Heating Input: 40,000­120,000 BTU/h

GR9S96 / GD9S96
Single-Stage, Multi-Speed ECM Gas Furnace Up to 97% AFUE
Contents
Nomenclature............................................. 2 Product Specifications................................ 3 Dimensions................................................. 5 Airflow Specifications.................................7 Wiring Diagram.. .......................................13 Accessories...............................................14

Standard Features · Heavy-duty aluminized-steel tubular heat exchanger · Stainless-steel secondary heat exchanger · Single-stage gas valve · Durable Silicon Nitride igniter · Quiet single-speed induced draft blower · Self-diagnostic control board with constant
memory fault code history output to a LED · All models comply with California 40 ng/J
Low NOx emissions standard · Can not be installed in California's South Coast
AirQuality Management District (SCAQMD) and San Joaquin Valley Air Pollution Control District (SJVAPCD). · AHRI Certified; ETL Listed

Cabinet Features · Designed for multi-position installation --
GR9S96: upflow, horizontal left or right GD9S96: downflow, horizontal left or right · Certified for direct vent (2-pipe) or non-direct vent (1-pipe) · Easy-to-install top venting with optional side venting · Convenient left or right connection for gas and electrical service · Cabinet air leakage (QLeak)  2% · Heavy-gauge steel cabinet with durable finish · Fully insulated heat exchanger and blower section · Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications

SS-GR9S96_GD9S96-R32

* Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. The duration of warranty coverage in Texas and Florida differs in some cases.

www.goodmanmfg.com

08/24
Supersedes 05/24

Nomenclature

G

R

9

S

96 040

4

C

*

**

1

2

3

4

5,6 7,8,9 10

11

12 13,14

Brand G - Goodman® Brand
Configuration R - Upflow/Horizontal D - Downflow/Horizontal

Engineering
Major/Minor Revisions
A - Initial Release B - 1st Revision
NOx
N = < 40 NG/J NOx

Motor 9 - Nine Speed ECM
Gas Valve T - 2 Stage S - 1 Stage

Cabinet Width

A - 14"

C - 21"

B - 17½" D - 24½"

3 - 1200 CFM

Maximum CFM 4 - 1600 CFM 5 - 2000 CFM

AFUE 80 - 80% AFUE 92 - 92% AFUE 96 - 96% AFUE*** 97 - 97% AFUE
*** Some models are rated up to 97% AFUE

030 - 30,000 BTU/h 040 - 40,000 BTU/h 060 - 60,000 BTU/h

MBTU/h 080 - 80,000 BTU/h 100 - 100,000 BTU/h 120 - 120,000 BTU/h

2

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32

GR9S96 Product Specifications

Heating Data High Fire Input¹ High Fire Output¹ AFUE² Temperature Rise Range (°F) Vent Diameter³ No. of Burners Circulator Blower Available AC @ 0.5" ESP Size (D x W) Horsepower @ 1075 RPM Speed
Filter Size (in²) (Qty)
Electrical Data Min. Circuit Ampacity Max. Overcurrent Device (amps)
Shipping Weight (lbs)

GR9S96 0403AN

GR9S96 0603BN

GR9S96 0803BN

GR9S96 0804CN

GR9S96 0805CN

GR9S96 1005CN

GR9S96 1205DN

40,000 38,800
97 25-55 2" - 3"
2

60,000 58,200
97 30-60 2" - 3"
3

80,000 76,880
96 35-65 2" - 3"
4

80,000 77,600
97 25-55 2" - 3"
4

80,000 77,600
97 25-55 2" - 3"
4

100,000 96,100
96 30-60 2" - 3"
5

120,000 115,320
96 35-65
3" 6

1.5 - 3
11" x 6"
1/2
9
(1) 16 X 25 (side) or (1) 14 X 25 (bottom)

1.5 - 3 11" x 8"
1/2 9
(1) 16 X 25 (side or bottom)

1.5 - 3 11" x 8"
1/2 9
(1) 16 X 25 (side or bottom)

1.5 - 4 11" x 10"
3/4 9
(1) 16 X 25 (side or bottom)

3 - 5
11" x 10"
1
9
(1) 20 x 25 (bottom) or (2) 16 x 25
(side)

3 - 5
11" x 10"
1
9
(1) 20 x 25 (bottom) or (2) 16 x 25
(side)

3 - 5
11" x 11"
1
9
(1) 20 x 25 (bottom) or (2) 16 x 25
(side)

9.7

10.1

10.1

13.7

16.7

16.7

16.7

15

15

15

20

25

25

25

108

118

118

141

142

144

156

ENERGY STAR® Certified
¹ Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4% for each 1000' above 4500' altitude ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon
furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.  Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.  Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes · All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. · Gas Service Connection ½" FPT · Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. · For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. · For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements.

