Introduction
Thank you for choosing the HBK-RW01 remote control provided by UHPPOTE.
Precaution
For avoidance of damage to the product or injury to people, please carefully read this manual before use and keep it for further reference.
Warnings
- For avoidance of damage to the product, do not expose the product to rain or damp.
- This product is only for indoor use.
- Please use a combination of transmitter and receiver provided by UHPPOTE, as compatibility with other manufacturers' products cannot be guaranteed.
- The product installation shall be conducted by a professional electrician as it requires specialized knowledge. Incorrect operation may damage the product or make it inoperable.
- The transmitter and receiver have been paired with each other in the factory.
- Keep this product away from children under 3 years old to prevent ingestion.
- Install the receiver in a place out of reach of children to prevent electric shock.
- Please do not put the battery in water, fire, or moisture places for avoidance of explosion.
- The battery contains hazardous substance. Return waste batteries to the recycling bin to avoid contamination to the environment.
Features
- Specialized for the access control system and unable to be applied to other fields.
- Support connecting external access control keypad (keypad is excluded).
- Built-in buzzer makes a sound to remind people when the door is locked or unlocked.
- Built-in WiFi module enables remote control of the HBK-RW01 via the free Tuya Smart app.
HBK-RW01 Remote Control Components
The HBK-RW01 unit features:
- Buzzer
- Indicator Light
- Lock Type selector (NO/NC)
- WiFi Pairing button
- RF Pairing button
- Exit Button Port
- Power Port
- Access Keypad Port
- Buzzer indicator
- Operating Mode selector (M/L/T)
- Time Delay selector (0/5/10 seconds)
- Lock Port
The transmitter is powered by 2pcs CR2016 batteries.
Specifications
Receiver
Operating Voltage | 12VDC |
Output Current | 1A |
Operating Environment | Indoor |
Lock Output Port | 1 |
Exit Button Output Port | 1 |
Keypad Connection Port | 1 |
RF Frequency | 433.92MHz |
RF Channel | 1 |
WiFi Standard | 2412-2462MHz |
Transmitter Support | Max. 40 |
DC Encoding Type | Learning Code |
Built-in Buzzer | Yes |
Time Delay | 0/5/10 seconds |
Enclosure Material | ABS Plastic |
Ambient Humidity | 0%RH-95%RH (Non-condensing) |
Ambient Temperature | -22°F to 140°F |
Operating Method | RF Remote and WiFi |
Operating Distance | 164 feet without block |
Operating Mode | Momentary/Toggle/Latched |
Dimensions | 3-37/64"x 2-21/64"x 1-9/64" [91x59x29mm] |
Transmitter
Operating Current | 10mA |
Enclosure Material | ABS Plastic |
Batteries Type | CR2016 (Built-in) |
Transmitting Frequency | 433.92MHz |
Operating Voltage | 6VDC (Powered by 2pcs CR2016 batteries) |
Wiring Demonstration Diagram
1) Connect Fail-Secure Lock
Connect the Access Keypad to the HBK-RW01 unit using the provided wiring. The diagram shows connections for +12V, GND, PUSH, and COM. Select the NO terminal for the lock type. Connect the Exit Button and Fail-secure Lock to the corresponding ports on the HBK-RW01 unit. The Fail-secure Lock has V+, V-, NO, COM, and NC terminals.
2) Connect Fail-Safe Lock
Connect the Access Keypad to the HBK-RW01 unit using the provided wiring. The diagram shows connections for +12V, GND, PUSH, and COM. Select the NC terminal for the lock type. Connect the Exit Button and Fail-safe Lock to the corresponding ports on the HBK-RW01 unit. The Fail-safe Lock has V+, V-, NO, COM, and NC terminals.
Operating Settings
1) Remote Pairing
Tap the RF icon, followed by pressing the button on the transmitter within 20 seconds.
2) Unpairing
Tap and hold the RF icon for 8 seconds. This operation will clear all paired transmitters. Please operate with caution.
3) Lock Type Setting
NO: Fail-Secure Lock
NC: Fail-Safe Lock
Remarks: Incorrect setting will affect the operation of the lock. Please confirm the lock type before setting.
4) Buzzer Setting
ON: Enable. OFF: Disable.
5) Operating Mode Select
- Momentary: Press button A for ON, Release button A for OFF.
- Latched: Press button A for ON, press button B for OFF.
- Toggle: Press button A for ON, press button A again for OFF.
Remarks: Latched mode is only valid when using a transmitter with 2 buttons.
6) Time Delay Setting
Support 0/5/10 seconds time delay. Remarks: Only available when Momentary mode is selected.
7) WiFi Pairing
Please refer to the 'Tuya Smart' APP Operation Guide in this manual.
'Tuya Smart' APP Operation Guide
1. Download Tuya Smart APP
Search 'Tuya Smart' in the Apple App Store for iOS or Google Play for Android.
[App Store icon] for iOS, [Android icon] for Android. A QR code is also provided for downloading the app.
2. Registration and Login
Tap 'Register' on the top-right corner. Input a valid mobile number or email address and tap 'Get Verification Code'. Enter the verification code and set a password, then tap 'Done'.
The app interface shows registration and login screens.
3. WiFi Pairing
Step 1: Power the HBK-RW01 with a 12VDC power adapter.
Step 2: Tap and hold the WiFi icon on the HBK-RW01 for 5 seconds to enter pairing mode.
Step 3: Tap 'Add Device' on the home page of the Tuya app, followed by tapping 'Add' to enter Wi-Fi information.
Step 4: Choose Wi-Fi and enter the password. The Wi-Fi network must be the same as the one your phone is connected to, otherwise, it may cause offline problems. The Tuya Smart app only supports 2.4GHz Wi-Fi communication protocol and cannot support 5GHz.
Step 5: The Tuya Smart app will search for nearby devices and connect to the HBK-RW01. The app interface shows '1 device(s) being added'.
Step 6: Name the added device. The app interface shows '1 device(s) added successfully' and then displays the device control screen with options for Power, Timer, and Settings.
FCC WARNING
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC's RF Exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. Use only the supplied antenna.