ss-gr9s96 gd9s96-r32
Heating Input: 40,000120,000 BTU/h GR9S96 / GD9S96 Single-Stage, Multi-Speed ECM Gas Furnace Up to 97% AFUE Contents Nomenclature............................................. 2 Product Specifications................................ 3 Dimensions................................................. 5 Airflow Specifications.................................7 Wiring Diagram.. .......................................13 Accessories...............................................14 Standard Features · Heavy-duty aluminized-steel tubular heat exchanger · Stainless-steel secondary heat exchanger · Single-stage gas valve · Durable Silicon Nitride igniter · Quiet single-speed induced draft blower · Self-diagnostic control board with constant memory fault code history output to a LED · All models comply with California 40 ng/J Low NOx emissions standard · Can not be installed in California's South Coast AirQuality Management District (SCAQMD) and San Joaquin Valley Air Pollution Control District (SJVAPCD). · AHRI Certified; ETL Listed Cabinet Features · Designed for multi-position installation -- GR9S96: upflow, horizontal left or right GD9S96: downflow, horizontal left or right · Certified for direct vent (2-pipe) or non-direct vent (1-pipe) · Easy-to-install top venting with optional side venting · Convenient left or right connection for gas and electrical service · Cabinet air leakage (QLeak) 2% · Heavy-gauge steel cabinet with durable finish · Fully insulated heat exchanger and blower section · Airtight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications SS-GR9S96_GD9S96-R32 * Complete warranty details available from your local dealer or at www.amana-hac.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. www.goodmanmfg.com 08/24 Supersedes 05/24 Nomenclature G R 9 S 96 040 4 C * ** 1 2 3 4 5,6 7,8,9 10 11 12 13,14 Brand G - Goodman® Brand Configuration R - Upflow/Horizontal D - Downflow/Horizontal Engineering Major/Minor Revisions A - Initial Release B - 1st Revision NOx N = < 40 NG/J NOx Motor 9 - Nine Speed ECM Gas Valve T - 2 Stage S - 1 Stage Cabinet Width A - 14" C - 21" B - 17½" D - 24½" 3 - 1200 CFM Maximum CFM 4 - 1600 CFM 5 - 2000 CFM AFUE 80 - 80% AFUE 92 - 92% AFUE 96 - 96% AFUE*** 97 - 97% AFUE *** Some models are rated up to 97% AFUE 030 - 30,000 BTU/h 040 - 40,000 BTU/h 060 - 60,000 BTU/h MBTU/h 080 - 80,000 BTU/h 100 - 100,000 BTU/h 120 - 120,000 BTU/h 2 www. goodmanmfg.com SS-GR9S96_GD9S96-R32 GR9S96 Product Specifications Heating Data High Fire Input¹ High Fire Output¹ AFUE² Temperature Rise Range (°F) Vent Diameter³ No. of Burners Circulator Blower Available AC @ 0.5" ESP Size (D x W) Horsepower @ 1075 RPM Speed Filter Size (in²) (Qty) Electrical Data Min. Circuit Ampacity Max. Overcurrent Device (amps) Shipping Weight (lbs) GR9S96 0403AN GR9S96 0603BN GR9S96 0803BN GR9S96 0804CN GR9S96 0805CN GR9S96 1005CN GR9S96 1205DN 40,000 38,800 97 25-55 2" - 3" 2 60,000 58,200 97 30-60 2" - 3" 3 80,000 76,880 96 35-65 2" - 3" 4 80,000 77,600 97 25-55 2" - 3" 4 80,000 