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

3

GD9S96 Specifications

Heating Data High Fire Input¹ High Fire Output¹ AFUE² Temperature Rise Range (°F) Vent Diameter³ No. of Burners Circulator Blower Available AC @ 0.5" ESP Size (D x W) Horsepower @ 1075 RPM Speed
Filter Size (in²) (Qty)
Electrical Data Min. Circuit Ampacity Max. Overcurrent Device (amps) Shipping Weight (lbs)

GD9S96 0403BN
40,000 38,440
96 25-55 2" - 3"
2
1.5 - 3 11" x 8"
1/2 9 (2) 10 x 20 or (1) 16 x 25 (top return)
10.1 15 113

GD9S96 0603BN
60,000 57,660
96 35-65 2" - 3"
3
1.5 - 3 11" x 8"
1/2 9 (2) 10 x 20 or (1) 16 x 25 (top return)
10.1 15 116

GD9S96 0804CN

GD9S96 1005CN

GD9S96 1205DN

80,000 76,880
96 40-70 2" - 3"
4

100,000 95,000
95 40-70 2" - 3"
5

120,000 115,320
96 45-75
3" 6

2.5 - 4 11" x 10"
3/4 9
(2) 10 x 20 or (1) 16 x 25 (top return)

3 - 5

3 - 5

11" x 10"

11" x 11"

1

1

9

9

(1) 14 x 20 (bottom) or
(1) 20 x 25 (top return)

(1) 14 x 20 (bottom) or
(1) 20 x 25 (top return)

13.7

16.7

16.7

20

25

25

141

144

156

ENERGY STAR® Certified
¹ Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4% for each 1000' above 4500' altitude ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending
upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.  Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.  Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes · All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. · Gas Service Connection ½" FPT · Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. · For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. · For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances
listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements.

4

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32

GR9S96 Dimensions

Air Discharge
28¾ Air Intake
2" Pipe Left-Side
Drain Trap Exterior Holes
14
1½ LEFT SIDE VIEW Low-voltage Electrical Outlet
1 23

Air Discharge

6½ 2¾

2

2

Center Dimple

For Alternate

Air Intake Pipe

3" OD Hole

High-Voltage Electrical Outlet

Standard Gas Supply Location

34½
31
24 23 19

9¼ 5

1 2
2½
Condensate Drain Trap Exterior Connection
(Right or Left Side) ¾ PVC

A

B

¾

C

1

6½ 2

¾ 19½

Vent/ Flue Pipe 2" PVC
¾

Alternate Vent/ Flue Location

Right-Side Drain Trap Exterior Holes

High-Voltage Electrical Outlet

Alternate Gas Supply

FRONT VIEW
D Unfolded Flanges
E Folded Flanges

26½ 23 21 19
9¼ 5
 Low-Voltage
Electrical Outlet

1 RIGHT SIDE VIEW
2 2½
22 Unfolded Flanges
23½ Folded Flanges

Model
GR9S960403AN GR9S960603BN GR9S960803BN GR9S960804CN GR9S960805CN GR9S961005CN GR9S961205DN

AIR DISCHARGE

A

B

C

14"

12½"

10½"

17½

16"

13"

17½

16"

13"

21"

19½"

17

21"

19½"

17

21"

19½"

17

24½

23"

20"

D 8" 12" 12" 16" 16" 16" 19"

AIR DISCHARGE E
10" 13" 13" 17½" 17½" 17½" 20"

Minimum Clearances to Combustible Materials

Position

Sides

Rear

Front

Bottom

Flue

Top

Upflow

0"

0"

1"

C

0"

1"

Horizontal

6"

0"

ALCOVE

C

0"

4"

C = If placed on combustible floor, the floor MUST be wood ONLY.

