Goodman GRVT80 / GDVT80 Two-Stage, Variable-Speed ECM Gas Furnace
Heating Input: 60,000–100,000 BTU/H
Product Overview
The Goodman GRVT80 and GDVT80 series are two-stage, variable-speed ECM gas furnaces designed for efficient and quiet heating. These furnaces feature an 80% AFUE rating and are equipped with Goodman's ComfortBridge™ and CoolCloud™ technologies for advanced control and diagnostics.
Standard Features
- Integrated communicating ComfortBridge™ technology
- Two-stage gas valve for quiet, economical heating
- On-board Bluetooth for commissioning and diagnostics via the CoolCloud™ phone and tablet application
- Efficient and quiet variable-speed ECM circulator motor that ramps up or down according to heating or cooling demand
- SureStart® Silicon Nitride igniter for long igniter life
- Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
- Low constant fan speed circulates air throughout the home
- Quiet, two-speed induced draft blower
- California Low NOx emissions-compliant models available
- AHRI Certified; ETL Listed
Cabinet Features
- Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish
- Multi-position installation: GRVT80 (upflow, horizontal left or right), GDVT80 (downflow, horizontal left or right)
- Removable bottom for side- or bottom-return applications
- Convenient left or right connection for gas/electric service
- Cabinet air leakage ≤ 2%
- Coil and furnace fit flush for most installations
Nomenclature Breakdown
The model number provides detailed information about the furnace's features:
- Brand: G - Goodman
- Configuration: R - Upflow/Horizontal, D - Downflow/Horizontal
- Motor: 9 - Nine Speed ECM, V - Variable Speed ECM
- Gas Valve: T - Two Stage, S - Single Stage, M - Modulating
- AFUE: 80 - 80% AFUE, 92 - 92% AFUE, 96 - 96% AFUE, 97 - 97% AFUE
- NOx: N - Natural Gas, N - Low NOx (90%+), X - Low NOx (80%), U - Ultra Low NOx
- Cabinet Width: A - 14", B - 17½", C - 21", D - 24½"
- MBTU/H: Indicates heating capacity (e.g., 060 = 60,000 BTU/h, 100 = 100,000 BTU/h)
- Maximum CFM: Indicates maximum airflow (e.g., 3 - 1200 CFM, 4 - 1600 CFM, 5 - 2000 CFM)
Specifications Summary
The following tables summarize key specifications for various models:
GRVT80 Series Specifications
Model | Heating Capacity (BTU/h) | AFUE | Circulator Blower Size (D x W) | Min. Circuit Ampacity | Ship Weight (LBS) |
---|---|---|---|---|---|
GRVT800603B* | 60,000 | 80 | 10" x 8" | 7.6 | 105 |
GRVT800604B* | 60,000 | 80 | 10" x 8" | 10.8 | 107 |
GRVT800803B* | 80,000 | 80 | 10" x 8" | 7.6 | 110 |
GRVT800804C* | 80,000 | 80 | 11" x 10" | 7.6 | 118 |
GRVT800805C* | 80,000 | 80 | 10" x 10" | 10.8 | 121 |
GRVT800805D* | 80,000 | 80 | 11" x 10" | 10.8 | 129 |
GRVT801005C* | 100,000 | 80 | 10" x 10" | 10.8 | 124 |
GDVT80 Series Specifications
Model | Heating Capacity (BTU/h) | AFUE | Circulator Blower Size (D x W) | Min. Circuit Ampacity | Ship Weight (LBS) |
---|---|---|---|---|---|
GDVT800603BX* | 60,000 | 80 | 10" x 8" | 7.6 | 105 |
GDVT800803BX* | 80,000 | 80 | 10" x 8" | 7.6 | 109 |
GDVT800805CX* | 80,000 | 80 | 10" x 10" | 10.8 | 125 |
GDVT801005CX* | 100,000 | 80 | 10" x 10" | 10.8 | 129 |
Dimensions
The furnaces are available in various widths to accommodate different installation requirements. Refer to the diagrams for detailed dimensions and minimum clearances to combustible materials.
GRVT80 Dimensions
Model | W | D | H | A | B |
---|---|---|---|---|---|
GRVT800603B** | 17½" | 28" | 33%" | 17½" | 16" |
GRVT800604B** | 17½" | 28" | 33%" | 17½" | 16" |
GRVT800803B** | 17½" | 28" | 33%" | 17½" | 16" |
GRVT800804C** | 21" | 28" | 33%" | 21" | 19½" |
GRVT800805C** | 21" | 28" | 33%" | 21" | 19½" |
GRVT800805D** | 24½" | 28" | 33%" | 24½" | 23" |
GRVT801005C** | 21" | 28" | 33%" | 21" | 19½" |
GDVT80 Dimensions
Model | W | D | H | A | B |
---|---|---|---|---|---|
GDVT800603BX* | 17½" | 28" | 33%" | 17½" | 16" |
GDVT800803BX* | 17½" | 28" | 33%" | 17½" | 16" |
GDVT800805CX* | 21" | 28" | 33%" | 21" | 19½" |
GDVT801005CX* | 21" | 28" | 33%" | 21" | 19½" |
Minimum Clearances to Combustible Materials
SIDES | REAR | FRONT | BOTTOM | VENT SW | VENT B | TOP | |
---|---|---|---|---|---|---|---|
GRVT80 | 1" | 0" | 3" | C | 6" | 1" | 1" |
GDVT80 | 1" | 0" | 3" | 6" | 1" | 1" |
Notes:
- For servicing or cleaning, a 24" front clearance is recommended.
- Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above.
- In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
- Refer to the appropriate USA and Canadian codes: In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1. In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2.
- C = If placed on combustible floor, the floor MUST be wood ONLY.
Airflow Data
The following tables provide airflow data (CFM) and temperature rise (RISE) for various operating conditions and cooling speeds.
Airflow Data (Mid Rise)
Model/Temp Rise Range (Mid Rise) | GDVT800603BXA* | GDVT800803BXA* | GDVT800805CXA* | GDVT801005CXA* | GRVT800603B*A* | GRVT800604B*A* | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | |
Recommended cfm for high heat / expected temperature rise | 1100 | 40 | 1325 | 45 | 1470 | 40 | 2090 | 35 | 1400 | 32 | 1275 | 35 |
Lowest recommended cfm for hi heat/ expected temperature rise | 810 | 55 | 990 | 60 | 1070 | 55 | 1475 | 50 | 980 | 45 | 890 | 50 |
Model/Temp Rise Range (Mid Rise) | GRVT800803B*A* | GRVT800804C*A* | GRVT800805C*A* | GRVT800805D*A* | GRVT801005C*A* | |||||
---|---|---|---|---|---|---|---|---|---|---|
CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | |
Recommended cfm for high heat / expected temperature rise | 1330 | 45 | 1400 | 42 | 1700 | 35 | 1700 | 35 | 1850 | 40 |
Lowest recommended cfm for hi heat / expected temperature rise | 980 | 60 | 1090 | 54 | 1175 | 50 | 1175 | 50 | 1350 | 55 |
Cooling Speed Airflow
GRVT800603B*A*, GRVT800803B*A*, GDVT800603BXA*, GDVT800803BXA* Cooling Speed (@0.1" - 0.8" w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
---|---|---|
1.5 | 600 | 420 |
2 | 800 | 560 |
2.5 | 1,000 | 700 |
3 | 1,200 | 840 |
4 | 1,600 | 1,120 |
MAX | 1,400 |
GRVT800604B*A*, GRVT800804C*A* Cooling Speed (@0.1" - 0.8" w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
---|---|---|
2 | 800 | 560 |
2.5 | 1,000 | 700 |
3 | 1,200 | 840 |
MAX | 1,760 |
GDVT800805CXA*, GDVT801005CXA* Cooling Speed (@0.1" - 0.8" w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
---|---|---|
2 | 800 | 560 |
3 | 1,200 | 840 |
4 | 1,600 | 1,120 |
5 | 2,000 | 1,400 |
MAX | 2,000 |
GRVT800805C*A*, GRVT800805D*A*, GRVT801005C*A* Cooling Speed (@0.1" - 0.8" w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
---|---|---|
2 | 800 | 560 |
3 | 1,200 | 840 |
4 | 1,600 | 1,120 |
5 | 2,000 | 1,400 |
MAX | 2,200 |
Note: All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 CFM per ton when cooling is desirable. Do not operate above 0.5" w.c. ESP in heating mode. Operating CFM between 0.5" and 0.8" w.c. is tabulated for cooling purposes only.
Wiring Diagram and Controls
The wiring diagram illustrates the electrical connections for the furnace components, including pressure switches, igniter, gas valve, limit controls, and blower motor. It also details low voltage and high voltage wiring. Instructions are provided for menu navigation and selection using both the CoolCloud™ phone application and on-board push buttons. Airflow settings for non-communicating installations can be adjusted via the Tonnage and Cooling Trim menus.
Accessories
Various accessories are available for the GRVT80 and GDVT80 series, including:
- Fossil Fuel (Dual Fuel) Kits
- High-Altitude Kits
- LP Conversion Kits
- Downflow Sub-Bases
Warranty Information
Goodman offers a Lifetime Heat Exchanger Limited Warranty, a 10-Year Unit Replacement Limited Warranty, and a 10-Year Parts Limited Warranty. Online registration is required within 60 days of installation to receive these warranties. Specific warranty details and limitations apply.
Notes
Goodman's commitment to quality products may result in specification changes without notice. All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. Gas service connection is ½" FPT. It is important to size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and local codes.