77,600 97 25-55 2" - 3" 4 100,000 96,100 96 30-60 2" - 3" 5 120,000 115,320 96 35-65 3" 6 1.5 - 3 11" x 6" 1/2 9 (1) 16 X 25 (side) or (1) 14 X 25 (bottom) 1.5 - 3 11" x 8" 1/2 9 (1) 16 X 25 (side or bottom) 1.5 - 3 11" x 8" 1/2 9 (1) 16 X 25 (side or bottom) 1.5 - 4 11" x 10" 3/4 9 (1) 16 X 25 (side or bottom) 3 - 5 11" x 10" 1 9 (1) 20 x 25 (bottom) or (2) 16 x 25 (side) 3 - 5 11" x 10" 1 9 (1) 20 x 25 (bottom) or (2) 16 x 25 (side) 3 - 5 11" x 11" 1 9 (1) 20 x 25 (bottom) or (2) 16 x 25 (side) 9.7 10.1 10.1 13.7 16.7 16.7 16.7 15 15 15 20 25 25 25 108 118 118 141 142 144 156 ENERGY STAR® Certified ¹ Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4% for each 1000' above 4500' altitude ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes · All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. · Gas Service Connection ½" FPT · Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. · For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. · For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 3 GD9S96 Specifications Heating Data High Fire Input¹ High Fire Output¹ AFUE² Temperature Rise Range (°F) Vent Diameter³ No. of Burners Circulator Blower Available AC @ 0.5" ESP Size (D x W) Horsepower @ 1075 RPM Speed Filter Size (in²) (Qty) Electrical Data Min. Circuit Ampacity Max. Overcurrent Device (amps) Shipping Weight (lbs) GD9S96 0403BN 40,000 38,440 96 25-55 2" - 3" 2 1.5 - 3 11" x 8" 1/2 9 (2) 10 x 20 or (1) 16 x 25 (top return) 10.1 15 113 GD9S96 0603BN 60,000 57,660 96 35-65 2" - 3" 3 1.5 - 3 11" x 8" 1/2 9 (2) 10 x 20 or (1) 16 x 25 (top return) 10.1 15 116 GD9S96 0804CN GD9S96 1005CN GD9S96 1205DN 80,000 76,880 96 40-70 2" - 3" 4 100,000 95,000 95 40-70 2" - 3" 5 120,000 115,320 96 45-75 3" 6 2.5 - 4 11" x 10" 3/4 9 (2) 10 x 20 or (1) 16 x 25 (top return) 3 - 5 3 - 5 11" x 10" 11" x 11" 1 1 9 9 (1) 14 x 20 (bottom) or (1) 20 x 25 (top return) (1) 14 x 20 (bottom) or (1) 20 x 25 (top return) 13.7 16.7 16.7 20 25 25 141 144 156 ENERGY STAR® Certified ¹ Natural Gas BTU/h; for altitudes 0-4500' above sea level, reduce input rating by 4% for each 1000' above 4500' altitude ² DOE AFUE based upon Isolated Combustion System (ICS) ³ Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC. Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes · All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. · Gas Service Connection ½" FPT · Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. · For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues. · For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Energy Star Notes Proper sizing and installation of equipment is critical to achieving optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The www.energystar.gov website provides up-to-date system combinations certified to meet ENERGY STAR requirements. 