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

5

GD9S96 Dimensions

1

23

1½

14

Drain Trap Holes Standard Drain Trap
28¾
Air Discharge

2 1
Low-Voltage Electrical Outlet Alternate Gas High-Voltage Electrical Outlet
34½
25 14¾ 11 6 4
2 2½ 3½

A

6½

B

C

1

2½

1

Low-Voltage Electrical Outlet

Alternate Gas Supply
25

D Unfolded Flanges
E Folded Flanges
Front View

14 14¾ 11 6
High-Voltage Electrical Outlet
2 2 Right Side Exterior Drain Trap Holes

18¼ Alternate Vent/
18 Unfolded Flanges
20 Folded Flanges Right-Side View
Air Discharge

Model
GD9S960403BN GD9S960603BNA GD9S960804CN GD9S961005CN GD9S961205DN

AIR DISCHARGE

A

B

C

17½

16"

13"

17½

16"

13"

21"

19½"

17

21"

19½"

17

24½

23"

20"

D 12" 12" 16" 16" 19"

AIR DISCHARGE E
13" 13" 17½" 17½" 20"

Minimum Clearances to Combustible Materials

Position

Sides

Rear

Front

Bottom

Flue

Top

Downflow

0"

0"

1"

NC

0"

1"

Horizontal

6"

0"

ALCOVE

C

0"

4"

C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.

6

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32

GR9S96 Heating Airflow Data

CFM & Temperature Rise vs. External Static Pressure

Model
GR9S96 0403A*
GR9S96 0603B*
GR9S96 0803B*
GR9S96 0804C*
GR9S96 0805C*
GR9S96 1005C*
GR9S96 1205D*

THERMOSTAT CALL

TAP #

W/W1 W/W1 W/W1 W/W1 W/W1 W/W1 W/W1

F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04^^

0.1 CFM Rise 705 50 1079 33 915 39 887 40 758 N/A 1218 44 1164 46 1121 48 715 N/A 1415 50 1388 51 1290 55 1019 N/A 1791 40 1625 44 1537 46 1029 N/A 1814 39 1893 38 1738 41 1008 N/A 2026 44 1921 46 1804 49 1118 N/A 2143 50 2025 53 1906 56

External Static Pressure, (Inches Water Column)

0.2

0.3

0.4

0.5

CFM Rise CFM Rise CFM Rise CFM Rise

661 54 617 N/A 564 N/A 509 N/A

1055 34 1027 35 994 36 965 37

881 40 846 42 814 44 780 46

855 42 823 43 790 45 751 47

696 N/A 636 N/A 572 N/A 512 N/A

1178 45 1140 47 1100 48 1060 50

1123 47 1084 49 1042 51 1003 53

1083 49 1041 51 996 54 953 56

658 N/A 589 N/A 524 N/A 465 N/A

1385 51 1355 52 1322 54 1291 55

1360 52 1325 54 1291 55 1259 57

1252 57 1215 59 1182 60 1143 62

952 N/A 878 N/A 796 N/A 706 N/A

1743 41 1700 42 1663 43 1626 44

1559 46 1512 47 1468 48 1425 50

1490 48 1447 49 1403 51 1354 53

959 N/A 890 N/A 811 N/A 727 N/A

1766 40 1722 41 1679 42 1637 43

1844 39 1803 39 1763 40 1723 41

1680 42 1637 43 1596 45 1554 46

934 N/A 855 N/A 779 N/A 702 N/A

1981 45 1929 46 1901 47 1858 48

1879 47 1840 48 1791 50 1751 51

1755 51 1710 52 1664 53 1619 55

1035 N/A 952 N/A 860 N/A 750 N/A

2095 51 2047 52 2002 53 1954 55

1977 54 1930 55 1897 56 1848 58

1877 57 1828 58 1778 60 1726 62

0.6 0.7 0.8 CFM CFM CFM 455 405 362 935 906 863 737 695 652 705 666 608 460 412 354 1016 977 937 960 920 871 906 861 818 412 360 279 1255 1219 1186 1223 1191 1157 1107 1071 1032 619 542 485 1583 1538 1489 1370 1325 1271 1301 1247 1190 647 579 511 1595 1555 1511 1685 1641 1604 1510 1469 1420 628 557 493 1819 1773 1733 1705 1656 1610 1574 1526 1479 663 590 519 1891 1850 1802 1798 1750 1703 1674 1622 1568

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

7

GR9S96 Cooling & Circulation Airflow

MODEL
GR9S96 0403A*
GR9S96 0603B*
GR9S96 0803B*
GR9S96 0804C*
GR9S96 0805C*

THERMOSTAT CALL

TAP #

F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09

0.1 CFM 705 1079 915 887 1135 1189 1266 1313 1342 758 1218 1164 1121 902 960 1273 1335 1427 715 1415 1388 1290 916 985 1118 1191 1471 1019 1791 1625 1537 1289 1431 1836 1919 1952 1029 1814 1893 1738 1193 1421 1582 1962 2068

