AUVON Lancing Device User Manual

Instructions for Lancing Device Use

This guide provides step-by-step instructions for using your AUVON Lancing Device.

Step-by-Step Guide:

  1. Preparation: Wash your hands thoroughly with soap and warm water, then dry them. Remove the cap from the lancing device.

    [Illustration: Hands being washed and dried, lancing device cap removed]

  2. Insert Lancet: Insert a new lancet into the lancet carrier. Push down firmly until it is fully secured.

    [Illustration: Lancet inserted into device, pushed until secured]

  3. Remove Lancet Cap: Twist off the lancet's protective cap. Save the cap for later use.

    [Illustration: Lancet's protective cap being twisted off]

  4. Replace Cap: Snap the protective cap back onto the device.

    [Illustration: Protective cap snapped back onto device]

  5. Adjust Depth: Choose the desired penetration depth for your skin type to ensure a good blood sample with minimal discomfort. Adjustment settings are:

    • 0-1: Soft or delicate skin
    • 2-3: Normal skin
    • 4-5: Thick or callused skin

    [Illustration: Penetration depth adjustment dial with settings 0-5]

  6. Cock the Device: Pull the plunger of the lancing device until it clicks. The device is now prepared and ready for use. An indicator on the device will show if it is properly launched.

    [Illustration: Device plunger pulled back until it clicks]

  7. Perform Puncture: Hold the lancing device firmly against the site on your finger. Press the trigger to puncture the skin. The first drop of blood may contain tissue fluid and serum, which can affect test results; discard this drop. Squeeze your fingertip gently to obtain the second blood sample.

    [Illustration: Device against fingertip, trigger pressed]

  8. Finish: When finished, remove the cap of the lancing device. Use the protective cap to cover the needle, then eject and discard the used lancet.

    [Illustration: Protective cap covering needle, lancet ejected and discarded]

Important Information

  • The lancing device and lancets are for single patient use only. Do not share with others, including family members, and do not use on multiple patients.
  • To improve blood flow, use warm water before testing if necessary. Dry your hands and the test site thoroughly.
  • Clean the test site with an alcohol swab or soapy water. Ensure your hands are clean and dry, and gently massage the test site before collecting blood.
  • Keep the lancing device clean and free from cream, lotion, or dust.
  • Always use a new and sterile lancet for each test. Do not reuse lancets.
  • To prevent accidental stab wounds, the lancet can only be released when triggered and will automatically withdraw back into the device after use.

Care for the Lancing Device

Clean the lancing device using a soft cloth with mild soap and warm water as needed. Carefully dry the lancing device. Do not immerse the lancing device in liquid.

Customer Service

  • 24-Month Limited Warranty
  • Lifetime Technical Support

Contact Details

AUVON CUSTOMER SERVICE

EMAIL: SUPPORT@IAUVON.COM

PDF preview unavailable. Download the PDF instead.

AUVON Lancing Device-211130 1 ?v=1673517575 Adobe PDF library 15.00 Adobe Illustrator(R) 24.0

Related Documents

Preview AUVON Blood Glucose Monitoring System Quick Guide
A concise guide to using the AUVON Blood Glucose Monitoring System, including step-by-step instructions and essential safety precautions for accurate blood glucose testing.
Preview AUVON DS-W Blood Glucose Monitoring System User Manual
Comprehensive user manual for the AUVON DS-W Blood Glucose Monitoring System, providing instructions for setup, use, and maintenance. Learn about specifications, safety precautions, and reference values for diabetes management.
Preview AUVON DS-W Blood Glucose Monitor User Manual: Accurate Blood Sugar Testing
User manual for the AUVON DS-W Blood Glucose Monitoring System. Learn how to use the device for accurate blood sugar testing, understand specifications, safety guidelines, and reference values for diabetes management. Includes links to relevant health organizations.
Preview AUVON Blood Glucose Monitoring System Quick Guide
Quick guide for the AUVON Blood Glucose Monitoring System, including step-by-step instructions for use, important safety precautions, and system information.
Preview Auvon DS-W1001002 Blood Sugar Test Kit Quick Reference Guide
Concise guide to using the Auvon DS-W1001002 High-Tech Blood Sugar Test Kit, covering memory record checking and easy 5-step operation for accurate glucose monitoring.
Preview AUVON Blood Glucose Monitor Quick Reference Guide
A concise guide on how to use the AUVON Blood Glucose Monitor, covering setting the time and date, and checking memory records and test results.
Preview AUVON DS-W Draw-In Blood Glucose Test Strips: Instructions and Specifications
Comprehensive guide to AUVON DS-W Draw-In Blood Glucose Test Strips, covering usage, precautions, accuracy, and storage for accurate blood glucose monitoring.
Preview AUVON DS-W Blood Glucose Monitoring System User Manual
This user manual provides comprehensive instructions for the AUVON DS-W Blood Glucose Monitoring System. It guides users on understanding their meter and test strips, performing tests, checking memory records, and troubleshooting common issues. The manual also explains factors affecting test accuracy and provides important notes for safe and effective use, aiding in informed diabetes management.