ATORCH S1 Smart Socket Programmable Instruction Manual
This document provides comprehensive instructions for the ATORCH S1 Smart Socket, covering its features, operation, safety protections, and specifications.
Overview
This equipment is designed for smart on-off control, safety protection, programmable control, Internet of Things (IoT) data transmission, and wireless control. It allows for cumulative power measurement, electricity bill calculation, and detailed parameter monitoring, including current, voltage, power, and frequency.
(Note: Product optimizations and updates may occur, and differences in the user manual will not be notified separately. Your understanding is appreciated.)
Product Type and Attributes
This product is available in Bluetooth version, smart WiFi version, and smart WiFi curve version. Please refer to the user manual and purchase for specific details.
This user manual is applicable to various socket types, including CN, US, EU, FR, UK, AU, BR, and JP plugs.
Illustrated plug types: [EU plug], [US plug], [FR plug], [UK plug], [AU plug], [JP plug], [BR plug] (Optional).
Key Operation Method and Interface Introduction
The device features a digital display and control buttons. Key elements include:
- Function title bar: Displays parameters such as Active power (P=U*I*cosΦ), Voltage (U), Current (I), and Power Factor (CosΦ).
- Time and online icon: Shows running time when not connected to the Internet, and the calendar when connected.
- Power supply indicator: A light indicating normal power supply.
- Buttons:
- Power Button: Long press to switch ON/OFF mode; Short press to switch interface back.
- M/OK Button: Short press to add; Long press to add continuously; Long press to enter the set background interface; Short press to enter or confirm settings.
- Output socket interface: Supports various plug types (e.g., CN/EU/UK/US/FR/AU/BR/JP).
- Internal CPU temperature display: Shows the device's internal CPU temperature.
- Bluetooth indicator: (For Bluetooth version only) Indicates Bluetooth status.
Interface Navigation and Value Setting
Switching Function Interfaces and Setting Measurement Values:
Connect the power supply as shown. Short press the [+] or [-] buttons to cycle forward or backward through various function display interfaces. Long press the [M] button to enter the system background settings interface. On the front-end interface, a short press of the [M] button will cause the corresponding number to flash. Adjust the value using the [+] / [-] buttons. During flashing, you can continue to short press the [M] button to switch digits and adjust subsequent numbers. When flashing stops, the system will auto-save and display "OK", or a long press of the [M] button will save immediately. Long pressing the [+] / [-] keys in normal times will cycle left and right to switch between several switch modes such as "ON, OFF, and AUTO".
Introduction to Operation:
Long press the [M] button on the front-end interface to enter the back-end settings interface. Then, short press the [+] / [-] buttons to select the desired settings column up and down. Press the [M] button to enter the parameter adjustment interface, and short press the [+] / [-] buttons to adjust parameters. Short press or long press the [M] button again to return to the previous menu. When in the back-end interface, you can also long press the [M] button to quickly return to the front-end function measurement interface.
System Settings (⚙️)
- 01. Language (?): Long press to select language or adjust parameters.
- 02. Display Brightness (?): Short press up/down to select or adjust.
- 03. Standby Brightness (?): Long press continuously to adjust.
- 04. Enter Standby Time (⏰): Short press to enter column or confirm exit.
- 26. Exit (?): Long press to confirm parameters and exit.
Safety Protection Functions
Overvoltage, Overcurrent, and Undervoltage Protection: When a set threshold is reached, an alarm interface will pop up. If the relay type is used, the output will be turned off.
Standby Screen: If set to simple measurement, it enters the measurement interface mode with large numbers when the standby time is reached.
Clear Accumulated Data: Press the [+] button to this column, and "OK" will appear to clear accumulated electricity bill data to zero.
WiFi Settings Reset: If you have changed your WiFi network account password, reset this column to reconfigure the network.
Restore Factory Settings: Short press the [M] key to this column and then long press the [+] key for 3 seconds to reset all data to factory values.