0.2 CFM 661 1055 881 855 1106 1163 1243 1288 1324 696 1178 1123 1083 851 917 1240 1301 1390 658 1385 1360 1252 867 940 1078 1153 1440 952 1743 1559 1490 1234 1375 1784 1890 1921 959 1766 1844 1680 1135 1369 1536 1919 2024

EXTERNAL STATIC PRESSURE (INCHES WATER COLUMN)

0.3 0.4

0.5

0.6

0.7

CFM CFM CFM Watts CFM Watts CFM Watts

617 564 509 103 455 108 405 115

1027 994 965 256 935 264 906 271

846 814 780 174 737 180 695 186

823 790 751 164 705 170 666 176

1078 1049 1021 281 994 290 965 299

1138 1111 1085 321 1059 331 1032 341

1218 1197 1172 372 1148 383 1123 394

1261 1239 1215 403 1189 412 1165 422

1305 1280 1263 440 1239 452 1216 463

636 572 512 104 460 110 412 115

1140 1100 1060 275 1016 284 977 292

1084 1042 1003 249 960 258 920 268

1041 996 953 230 906 236 861 245

801 746 689 145 637 153 585 158

864 812 764 164 708 171 661 179

1207 1171 1128 309 1089 318 1051 327

1266 1228 1192 347 1154 356 1118 365

1362 1327 1297 408 1260 414 1224 423

589 524 465 93 412 99 360 104

1355 1322 1291 394 1255 403 1219 407

1325 1291 1259 375 1223 385 1191 393

1215 1182 1143 311 1107 319 1071 329

817 767 710 147 657 154 608 159

892 842 797 169 746 176 693 184

1037 992 952 222 910 230 863 239

1114 1074 1034 255 993 264 951 272

1409 1377 1347 427 1314 436 1283 446

878 796 706 138 619 144 542 150

1700 1663 1626 472 1583 487 1538 499

1512 1468 1425 359 1370 369 1325 385

1447 1403 1354 326 1301 337 1247 347

1180 1122 1058 217 991 226 917 234

1329 1283 1227 276 1169 285 1108 295

1741 1703 1664 496 1628 515 1585 528

1846 1807 1771 566 1735 585 1694 600

1885 1843 1804 590 1769 611 1731 629

890 811 727 149 647 157 579 163

1722 1679 1637 486 1595 502 1555 517

1803 1763 1723 541 1685 556 1641 569

1637 1596 1554 437 1510 452 1469 465

1087 1016 950 198 880 208 805 217

1323 1272 1222 283 1168 295 1108 306

1491 1445 1404 358 1358 370 1309 382

1889 1851 1816 601 1780 620 1743 638

1986 1947 1912 692 1873 709 1837 726

0.8 CFM Watts 362 120 863 277 652 193 608 183 933 306 1001 349 1099 400 1143 432 1193 473 354 121 937 299 871 276 818 252 542 164 614 184 1012 336 1078 373 1193 434 279 108 1186 417 1157 403 1032 337 563 166 649 190 822 247 911 281 1247 456 485 157 1489 510 1271 395 1190 357 840 242 1043 304 1537 540 1650 613 1691 643 511 170 1511 531 1604 588 1420 477 738 225 1045 318 1255 395 1702 655 1797 744

8

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32

GR9S96 Cooling & Circulation Airflow (Contd.)

MODEL

THERMOSTAT CALL

TAP #

F01 F02 F03 F04^ GR9S961005C* Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ GR9S961205D* Y/Y1, Y2, G F05 F06 F07 F08 F09

0.1 CFM 1008 2026 1921 1804 1475 1626 1693 1775 2161 1118 2143 2025 1906 1220 1684 1766 1863 2454

0.2 CFM 934 1981 1879 1755 1421 1578 1639 1723 2122 1035 2095 1977 1877 1145 1620 1712 1807 2396

EXTERNAL STATIC PRESSURE (INCHES WATER COLUMN)

