Lochinvar Copper-Fin Gas Fired Commercial Water Heaters: Specifications & Features

COMMERCIAL WATER HEATERS

COPPER-FIN® GAS FIRED WATER HEATERS

Product Overview

The Copper-Fin Atmospheric water heater features a simple design to deliver trouble-free installation, long-lasting durability, and prevention from lime scale buildup.

Standard Features

  • Copper Finned Tube Heat Exchanger - The heart of the Copper-Fin water heater is its copper finned tube heat exchanger. The gasketless copper tube heat exchanger design reduces the risk of leaks or system failures that are common with conventional water heaters.
  • Built-In Draft Hood - With our built-in draft hood, the Copper-Fin water heater installs easily in applications where overhead space is limited and headroom restrictions exist.
  • Loch-Heat™ Ceramic Tile - Our incredibly durable, Loch-Heat ceramic tile will not crack or split and provides the benefit of an overall water heater weight reduction of 25% over other refractory material.
  • A Better Idea™ System - The Better Idea system combines the Copper-Fin water heater with a separate round jacketed storage tank to provide a high performance water heating system.
  • Serviceability - The water heater's design allows for easy access to all major components for servicing. The heat exchanger is designed to slide out the front of the water heater for faster maintenance.
  • ASME Temperature & Pressure Relief Valve - Factory installed.
  • Warranty - 3-year limited Heat Exchanger Warranty, 1-year parts warranty. See warranty for details.

Dimensions & Specifications

Diagrams:

Front View: Depicts the front of the water heater, showing dimensions A (29-1/2" for most models), B (ranging from 15-1/2" to 52-1/2"), and C (21-1/2" for most models). Includes electrical connection and inlet/outlet ports.

Side View: Illustrates the side profile, detailing dimensions D (ranging from 6-1/4" to 9-1/2") and E (ranging from 5-1/2" to 7-1/4"), and indicating the inlet and outlet connections.

Top View: Shows the top of the unit, specifying vent size (ranging from 5" to 10"), gas connection size (1/2" to 1"), and shipping weight (ranging from 175 to 365 lbs).

Copper-Fin Water Heater Dimensions & Specifications
Model Number Input MBH GPH @ 100°F Rise A B C D E Vent Size Gas Conn. Ship. Weight
CWN090PM*90,0008729-1/2"15-1/2"21-1/2"7-3/4"6-1/4"5"1/2"175
CWN135PM*135,00013129-1/2"19-1/2"21-1/2"9-3/4"6-1/4"6"1/2"195
CWN180PM*180,00017529-1/2"23-1/2"21-1/2"11-3/4"7-1/4"7"3/4"220
CWN199PM*199,00019329-1/2"26-1/2"21-1/2"13-1/4"7-1/4"7"3/4"230
CWN201PM201,00019329-1/2"26-1/2"21-1/2"13-1/4"7-1/4"7"3/4"230
CWN225PM225,00021829-1/2"26-1/2"21-1/2"13-1/4"7-1/4"7"3/4"235
CWN270PM270,00026229-1/2"29-1/2"21-1/2"14-3/4"7-1/4"8"3/4"240
CWN315PM315,00030529-1/2"32-1/2"21-1/2"16-1/4"6-1/4"8"3/4"250
CWN360PM360,00034929-1/2"35-1/2"21-1/2"17-3/4"8-1/4"9"1"270
CWN399PM399,00038729-1/2"44-1/2"22"22-1/4"5-1/2"10"1"340
CWN500PM500,00048534-1/2"52-1/2"22"26-1/4"9-1/2"10"1"365

Notes:

  • Change 'N' to 'L' to denote L.P. gas models.
  • No deration for L.P. models.
  • Water Connections are 2" NPT on 6-1/4" centers.
  • Performance data is based on manufacturer test results.
  • *Canada Only

Detailed Standard Features

  • Built-In Draft Diverter
  • Stainless Steel Burners
  • ASME Copper Finned Tube Heat Exchanger
  • 160 psi Working Pressure
  • Gasketless Heat Exchanger Design
  • All Bronze Circulating Pump
  • Pump Delay/Freeze Protection
  • Remote Tank Thermostat
  • Glass-Lined Water Surfaces
  • Loch-Heat Ceramic Tile Combustion Chamber
  • ASME Temperature & Pressure Relief Valve
  • Terminal Strip
  • Automatic Reset High Limit
  • Manual Reset High Limit
  • Self Diagnostic Indicator Lights