Smart Power-off Protection Settings
Category A: For Electric Vehicles or Full Power Failure of Mobile Phones
Short press the [+] button to go to the security protection page. Short press the [M] key. The voltage hundred digits of the overvoltage automatic power-off bar will flash. Adjust the value using [+] / [-] buttons. Short press [M] again to adjust tens digits. Continue this process for over-current power. Long press [M] to save or wait for the system to auto-save. The set protection threshold can be increased by 5-10% for normal use. If input voltage or current exceeds the threshold, the system will instantly cut off power, prompt with a horn, and display an alarm. The product remains powered off until the user releases the danger by pressing a key or remote control. This feature is inspired by scenarios where users forget to turn off appliances, leading to significant energy waste.
Category B: To Avoid Forgetting to Turn Off Devices
Short press the [+] button to go to the smart power-off type B page and select "on". Observe and record the minimum power value of the connected device when it is powered on. Then, subtract 5-25W from this value to set the power threshold. When the system detects that the current power value is greater than the set threshold, it assumes the device is powered on. The system starts counting down for a set duration. If the user has left home and forgotten to turn off the device, this feature automatically cuts off power, preventing prolonged, unnecessary energy consumption and potential risks.
When power is automatically disconnected, the system will beep several times and display a red power-off interface. If any key signal, remote control signal, or mobile APP signal is detected, the system can reactivate and start another round of smart power-off.
Timing Power Supply Settings
Short press the [+] button to go to the timing power supply page. Set the expected charging time for the device, then press the [+] button to enter automatic mode. The system will power on and count down to the set time. When the time is reached, the system automatically cuts off power output, emitting a beep and displaying a red cut-off interface.
This feature can be used for intermittent power supply to fish ponds, household fish tanks, electric fans (for natural wind effect), or exhaust fans to save electricity. It allows setting opening or closing times according to different situations, providing intermittent power supply to save power and reduce costs.
Difference Between Programming Timing Switches
- Timing power supply page: The power supply will be disconnected after the countdown operation ends according to the time set by the user.
- Cycle timing switch: According to the different switch duration set by the user, the countdown is turned off-on-off automatic cycle power supply.
- Countdown switch page: According to the different switch duration set by the user, a countdown is turned on and then turned off.
Electrical Parameters
Function | S1 Bluetooth socket | S1 smart WiFi socket | S1 WiFi Calendar Energy Statistics socket |
---|---|---|---|
Model number | S1B | S1BW | S1BWP |
Test voltage | AC85-265V / 50-60Hz | ||
Test current | 0-10A max 16A | ||
Test power | Max 3680W | ||
Power range | 0-99999Kwh | ||
Measurement accuracy | ±1% | ||
Power factor | 0-1.00PF | ||
Product size | 133X76X73mm | ||
Operating temperature | -10°C ~ +60°C | ||
Curve function | None | Voltage current power curve | Support voltage, current, and power curve display |
Mobile control | E-test APP | Tuya or smart life APP | |
Firmware upgrade | Not support | WiFi remote networking firmware upgrade | |
Power-off memory | Support | ||
Other functions | None | Get Internet time, calendar and weather data display. |
APP Software and Download Address
APP software and download address: http://www.atorch.cn (Please refer to the official website for more details).
Safety Warning
The input of this product involves strong electricity. Do not touch metal parts with electricity during use. Please pay close attention to safety.
Warranty Card
Warranty Record
This product is covered by a 6-month warranty from the date of purchase, covering manufacturing defects. (Please refer to the warranty terms for details).
Model | Date of Purchase | Warranty Period | Warranty Date |
---|---|---|---|
[Model Number] | [Date] | 6 Months | [Date] |
(Note: The warranty does not cover damage caused by misuse, accidents, or unauthorized repairs.)
Execution Standard: GB/T 12116-2012
Certificate
Certificate of Conformity
Date of manufacture: [Date]
Inspector: 1-01
Model: S1BWP
Serial Number: 023-62923281
Website: http://atorch.cn
Standard: GB/T 12116-2012