0.3 0.4

0.5

0.6

0.7

CFM CFM CFM Watts CFM Watts CFM Watts

855 779 702 142 628 148 557 155

1929 1901 1858 659 1819 677 1773 685

1840 1791 1751 577 1705 588 1656 604

1710 1664 1619 490 1574 502 1526 514

1369 1314 1260 307 1207 317 1152 326

1522 1475 1427 381 1353 390 1328 401

1588 1542 1491 422 1437 432 1390 442

1674 1629 1580 472 1529 485 1484 497

2084 2048 2010 739 1973 755 1940 776

952 860 750 149 663 156 590 165

2047 2002 1954 619 1891 632 1850 647

1930 1897 1848 539 1798 553 1750 567

1828 1778 1726 474 1674 487 1622 501

1070 995 907 177 811 187 725 194

1561 1499 1438 345 1378 358 1318 371

1666 1612 1558 387 1506 401 1450 412

1754 1698 1642 432 1587 445 1532 459

2347 2296 2250 889 2202 905 2157 922

0.8 CFM Watts 493 161 1733 701 1610 617 1479 524 1097 337 1283 412 1340 453 1435 508 1914 796 519 171 1802 663 1703 583 1568 515 651 201 1259 383 1395 425 1476 472 2113 941

Notes · ^ DEFAULT SPEED

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

9

GD9S96 Heating Airflow Data

CFM & Temperature Rise vs. External Static Pressure

Model

THERMOSTAT CALL

TAP #

0.1 CFM Rise

F01^^ 632 N/A

GD9S96 0403B*

W/W1

F02^ 727 48 F03 878 41

F04 948 38

F01^^ 771 N/A

GD9S96 0603B*

W/W1

F02^ 1197 45 F03 1309 41

F04 1138 47

F01^^ 873 N/A

GD9S96 0804C*

W/W1

F02^ 1442 49 F03 1643 43

F04 1600 44

F01^^ 1176 N/A

GD9S96 1005C*

W/W1

F02^ 1773 50 F03^^ 1709 52

F04 1651 54

F01^^ 1187 N/A

GD9S96 1205D*

W/W1

F02^ 1973 54 F03 1918 56

F04 1835 58

Notes · ^ DEFAULT SPEED · ^^NOT RECOMMENDED FOR HEATING

External Static Pressure, (Inches Water Column)

0.2

0.3

0.4

0.5

CFM Rise CFM Rise CFM Rise CFM Rise

574 N/A 510 N/A 448 N/A 388 N/A

677 51 623 54 565 60 510 65

839 42 797 45 751 47 701 51

910 39 870 41 828 43 785 45

698 N/A 632 N/A 560 N/A 491 N/A

1150 46 1102 48 1057 50 1014 53

1264 42 1224 44 1180 45 1141 47

1091 49 1043 51 993 54 949 56

778 N/A 682 N/A 630 N/A 578 N/A

1386 51 1335 53 1280 56 1221 58

1588 45 1534 46 1478 48 1415 50

1555 46 1505 47 1460 49 1412 50

1107 N/A 1037 N/A 969 N/A 891 N/A

1721 52 1671 53 1621 55 1571 57

1658 54 1607 55 1556 57 1503 59

1597 56 1542 58 1491 60 1437 62

1101 N/A 1013 N/A 931 N/A 847 N/A

1916 56 1864 57 1810 59 1756 61

1859 57 1807 59 1748 61 1696 63

1776 60 1720 62 1657 64 1602 67

0.6 CFM 332 455 653 739 428 968 1098 901 490 1157 1357 1364 825 1521 1451 1384 764 1702 1643 1544

0.7 CFM 277 403 607 693 372 926 1058 853 419 1110 1299 1309 753 1470 1399 1332 677 1650 1591 1483

0.8 CFM 234 351 561 652 307 877 1018 805 347 1054 1246 1260 692 1421 1349 1278 604 1590 1531 1428

10

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32

GD9S96 Cooling & Circulation Airflow

THERMOSTAT

MODEL

TAP #

CALL

F01

F02

F03

F04^

GD9S96 0403B*

Y/Y1, Y2, G

F05

F06

F07

F08

F09

F01

F02

F03

F04^

GD9S96 0603B*

Y/Y1, Y2, G

F05

F06

F07

F08

F09

F01

F02

F03

F04^

GD9S96 0804C*

Y/Y1, Y2, G

F05

F06

F07

F08

F09

F01

F02

F03

F04^

GD9S96 1005C*

Y/Y1, Y2, G

F05

F06

F07

F08

F09

F01

F02

F03

F04^

GD9S96 1205D*

Y/Y1, Y2, G

F05

F06

F07

F08

F09

0.1 CFM 632 727 878 948 1106 1156 1237 1334 1382 771 1197 1309 1138 944 963 1332 1366 1468 873 1442 1643 1600 1338 1796 1874 1798 1991 1176 1773 1709 1651 1467 1834 1924 2028 2193 1187 1973 1918 1835 1236 1521 1673 2033 2257