4 www. goodmanmfg.com SS-GR9S96_GD9S96-R32 GR9S96 Dimensions Air Discharge 28¾ Air Intake 2" Pipe Left-Side Drain Trap Exterior Holes 14 1½ LEFT SIDE VIEW Low-voltage Electrical Outlet 1 23 Air Discharge 6½ 2¾ 2 2 Center Dimple For Alternate Air Intake Pipe 3" OD Hole High-Voltage Electrical Outlet Standard Gas Supply Location 34½ 31 24 23 19 9¼ 5 1 2 2½ Condensate Drain Trap Exterior Connection (Right or Left Side) ¾ PVC A B ¾ C 1 6½ 2 ¾ 19½ Vent/ Flue Pipe 2" PVC ¾ Alternate Vent/ Flue Location Right-Side Drain Trap Exterior Holes High-Voltage Electrical Outlet Alternate Gas Supply FRONT VIEW D Unfolded Flanges E Folded Flanges 26½ 23 21 19 9¼ 5 Low-Voltage Electrical Outlet 1 RIGHT SIDE VIEW 2 2½ 22 Unfolded Flanges 23½ Folded Flanges Model GR9S960403AN GR9S960603BN GR9S960803BN GR9S960804CN GR9S960805CN GR9S961005CN GR9S961205DN AIR DISCHARGE A B C 14" 12½" 10½" 17½ 16" 13" 17½ 16" 13" 21" 19½" 17 21" 19½" 17 21" 19½" 17 24½ 23" 20" D 8" 12" 12" 16" 16" 16" 19" AIR DISCHARGE E 10" 13" 13" 17½" 17½" 17½" 20" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0" 0" 1" C 0" 1" Horizontal 6" 0" ALCOVE C 0" 4" C = If placed on combustible floor, the floor MUST be wood ONLY. SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 5 GD9S96 Dimensions 1 23 1½ 14 Drain Trap Holes Standard Drain Trap 28¾ Air Discharge 2 1 Low-Voltage Electrical Outlet Alternate Gas High-Voltage Electrical Outlet 34½ 25 14¾ 11 6 4 2 2½ 3½ A 6½ B C 1 2½ 1 Low-Voltage Electrical Outlet Alternate Gas Supply 25 D Unfolded Flanges E Folded Flanges Front View 14 14¾ 11 6 High-Voltage Electrical Outlet 2 2 Right Side Exterior Drain Trap Holes 18¼ Alternate Vent/ 18 Unfolded Flanges 20 Folded Flanges Right-Side View Air Discharge Model GD9S960403BN GD9S960603BNA GD9S960804CN GD9S961005CN GD9S961205DN AIR DISCHARGE A B C 17½ 16" 13" 17½ 16" 13" 21" 19½" 17 21" 19½" 17 24½ 23" 20" D 12" 12" 16" 16" 19" AIR DISCHARGE E 13" 13" 17½" 17½" 20" Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" 1" NC 0" 1" Horizontal 6" 0" ALCOVE C 0" 4" C = If placed on combustible floor, the floor MUST be wood ONLY. NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. 6 www. goodmanmfg.com SS-GR9S96_GD9S96-R32 GR9S96 Heating Airflow Data CFM & Temperature Rise vs. External Static Pressure Model GR9S96 0403A* GR9S96 0603B* GR9S96 0803B* GR9S96 0804C* GR9S96 0805C* GR9S96 1005C* GR9S96 1205D* THERMOSTAT CALL TAP # W/W1 W/W1 W/W1 W/W1 W/W1 W/W1 W/W1 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04 F01^^ F02^ F03 F04^^ 0.1 CFM Rise 705 50 1079 33 915 39 887 40 758 N/A 1218 44 1164 46 1121 48 715 N/A 1415 50 1388 51 1290 55 1019 N/A 1791 40 1625 44 1537 46 1029 N/A 1814 39 1893 38 1738 41 1008 N/A 2026 44 1921 46 1804 49 1118 N/A 2143 50 2025 53 1906 56 External Static Pressure, (Inches Water Column) 0.2 0.3 0.4 0.5 CFM Rise CFM Rise CFM Rise CFM Rise 661 54 617 N/A 564 N/A 509 N/A 1055 34 1027 35 994 36 965 37 881 40 846 42 814 44 780 46 855 42 823 43 790 45 751 47 696 N/A 636 N/A 572 N/A 512 N/A 1178 45 1140 47 1100 48 1060 50 1123 47 1084 49 1042 51 1003 53 1083 49 1041 51 996 54 953 56 658 N/A 589 N/A 524 N/A 465 N/A 1385 51 1355 52 1322 54 1291 55 1360 52 1325 54 1291 55 1259 57 1252 57 1215 59 1182 60 1143 62 952 N/A 878 N/A 796 N/A 706 N/A 1743 41 1700 42 