Goodman GRVT96 / GDVT96 Series Gas Furnaces
This document provides detailed specifications, features, dimensions, airflow data, nomenclature, and accessory information for the Goodman GRVT96 and GDVT96 series of two-stage, variable-speed ECM gas furnaces.
Key Features & Specifications
Heating Input: 40,000–120,000 BTU/H
Product Type: TWO-STAGE, VARIABLE-SPEED ECM GAS FURNACE
Efficiency: UP TO 96% AFUE
Brand: Goodman Air Conditioning & Heating
Model Series: GRVT96 / GDVT96
Standard Features
- Integrated communicating ComfortBridge™ Technology
- Commissioning and diagnostics via on-board Bluetooth with the CoolCloud phone and tablet application
- Heavy-duty aluminized-steel tubular heat exchanger
- Stainless-steel secondary heat exchanger
- Two-stage gas valve for quiet, economical heating
- Durable Silicon Nitride igniter
- Quiet two-speed induced draft blower
- Compatible with any single-stage thermostat
- Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
- Color-coded low-voltage terminals with provisions for electronic air cleaner
- Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand
- Multiple continuous fan speed options for quiet air circulation
- Auto-Comfort and enhanced dehumidification modes available
- All models comply with California 40 ng/J Low NOx emissions standard
- Note: Not available for installation in California's South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019.
Cabinet Features
- Designed for multi-position installation: upflow, horizontal left or right
- Certified for direct vent (2-pipe) or non-direct vent (1-pipe)
- Easy to install top venting with optional side venting
- Convenient left or right connection for gas and electrical service
- Cabinet air leakage (QLeak) ≤ 2%
- Heavy-gauge steel cabinet with durable baked-enamel finish
- Fully insulated heat exchanger and blower section
- Airtight solid bottom or side-return with easy-cut tabs for effortless removal in bottom air-inlet applications
Nomenclature Explained
The model number indicates specific features:
Code | Feature | Description |
---|---|---|
G | Brand | Goodman Brand |
R/D | Configuration | R - Upflow/Horizontal, D - Downflow/Horizontal |
V/9 | Motor | V - Variable Speed ECM, 9 - Nine Speed ECM |
T/S/M | Gas Valve | T - 2 Stage, S - Single Stage, M - Modulating |
96 | AFUE | 96% AFUE |
060/080/100/120 | MBTU/h | Capacity in thousands of BTU/h (e.g., 060 = 60,000 BTU/h) |
3/4/5 | No. of Burners / Max CFM | Indicates number of burners or maximum CFM (e.g., 3 = 3 burners, 4 = 1600 CFM) |
B/N/X/U | NOx | B - Standard NOx, N - Low NOx (90%+), X - Low NOx (80%), U - Ultra Low NOx |
A/B/C/D | Cabinet Width | A - 14", B - 17½", C - 21", D - 24½" |
A/B | Minor Revision | A - Initial Release, B - 1st Revision |
A/B | Major Revision | A - Initial Release, B - 1st Revision |
Product Specifications
GRVT96 Series
Model | Heating Input (BTU/h) | Heating Output (BTU/h) | Low-Fire Input (BTU/h) | Low-Fire Output (BTU/h) | AFUE (%) | Temp Rise Range (°F) High/Low | Vent Diameter | No. of Burners | Circulator Blower (HP) | Min. Circuit Ampacity (A) | Max. O.C. Device (A) | Shipping Weight (lbs) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
GRVT960403BN | 40,000 | 38,440 | 28,000 | 26,908 | 96.1 | 20-50 / 20-50 | 2" - 3" | 2 | 1/2 | 7.6 | 15 | 114 |
GRVT960603BN | 60,000 | 57,660 | 42,000 | 40,362 | 96.1 | 35-65 / 35-65 | 2" - 3" | 3 | 1/2 | 7.6 | 15 | 117 |
GRVT960803BN | 80,000 | 76,880 | 56,000 | 53,816 | 96.1 | 35-65 / 35-65 | 2" - 3" | 4 | 1/2 | 7.6 | 15 | 120 |
GRVT960804CN | 80,000 | 76,880 | 56,000 | 53,816 | 96.1 | 35-65 / 35-65 | 2" - 3" | 4 | 3/4 | 10.9 | 15 | 141 |
GRVT961005CN | 100,000 | 96,100 | 70,000 | 67,270 | 96.1 | 35-65 / 35-65 | 2" - 3" | 5 | 1 | 13.9 | 20 | 143 |
GRVT961005DN | 100,000 | 96,100 | 70,000 | 67,270 | 96.1 | 30-60 / 30-60 | 2" - 3" | 5 | 1 | 13.9 | 20 | 153 |