Notes · ^ DEFAULT SPEED

0.2 CFM 574 677 839 910 1076 1125 1205 1306 1354 698 1150 1264 1091 884 907 1289 1319 1436 778 1386 1588 1555 1269 1744 1823 1754 1947 1107 1721 1658 1597 1409 1785 1881 1994 2145 1101 1916 1859 1776 1152 1459 1609 1981 2201

EXTERNAL STATIC PRESSURE (INCHES WATER COLUMN)

0.3 0.4

0.5

0.6

0.7

CFM CFM CFM Watts CFM Watts CFM Watts

510 448 388 80 332 85 277 89

623 565 510 101 455 106 403 111

797 751 701 146 653 151 607 157

870 828 785 169 739 175 693 181

1044 1010 974 243 939 250 899 256

1096 1063 1028 268 996 276 960 282

1174 1145 1115 317 1081 324 1050 332

1275 1249 1220 385 1194 391 1163 398

1327 1302 1276 418 1246 424 1219 432

632 560 491 104 428 110 372 115

1102 1057 1014 254 968 262 926 272

1224 1180 1141 318 1098 325 1058 334

1043 993 949 227 901 235 853 243

824 774 716 151 660 158 605 163

852 803 745 160 689 166 639 173

1245 1200 1160 327 1120 335 1081 343

1277 1235 1192 347 1154 354 1117 363

1393 1359 1323 418 1285 427 1248 436

682 630 578 90 490 94 419 100

1335 1280 1221 288 1157 297 1110 307

1534 1478 1415 339 1357 350 1299 361

1505 1460 1412 375 1364 384 1309 395

1206 1133 1063 211 999 220 934 229

1691 1638 1584 430 1532 441 1473 453

1775 1729 1675 482 1621 492 1567 500

1719 1672 1627 500 1585 510 1546 520

1900 1854 1808 573 1759 585 1707 592

1037 969 891 184 825 194 753 201

1671 1621 1571 465 1521 474 1470 485

1607 1556 1503 426 1451 436 1399 445

1542 1491 1437 392 1384 401 1332 410

1352 1307 1240 297 1182 306 1124 315

1738 1691 1643 513 1593 522 1545 532

1836 1796 1750 583 1701 592 1652 602

1937 1899 1863 683 1814 690 1769 702

2106 2076 2032 844 1998 852 1945 862

1013 931 847 165 764 174 677 180

1864 1810 1756 502 1702 513 1650 525

1807 1748 1696 463 1643 476 1591 486

1720 1657 1602 414 1544 425 1483 436

1073 990 919 181 834 190 749 198

1391 1327 1253 271 1187 281 1116 291

1549 1493 1430 345 1362 354 1305 365

1929 1878 1822 541 1771 553 1716 565

2151 2099 2057 704 2008 719 1959 732

0.8 CFM Watts 234 93 351 116 561 162 652 187 860 263 927 290 1016 341 1136 408 1190 439 307 119 877 279 1018 343 805 249 554 169 587 179 1036 353 1074 371 1210 445 347 105 1054 316 1246 375 1260 403 861 239 1422 462 1512 517 1497 530 1655 606 692 207 1421 495 1349 455 1278 421 1063 325 1502 543 1606 614 1724 713 1903 874 604 186 1590 536 1531 497 1428 447 679 204 1053 302 1242 375 1669 578 1906 742

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

11

Temperature Rise Range Chart

12

BTUBTOUUOTuPtUpTuvtsVTs.ETMePmEpRerAaTtUuRrEe RRiIsSeECChaHrAtRT
100

TETMePmEpeRrAaTtUurReERiRsIeSE

600 CFM
90
700

80

800

900

70

1000

1100

1200
60

1400

50

1600

1800

2000

40

2200

2400 CFM

www. goodmanmfg.com

30
FFOoRrMmUulLaAsS

BTUBTOUU/hTOPuUtpTut==CCFFMMxx1.10.80x8RxiseRISE

20

RISREise==

BBTTUU/OHUOTutPpUutT C1F.M08x 1.08

÷

CFM

10

30

40

50

60

70

80

90

100

110

120

130

140 150

OOUuTtPpUuTt BTTUU//HhRx 1x,10000

SS-GR9S96_GD9S96-R32

6.00±.10 LABEL
5.50±.10 FRAME

.25

Wiring Diagram

.25

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power 
sources may be present. Failure to do so may cause property damage, personal injury, or death.

