with max. lighting output

Final Quasi-peak measurement result (Mode 1):
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15225056.5265.889.361000.09.000L1
0.75075021.1256.0034.881000.09.000L1
0.89250020.7856.0035.221000.09.000L1
20.62950022.8160.0037.191000.09.000L1
20.75775022.3960.0037.611000.09.000L1
20.88600022.8960.0037.111000.09.000L1
Final Average measurement result (Mode 1):
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15000026.0756.0029.931000.09.000L1
20.24925015.0350.0034.971000.09.000L1
20.62950016.9750.0033.031000.09.000L1
20.75775016.3450.0033.661000.09.000L1
20.88600016.1750.0033.831000.09.000L1
21.00525014.9450.0035.061000.09.000L1

Mode 2: Lighting on with min. lighting output

Final Quasi-peak measurement result (Mode 2):
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15225060.2365.885.641000.09.000L1
0.51675026.5056.0029.501000.09.000L1
0.91950024.9756.0031.031000.09.000L1
2.13675020.1056.0035.901000.09.000L1
20.62950022.1860.0037.821000.09.000L1
20.88825022.3760.0037.631000.09.000L1
Final Average measurement result (Mode 2):
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15000029.4056.0026.601000.09.000L1
20.24925014.4750.0035.531000.09.000L1
20.62950016.0750.0033.931000.09.000L1
20.75775015.8750.0034.131000.09.000L1
20.88600015.6850.0034.321000.09.000L1
21.00525014.5150.0035.491000.09.000L1

5.1.1 Conducted Emission (Neutral Line)

The spectral diagrams and tables for conducted emission on the Neutral line (N) are presented below.

Mode 1: Lighting on with max. lighting output

Final Quasi-peak measurement result (Mode 1, Neutral):
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15225057.6365.888.251000.09.000N
0.36375029.3758.6429.271000.09.000N
0.87900019.2556.0036.751000.09.000N
20.62950022.8360.0037.171000.09.000N
20.75775022.2860.0037.721000.09.000N
20.88825022.9860.0037.021000.09.000N
Final Average measurement result (Mode 1, Neutral):
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15000026.9656.0029.041000.09.000N
20.24925015.0350.0034.971000.09.000N
20.62950017.0850.0032.921000.09.000N
20.75775016.0450.0033.961000.09.000N
20.88600016.1450.0033.861000.09.000N
21.00525014.7750.0035.231000.09.000N

Mode 2: Lighting on with min. lighting output

Final Quasi-peak measurement result (Mode 2, Neutral):
Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15225059.5565.886.331000.09.000N
0.35475036.4558.8522.401000.09.000N
0.36375036.0658.6422.581000.09.000N
0.50550029.3656.0026.641000.09.000N
0.91500023.4856.0032.521000.09.000N
2.22000019.9956.0036.011000.09.000N
Final Average measurement result (Mode 2, Neutral):
Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line
0.15000029.0156.0027.001000.09.000N
20.62050016.2950.0033.711000.09.000N
20.75775016.6250.0033.381000.09.000N
20.88600015.9650.0034.041000.09.000N
21.00525015.0250.0034.981000.09.000N
21.13350014.0650.0035.941000.09.000N

5.2 Emission in the Frequency Range above 30 MHz (Radiated Emission 30-1000 MHz)

Result: Passed

Date of Testing: 2025-02-26

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-3

Product Classification: Class B

Frequency Range: 30 – 1000 MHz

Limits (3 m distance):

  • 30 – 88 MHz: 40 dBμV/m
  • 88 – 216 MHz: 43.5 dBμV/m
  • 216 – 1000 MHz: 46 dBμV/m

Bandwidth of EMI receiver: 120 kHz

Measurement Time: 1 s

Kind of Test Site: Semi-anechoic chamber

Input Voltage: AC 120 V, 60 Hz

Ambient Conditions: Temperature: 24.1 °C; Relative humidity: 46.2 %

Expanded Measurement Uncertainty (k=2): 5.40 dB

The minimum margin to the limit is 12.0 dB.

Mode 1: Lighting on with max. lighting output

Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 1
Frequency (MHz) QuasiPeak (dBμV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m)
30.60625027.8120.000145.0H10224.512.240.0
115.96625021.8120.000148.0H11318.821.743.5
149.67375020.8120.000197.0H-10417.622.843.5
262.19375024.0120.000126.0H-17620.922.046.0
599.26875030.8120.000157.0H1026.915.246.0
972.35500033.8120.000137.0H6929.712.246.0
Radiated Emission, 30 MHz – 1000 MHz, Vertical polarization, Mode 1
Frequency (MHz) QuasiPeak (dBμV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m)
30.60625027.9120.000123.0V2424.512.140.0
31.45500027.4120.000145.0V-13324.112.640.0
140.82250021.3120.000178.0V-4718.222.243.5
590.90250030.6120.000189.0V-726.815.446.0
881.41750033.3120.000154.0V-15828.712.746.0
992.11875034.0120.000167.0V-7629.812.046.0