1663 43 1626 44 1559 46 1512 47 1468 48 1425 50 1490 48 1447 49 1403 51 1354 53 959 N/A 890 N/A 811 N/A 727 N/A 1766 40 1722 41 1679 42 1637 43 1844 39 1803 39 1763 40 1723 41 1680 42 1637 43 1596 45 1554 46 934 N/A 855 N/A 779 N/A 702 N/A 1981 45 1929 46 1901 47 1858 48 1879 47 1840 48 1791 50 1751 51 1755 51 1710 52 1664 53 1619 55 1035 N/A 952 N/A 860 N/A 750 N/A 2095 51 2047 52 2002 53 1954 55 1977 54 1930 55 1897 56 1848 58 1877 57 1828 58 1778 60 1726 62 0.6 0.7 0.8 CFM CFM CFM 455 405 362 935 906 863 737 695 652 705 666 608 460 412 354 1016 977 937 960 920 871 906 861 818 412 360 279 1255 1219 1186 1223 1191 1157 1107 1071 1032 619 542 485 1583 1538 1489 1370 1325 1271 1301 1247 1190 647 579 511 1595 1555 1511 1685 1641 1604 1510 1469 1420 628 557 493 1819 1773 1733 1705 1656 1610 1574 1526 1479 663 590 519 1891 1850 1802 1798 1750 1703 1674 1622 1568 SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 7 GR9S96 Cooling & Circulation Airflow MODEL GR9S96 0403A* GR9S96 0603B* GR9S96 0803B* GR9S96 0804C* GR9S96 0805C* THERMOSTAT CALL TAP # F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ Y/Y1, Y2, G F05 F06 F07 F08 F09 0.1 CFM 705 1079 915 887 1135 1189 1266 1313 1342 758 1218 1164 1121 902 960 1273 1335 1427 715 1415 1388 1290 916 985 1118 1191 1471 1019 1791 1625 1537 1289 1431 1836 1919 1952 1029 1814 1893 1738 1193 1421 1582 1962 2068 0.2 CFM 661 1055 881 855 1106 1163 1243 1288 1324 696 1178 1123 1083 851 917 1240 1301 1390 658 1385 1360 1252 867 940 1078 1153 1440 952 1743 1559 1490 1234 1375 1784 1890 1921 959 1766 1844 1680 1135 1369 1536 1919 2024 EXTERNAL STATIC PRESSURE (INCHES WATER COLUMN) 0.3 0.4 0.5 0.6 0.7 CFM CFM CFM Watts CFM Watts CFM Watts 617 564 509 103 455 108 405 115 1027 994 965 256 935 264 906 271 846 814 780 174 737 180 695 186 823 790 751 164 705 170 666 176 1078 1049 1021 281 994 290 965 299 1138 1111 1085 321 1059 331 1032 341 1218 1197 1172 372 1148 383 1123 394 1261 1239 1215 403 1189 412 1165 422 1305 1280 1263 440 1239 452 1216 463 636 572 512 104 460 110 412 115 1140 1100 1060 275 1016 284 977 292 1084 1042 1003 249 960 258 920 268 1041 996 953 230 906 236 861 245 801 746 689 145 637 153 585 158 864 812 764 164 708 171 661 179 1207 1171 1128 309 1089 318 1051 327 1266 1228 1192 347 1154 356 1118 365 1362 1327 1297 408 1260 414 1224 423 589 524 465 93 412 99 360 104 1355 1322 1291 394 1255 403 1219 407 1325 1291 1259 375 1223 385 1191 393 1215 1182 1143 311 1107 319 1071 329 817 767 710 147 657 154 608 159 892 842 797 169 746 176 693 184 1037 992 952 222 910 230 863 239 1114 1074 1034 255 993 264 951 272 1409 1377 1347 427 1314 436 1283 446 878 796 706 138 619 144 542 150 1700 1663 1626 472 1583 487 1538 499 1512 1468 1425 359 1370 369 1325 385 1447 1403 1354 326 1301 337 1247 347 1180 1122 1058 217 991 226 917 234 1329 1283 1227 276 1169 285 1108 295 1741 1703 1664 496 1628 515 1585 528 1846 1807 1771 566 1735 585 1694 600 1885 1843 1804 590 1769 611 1731 629 890 811 727 149 647 157 579 163 1722 1679 1637 486 1595 502 1555 517 1803 1763 1723 541 