10.75±.10 LABEL
10.25±.10 FRAME

HOT SURFACE IGNITER
C

21

GAS

2 CIRCUIT

VALVE HI

CONNECTOR

RD

WH

GY BR

C NO
FRONT COVER PRESSURE SWITCH

GY

ID BLOWER C PRESSURE SWITCH

SOME UNITS MAY HAVE 1 ROLL OUT SWITCH

PU

PK

YL PU

AUTO RESET PRIMARY

LIMIT CONTROL

RD

WH

RD

BK

INDUCED DRAFT
BLOWER

BURNER COMPARTMENT

GND

BLOWER COMPARTMENT

RD

AUTO RESET AUXILIARY

PU

LIMIT

YL

PK

CONTROL

WH

WH

BK WH WH

WH

BK BK

GR GND

JUNCTION BOX

NO YL

GND

TO 115 VAC/ 1 /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE
L

BK WH

FLAME SENSOR

NOTES:

DISCONNECT

WARNING: DISCONNECT POWER BEFORE N SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED

1. MANUFACTURER'S SPECIFIED REPLACEMENT

PARTS MUST BE USED WHEN SERVICING.

2. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED

WITH THE FURNACE MUST BE REPLACED IT MUST

BE REPLACED WITH WIRING MATERIAL

HAVING A TEMPERATURE RATING OF AT LEAST

105° C. USE COPPER CONDUCTORS ONLY.

3. UNIT MUST BE PERMANENTLY GROUNDED AND

CONFORM TO N.E.C. AND LOCAL CODES.

YL

4. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE

THAN 2 SECONDS WHILE IN STANDBY

(NO THERMOSTAT INPUTS)

5. WHEN THIS FURNACE IS PAIRED WITH NON R-32

REFRIGERANT SYSTEMS, DEFAULT SETTINGS

WILL NEED TO BE CHANGED. REFER TO

INSTALLATION MANUAL FOR FURTHER

INSTRUCTIONS.

WIRE COLOR:
WHITE BLACK YELLOW BLUE
RED ORANGE BROWN TAN PINK GRAY GREEN PURPLE VIOLET

COLOR DESIGNATION:
WH BK YL BL
RD OR BR TN PK GY GR
PU VT

E1 E2 E20 SPARE A2L VT- VTALARM OUT IN

EAC-H XFMR-H LINE-H
NEUT2
E15
NEUT1 E8 CIRC-N E7 EAC-N E6 HUM-N
E5
XFMR-N E4 LINE-N
E3 E39
CIRC-H

RD BK

1

2

RD

3 SW1 1

6

3

R223 SW2

1

R226 3 SW3

BK

BL RD OR
YL

T1
T2 T3 T4 T5
COM

YL

PK YL

BR GY

LEFT CENTER RIGHT

12 9 6 3 11 8 5 2 10 7 4 1

GND

RD

A2L SENSOR CONNECTOR

1

2

5V

A2L MODE IS ENABLED BY

DEFAULT REFER TO INSTALLATION MANUAL

FOR FURTHER INSTRUCTIONS.

PU GY
RD
BL
E21 E24

TWIN 24V HUM

W/W1 R G C Y/Y1 Y2

24 115 VAC VAC

45 12 3

ECM MOTOR HARNESS

N WH
G

L

BK

C RD

GR

GND

CIRCULATOR BLOWER

GR 40 VA
TRANSFORMER WH
WH GND

BK
BK BK
BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN)

EQUIPMENT GROUND
FIELD GROUND FIELD SPLICE SWITCH (TEMPERATURE) IGNITER SWITCH (PRESSURE) OVERCURRENT PROTECTION DEVICE LOW VOLTAGE (24V) LOW VOLTAGE FIELD HIGH VOLTAGE (115V) HIGH VOLTAGE FIELD PLUG CONNECTION TERMINAL JUNCTION

