SALUS 091FL/091FLRF Digital Programmable Thermostat
Introduction
The SALUS 091FL/091FLRF is a programmable, weekly thermostat designed to control room temperature in heating or cooling systems. Please read this manual carefully before use. Only use AA 1.5V alkaline batteries. Do not use rechargeable batteries. Batteries are located in the slot under the cover.
Product Compliance
This product complies with the following EU Directives:
- 091FL: 2014/30/EU, 2014/35/EU, 2011/65/EU
- 091FLRF: 2011/65/EU, 2014/53/EU (868.0 MHz - 868.6 MHz; <13dBm)
Full information is available at www.saluslegal.com.
Safety Information
Use the device in accordance with national and EU regulations. Use only as intended and keep it dry. This product is for indoor use only. Installation must be performed by a qualified person according to national and EU regulations.
Technical Specifications
Wired Thermostat 091FL
Parameter | Value |
---|---|
Power supply | 2 x AA batteries |
Rating max | 5 (3) A |
Outputs | Voltage-free NO/COM relay |
Temperature range | 5-30°C |
Wireless Thermostat 091FLRF
Parameter | Value |
---|---|
Thermostat supply | 2 x AA batteries |
Receiver supply | 230 V AC 50 Hz |
Receiver rating max | 16 (5) A |
Receiver outputs | Voltage-free NO/COM relay |
Temperature range | 5-30°C |
Proper Thermostat Placement
Diagram showing ideal thermostat placement on a wall, approximately 150 cm from the floor and at least 20 cm from corners or heat sources.
Button Functions
Button | Function |
---|---|
D | Set the day of the week |
H | Set the hour |
M | Set the minutes |
Temp | Temperature setpoint |
Prog | Weekly programming |
Prog # | Program selection |
OK | Confirm function |
•Reset | Factory Reset |
LCD Icon Description
Description of icons displayed on the thermostat screen:
- 1. Day of the week indicator
- 2. Heating Mode ON
- 3. Cooling Mode ON
- 4. Room/setpoint temperature
- 5. Temperature unit (°C)
- 6. Controlled device working status (e.g., boiler)
- 7. Temporary override
- 8. Eco Mode
- 9. Program number
- 10. Antifrost Mode
- 11. Comfort Mode
- 12. Program timeline indicator
- 13. Clock
- 14. Low battery indicator ?
- 15. AM/PM
Wiring Diagrams
091FL Wiring Diagram
Diagram shows connections for the wired thermostat 091FL. Terminals: L (Live), N (Neutral), COM (Common), NO (Normally Open). The MAX terminal indicates the maximum load rating.
091FLRF Wiring Diagram
Diagram shows connections for the wireless thermostat 091FLRF receiver (RXRT510). Terminals: L (Live), N (Neutral), COM (Common), NO (Normally Open). The MAX terminal indicates the maximum load rating.
Changing Communication Code (091FLRF)
To prevent interference from other wireless devices, it is recommended to change the communication code from the factory setting. Use DIP switches (numbered 1-5) on both the receiver and transmitter. Ensure they are in the same position on both units. Press the Reset button after changing the code.
Setting Time
Press OK to highlight the display. Use D to set the day, H to set the hour, and M to set the minutes. Press OK to confirm.
Setting Temperatures
Comfort Temperature
Press OK to highlight. Use the [increase] and [decrease] buttons to adjust the current comfort temperature. Press OK to confirm.
Economic Temperature
Press OK to highlight. Use the [increase] and [decrease] buttons to adjust the current economic temperature. Press OK to confirm.
Programming
There are 9 available programs: Programs 0-5 are factory pre-set, and Programs 6-8 can be user-defined.
Selecting Factory Programs (0-5)
Press OK to highlight. Use the Prog button to select the day of the week. Use Prog # to set the program number (0-5) for the selected day. Program 0 sets the thermostat to antifrost temperature (7°C) for the entire day. Press OK to confirm.
Choosing and Programming User Programs (6-8)
Press OK to highlight. Use the Prog button to select the day of the week. Use Prog # to set the program number (6, 7, or 8) for the selected day. Use the [increase] and [decrease] buttons to adjust the timeline by one hour, assigning either a comfortable or an economic temperature for that hour. Press OK to confirm.
Note: A label with program descriptions is located on the flip side of the cover.
Service Menu
Press OK to highlight the display. Hold the OK button for 5 seconds to enter the service menu.
- Mode: Heating (relay closes when heating is needed) or Cooling (relay closes with a 5-minute delay). Select using [increase]/[decrease] buttons and confirm with OK.
- Heating Device Delay Switch: DLY OFF (disabled) or DLY ON (5 min delay). Select using [increase]/[decrease] buttons and confirm with OK.
- Temperature Span: Select between 0.5°C or 1.0°C (default 1.0°C). Use [increase]/[decrease] buttons and confirm with OK.
- Temperature Correction: Adjust measured temperature by -3.0°C to +3.0°C (default 0.0°C). Use [increase]/[decrease] buttons and confirm with OK. (Feature available from software version 2.4).