1685 556 1641 569 1637 1596 1554 437 1510 452 1469 465 1087 1016 950 198 880 208 805 217 1323 1272 1222 283 1168 295 1108 306 1491 1445 1404 358 1358 370 1309 382 1889 1851 1816 601 1780 620 1743 638 1986 1947 1912 692 1873 709 1837 726 0.8 CFM Watts 362 120 863 277 652 193 608 183 933 306 1001 349 1099 400 1143 432 1193 473 354 121 937 299 871 276 818 252 542 164 614 184 1012 336 1078 373 1193 434 279 108 1186 417 1157 403 1032 337 563 166 649 190 822 247 911 281 1247 456 485 157 1489 510 1271 395 1190 357 840 242 1043 304 1537 540 1650 613 1691 643 511 170 1511 531 1604 588 1420 477 738 225 1045 318 1255 395 1702 655 1797 744 8 www. goodmanmfg.com SS-GR9S96_GD9S96-R32 GR9S96 Cooling & Circulation Airflow (Contd.) MODEL THERMOSTAT CALL TAP # F01 F02 F03 F04^ GR9S961005C* Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ GR9S961205D* Y/Y1, Y2, G F05 F06 F07 F08 F09 0.1 CFM 1008 2026 1921 1804 1475 1626 1693 1775 2161 1118 2143 2025 1906 1220 1684 1766 1863 2454 0.2 CFM 934 1981 1879 1755 1421 1578 1639 1723 2122 1035 2095 1977 1877 1145 1620 1712 1807 2396 EXTERNAL STATIC PRESSURE (INCHES WATER COLUMN) 0.3 0.4 0.5 0.6 0.7 CFM CFM CFM Watts CFM Watts CFM Watts 855 779 702 142 628 148 557 155 1929 1901 1858 659 1819 677 1773 685 1840 1791 1751 577 1705 588 1656 604 1710 1664 1619 490 1574 502 1526 514 1369 1314 1260 307 1207 317 1152 326 1522 1475 1427 381 1353 390 1328 401 1588 1542 1491 422 1437 432 1390 442 1674 1629 1580 472 1529 485 1484 497 2084 2048 2010 739 1973 755 1940 776 952 860 750 149 663 156 590 165 2047 2002 1954 619 1891 632 1850 647 1930 1897 1848 539 1798 553 1750 567 1828 1778 1726 474 1674 487 1622 501 1070 995 907 177 811 187 725 194 1561 1499 1438 345 1378 358 1318 371 1666 1612 1558 387 1506 401 1450 412 1754 1698 1642 432 1587 445 1532 459 2347 2296 2250 889 2202 905 2157 922 0.8 CFM Watts 493 161 1733 701 1610 617 1479 524 1097 337 1283 412 1340 453 1435 508 1914 796 519 171 1802 663 1703 583 1568 515 651 201 1259 383 1395 425 1476 472 2113 941 Notes · ^ DEFAULT SPEED SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 9 GD9S96 Heating Airflow Data CFM & Temperature Rise vs. External Static Pressure Model THERMOSTAT CALL TAP # 0.1 CFM Rise F01^^ 632 N/A GD9S96 0403B* W/W1 F02^ 727 48 F03 878 41 F04 948 38 F01^^ 771 N/A GD9S96 0603B* W/W1 F02^ 1197 45 F03 1309 41 F04 1138 47 F01^^ 873 N/A GD9S96 0804C* W/W1 F02^ 1442 49 F03 1643 43 F04 1600 44 F01^^ 1176 N/A GD9S96 1005C* W/W1 F02^ 1773 50 F03^^ 1709 52 F04 1651 54 F01^^ 1187 N/A GD9S96 1205D* W/W1 F02^ 1973 54 F03 1918 56 F04 1835 58 Notes · ^ DEFAULT SPEED · ^^NOT RECOMMENDED FOR HEATING External Static Pressure, (Inches Water Column) 0.2 0.3 0.4 0.5 CFM Rise CFM Rise CFM Rise CFM Rise 574 N/A 510 N/A 448 N/A 388 N/A 677 51 623 54 565 60 510 65 839 42 797 45 751 47 701 51 910 39 870 41 828 43 785 45 698 N/A 632 N/A 560 N/A 491 N/A 1150 46 1102 48 1057 50 1014 53 1264 42 1224 44 1180 45 1141 47 1091 49 1043 51 993 54 949 56 778 N/A 682 N/A 630 N/A 578 N/A 1386 51 1335 53 1280 56 1221 58 1588 45 1534 46 1478 48 1415 