TÜV Rheinland Test Report: IKEA LED2413G3 Self-Ballasted LED Lamp

Test Report Number: CN24Y8IF 001

Client Reference: 1288983

Client: IKEA of Sweden AB, Box 702, SE-343 81 Älmhult, Sweden

Test Item: Self-ballasted LED lamp

Identification / Type No: LED2413G3

Test Specification: FCC 47 CFR Part 15, Subpart B:2023 Class B, ICES-005:2018

Testing Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.

Test Result: Pass

Tested By: Jessie Xu (Project Engineer)

Authorized By: Hexiong Liu (Authorizer)

Issue Date: 2025-02-18

FCC ID: FHO-LED2413G3

Product Information

Product Function and Intended Use: Ordinary self-ballasted LED lamp for lighting and similar use.

Ratings and System Details: Rated input: AC 120 V, 60 Hz, 47 mA; Rated power: 2.8 W.

Independent Operation Modes: "ON" and "OFF".

Highest Frequency Used: 120 Hz.

Submitted Documents: Circuit diagram, user's manual, and rating label.

Test Setup and Methodology

Test Facilities: TÜV Rheinland (Shanghai) Co., Ltd. located at Workshop14, North Half of Workshop 10 and Workshop 16, Pingqian (Taicang) Modern Industrial Park, No.525, Yuewang Lingang South Road, Shaxi, Taicang, Jiangsu, China. Test equipment is in accordance with CISPR 16-1 series standards.

Test Sequence: Conducted emission tests were performed on 2024-11-06. Radiated emission tests were performed on 2024-11-06.

Test Setup Description:

Test Software: No special test software was used.

Countermeasures: No special measures were employed to achieve EMC compliance.

Conformity Decision Rule

For all EMI tests, compliance is determined by comparing measurement results directly with limits, as measurement uncertainties are within specified values according to ILAC G8:2019 and IEC Guide 115:2021.

Test Results - Conducted Emission (0.15 MHz - 30 MHz)

Result: Passed

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-1.

Limits: Quasi-peak limits range from 56 to 66 dBμV, Average limits range from 46 to 56 dBμV.

Bandwidth: 9 kHz

Input Voltage: AC 120 V, 60 Hz

Ambient Condition: Temperature: 21.5 °C; Relative humidity: 48 %

Expanded Measurement Uncertainty (k=2): 2.33 dB

Minimum Margin: 40.75 dB at 15.321750 MHz.

Quasi-peak measurement results:

Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
0.3547504.8058.8554.051000.09.000L110.3
0.8385005.5956.0050.411000.09.000L110.5
0.9510005.1356.0050.871000.09.000L110.7
4.9290006.7756.0049.231000.09.000L110.3
7.0485007.4460.0052.561000.09.000L110.9
15.32175013.8960.0046.111000.09.000L110.8

Average measurement results:

Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
0.361500-0.6348.6949.321000.09.000L110.3
0.872250-0.6346.0046.631000.09.000L110.6
0.964500-0.3146.0046.311000.09.000L110.7
3.9997500.8546.0045.151000.09.000L110.2
8.0002502.0150.0047.991000.09.000L110.8
15.3217508.4450.0041.561000.09.000L110.8

Conducted Emission (Line N) Measurement Results:

Frequency (MHz) QuasiPeak (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
0.3615004.9458.6953.751000.09.000N10.4
0.7102504.8656.0051.141000.09.000N10.4
1.9905005.2456.0050.761000.09.000N10.5
3.9997506.7956.0049.211000.09.000N10.7
11.9242507.4460.0052.561000.09.000N11.1
15.48150014.6560.0045.351000.09.000N11.1

Average measurement results (Line N):

Frequency (MHz) CAverage (dBuV) Limit (dBuV) Margin (dB) Meas. Time (ms) Bandwidth (kHz) Line Corr. (dB)
0.361500-0.4248.6949.121000.09.000N10.4
0.721500-0.7946.0046.791000.09.000N10.4
2.026500-0.2346.0046.231000.09.000N10.5
3.9997501.3046.0044.701000.09.000N10.7
9.9150002.1450.0047.861000.09.000N11.1
15.3217509.2550.0040.751000.09.000N11.1

Test Results - Radiated Emission (30 MHz - 1000 MHz)

Result: Passed

Test Procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-3.

Product Classification: Class B

Frequency Range: 30 – 1000 MHz

Limits: Quasi-peak limits (3 m distance): 30–88 MHz: 40 dBμV/m; 88–216 MHz: 43.5 dBμV/m; 216–1000 MHz: 46 dBμV/m.

Bandwidth: 120 kHz

Input Voltage: AC 120 V, 60 Hz

Ambient Condition: Temperature: 20.5 °C; Relative humidity: 45 %

Expanded Measurement Uncertainty (k=2): 5.40 dB

Minimum Margin: 11.5 dB at 31.212500 MHz.

