TÜV Rheinland Test Report: IKEA LED2413G3 Self-Ballasted LED Lamp
Test Report Number: CN24Y8IF 001
Client Reference: 1288983
Client: IKEA of Sweden AB, Box 702, SE-343 81 Älmhult, Sweden
Test Item: Self-ballasted LED lamp
Identification / Type No: LED2413G3
Test Specification: FCC 47 CFR Part 15, Subpart B:2023 Class B, ICES-005:2018
Testing Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.
Test Result: Pass
Tested By: Jessie Xu (Project Engineer)
Authorized By: Hexiong Liu (Authorizer)
Issue Date: 2025-02-18
FCC ID: FHO-LED2413G3
Product Information
Product Function and Intended Use: Ordinary self-ballasted LED lamp for lighting and similar use.
Ratings and System Details: Rated input: AC 120 V, 60 Hz, 47 mA; Rated power: 2.8 W.
Independent Operation Modes: "ON" and "OFF".
Highest Frequency Used: 120 Hz.
Submitted Documents: Circuit diagram, user's manual, and rating label.
Test Setup and Methodology
Test Facilities: TÜV Rheinland (Shanghai) Co., Ltd. located at Workshop14, North Half of Workshop 10 and Workshop 16, Pingqian (Taicang) Modern Industrial Park, No.525, Yuewang Lingang South Road, Shaxi, Taicang, Jiangsu, China. Test equipment is in accordance with CISPR 16-1 series standards.
Test Sequence: Conducted emission tests were performed on 2024-11-06. Radiated emission tests were performed on 2024-11-06.
Test Setup Description:
- Conducted Emission: The setup included the EUT, Line Impedance Stabilization Network (LISN), EMI receiver, computer, transformer, and power supply. The EUT was placed on a wooden support 0.8m from the AMN, with the power cord bundled.
- Radiated Emission: The test was conducted in a semi-anechoic chamber. The EUT was placed on an 80 cm wooden support. The antenna was positioned at a 3m distance and its height was varied from 1m to 4m to find maximum disturbance. Tests were performed with both horizontal and vertical antenna polarizations.
Test Software: No special test software was used.
Countermeasures: No special measures were employed to achieve EMC compliance.
Conformity Decision Rule
For all EMI tests, compliance is determined by comparing measurement results directly with limits, as measurement uncertainties are within specified values according to ILAC G8:2019 and IEC Guide 115:2021.
Test Results - Conducted Emission (0.15 MHz - 30 MHz)
Result: Passed
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-1.
Limits: Quasi-peak limits range from 56 to 66 dBμV, Average limits range from 46 to 56 dBμV.
Bandwidth: 9 kHz
Input Voltage: AC 120 V, 60 Hz
Ambient Condition: Temperature: 21.5 °C; Relative humidity: 48 %
Expanded Measurement Uncertainty (k=2): 2.33 dB
Minimum Margin: 40.75 dB at 15.321750 MHz.
Quasi-peak measurement results:
Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.354750 | 4.80 | 58.85 | 54.05 | 1000.0 | 9.000 | L1 | 10.3 |
0.838500 | 5.59 | 56.00 | 50.41 | 1000.0 | 9.000 | L1 | 10.5 |
0.951000 | 5.13 | 56.00 | 50.87 | 1000.0 | 9.000 | L1 | 10.7 |
4.929000 | 6.77 | 56.00 | 49.23 | 1000.0 | 9.000 | L1 | 10.3 |
7.048500 | 7.44 | 60.00 | 52.56 | 1000.0 | 9.000 | L1 | 10.9 |
15.321750 | 13.89 | 60.00 | 46.11 | 1000.0 | 9.000 | L1 | 10.8 |
Average measurement results:
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.361500 | -0.63 | 48.69 | 49.32 | 1000.0 | 9.000 | L1 | 10.3 |
0.872250 | -0.63 | 46.00 | 46.63 | 1000.0 | 9.000 | L1 | 10.6 |
0.964500 | -0.31 | 46.00 | 46.31 | 1000.0 | 9.000 | L1 | 10.7 |
3.999750 | 0.85 | 46.00 | 45.15 | 1000.0 | 9.000 | L1 | 10.2 |
8.000250 | 2.01 | 50.00 | 47.99 | 1000.0 | 9.000 | L1 | 10.8 |
15.321750 | 8.44 | 50.00 | 41.56 | 1000.0 | 9.000 | L1 | 10.8 |