GRVT961205DN | 120,000 | 115,320 | 84,000 | 80,724 | 96.1 | 35-65 / 35-65 | 2" - 3" | 6 | 1 | 13.9 | 20 | 156 |
GDVT96 Series
Model | Heating Input (BTU/h) | Heating Output (BTU/h) | Low-Fire Input (BTU/h) | Low-Fire Output (BTU/h) | AFUE (%) | Temp Rise Range (°F) High/Low | Vent Diameter | No. of Burners | Circulator Blower (HP) | Min. Circuit Ampacity (A) | Max. O.C. Device (A) | Shipping Weight (lbs) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
GDVT960403BN | 40,000 | 38,440 | 28,000 | 26,908 | 96.1 | 35-65 / 25-55 | 2" - 3" | 2 | 1/2 | 7.6 | 15 | 116 |
GDVT960603BN | 60,000 | 57,660 | 42,000 | 40,362 | 96.1 | 20-50 / 20-50 | 2" - 3" | 3 | 1/2 | 7.6 | 15 | 119 |
GDVT960804CN | 80,000 | 76,880 | 56,000 | 53,816 | 96.1 | 35-65 / 35-65 | 2" - 3" | 4 | 3/4 | 10.9 | 15 | 143 |
GDVT961005CN | 100,000 | 96,100 | 70,000 | 67,270 | 96.1 | 35-65 / 35-65 | 2" - 3" | 5 | 1 | 13.9 | 20 | 145 |
GDVT961205DN | 120,000 | 115,320 | 84,000 | 80,724 | 96.1 | 35-65 / 35-65 | 2" - 3" | 6 | 1 | 13.9 | 20 | 158 |
Notes:
- Natural Gas BTU/h ratings are for altitudes 0-4500' above sea level; reduce input rating by 4% for each 1000' above 4500'.
- DOE AFUE is based upon Isolated Combustion System (ICS).
- Vent and combustion air diameters may vary based on vent length. Refer to the latest National Fuel Gas Code (NFPA 54/ANSI Z223.1 in USA, CAN/CSA B149.1/B142.2 in Canada).
- Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size determined by National Electrical Codes; extensive wire runs may require larger sizes.
- Maximum Overcurrent Protection Device is the maximum recommended fuse or circuit breaker size.
- All furnaces operate on 115 VAC, 60 Hz, single-phase electrical supply.
- Gas Service Connection: 1½" FPT.
- Ensure proper wire sizing and electrical connections per NEC and local codes.
- For bottom return, failure to unfold flanges can reduce airflow by up to 18%, potentially affecting performance and noise.
- A 24" front clearance is required for servicing/cleaning. Unit connections may require greater clearances than listed; accessibility clearance takes precedence.
Dimensions
The following tables detail the physical dimensions and minimum clearances to combustible materials for the GRVT96 and GDVT96 series furnaces.
GRVT96 Series Dimensions (in inches)
Model | W | D | H | Air Discharge (A, B, C) | Air Return (D, E) |
---|---|---|---|---|---|
GRVT960403BN | 17½" | 28%" | 34½" | A: 17½", B: 16", C: 13%" | D: 12%", E: 13%" |
GRVT960603BN | 17½" | 28%" | 34½" | A: 17½", B: 16", C: 13%" | D: 12%", E: 13%" |
GRVT960803BN | 17½" | 28%" | 34½" | A: 17½", B: 16", C: 13%" | D: 12%", E: 13%" |
GRVT960804CN | 21" | 28%" | 34½" | A: 21", B: 19½", C: 17" | D: 16", E: 17½" |
GRVT961005CN | 21" | 28%" | 34½" | A: 21", B: 19½", C: 17%" | D: 16", E: 17½" |
GRVT961005DN | 24½" | 28%" | 34½" | A: 24½", B: 23", C: 20%" | D: 19%", E: 20%" |
GRVT961205DN | 24½" | 28%" | 34½" | A: 24½", B: 23", C: 20%" | D: 19%", E: 20%" |
GDVT96 Series Dimensions (in inches)
Model | W | D | H | Air Return (A, B, C) | Air Discharge (D, E) |
---|---|---|---|---|---|
GDVT960403BN | 17½" | 28%" | 34½" | A: 17½", B: 14%", C: 14" | D: 14½", E: 16" |
GDVT960603BN | 17½" | 28%" | 34½" | A: 17½", B: 14%", C: 14" | D: 14½", E: 16" |
GDVT960804CN | 21" | 28%" | 34½" | A: 21", B: 18%", C: 17½" | D: 18", E: 19½" |
GDVT961005CN | 21" | 28%" | 34½" | A: 21", B: 18%", C: 17½" | D: 18", E: 19½" |
GDVT961205DN | 24½" | 28%" | 34½" | A: 24½", B: 215%", C: 21" | D: 21½", E: 23" |
Minimum Clearances to Combustible Materials (in inches)
Upflow Installation
Position | Sides | Rear | Front | Bottom | Flue | Top |
---|---|---|---|---|---|---|
Upflow | 0" | 0" | 3" | C | 0" | 1" |
Horizontal | 6" | 0" | 3" | C | 0" | 6" |
C = If placed on combustible floor, the floor MUST be wood ONLY.
