TÜV Rheinland Test Report - IKEA B2504 LED Lamp

Report Number: CN25G6G5 001

Client: IKEA of Sweden AB

Product: LED lamp

Type No.: B2504

FCC ID: FHO-B2504

Testing Laboratory: TÜV Rheinland (Shanghai) Co., Ltd.

Issue Date: 2025-06-07

Remarks

1. All test equipment used was calibrated according to the laboratory's calibration program and fulfills relevant standard requirements. Traceability is ensured by the management system. Detailed information on test conditions, equipment, and measurement uncertainty is available upon request.

2. This document is digitally signed. TÜV Rheinland has not verified, nor is it able to verify, legal or other requirements applicable to this document. Such verification is the user's responsibility. Upon client request, TÜV Rheinland can confirm digital signature validity via a separate document, subject to an environmental fee. For verification information, visit: go.tuv.com/digital-signature.

3. Test clauses marked with '*' were subcontracted. Deviations from test specifications or customer requirements are listed in the respective test clause.

4. The decision rule for conformity statements is based on the "Zero Guard Band Rule" and "Simple Acceptance" per ILAC G8:2019 and IEC Guide 115:2021, unless otherwise specified. Measurement uncertainty is not accounted for in the report.

General Product Information

The Equipment Under Test (EUT) is an ordinary LED lamp for lighting and similar use.

ParameterValue
Rated input5 V DC, 1.5 W
Protection classClass III
Highest frequency generated or used4 kHz

Operation Modes:

Submitted Documents: Circuit diagram, user's manual, and rating label.

Test Set-up and Operation Modes

Principle of Configuration Selection: The EUT was configured to measure its highest possible emission level. Test conditions were adapted according to the instructions for use.

Sequence of Testing: Conducted emission tests were performed on 2025-05-22. Radiated emission tests were performed on 2025-05-29.

Equipment and Cable Arrangement:

Conducted Emission Setup: A block diagram shows the EUT connected to a Line Impedance Stabilization Network (LISN), which is connected to an EMI receiver and a computer. A transformer and power supply are also part of the setup.

Radiated Emission Setup: A block diagram illustrates the EUT placed on a support, with an antenna positioned at a distance (1-4m) and connected to an EMI receiver.

Test Software: No special test software was used.

Special Accessories and Auxiliary Equipment: Adaptor (model: ICPSW5-5NA-1, brand: IKEA) and Laptop (model: T45, brand: IKEA) were used as power supply.

Countermeasures to achieve EMC Compliance: No special measures were employed.

Conformity Decision Rule

For all EMI tests, compliance is determined by directly comparing measurement results with corresponding limits, as measurement uncertainties are less than the values specified in CISPR 16-4-2.

Test Results: Emission

Conducted Emission (0.15 MHz – 30 MHz)

Date of testing: 2025-05-22

Test procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-1

Frequency range: 0.15 – 30 MHz

Limits: Quasi-peak: 0.15-0.5 MHz (66 to 56 dBμV), 0.5-5 MHz (56 dBμV), 5-30 MHz (60 dBμV). Average: 0.15-0.5 MHz (56 to 46 dBμV), 0.5-5 MHz (46 dBμV), 5-30 MHz (50 dBμV).

Bandwidth of EMI receiver: 9 kHz

Kind of test site: Shielded room

Input voltage: AC 120 V, 60 Hz

Ambient condition: Temperature: 23.8 °C; Relative humidity: 57.1 %

Expanded measurement uncertainty (k=2): 2.33 dB

The minimum margin to the limit was 10.15 dB. The margin is higher than the expanded measurement uncertainty.

Mode 1 (Power Supply):

Final Quasi-Peak Measurement Results (Mode 1, Line L1)

Frequency (MHz)QuasiPeak (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.15675048.8565.6316.78L110.6
0.37950038.0758.2920.22L110.5
0.42000038.0357.4519.42L110.5
0.46050035.4456.6821.24L110.5
0.49875042.5456.0213.48L110.5
0.53475036.6056.0019.40L110.5

Final Average Measurement Results (Mode 1, Line L1)

Frequency (MHz)CAverage (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.42000024.0547.4523.39L110.5
0.45825025.0546.7221.68L110.5
0.49875033.5146.0212.51L110.5
0.53700027.8046.0018.20L110.5
0.99825021.4846.0024.52L110.5
18.06900024.6850.0025.32L111.1

Mode 1 (Power Supply):

Final Quasi-Peak Measurement Results (Mode 1, Line N)

Frequency (MHz)QuasiPeak (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.15675047.3765.6318.27N10.3
0.37725037.7558.3420.59N10.3
0.41775039.0757.4918.43N10.3
0.45825035.2556.7221.48N10.3
0.49875040.4856.0215.54N10.3
0.53700038.0156.0017.99N10.3

