Cooper&Hunter CH-REL30-230VO + CH-RS30MAHU

Brand: Cooper&Hunter

Key Features

Certifications

Product Overview

The Cooper&Hunter CH-REL30-230VO + CH-RS30MAHU is a split system air conditioner designed for efficient cooling and heating. The system comprises an indoor unit (CH-RS30MAHU) and an outdoor unit (CH-REL30-230VO).

Indoor Unit Description: The indoor unit is a tall, rectangular cabinet in a grey finish, featuring visible vents or grilles on its front and sides for airflow intake and output, along with access panels. It is designed for installation within a building's conditioned space.

Outdoor Unit Description: The outdoor unit is a rectangular, grey unit designed for external placement. It features a prominent circular fan grille on its top surface and side panels with fins for heat exchange. This unit houses the compressor and other components responsible for heat rejection or absorption.

Indoor Unit Specifications (CH-RS30MAHU)

Specification Value
Indoor ModelCH-RS30MAHU
Power supply208-230V, 1Ph, 60Hz
Communication wiringAWG 14-4
Cooling Capacity30,000 Btu/h (9,200~34,000)
Cooling Input2,730 W (300~3,400)
Cooling Rated current12.5 A (2.51~15)
EER/EER211 Btu/w
SEER/SEER217 Btu/w
Heating Capacity30,000 Btu/h (8,500~33,000)
Heating Input2,440 W (370~2,700)
Heating Rated current11.2 A (2.92~11.9)
COP3.6 W/W
HSPF4/HSPF2-48.7
HSPF5/HSPF2-57
Indoor fan motor Qty1
Indoor fan motor Input375 W
Indoor fan motor RLA4.5 A
Indoor air flow (Turbo/Hi/Med/Lo)988.8 / 894.7 / 806.4 / 712.2 CFM
ESP (range)0-0.8 In.wg.
Indoor noise level (Hi/Med/Lo)44/41/26 dB(A)
Dehumidification7.4 Pnt/H
Indoor unit Dimensions (WxDxH)21.02 x 21.02 x 49.02 inch
Indoor unit Packing (WxDxH)24.41 x 26.57 x 52.56 inch
Indoor unit Net/Gross weight127.43/151.68 lbs
Drainage water pipe diameter3/4" inch
Refrigerant piping (Liquid side/Gas side)3/8"/5/8" inch
Design pressure550/340 PSIG
ControllerWire controller + remote controller available
Room temperature Cooling60~90 F
Room temperature Heating32~86 F

Outdoor Unit Specifications (CH-REL30-230VO)

Specification Value
Outdoor ModelCH-REL30-230VO
Power supply208-230V, 1Ph, 60Hz
Min. circuit ampacity28 A
Max. fuse30 A
Compressor ModelKTF250D22UMT
Compressor TypeROTARY
Compressor BrandGMCC
Compressor Capacity27,620 Btu/h
Compressor Input2,200 W
Compressor Rated current (RLA)17.5 A
Refrigerant oilVG74 22.7 oz
Outdoor fan motor Qty1
Outdoor fan motor Input120 W
Outdoor fan motor RLA1.3 A
Outdoor fan motor Speed900/700/500 r/min
Outdoor air flow (Max)2,236.7 CFM
Outdoor noise level (Max)61 dB(A)
Throttle typeEXV+Capillary
Outdoor unit Dimensions (WxDxH)37.24 x 16.14 x 31.89 inch
Outdoor unit Packing (WxDxH)42.91 x 19.68 x 34.84 inch
Outdoor unit Net/Gross weight142.86/154.54 lbs
Refrigerant TypeR454B
Refrigerant Precharge25 ft
Additional charge for 1/4 inch liquid pipe0.32 oz
Refrigerant piping (Liquid side/Gas side)3/8"/5/8" inch
Refrigerant piping Max. pipe length164 ft
Refrigerant piping Max. difference in level82 ft
Ambient temperature Cooling-13 ~ 122 F
Ambient temperature Heating-13 ~ 75 F