Mode 2: Lighting on with min. lighting output

Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 2
Frequency (MHz) QuasiPeak (dBμV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m)
30.84875027.8120.000159.0H1424.412.240.0
32.42500027.0120.000149.0H-8723.713.040.0
128.45500021.8120.000128.0H-14118.721.743.5
255.76750023.2120.000194.0H-7720.222.846.0
603.02750030.5120.000149.0H6727.015.546.0
976.11375034.0120.000157.0H3629.712.046.0
Radiated Emission, 30 MHz – 1000 MHz, Vertical polarization, Mode 2
Frequency (MHz) QuasiPeak (dBμV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin - QPK (dB) Limit - QPK (dBμV/m)
30.24250028.1120.000135.0V-4424.712.040.0
33.15250026.6120.000148.0V-7723.413.440.0
128.94000021.7120.000195.0V-9318.721.843.5
263.04250023.9120.000167.0V15220.822.146.0
863.23000033.3120.000155.0V14528.812.746.0
974.17375033.8120.000125.0V-5029.712.246.0

List of Test and Measurement Instruments

Equip. Description Model Manufacturer Last Date Due Date
9061503Shielded enclosure10.055x3.605x3.000Frankonia08.11.202308.11.2028
9023229EMI test receiverESR3Rohde&Schwarz03.08.202403.08.2025
G1830003Artificial mains networkENV432Rohde&Schwarz11.10.202411.10.2025
G1824248Dual display multimeterF45Fluke28.06.202428.06.2025
9062744EMI measurement softwareEMC32-E+(10.60.20)Rohde&SchwarzN/AN/A
G18113783m semi-anechoic chamberSAC3Frankonia03.12.202303.12.2026
G1811391EMI test receiverESCIRohde & Schwarz17.10.202417.10.2025
G1811425Bilog antennaCBL 6112DTeseq20.04.202320.04.2026
9062745EMI measurement softwareEMC32-MEB (10.60.20)Rohde&SchwarzN/AN/A

List of Figures

  • Figure 1: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, L, Mode 1
  • Figure 2: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, N, Mode 1
  • Figure 3: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, L, Mode 2
  • Figure 4: Spectral Diagrams, Conducted Emission, 150 kHz – 30 MHz, N, Mode 2
  • Figure 5: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 1
  • Figure 6: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Vertical polarization, Mode 1
  • Figure 7: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Horizontal polarization, Mode 2
  • Figure 8: Spectral Diagrams, Radiated Emission, 30 MHz – 1000 MHz, Vertical polarization, Mode 2

End of test report

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8200779 Microsoft Word for Microsoft 365; modified using iTextSharp™ 5.5.13.3 ©2000-2022 iText Group NV (AGPL-version)

Related Documents

Preview TÜV Rheinland EMC Test Report for IKEA Self-Ballasted LED Lamp (LED2415G1NA)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA Self-Ballasted LED Lamp, model LED2415G1NA. The testing covers conducted and radiated emissions according to FCC 47 CFR Part 15, Subpart B:2023 and ICES-005:2018 standards.
Preview IKEA LED2405G8NA Self-Ballasted LED Lamp EMC Test Report
Comprehensive EMC test report for the IKEA LED2405G8NA self-ballasted LED lamp, detailing conducted and radiated emissions testing against FCC and IC standards. Includes test results, limits, and equipment specifications.
Preview IKEA LED2404G6NA Selbst-ballastierte LED-Lampe: EMV-Prüfbericht
Dieser Prüfbericht von TÜV Rheinland dokumentiert die elektromechanische Kompatibilitätsprüfung (EMV) für die selbst-ballastierte LED-Lampe von IKEA, Modell LED2404G6NA. Die Lampe ist für Beleuchtungs- und ähnliche Anwendungen konzipiert und verfügt über eine drahtlose Dimmfunktion.
Preview TÜV Rheinland Test Report for IKEA B2406 LED Lamp - EMC Compliance
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA B2406 LED Lamp, covering conducted and radiated emissions according to FCC and ICES standards.
Preview TÜV Rheinland Test Report: IKEA LED2408G10NA Self-ballasted LED Lamps EMC Compliance
This TÜV Rheinland test report details the Electromagnetic Compatibility (EMC) testing performed on IKEA's LED2408G10NA self-ballasted LED lamps. The report covers conducted and radiated emission tests according to FCC 47 CFR Part 15, Subpart B:2023 and ICES-005:2018 standards.
Preview IKEA LED2418G3CF Self-Ballasted LED Lamp EMC Test Report
This report details the Electromagnetic Compatibility (EMC) testing conducted on the IKEA self-ballasted LED lamp, model LED2418G3CF, by TÜV Rheinland. It covers conducted and radiated emissions according to FCC and ICES standards.
Preview TÜV Rheinland Test Report for IKEA LED2417G1CF Self-ballasted LED Lamp
This report details the EMC testing conducted by TÜV Rheinland on the IKEA LED2417G1CF self-ballasted LED lamp, covering conducted and radiated emissions according to FCC and ICES standards.
Preview TÜV Rheinland Test Report: IKEA Self-ballasted LED Lamp (LED2418G3NA) EMC Compliance
Detailed EMC test report by TÜV Rheinland for IKEA's self-ballasted LED lamp, model LED2418G3NA, covering conducted and radiated emissions according to FCC and ICES standards.