50 1555 46 1505 47 1460 49 1412 50 1107 N/A 1037 N/A 969 N/A 891 N/A 1721 52 1671 53 1621 55 1571 57 1658 54 1607 55 1556 57 1503 59 1597 56 1542 58 1491 60 1437 62 1101 N/A 1013 N/A 931 N/A 847 N/A 1916 56 1864 57 1810 59 1756 61 1859 57 1807 59 1748 61 1696 63 1776 60 1720 62 1657 64 1602 67 0.6 CFM 332 455 653 739 428 968 1098 901 490 1157 1357 1364 825 1521 1451 1384 764 1702 1643 1544 0.7 CFM 277 403 607 693 372 926 1058 853 419 1110 1299 1309 753 1470 1399 1332 677 1650 1591 1483 0.8 CFM 234 351 561 652 307 877 1018 805 347 1054 1246 1260 692 1421 1349 1278 604 1590 1531 1428 10 www. goodmanmfg.com SS-GR9S96_GD9S96-R32 GD9S96 Cooling & Circulation Airflow THERMOSTAT MODEL TAP # CALL F01 F02 F03 F04^ GD9S96 0403B* Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ GD9S96 0603B* Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ GD9S96 0804C* Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ GD9S96 1005C* Y/Y1, Y2, G F05 F06 F07 F08 F09 F01 F02 F03 F04^ GD9S96 1205D* Y/Y1, Y2, G F05 F06 F07 F08 F09 0.1 CFM 632 727 878 948 1106 1156 1237 1334 1382 771 1197 1309 1138 944 963 1332 1366 1468 873 1442 1643 1600 1338 1796 1874 1798 1991 1176 1773 1709 1651 1467 1834 1924 2028 2193 1187 1973 1918 1835 1236 1521 1673 2033 2257 Notes · ^ DEFAULT SPEED 0.2 CFM 574 677 839 910 1076 1125 1205 1306 1354 698 1150 1264 1091 884 907 1289 1319 1436 778 1386 1588 1555 1269 1744 1823 1754 1947 1107 1721 1658 1597 1409 1785 1881 1994 2145 1101 1916 1859 1776 1152 1459 1609 1981 2201 EXTERNAL STATIC PRESSURE (INCHES WATER COLUMN) 0.3 0.4 0.5 0.6 0.7 CFM CFM CFM Watts CFM Watts CFM Watts 510 448 388 80 332 85 277 89 623 565 510 101 455 106 403 111 797 751 701 146 653 151 607 157 870 828 785 169 739 175 693 181 1044 1010 974 243 939 250 899 256 1096 1063 1028 268 996 276 960 282 1174 1145 1115 317 1081 324 1050 332 1275 1249 1220 385 1194 391 1163 398 1327 1302 1276 418 1246 424 1219 432 632 560 491 104 428 110 372 115 1102 1057 1014 254 968 262 926 272 1224 1180 1141 318 1098 325 1058 334 1043 993 949 227 901 235 853 243 824 774 716 151 660 158 605 163 852 803 745 160 689 166 639 173 1245 1200 1160 327 1120 335 1081 343 1277 1235 1192 347 1154 354 1117 363 1393 1359 1323 418 1285 427 1248 436 682 630 578 90 490 94 419 100 1335 1280 1221 288 1157 297 1110 307 1534 1478 1415 339 1357 350 1299 361 1505 1460 1412 375 1364 384 1309 395 1206 1133 1063 211 999 220 934 229 1691 1638 1584 430 1532 441 1473 453 1775 1729 1675 482 1621 492 1567 500 1719 1672 1627 500 1585 510 1546 520 1900 1854 1808 573 1759 585 1707 592 1037 969 891 184 825 194 753 201 1671 1621 1571 465 1521 474 1470 485 1607 1556 1503 426 1451 436 1399 445 1542 1491 1437 392 1384 401 1332 410 1352 1307 1240 297 1182 306 1124 315 1738 1691 1643 513 1593 522 1545 532 1836 1796 1750 583 1701 592 1652 602 1937 1899 1863 683 1814 690 1769 702 2106 2076 2032 844 1998 852 1945 862 1013 931 847 165 764 174 677 180 1864 1810 1756 502 1702 513 1650 525 1807 1748 1696 463 1643 476 1591 486 1720 1657 1602 414 1544 425 1483 436 1073 990 919 181 834 190 749 