Unit Dimensions and Piping Details

Indoor Unit Piping Plate Diagram Description

This diagram details the piping and connections on the indoor unit. It shows a 'PIPING PLATE' with labeled connection points for 'SUCTION LINE' and 'LIQUID LINE' using 3/8" and 5/8" flare connections respectively. It illustrates multiple 'CONDENSATE DRAINS' for horizontal, upflow, and downflow configurations, with primary and secondary (emergency) drain pipes specified as 3/4" FPT. The diagram also indicates 'FILTER ACCESS' and a 'FILTER COVER', as well as a 'CIRCUIT BREAKER COVER' for auxiliary heater connections. Various inlet points for electrical wiring are marked, including 'LOW VOLTAGE INLETS' and 'LINE VOLTAGE INLETS', with notes specifying that strong electricity and communication wires should not use the same knock hole.

Indoor Unit Airflow and Electrical Inlet Description

The indoor unit features a 'SUPPLY AIR OPENING' for conditioned air distribution. It also has designated 'LOW VOLTAGE INLETS' (located on the top and left side) and 'LINE VOLTAGE INLETS' (located on the top and right side) for electrical connections. A note indicates that separate knock holes should be used for strong electricity wiring and communication wiring.

Outdoor Unit Dimensions Description

This diagram provides the external dimensions for the outdoor unit in both inches and millimeters. It includes side views showing height (31-7/8in / 810mm) and depth (16-1/8in / 410mm), and front views showing width (37-1/4in / 946mm) and height (26-1/2in / 673mm). A top view is also provided, showing the overall width (40-1/2in / 1030mm) and depth (15-1/4in / 386mm). Detail A illustrates mounting hole dimensions, showing slots for securing the unit.

PDF preview unavailable. Download the PDF instead.

CH-REL30-230VO-+-CH-RS30MAHU

Related Documents

Preview Cooper&Hunter CH-RHP06F9-230VO + CH-R06MOLVWM-230VI Air Conditioner Technical Specifications
Comprehensive technical specifications and key features for the Cooper&Hunter CH-RHP06F9-230VO + CH-R06MOLVWM-230VI air conditioning and heating system, including detailed performance data, dimensions, and certifications.
Preview Cooper&Hunter CH-RES24-230VO + CH-RS24MAHU Split System Air Conditioner Technical Specifications
Comprehensive technical data, key features, and dimensional information for the Cooper&Hunter CH-RES24-230VO + CH-RS24MAHU split system air conditioner, including indoor and outdoor unit specifications and certifications.
Preview Cooper&Hunter CH-R36LCU-230VO + CH-RS36LCAHU Air Conditioner Specifications
Detailed technical specifications, key features, and dimensional data for the Cooper&Hunter CH-R36LCU-230VO + CH-RS36LCAHU air conditioning system, covering both indoor and outdoor unit details.
Preview Cooper&Hunter CH-RES09-230VO + CH-RH09MCT Air Conditioner Specifications
Detailed technical specifications and dimensions for the Cooper&Hunter CH-RES09-230VO + CH-RH09MCT split system air conditioner, including key features and performance data.
Preview Cooper&Hunter CH-REL36-230VO + CH-R36MELVWM-230VI Split System Air Conditioner Technical Specifications
Detailed technical specifications, key features, and dimensional data for the Cooper&Hunter CH-REL36-230VO and CH-R36MELVWM-230VI split system air conditioners, including performance metrics, electrical data, and physical dimensions.
Preview Cooper&Hunter CH-RHP09-230VO + CH-RH09MCT Air Conditioner Specifications and Features
Detailed specifications, key features, and dimensional data for the Cooper&Hunter CH-RHP09-230VO + CH-RH09MCT air conditioning system, including indoor and outdoor unit details, performance metrics, and operating conditions.
Preview Cooper&Hunter Air Conditioner CH-RLS18MIA-230VO/VI Technical Specifications and Installation Guide
Detailed technical specifications, key features, and installation dimensions for Cooper&Hunter CH-RLS18MIA-230VO and CH-RLS18MIA-230VI split system air conditioners, including indoor and outdoor unit details, refrigerant information, and installation notes.
Preview Cooper&Hunter CH-ES24-230VO + CH-M24AHU Split System Air Conditioner Specifications
Detailed specifications and features for the Cooper&Hunter CH-ES24-230VO and CH-M24AHU split system air conditioner, including performance, operational temperatures, and unit dimensions.