Final Average Measurement Results (Mode 1, Line N)

Frequency (MHz)CAverage (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.15900027.8955.5227.62N10.3
0.42000021.7547.4525.70N10.3
0.45825022.6146.7224.11N10.3
0.49875030.1346.0215.89N10.3
0.53700024.7246.0021.28N10.3
18.10050022.2950.0027.71N11.0

Mode 2 (Laptop):

Final Quasi-Peak Measurement Results (Mode 2, Line L1)

Frequency (MHz)QuasiPeak (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.16350055.1465.2810.15L110.6
0.58875037.1656.0018.84L110.5
1.11525034.4456.0021.56L110.5
2.32125037.4256.0018.58L110.6
6.76500034.5360.0025.47L110.7
16.27575045.4660.0014.54L111.1

Final Average Measurement Results (Mode 2, Line L1)

Frequency (MHz)CAverage (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.19275038.3953.9215.53L110.5
0.46725027.5846.5618.98L110.5
0.58875026.7946.0019.21L110.5
0.78225027.6246.0018.38L110.5
3.12675026.6646.0019.34L110.6
16.24200035.8050.0014.20L111.1

Mode 2 (Laptop):

Final Quasi-Peak Measurement Results (Mode 2, Line N)

Frequency (MHz)QuasiPeak (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.17025054.3564.9510.60N10.3
0.47175035.1156.4821.37N10.3
0.54375034.4856.0021.52N10.3
0.60000032.7456.0023.26N10.3
2.29875033.7056.0022.30N10.4
16.11600043.4060.0016.60N10.9

Final Average Measurement Results (Mode 2, Line N)

Frequency (MHz)CAverage (dBuV)Limit (dBuV)Margin (dB)LineCorr. (dB)
0.17475038.1254.7316.61N10.3
0.47625022.1046.4024.31N10.3
0.53700024.9246.0021.08N10.3
0.78225025.1846.0020.82N10.3
1.56300022.4146.0023.59N10.4
16.17000034.2450.0015.76N10.9

Radiated Emission (30 MHz – 1000 MHz)

Date of testing: 2025-05-29

Test procedure: FCC 47 CFR Part 15, Subpart B:2023, ICES-005:2018, ANSI C63.4-2014 and CISPR 16-2-3

Product classification: Class B

Frequency range: 30 – 1000 MHz

Limits (3 m distance): Quasi-peak: 30-88 MHz (40 dBμV/m), 88-216 MHz (43.5 dBμV/m), 216-1000 MHz (46 dBμV/m).

Bandwidth of EMI receiver: 120 kHz

Kind of test site: Semi-anechoic chamber

Input voltage: AC 120 V, 60 Hz

Ambient condition: Temperature: 21.1 °C; Relative humidity: 55.3 %

Expanded measurement uncertainty (k=2): 5.40 dB

The minimum margin to the limit was 6.0 dB. The margin is higher than the expanded measurement uncertainty.

Mode 1 (Power Supply):

Final Quasi-Peak Measurement Results (Mode 1, Horizontal Polarization)

Frequency (MHz)QuasiPeak (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - QPK (dB)Limit - QPK (dBμV/m)
67.58750023.31000.0120.000198.0H133.012.816.740.0
173.43875025.31000.0120.000180.0H-87.016.518.243.5
276.38000032.21000.0120.000116.0H41.020.013.846.0
288.14125034.81000.0120.000100.0H96.019.911.246.0
299.78125031.91000.0120.000145.0H6.020.314.146.0
324.15250034.01000.0120.000163.0H-10.020.912.046.0

Mode 1 (Power Supply):

Final Quasi-Peak Measurement Results (Mode 1, Vertical Polarization)

Frequency (MHz)QuasiPeak (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - QPK (dB)Limit - QPK (dBμV/m)
33.75875033.71000.0120.000186.0V-28.023.56.340.0
34.85000034.01000.0120.000172.0V4.022.96.040.0
42.48875032.61000.0120.000132.0V-60.018.67.440.0
66.49625022.81000.0120.000130.0V133.012.817.240.0
173.31750032.01000.0120.000159.0V173.016.511.543.5
179.86500029.11000.0120.000150.0V-141.016.214.443.5

Mode 2 (Laptop):

Final Quasi-Peak Measurement Results (Mode 2, Horizontal Polarization)

Frequency (MHz)QuasiPeak (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - QPK (dB)Limit - QPK (dBμV/m)
54.49250026.41000.0120.000196.0H-37.013.413.640.0
55.58375033.71000.0120.000144.0H109.013.26.340.0
57.76625020.91000.0120.000126.0H139.012.919.140.0
59.94875020.41000.0120.000157.0H151.012.719.640.0
172.46875025.91000.0120.000107.0H9.016.217.643.5
276.01625036.31000.0120.000144.0H25.019.89.746.0

