AirGladiator™: The Bullard Airline Filter

Seven Stage Filtration. One Filter.

Performance Benefits

AirGladiator provides 7-stage filtration to the required Grade D breathable air that when combined with carbon monoxide (CO) monitoring and other safeguards provides users with cleaner, more comfortable air. They may also be used to supply drier, cleaner air to tools, air monitoring box, and pneumatic systems.

Design

Sturdy Base and Mounting Versatility

Heavy Duty

High Capacity

Lightweight

Portable

Options

7-Stage Filtration

  1. Moisture is separated from air
  2. Carded cotton removes particulates
  3. Activated alumina absorbs oil and moisture
  4. Activated charcoal removes odors and moisture
  5. Felt material removes particulates
  6. Carded cotton removes particulates
  7. Respiratory felt at final stage acts as a final filter before air is transferred to worker or air driven tools

WARNING: Inlet air source MUST supply at least Grade D breathable air to the filter. Do not use AirGladiator in applications where the supplied air is not Grade D breathable air. Failure to do so could result in death or serious injury.

Diagram Description: A cut-away view of the AirGladiator filter cartridge showing the seven stages of filtration. The diagram illustrates the flow of air through different filtering materials.

Image Description: A yellow Bullard AirGladiator airline filter unit with a pressure gauge, relief valve, and manual drain valve. The part number AGLDTR2 is visible. The unit is shown in an upright position, with a warning to keep it upright to prevent tipping, which could result in death or serious injury.

Part Number: AGLDTR2

Manufacturer: Bullard

Website: www.bullard.com

Contact: 877-BULLARD

AirGladiator Technical Specifications

Airline Filter AGLDTR2 AGLDTR2E AGLDTR6
Max. Air Flow Rate 75 cfm (2120 Lpm) 75 cfm (2120 Lpm) 75 cfm (2120 Lpm)
Inlet Connection 1" NPT (Fem.) 3/4" BSPT (Fem.) 1" NPT (Fem.)
Outlet Connection 2 outlets 2 outlets 6 outlets
Relief Valve 3/8" NPT (Fem.) 3/8" NPT (Fem.) 3/8" NPT (Fem.)
Pressure Rating 125 psig (8.6 bar) 125 psig (8.6 bar) 125 psig (8.6 bar)
Tank Diameter 5 1/2" (14 cm) 5 1/2" (14 cm) 5 1/2" (14 cm)
Height 22" (55.9 cm) 22" (55.9 cm) 18.5" (47 cm)
Weight 29 lb (13.2 kg) 29 lb (13.2 kg) 32 lb (14.5 kg)

*At maximum recommended pressure of 100 psig (6.9 bar)

AirGladiator Ordering Information

Part Number Description Part Number Description
Airline Filter Replacement Parts and Accessory Items
AGLDTR2 2-outlet filter with pressure gauge, relief valve, pressure regulator, and hose adapter fittings (2 hose adapter fittings) 41AF Replacement Filter Cartridge
AGLDTR2E 2-outlet filter with pressure gauge, relief valve, pressure regulator, and hose adapter fittings (2 hose adapter fittings) AGLDAFCL5PK Change of Filter Cartridge Labels (5 pack)
AGLDTR6 6-outlet filter with pressure gauge, relief valve, pressure regulator, and hose adapter fittings (6 hose adapter fittings) AGLDDRAIN Petcock Drain Valve
AGLDTR6R Pressure Regulator (No Gauge)
AGLDPRV Pressure Relief Valve (125 psig / 8.6 bar)
AGLDRG Pressure Gauge
AG10FTCABKIT AirGladiator to CAB Connection Kit

*Full list available on Bullard.com

WARNING

AirGladiator does NOT create Grade D breathable air. AirGladiator is not intended to provide respiratory protection. The filter does not remove carbon monoxide and other toxic gases. Review and observe all pertinent federal and state safety regulations in conjunction with supplied-air respirators.

When using a NIOSH approved supplied-air respirator, do not connect the filter to any air source that does not contain at least Grade D breathable air.

Failure to read and follow these instructions could result in death or serious injury or life-threatening delayed lung disease including but not limited to pneumoconiosis, asbestosis or silicosis.