198 1391 1327 1253 271 1187 281 1116 291 1549 1493 1430 345 1362 354 1305 365 1929 1878 1822 541 1771 553 1716 565 2151 2099 2057 704 2008 719 1959 732 0.8 CFM Watts 234 93 351 116 561 162 652 187 860 263 927 290 1016 341 1136 408 1190 439 307 119 877 279 1018 343 805 249 554 169 587 179 1036 353 1074 371 1210 445 347 105 1054 316 1246 375 1260 403 861 239 1422 462 1512 517 1497 530 1655 606 692 207 1421 495 1349 455 1278 421 1063 325 1502 543 1606 614 1724 713 1903 874 604 186 1590 536 1531 497 1428 447 679 204 1053 302 1242 375 1669 578 1906 742 SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 11 Temperature Rise Range Chart 12 BTUBTOUUOTuPtUpTuvtsVTs.ETMePmEpRerAaTtUuRrEe RRiIsSeECChaHrAtRT 100 TETMePmEpeRrAaTtUurReERiRsIeSE 600 CFM 90 700 80 800 900 70 1000 1100 1200 60 1400 50 1600 1800 2000 40 2200 2400 CFM www. goodmanmfg.com 30 FFOoRrMmUulLaAsS BTUBTOUU/hTOPuUtpTut==CCFFMMxx1.10.80x8RxiseRISE 20 RISREise== BBTTUU/OHUOTutPpUutT C1F.M08x 1.08 ÷ CFM 10 30 40 50 60 70 80 90 100 110 120 130 140 150 OOUuTtPpUuTt BTTUU//HhRx 1x,10000 SS-GR9S96_GD9S96-R32 6.00±.10 LABEL 5.50±.10 FRAME .25 Wiring Diagram .25 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. 10.75±.10 LABEL 10.25±.10 FRAME HOT SURFACE IGNITER C 21 GAS 2 CIRCUIT VALVE HI CONNECTOR RD WH GY BR C NO FRONT COVER PRESSURE SWITCH GY ID BLOWER C PRESSURE SWITCH SOME UNITS MAY HAVE 1 ROLL OUT SWITCH PU PK YL PU AUTO RESET PRIMARY LIMIT CONTROL RD WH RD BK INDUCED DRAFT BLOWER BURNER COMPARTMENT GND BLOWER COMPARTMENT RD AUTO RESET AUXILIARY PU LIMIT YL PK CONTROL WH WH BK WH WH WH BK BK GR GND JUNCTION BOX NO YL GND TO 115 VAC/ 1 /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE L BK WH FLAME SENSOR NOTES: DISCONNECT WARNING: DISCONNECT POWER BEFORE N SERVICING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED 1. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 2. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105° C. USE COPPER CONDUCTORS ONLY. 3. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. YL 4. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS) 5. WHEN THIS FURNACE IS PAIRED WITH NON R-32 REFRIGERANT SYSTEMS, DEFAULT SETTINGS WILL NEED TO BE CHANGED. REFER TO INSTALLATION MANUAL FOR FURTHER INSTRUCTIONS. WIRE COLOR: WHITE BLACK YELLOW BLUE RED ORANGE BROWN TAN PINK GRAY GREEN PURPLE VIOLET COLOR DESIGNATION: WH BK YL BL RD OR BR TN PK GY GR PU VT E1 E2 E20 SPARE A2L VT- VTALARM OUT IN EAC-H XFMR-H LINE-H NEUT2 E15 NEUT1 E8 CIRC-N E7 EAC-N E6 HUM-N E5 XFMR-N E4 LINE-N E3 E39 CIRC-H RD BK 1 2 RD 3 SW1 1 6 3 R223 SW2 1 R226 3 SW3 BK BL RD OR YL T1 T2 T3 T4 T5 COM YL PK YL BR GY LEFT CENTER RIGHT 12 9 6 3 11 8 5 2 10 7 4 1 GND RD A2L SENSOR CONNECTOR 1 2 5V A2L MODE IS ENABLED BY DEFAULT REFER TO INSTALLATION MANUAL FOR FURTHER INSTRUCTIONS. PU GY RD BL E21 E24 TWIN 24V HUM W/W1 R G C Y/Y1 Y2 24 115 VAC VAC 45 12 3 ECM MOTOR HARNESS N WH G L BK C RD GR GND CIRCULATOR BLOWER GR 40 VA TRANSFORMER WH WH GND BK BK BK BLOWER COMPARTMENT DOOR SWITCH (OPEN WHEN DOOR OPEN) EQUIPMENT GROUND FIELD GROUND