Downflow Installation (GDVT96 Series)
Position | Sides | Rear | Front | Bottom | Flue | Top |
---|---|---|---|---|---|---|
Downflow | 0" | 0" | 3" | NC | 0" | 1" |
Horizontal | 6" | 0" | 3" | C | 0" | 6" |
NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.
Airflow Data
The following tables provide airflow (CFM) and temperature rise (RISE) data for various models under different conditions. Formulas for calculation are provided: BTU/h Output = CFM x 1.08 x Rise.
GRVT96 / GDVT96 Airflow Data (Heating)
Model / Temp Rise Range (Mid-Rise) | GDVT960403BNA* | GDVT960603BNA* | GDVT960804CNA* | GDVT961005CNA* | GDVT961205DNA* | GRVT960403BNA* | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | |
Recommended CFM for High Heat / Expected Temp Rise | 710 | 50 | 1400 | 38 | 1425 | 50 | 1770 | 50 | 2150 | 50 | 1010 | 35 |
Lowest Recommended CFM for High Heat / Expected Temp Rise | 548 | 65 | 1072 | 50 | 1095 | 65 | 1360 | 65 | 1650 | 65 | 710 | 50 |
Model / Temp Rise Range (Mid-Rise) | GRVT960603BNA* | GRVT960803BNA* | GRVT960804CNA* | GRVT961005CNA* | GRVT961005DNA* | GRVT961205DNA* | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | |
Recommended CFM for High Heat / Expected Temp Rise | 1072 | 50 | 1400 | 50 | 1425 | 50 | 1770 | 50 | 1980 | 45 | 2150 | 50 |
Lowest Recommended CFM for High Heat / Expected Temp Rise | 820 | 65 | 1090 | 65 | 1095 | 65 | 1360 | 65 | 1480 | 60 | 1650 | 65 |
Note: Low Heat CFM = High Heat CFM x 0.7. Low Heat Temperature Rise is expected to equal High Heat Temperature Rise ± 5%.
Cooling Speed Airflow Data (@ 0.1" - 0.8" w.c. ESP)
Model | Tons | High-Stage | Low-Stage | |||
---|---|---|---|---|---|---|
CFM | CFM | |||||
GRVT960403BNA*, GRVT960603BNA*, GRVT960803BNA*, GDVT960403BNA*, GDVT960603BNA* | 1.5 | 600 | 420 | |||
2 | 800 | 560 | 2 | 800 | 560 | |
2.5 | 1,000 | 700 | 2.5 | 1,000 | 700 | |
3 | 1,200 | 840 | 3 | 1,200 | 840 | |
MAX | 1,400 | MAX | 1,760 | |||
GRVT960804CNA*, GDVT960804CNA* | 2 | 800 | 560 | 2 | 800 | 560 |
2.5 | 1,000 | 700 | 2.5 | 1,000 | 700 | |
3 | 1,200 | 840 | 3 | 1,200 | 840 | |
4 | 1,600 | 1,120 | 4 | 1,600 | 1,120 | |
MAX | 1,760 | MAX | ||||
GRVT961005CNA*, GRVT961005DNA*, GDVT961005CNA*, GDVT961205DNA* | 2 | 800 | 560 | 2 | 800 | 560 |
3 | 1,200 | 840 | 3 | 1,200 | 840 | |
4 | 1,600 | 1,120 | 4 | 1,600 | 1,120 | |
5 | 2,000 | 1,400 | 5 | 2,000 | 1,400 | |
MAX | 2,200 | MAX | 2,200 |
All furnaces ship as high speed for cooling; installer must adjust blower speed as needed. For most jobs, approximately 400 CFM per ton is desirable for cooling. Do not operate above 0.5" w.c. ESP in heating mode.
Temperature Rise Range Chart
A graphical representation of BTU Output vs. Temperature Rise, showing relationships between output, temperature rise, and airflow (CFM). Key formulas are: BTU/h Output = CFM x 1.08 x Rise, and Rise = BTU/h Output / (CFM x 1.08).