CALIFORNIA PROPOSITION 65 WARNING

Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

WARNING

Use only Bullard 41AF cartridges as replacements. Bullard AirGladiator Filters are designed to use only Bullard filter cartridges. Failure to use the correct filter cartridge could result in death or serious injury.

Filter cartridge must be changed periodically for maximum efficiency. Frequency of cartridge changes depends on operating conditions. Cartridge should be changed immediately if respirator wearer feels, smells or tastes contaminants inside the respirator. Filter tank should be drained at least daily to remove trapped water and oil (a petcock drain valve is provided on the bottom of the tank for this purpose). Failure to follow these instructions could result in death or serious injury.

Company Information

Bullard products are manufactured to exacting specifications. Any alteration or modification of these products by the user may adversely affect product performance. This information is in summary form only for easy reference. Refer to labels, instruction sheets and other literature accompanying the product for more complete details regarding product installation, use, maintenance, warnings, performance capabilities, complete specifications, user instructions and precautions.

Bullard Center

2421 Fortune Drive
Lexington, KY 40509. USA
877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-246-0243

Americas Operations

1898 Safety Way
Cynthiana, KY 41031 • USA
877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-234-8987

Bullard GmbH

Dieselstrasse 8a
53424 Remagen. Germany
Tel: +49-2642 999980
Fax: +49-2642 9999829

Bullard Asia Pacific Pte. Ltd.

51 Changi Business Park
Central 2
#03-04 The Signature
Singapore 486066
Tel: +65 6745 0556

www.bullard.com

ISO 9001 certified

©2023 Bullard. All rights reserved.

PDF preview unavailable. Download the PDF instead.

Bullard RP AirGladiator SalesSheet AM EN 1123 60810011990B Adobe PDF Library 17.0 Adobe InDesign 18.0 (Macintosh)

Related Documents

Preview Bullard Clean Air Boxes (CAB) Series User Manual
User manual for Bullard Clean Air Boxes (CAB) Series, detailing specifications, setup, operation, maintenance, troubleshooting, and warranty for models CAB15, CAB30, CAB50, and CAB100. Covers breathing air requirements, filtration, and CO monitoring.
Preview Bullard TrakLite User Instructions: Firefighting Helmet Light
Comprehensive user instructions for the Bullard TrakLite integrated helmet light. Learn about its features, operation, installation, maintenance, specifications, and warranty for American-style fire helmets.
Preview Bullard AC1000 Cool Climate Control Tube Instruction Sheet
Instruction sheet for the Bullard AC1000 Cool Climate Control Tube, detailing its function, preparation, use, and safety warnings for use with Bullard supplied air respirators. Includes assembly instructions for the heat shield.
Preview Bullard NXT Pro, QXT Pro, and DXT Thermal Imager Quick Setup Guide
A quick setup guide for Bullard NXT Pro, QXT Pro, and DXT Thermal Imagers, covering general operation, settings, and the MyBULLARD Imager Configurator.
Preview Bullard QXT Pro Thermal Imager User Manual
User manual for the Bullard QXT Pro Thermal Imager, providing instructions on operation, features, maintenance, and warranty.
Preview Bullard NXT Thermal Imager Bid Specifications
Detailed bid specifications for the Bullard NXT Thermal Imager, outlining requirements for warranty, service, quality standards, physical configuration, durability, technology, image colorization, housing, colors, display, lens, visual indicators, switches, power supply, operation, and truck mounting systems.
Preview Bullard UST/USTM and UST™-LW Series Helmets User Manual
User manual for Bullard UST, USTM, and UST-LW series firefighter helmets, detailing the U-Fit system for custom adjustment, Sure-Lock ratchet sizing, ReTrak visor and faceshield operation, Bourkes adjustment, cleaning, maintenance, warranty information, and replacement parts.
Preview Bullard TXS Thermal Imager Instruction Manual
Instruction manual for the Bullard TXS Thermal Imager, detailing its operation, features like Super Red Hot (SRH) colorization, battery charging, care instructions, troubleshooting, and important safety considerations for firefighters.