YL BK OR
RD BL

ERROR CODE STATUS READ CODES FROM LEFT TO RIGHT

SEVEN SEGMENT DISPLAY Seg#3 Seg#2 Seg#1

INTERNAL FAULTS OR IRQ LOSS

E

E

E

LOCKOUT DUE TO EXCESSIVE RETRIES RECYCLE

E

E

0

PRESSURE SWITCH STUCK CLOSED

E

E

1

PRESSURE SWITCH OPEN

E

E

2

OPEN HIGH LIMIT SWITCH

E

E

3

FLAME DETECTED WHEN NO FLAME SHOULD BE PRESENT

E

E

4

OPEN FUSE

E

E

5

LOW FLAME SIGNAL

E

E

6

IGNITOR RELAY FAULT

E

E

L

REVERSED LINE POLARITY OR GROUNDING ERROR

E

E

A

INTERNAL GAS VALVE ERROR

E

E

b

EXTERNAL GAS VALVE ERROR

E

E

C

OPEN ROLLOUT SWITCH

E

1

1

IGNITOR OPEN

E

E

n

INDUCER RELAY ERROR

E

E

J

ERROR CODE STATUS READ CODES FROM LEFT TO RIGHT
TWIN ERROR GROUNDING ERROR LOW CIRCULATOR CURRENT CIRCULATOR CURRENT UNEXPECTED A2L COMMUNICATION ALARM A2L LEAKAGE ALARM A2L INTERNAL ALARM A2L RELAY ALARM

SEVEN SEGMENT DISPLAY

Seg#3 Seg#2 Seg#1

E

E

H

E

1

0

E

b

L

E

b

U

E

A

F

E

A

L

E

A

S

E

A

r

0140F20003-B

 Warning

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

2331087

B

1. REDRAWN IN CREO

2. REMOVED SHEET 2

3. REMOVED LADDER DIAGRAM AND LABEL UPDATED FOR MARKUP

CHANGES. (ALL)

4. ADDED NOTE 5 (D7)

DAIKIN COMFORT TECHNOLOGIES

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

13

Accessories

Model

Description

72950 72951 RF000142 EFR02 0170K00000S 0170K00001S AFE18-60A HASFK HASFK 0270F20723 LPM-33

Concentric Vent Kit (2") Concentric Vent Kit (3") Drain Kit Horizontal Left Vertical Flue External Filter Rack with 16"x25" Permanent Filter Flush Mount Vent Kit - 3" or 2" Flush Mount Vent Kit - 2" Fossil Fuel (Dual Fuel) Kit High-Altitude Natural Gas Kit High-Altitude LP Gas Kit Horizontal Drain Tubing Kit LP Conversion Kits

GR9S96 0403ANA
       TBD TBD  

GR9S96 GR9S96 GR9S96 GR9S96 GR9S96 GR9S96 0603BNA 0803BNA 0804CNA 0805CNA 1005CNA 1205DNA

















































   HASFK-4 HASFK-6  

   HASFK-4 HASFK-6  

   HASFK-4 HASFK-6  

   HASFK-4 HASFK-5  

   HASFK-4 HASFK-5  

   HASFK-4 HASFK-5  

Model

Description

72950 72951 CFSB17 CFSB21 CFSB24 RF000142 EFR02 0170K00000S 0170K00001S AFE18-60A HASFK HASFK 0270F05405 LPM-33

Concentric Vent Kit (2") Concentric Vent Kit (3") Downflow Sub-Base 17.5" Downflow Sub-Base 21" Downflow Sub-Base 24" Drain Kit Horizontal Left Vertical Flue External Filter Rack with 16"x25" Permanent Filter Flush Mount Vent Kit - 3" or 2" Flush Mount Vent Kit - 2" Fossil Fuel (Dual Fuel) Kit High-Altitude Natural Gas Kit High-Altitude LP Gas Kit Horizontal Drain Tubing Kit LP Conversion Kits

GD9S96 0403BNA
          HASFK-4 HASFK-5  

GD9S96 GD9S96 GD9S96 GD9S96 0603BNA 0804CNA 1005CNA 1205DNA

















































    HASFK-4 HASFK-5  

    HASFK-4 HASFK-5  

    HASFK-4 HASFK-4  

    HASFK-4 HASFK-4  

14

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32

Notes

SS-GR9S96_GD9S96-R32

www.goodmanmfg.com

15

Notes

Our continuing commitment to quality products may mean a change in specifications without notice.

©2024

· Houston, Texas · Printed in the USA.

16

www. goodmanmfg.com

SS-GR9S96_GD9S96-R32


Adobe InDesign 19.4 (Macintosh) Adobe PDF Library 17.0