FIELD SPLICE SWITCH (TEMPERATURE) IGNITER SWITCH (PRESSURE) OVERCURRENT PROTECTION DEVICE LOW VOLTAGE (24V) LOW VOLTAGE FIELD HIGH VOLTAGE (115V) HIGH VOLTAGE FIELD PLUG CONNECTION TERMINAL JUNCTION YL BK OR RD BL ERROR CODE STATUS READ CODES FROM LEFT TO RIGHT SEVEN SEGMENT DISPLAY Seg#3 Seg#2 Seg#1 INTERNAL FAULTS OR IRQ LOSS E E E LOCKOUT DUE TO EXCESSIVE RETRIES RECYCLE E E 0 PRESSURE SWITCH STUCK CLOSED E E 1 PRESSURE SWITCH OPEN E E 2 OPEN HIGH LIMIT SWITCH E E 3 FLAME DETECTED WHEN NO FLAME SHOULD BE PRESENT E E 4 OPEN FUSE E E 5 LOW FLAME SIGNAL E E 6 IGNITOR RELAY FAULT E E L REVERSED LINE POLARITY OR GROUNDING ERROR E E A INTERNAL GAS VALVE ERROR E E b EXTERNAL GAS VALVE ERROR E E C OPEN ROLLOUT SWITCH E 1 1 IGNITOR OPEN E E n INDUCER RELAY ERROR E E J ERROR CODE STATUS READ CODES FROM LEFT TO RIGHT TWIN ERROR GROUNDING ERROR LOW CIRCULATOR CURRENT CIRCULATOR CURRENT UNEXPECTED A2L COMMUNICATION ALARM A2L LEAKAGE ALARM A2L INTERNAL ALARM A2L RELAY ALARM SEVEN SEGMENT DISPLAY Seg#3 Seg#2 Seg#1 E E H E 1 0 E b L E b U E A F E A L E A S E A r 0140F20003-B Warning Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 2331087 B 1. REDRAWN IN CREO 2. REMOVED SHEET 2 3. REMOVED LADDER DIAGRAM AND LABEL UPDATED FOR MARKUP CHANGES. (ALL) 4. ADDED NOTE 5 (D7) DAIKIN COMFORT TECHNOLOGIES SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 13 Accessories Model Description 72950 72951 RF000142 EFR02 0170K00000S 0170K00001S AFE18-60A HASFK HASFK 0270F20723 LPM-33 Concentric Vent Kit (2") Concentric Vent Kit (3") Drain Kit Horizontal Left Vertical Flue External Filter Rack with 16"x25" Permanent Filter Flush Mount Vent Kit - 3" or 2" Flush Mount Vent Kit - 2" Fossil Fuel (Dual Fuel) Kit High-Altitude Natural Gas Kit High-Altitude LP Gas Kit Horizontal Drain Tubing Kit LP Conversion Kits GR9S96 0403ANA TBD TBD GR9S96 GR9S96 GR9S96 GR9S96 GR9S96 GR9S96 0603BNA 0803BNA 0804CNA 0805CNA 1005CNA 1205DNA HASFK-4 HASFK-6 HASFK-4 HASFK-6 HASFK-4 HASFK-6 HASFK-4 HASFK-5 HASFK-4 HASFK-5 HASFK-4 HASFK-5 Model Description 72950 72951 CFSB17 CFSB21 CFSB24 RF000142 EFR02 0170K00000S 0170K00001S AFE18-60A HASFK HASFK 0270F05405 LPM-33 Concentric Vent Kit (2") Concentric Vent Kit (3") Downflow Sub-Base 17.5" Downflow Sub-Base 21" Downflow Sub-Base 24" Drain Kit Horizontal Left Vertical Flue External Filter Rack with 16"x25" Permanent Filter Flush Mount Vent Kit - 3" or 2" Flush Mount Vent Kit - 2" Fossil Fuel (Dual Fuel) Kit High-Altitude Natural Gas Kit High-Altitude LP Gas Kit Horizontal Drain Tubing Kit LP Conversion Kits GD9S96 0403BNA HASFK-4 HASFK-5 GD9S96 GD9S96 GD9S96 GD9S96 0603BNA 0804CNA 1005CNA 1205DNA HASFK-4 HASFK-5 HASFK-4 HASFK-5 HASFK-4 HASFK-4 HASFK-4 HASFK-4 14 www. goodmanmfg.com SS-GR9S96_GD9S96-R32 Notes SS-GR9S96_GD9S96-R32 www.goodmanmfg.com 15 Notes Our continuing commitment to quality products may mean a change in specifications without notice. ©2024 · Houston, Texas · Printed in the USA. 16 www. goodmanmfg.com SS-GR9S96_GD9S96-R32Adobe InDesign 19.4 (Macintosh) Adobe PDF Library 17.0