Wiring Diagram & Controls
The wiring diagram illustrates the electrical connections for the furnace. Key components include:
- High Voltage (115V) and Low Voltage (24V) connections
- Integrated Control Board
- Transformer (40 VA)
- Igniter (Hot Surface Igniter)
- Induced Draft Blower
- Circulator Blower Motor (ECM)
- Two-Stage Gas Valve
- Pressure Switches (High Fire, Low Fire)
- Flame Sensor
- Limit Controls (Primary Auto Reset, Rollout Manual Reset)
- Condensate Switch (Optional)
- Junction Box and terminal connections
Menu Navigation & Airflow Settings: Configuration can be performed via a phone application over Bluetooth using the CoolCloud app or using on-board push buttons. Settings include Tonnage Menu for cooling/heat pump airflow, Cooling Trim (CTF), Heating Trim (HTF), Constant Fan (FSD), and Cooling Airflow Profile (CAP).
Important Notes:
- Always disconnect power before servicing.
- Wiring must be properly polarized and grounded.
- Use manufacturer-specified replacement parts.
- If replacing original wiring, use conductors rated for at least 105°C.
- Unit must be permanently grounded per NEC and local codes.
- When paired with non-R-32 refrigerant systems, default settings may need adjustment. Refer to the installation manual.
Wire Color Designations: WH (White), BK (Black), YL (Yellow), BL (Blue), RD (Red), OR (Orange), BR (Brown), TN (Tan), PK (Pink), GY (Gray), GR (Green), PU (Purple), VT (Violet).
Available Accessories
The following accessories are available for the GRVT96 and GDVT96 series:
GRVT96 Series Accessories
Model | Description | 0403BN | 0603BN | 0803BN | 0804CN | 1005CN | 1005DN | 1205DN |
---|---|---|---|---|---|---|---|---|
72950 | Concentric Vent Kit (2") | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
72951 | Concentric Vent Kit (3") | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
RF000142 | Drain Kit Horizontal Left Vertical Flue | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
EFRO2 | External Filter Rack with 16"x25" Permanent Filter | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
0170K00000S | Flush Mount Vent Kit - 3" or 2" | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
0170K00001S | Flush Mount Vent Kit - 2" | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
HASFK | High-Altitude Natural Gas Kit | HASFK-1 | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-3 | TBD | HASFK-2 |
HASFK | High-Altitude LP Gas Kit | HASFK-1 | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-2 | TBD | HASFK-2 |
0270F05404 | Horizontal Drain Tubing Kit | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
LPM-34 | LP Conversion Kits | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
GDVT96 Series Accessories
Model | Description | 0403BN | 0603BN | 0804CN | 1005CN | 1205DN |
---|---|---|---|---|---|---|
72950 | Concentric Vent Kit (2") | ✓ | ✓ | ✓ | ✓ | ✓ |
72951 | Concentric Vent Kit (3") | ✓ | ✓ | ✓ | ✓ | ✓ |
CFSB17 | Downflow Sub-Base 17.5" | ✓ | ✓ | |||
CFSB21 | Downflow Sub-Base 21" | ✓ | ✓ | |||
CFSB24 | Downflow Sub-Base 24" | ✓ | ||||
RF000142 | Drain Kit Horizontal Left Vertical Flue | ✓ | ✓ | ✓ | ✓ | ✓ |
0170K00000S | Flush Mount Vent Kit - 3" or 2" | ✓ | ✓ | ✓ | ✓ | ✓ |
0170K00001S | Flush Mount Vent Kit - 2" | ✓ | ✓ | ✓ | ✓ | ✓ |
HASFK | High-Altitude Natural Gas Kit | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-3 | HASFK-3 |
HASFK | High-Altitude LP Gas Kit | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-2 | HASFK-3 |
0270F05405 | Horizontal Drain Tubing Kit | ✓ | ✓ | ✓ | ✓ | ✓ |
LPM-34 | LP Conversion Kits | ✓ | ✓ | ✓ | ✓ | ✓ |
✓ Indicates available for this model.
Warranty & Certifications
Warranty: Complete warranty details are available from local dealers or at www.goodmanmfg.com. Key warranties include Lifetime Heat Exchanger Limited Warranty, 10-Year Unit Replacement Limited Warranty, and 10-Year Parts Limited Warranty. Online registration is required within 60 days of installation (exceptions apply in certain states/provinces).
Certifications & Recognitions:
- ENERGY STAR®
- ComfortBridge™ Technology
- CoolCloud™
- R32
- ETL LISTED
- AHRI CERTIFIED
- ISO 9001 Certified
- ISO 14001 Certified