Cooper&Hunter Air Conditioner: CH-RES09-115VO + CH-R09OLVWM-115VI

This document provides technical specifications and key features for the Cooper&Hunter split system air conditioner models CH-RES09-115VO and CH-R09OLVWM-115VI.

Key Features

Product Overview & Certifications

The product includes both an indoor and an outdoor unit. It is certified by AHRI, ENERGY STAR, and Intertek, and features R454B refrigerant compatibility and GoldFin technology.

Indoor Unit Specifications (CH-R09OLVWM-115VI)

ParameterValueUnit
ModelCH-R09OLVWM-115VI
Power Supply115V, 1Ph, 60Hz
Communication WiringAWG 14-4
Cooling Capacity9,000 (2,600~13,000)Btu/h
Cooling Input660 (180~1,080)W
Cooling Rated Current6.9 (1.9~9.8)A
Cooling EER/EER2Btu/w
Cooling SEER/SEER2Btu/w
Heating Capacity at 47 °F10,000 (4,500~12,800)Btu/h
Heating Input at 47 °F698 (280~980)W
Heating Rated Current at 47 °F7.6 (1.5~9.2)A
Heating COP at 47 °F4.2W/W
HSPF4/HSPF2-410.7
HSPF5/HSPF2-58.2
Indoor Fan Motor Qty1
Indoor Fan Motor Input20W
Indoor Fan Motor RLA0.6A
Indoor Air Flow (Turbo/Hi/Med/Lo)370.8 / 306.1 / 235.4 / 188.4CFM
ESP (range)/In.wg.
Indoor Noise Level (Hi/Med/Lo)40.5/35/26.5dB(A)
Dehumidification1.69L/H
Indoor Unit Dimensions (WxDxH)31.57 x 7.87 x 11.61inch
Indoor Unit Packing (WxDxH)34.45 x 11.22 x 14.96inch
Indoor Unit Net/Gross Weight19.84/26.01lbs
Drainage Water Pipe Diameter5/8"inch
Refrigerant Piping (Liquid/Gas)1/4"/3/8"inch
Design Pressure550/340PSIG
ControllerRemote Controller
Room Temperature (Cooling)60~90F
Room Temperature (Heating)32~86F

Outdoor Unit Specifications (CH-RES09-115VO)

ParameterValueUnit
ModelCH-RES09-115VO
Power Supply115V, 1Ph, 60Hz
Min. Circuit Ampacity18A
Max. Fuse20A
Compressor ModelKSK103D33UEZ3
Compressor TypeROTARY
Compressor BrandGMCC
Compressor Capacity11.1Btu/h
Compressor Input826W
Compressor Rated Current (RLA)14A
Refrigerant OilVG74 10.5oz
Outdoor Fan Motor Qty1
Outdoor Fan Motor Input34W
Outdoor Fan Motor RLA0.6A
Outdoor Fan Speed850/700/600r/min
Outdoor Air Flow (Max)1,235.3CFM
Outdoor Noise Level (Max)53dB(A)
Throttle TypeEXV
Outdoor Unit Dimensions (WxDxH)30.12 x 11.93 x 21.85inch
Outdoor Unit Packing (WxDxH)34.92 x 13.27 x 24.02inch
Outdoor Unit Net/Gross Weight64.59/70.11inch
Refrigerant TypeR454B
Refrigerant Precharge25ft
Additional Charge for 1/4 inch Liquid Pipe0.16oz
Additional Charge for 3/8 inch Liquid Pipe/oz
Refrigerant Piping (Liquid/Gas)1/4"/3/8"inch
Max. Pipe Length82ft
Max. Difference in Level49.2ft
Ambient Temperature (Cooling)-13 ~ 122F
Ambient Temperature (Heating)-13~75F

Installation Dimensions and Notes

Indoor Unit Installation:The document illustrates selecting an installation location for the indoor unit, detailing required clearances and dimensions. It highlights four options for the piping exit direction (left rear, right rear, left-hand side, right-hand side) based on the wall hole's position relative to the mounting plate.

Indoor Unit Dimensions: The indoor unit measures 31.7in (806mm) in width and 11.65in (296mm) in height. Diagrams indicate necessary clearances, such as 4-3/4" (12cm) from the top and bottom.

Wall Hole Requirement: For pipes with a gas side diameter of 5/8in (16mm) or larger, the wall hole should be 3-1/2in (90mm).

Outdoor Unit Dimensions: Key dimensions for the outdoor unit include Width (W) of 30-1/8in (765mm), Width 1 (W1) of 32-7/8in (835mm), Width 3 (W3) of 30-7/8in (784mm), Height (H) of 21-7/8in (555mm), and Depth (D) of 11-7/8in (303mm). Additional specific dimensions (A, B, C, D, A1, A2) are also provided.

PDF preview unavailable. Download the PDF instead.

CH-RES09-115VO CH-R09OLVWM-115VI

Related Documents

Preview Cooper&Hunter CH-RLS06MIA-115VO & CH-RLS06MIA-115VI Air Conditioner Specifications and Dimensions
Detailed technical specifications, features, and dimensional drawings for Cooper&Hunter CH-RLS06MIA-115VO and CH-RLS06MIA-115VI air conditioning units. Includes indoor and outdoor unit data, refrigerant information, and installation considerations.
Preview Cooper&Hunter Air Conditioner: CH-RLS09MIA-115VO & CH-RLS09MIA-115VI Technical Specifications and Dimensions
Detailed technical specifications, key features, and dimensional diagrams for the Cooper&Hunter CH-RLS09MIA-115VO and CH-RLS09MIA-115VI air conditioning units. Includes cooling and heating capacities, electrical data, noise levels, and installation guidance.
Preview Cooper&Hunter CH-RES09-230VO + CH-R09MOLVWM-230VI Air Conditioner Specifications
Detailed specifications and key features for the Cooper&Hunter CH-RES09-230VO and CH-R09MOLVWM-230VI split system air conditioner, including cooling/heating capacity, power requirements, dimensions, and performance data.
Preview Cooper&Hunter MIA Split-Type Room Air Conditioner Owner's Manual
Comprehensive owner's manual for Cooper&Hunter MIA Series Split-Type Room Air Conditioners. Includes installation guides, safety precautions, operation instructions, maintenance, and troubleshooting for models like CH-RLS06MIA, CH-RLS09MIA, CH-RLS12MIA, CH-RLS18MIA, and CH-RLS24MIA.
Preview Cooper&Hunter CH-RES09-230VO + CH-RH09MCT Air Conditioner Specifications
Detailed technical specifications and dimensions for the Cooper&Hunter CH-RES09-230VO + CH-RH09MCT split system air conditioner, including key features and performance data.
Preview Cooper&Hunter CH-ES24-230VO + CH-M24AHU Split System Air Conditioner Specifications
Detailed specifications and features for the Cooper&Hunter CH-ES24-230VO and CH-M24AHU split system air conditioner, including performance, operational temperatures, and unit dimensions.
Preview Cooper&Hunter CH-REL30-230VO + CH-RS30MAHU Air Conditioner Specifications
Detailed technical specifications, key features, and dimensions for the Cooper&Hunter CH-REL30-230VO + CH-RS30MAHU split system air conditioner.
Preview Cooper&Hunter CH-R48LCU-230VO + CH-RSH48LCFC Air Conditioner Technical Specifications
Detailed technical specifications, key features, and dimensional information for the Cooper&Hunter CH-R48LCU-230VO + CH-RSH48LCFC split system air conditioner, including performance data and unit measurements.