Conducted Emission (Line N) Measurement Results:
Frequency (MHz) | QuasiPeak (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.361500 | 4.94 | 58.69 | 53.75 | 1000.0 | 9.000 | N | 10.4 |
0.710250 | 4.86 | 56.00 | 51.14 | 1000.0 | 9.000 | N | 10.4 |
1.990500 | 5.24 | 56.00 | 50.76 | 1000.0 | 9.000 | N | 10.5 |
3.999750 | 6.79 | 56.00 | 49.21 | 1000.0 | 9.000 | N | 10.7 |
11.924250 | 7.44 | 60.00 | 52.56 | 1000.0 | 9.000 | N | 11.1 |
15.481500 | 14.65 | 60.00 | 45.35 | 1000.0 | 9.000 | N | 11.1 |
Average measurement results (Line N):
Frequency (MHz) | CAverage (dBuV) | Limit (dBuV) | Margin (dB) | Meas. Time (ms) | Bandwidth (kHz) | Line | Corr. (dB) |
---|---|---|---|---|---|---|---|
0.361500 | -0.42 | 48.69 | 49.12 | 1000.0 | 9.000 | N | 10.4 |
0.721500 | -0.79 | 46.00 | 46.79 | 1000.0 | 9.000 | N | 10.4 |
2.026500 | -0.23 | 46.00 | 46.23 | 1000.0 | 9.000 | N | 10.5 |
3.999750 | 1.30 | 46.00 | 44.70 | 1000.0 | 9.000 | N | 10.7 |
9.915000 | 2.14 | 50.00 | 47.86 | 1000.0 | 9.000 | N | 11.1 |
15.321750 | 9.25 | 50.00 | 40.75 | 1000.0 | 9.000 | N | 11.1 |
Test Results - Radiated Emission (30 MHz - 1000 MHz)
Result: Passed
Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-3.
Product Classification: Class B
Frequency Range: 30 – 1000 MHz
Limits: Quasi-peak limits (3 m distance): 30–88 MHz: 40 dBμV/m; 88–216 MHz: 43.5 dBμV/m; 216–1000 MHz: 46 dBμV/m.
Bandwidth: 120 kHz
Input Voltage: AC 120 V, 60 Hz
Ambient Condition: Temperature: 20.5 °C; Relative humidity: 45 %
Expanded Measurement Uncertainty (k=2): 5.40 dB
Minimum Margin: 11.5 dB at 31.212500 MHz.
Radiated Emission - Horizontal Polarization Measurement Results:
Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
30.606250 | 27.8 | 120.000 | 200.0 | H | 15.0 | 24.5 | 12.2 | 40.0 |
113.783750 | 21.8 | 120.000 | 170.0 | H | -56.0 | 18.8 | 21.7 | 43.5 |
148.097500 | 20.7 | 120.000 | 180.0 | H | -89.0 | 17.7 | 22.8 | 43.5 |
260.860000 | 24.7 | 120.000 | 190.0 | H | -77.0 | 20.8 | 21.3 | 46.0 |
562.893750 | 30.0 | 120.000 | 200.0 | H | 134.0 | 26.5 | 16.0 | 46.0 |
802.483750 | 31.6 | 120.000 | 120.0 | H | 125.0 | 27.9 | 14.5 | 46.0 |
Radiated Emission - Vertical Polarization Measurement Results:
Frequency (MHz) | QuasiPeak (dBμV/m) | Bandwidth (kHz) | Height (cm) | Pol | Azimuth (deg) | Corr. (dB/m) | Margin (dB) | Limit - QPK (dBμV/m) |
---|---|---|---|---|---|---|---|---|
31.212500 | 28.5 | 120.000 | 120.0 | V | -155.0 | 24.3 | 11.5 | 40.0 |
35.820000 | 26.2 | 120.000 | 110.0 | V | -175.0 | 22.0 | 13.8 | 40.0 |
109.176250 | 21.5 | 120.000 | 112.0 | V | -141.0 | 18.5 | 22.0 | 43.5 |
426.002500 | 27.1 | 120.000 | 100.0 | V | -65.0 | 24.0 | 18.9 | 46.0 |
636.977500 | 30.0 | 120.000 | 120.0 | V | -71.0 | 26.5 | 16.1 | 46.0 |
832.190000 | 32.6 | 120.000 | 100.0 | V | 14.0 | 28.5 | 13.5 | 46.0 |
Test Equipment
Key equipment used included a 3m semi-anechoic chamber, EMI test receivers (Rohde & Schwarz ESCI, ESR3), a Bilog antenna (Teseq CBL 6112D), artificial mains networks (Rohde & Schwarz ENV432), and EMC measurement software (Rohde & Schwarz EMC32).
Remarks
Calibration: All test equipment was calibrated according to the laboratory's program, ensuring traceability.
Digital Signature: The document is digitally signed. Verification of legal requirements is the user's responsibility. Information on verifying document authenticity is available at go.tuv.com/digital-signature.
Subcontracting: Test clauses marked with '*' were subcontracted.
Conformity Decision Rule: Based on the "Zero Guard Band Rule" and "Simple Acceptance" per ILAC G8:2019 and IEC Guide 115:2021, measurement uncertainty is not considered.