Radiated Emission - Horizontal Polarization Measurement Results:

Frequency (MHz) QuasiPeak (dBμV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin (dB) Limit - QPK (dBμV/m)
30.60625027.8120.000200.0H15.024.512.240.0
113.78375021.8120.000170.0H-56.018.821.743.5
148.09750020.7120.000180.0H-89.017.722.843.5
260.86000024.7120.000190.0H-77.020.821.346.0
562.89375030.0120.000200.0H134.026.516.046.0
802.48375031.6120.000120.0H125.027.914.546.0

Radiated Emission - Vertical Polarization Measurement Results:

Frequency (MHz) QuasiPeak (dBμV/m) Bandwidth (kHz) Height (cm) Pol Azimuth (deg) Corr. (dB/m) Margin (dB) Limit - QPK (dBμV/m)
31.21250028.5120.000120.0V-155.024.311.540.0
35.82000026.2120.000110.0V-175.022.013.840.0
109.17625021.5120.000112.0V-141.018.522.043.5
426.00250027.1120.000100.0V-65.024.018.946.0
636.97750030.0120.000120.0V-71.026.516.146.0
832.19000032.6120.000100.0V14.028.513.546.0

Test Equipment

Key equipment used included a 3m semi-anechoic chamber, EMI test receivers (Rohde & Schwarz ESCI, ESR3), a Bilog antenna (Teseq CBL 6112D), artificial mains networks (Rohde & Schwarz ENV432), and EMC measurement software (Rohde & Schwarz EMC32).

Remarks

Calibration: All test equipment was calibrated according to the laboratory's program, ensuring traceability.

Digital Signature: The document is digitally signed. Verification of legal requirements is the user's responsibility. Information on verifying document authenticity is available at go.tuv.com/digital-signature.

Subcontracting: Test clauses marked with '*' were subcontracted.

Conformity Decision Rule: Based on the "Zero Guard Band Rule" and "Simple Acceptance" per ILAC G8:2019 and IEC Guide 115:2021, measurement uncertainty is not considered.

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8211260 Microsoft Word for Microsoft 365; modified using iTextSharp™ 5.5.13.3 ©2000-2022 iText Group NV (AGPL-version)

Related Documents

Preview TÜV Rheinland Test Report for IKEA LED2417G1CF Self-ballasted LED Lamp
This report details the EMC testing conducted by TÜV Rheinland on the IKEA LED2417G1CF self-ballasted LED lamp, covering conducted and radiated emissions according to FCC and ICES standards.
Preview IKEA B2504 LED Lamp EMC Test Report - TÜV Rheinland
This document details the Electromagnetic Compatibility (EMC) testing performed on the IKEA B2504 LED lamp by TÜV Rheinland. It includes conducted and radiated emission test results according to FCC Part 15 Subpart B and ICES-005 standards.
Preview TÜV Rheinland EMC Test Report for IKEA Self-Ballasted LED Lamp (LED2415G1NA)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA Self-Ballasted LED Lamp, model LED2415G1NA. The testing covers conducted and radiated emissions according to FCC 47 CFR Part 15, Subpart B:2023 and ICES-005:2018 standards.
Preview TÜV Rheinland Test Report for IKEA LED Lighting Chain J2506
This document is a TÜV Rheinland test report for the IKEA LED lighting chain, model J2506. It details conducted and radiated emission tests performed according to FCC and ICES standards, including test setup, results, and instrument lists.
Preview TÜV Rheinland Test Report: IKEA LED Lighting Chain (Model J2503)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA LED lighting chain, model J2503. The testing covers conducted and radiated emissions according to FCC 47 CFR Part 15, Subpart B:2022 and ICES-005:2018 standards. It includes test setup descriptions, measurement results, and instrument lists.
Preview TÜV Rheinland EMC Test Report for IKEA LED Light Chain J2504
This report from TÜV Rheinland details the Electromagnetic Compatibility (EMC) testing performed on the IKEA LED light chain (Model J2504) according to FCC Part 15 Subpart B and ICES-005 standards. It includes conducted and radiated emission test results, equipment details, and test setup configurations.
Preview TÜV Rheinland EMC Test Report for IKEA B2411 Portable Luminaire
This document is an EMC test report from TÜV Rheinland for the IKEA B2411 portable general purpose luminaire. It details conducted and radiated emission test results against FCC and ICES standards, confirming compliance.
Preview TÜV Rheinland EMC Test Report for IKEA LED Bulb (LED2420G1CF)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on an IKEA LED Bulb (Model: LED2420G1CF). The tests included conducted and radiated emissions, performed according to FCC Part 15 and ICES standards, with results indicating compliance.