Mode 2 (Laptop):

Final Quasi-Peak Measurement Results (Mode 2, Vertical Polarization)

Frequency (MHz)QuasiPeak (dBμV/m)Meas. Time (ms)Bandwidth (kHz)Height (cm)PolAzimuth (deg)Corr. (dB/m)Margin - QPK (dB)Limit - QPK (dBμV/m)
54.49250024.31000.0120.000182.0V137.013.415.740.0
55.58375033.81000.0120.000132.0V87.013.26.240.0
56.67500026.91000.0120.000155.0V-54.013.013.140.0
57.64500017.81000.0120.000184.0V-40.012.922.240.0
172.34750032.51000.0120.000108.0V-147.016.211.043.5
176.71250034.81000.0120.000104.0V-34.016.18.743.5

List of Test and Measurement Instruments

Equip. no.Equipment nameModelSerial no.ManufacturerCal. dateDue date
EMC-C-190Artificial mains networkENV432101514Rohde & Schwarz2024-10-112025-10-11
EMC-S-028EMI measurement softwareEMC32-E+ (10.60.20)100150Rohde & SchwarzN/AN/A
EMC-C-366Thermohygrometer608-H12485149174testo2024-07-262025-07-26
EMC-C-195EMI test receiverESR3102794Rohde & Schwarz2024-08-032025-08-03
EMC-S-032EMI measurement softwareEMC32-MEB (10.60.20)100697Rohde & SchwarzN/AN/A
EMC-C-155BiLog antennaCBL 6112D40530Teseq2025-03-242026-03-24
EMC-C-121Thermohygrometer608-H11241320265testo2024-06-252025-06-25
EMC-C-066EMI test receiverESCI100280Rohde & Schwarz2024-10-172025-10-17
EMC-C-0013 m semi-anechoic chamberSAC3FJ129002Frankonia2023-12-032026-12-03

List of Figures

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8407296 Microsoft Word for Microsoft 365; modified using iTextSharp™ 5.5.13.3 ©2000-2022 iText Group NV (AGPL-version)

Related Documents

Preview TÜV Rheinland EMC Test Report for IKEA Self-Ballasted LED Lamp (LED2415G1NA)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA Self-Ballasted LED Lamp, model LED2415G1NA. The testing covers conducted and radiated emissions according to FCC 47 CFR Part 15, Subpart B:2023 and ICES-005:2018 standards.
Preview TÜV Rheinland EMC Test Report for IKEA LED Light Chain J2504
This report from TÜV Rheinland details the Electromagnetic Compatibility (EMC) testing performed on the IKEA LED light chain (Model J2504) according to FCC Part 15 Subpart B and ICES-005 standards. It includes conducted and radiated emission test results, equipment details, and test setup configurations.
Preview TÜV Rheinland EMC Test Report for IKEA LED Bulb (LED2420G1CF)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on an IKEA LED Bulb (Model: LED2420G1CF). The tests included conducted and radiated emissions, performed according to FCC Part 15 and ICES standards, with results indicating compliance.
Preview TÜV Rheinland Test Report for IKEA LED Bulb (Model: LED2420G1NA)
This document is an EMC test report by TÜV Rheinland for IKEA's LED Bulb (Model: LED2420G1NA). It details conducted and radiated emission tests performed according to FCC 47 CFR Part 15, Subpart B:2023 and ICES-005:2018 standards, confirming compliance.
Preview TÜV Rheinland EMC Test Report for IKEA B2411 Portable Luminaire
This document is an EMC test report from TÜV Rheinland for the IKEA B2411 portable general purpose luminaire. It details conducted and radiated emission test results against FCC and ICES standards, confirming compliance.
Preview TÜV Rheinland Test Report for IKEA LED2417G1CF Self-ballasted LED Lamp
This report details the EMC testing conducted by TÜV Rheinland on the IKEA LED2417G1CF self-ballasted LED lamp, covering conducted and radiated emissions according to FCC and ICES standards.
Preview TÜV Rheinland Test Report: IKEA LED Lighting Chain (Model J2503)
This report details the Electromagnetic Compatibility (EMC) testing conducted by TÜV Rheinland on the IKEA LED lighting chain, model J2503. The testing covers conducted and radiated emissions according to FCC 47 CFR Part 15, Subpart B:2022 and ICES-005:2018 standards. It includes test setup descriptions, measurement results, and instrument lists.
Preview IKEA LED2414G2 EMC Test Report - Conducted and Radiated Emissions
This report details the Electromagnetic Compatibility (EMC) testing conducted on the IKEA LED2414G2 self-ballasted LED lamp, covering conducted and radiated emissions according to FCC and ICES standards.