Optional Equipment

  • Adjustable High Limit w/ Manual Reset
  • Contacts on any Failure (CW 315-500)
  • Contacts for Air Louvers (CW 315-500)
  • Cupro-Nickel Heat Exchanger
  • Flow Switch
  • Low Water Cut-Off
  • Stack Frame
  • PVC Venting Kit (CW 90-135)

Firing Controls

  • F1 - Standing Pilot (Standard CW 90-270)
  • F9 - Intermittent Spark Ignition (Standard CW 315-500)
  • F7 - California Code (CW 225-500)

Model Number Explanation

Example: A model number like CWN315PM indicates a 315,000 Btu/hr, natural gas Copper-Fin water heater.

Model Number Breakdown:

  • CW: Copper-Fin Water Heater
  • N: Natural Gas (L for LP Gas)
  • 315: Input MBH (Thousands of BTU per Hour)
  • PM: Pump Mount

Contact Information

Lochinvar, LLC

300 Maddox Simpson Parkway

Lebanon, Tennessee 37090

Phone: 615.889.8900

Fax: 615.547.1000

Website: Lochinvar.com

Website update 3/22 - Printed in U.S.A.

Models: COPPER-FIN, GAS-FIRED WATER HEATERS

File Info : application/pdf, 2 Pages, 679.84KB

PDF preview unavailable. Download the PDF instead.

CWN225PM

References

Adobe PDF Library 16.0.5 Adobe InDesign 17.1 (Windows)

Related Documents

Preview Lochinvar Copper-Fin II Commercial Pool Heater CP-SPEC-10 Technical Specifications
Detailed technical specifications for the Lochinvar Copper-Fin II commercial pool heater, model CP-SPEC-10, covering features, construction, controls, and certifications for pool and spa applications.
Preview Lochinvar Armor Condensing Commercial Gas Water Heaters
Lochinvar's ARMOR Commercial Condensing Water Heater offers 98% thermal efficiency with advanced features like SMART TOUCH control and CON-X-US remote connectivity. Available in five models from 1.25 to 4.0M BTU/hr, it boasts a 5:1 turndown ratio and direct-vent flexibility up to 150 feet. Suitable for indoor and outdoor installations in warm climates.
Preview Lochinvar EcoShield High Efficiency Gas Fired Condensing Water Heater User & SMART SYSTEM Control Guide
This document provides a comprehensive user and control guide for the Lochinvar EcoShield range of High Efficiency Gas Fired Condensing Water Heaters, covering operation, settings, error codes, and technical specifications.
Preview Lochinvar Commercial Gas Water Heaters: Condensing High Efficiency Models
An overview of Lochinvar's LCT-199 series of commercial gas tankless water heaters, detailing their condensing high efficiency technology, Ultra-Low NOx features, durable heat exchangers, performance specifications, and model details for indoor and outdoor installations.
Preview Lochinvar WHP185R Water Source Heat Pump Water Heater Installation Manual
Comprehensive installation manual for the Lochinvar WHP185R Water Source Heat Pump Water Heater, covering safety, specifications, installation procedures, and troubleshooting for efficient commercial hot water solutions.
Preview Lochinvar TTW Series: Gas Fired Condensing Water Heater Installation & Maintenance Manual
Comprehensive installation, commissioning, user, and maintenance guide for Lochinvar TTW410 and TTW580 floor-standing gas-fired condensing circulating type water heaters. Features technical data, safety guidelines, and operational procedures.
Preview Lochinvar EcoForce++ High Efficiency Gas Fired Condensing Water Heaters: Installation, Commissioning, and Maintenance Instructions
This document provides comprehensive installation, commissioning, and maintenance instructions for the Lochinvar EcoForce++ range of high-efficiency gas-fired condensing water heaters. It details technical specifications, safety requirements, flue system guidelines, electrical connections, troubleshooting procedures, and maintenance schedules for models EF+35/150+, EF+35/230+, and EF+55/230+.
Preview Lochinvar EcoSword Gas-Fired Water Heaters: High Efficiency & Performance
Discover the Lochinvar EcoSword series, featuring high-efficiency, storage-type gas-fired water heaters designed for superior performance. Suitable for natural gas or LPG, these units are also 20% hydrogen ready.