Franke Trendline Plus 70
Installation Manual
Important Safety Information
[Warning] Before proceeding with installation, please read the Recommendations and Suggestions provided in the User Manual. Ensure you read the safety instructions contained within the operating manual before installing the appliance.
The installation process requires careful attention to safety guidelines. It is recommended that installation is performed by qualified personnel. Ensure proper ventilation and electrical connections are made according to local regulations.
Safety icons used in this manual include: [Warning] (triangle with exclamation mark), [Home Installation] (house symbol), [Recycling] (recycling symbol), [Electrical] (electrical plug symbol), [Drill] (drill bit symbol), [Screwdriver] (screwdriver symbol), [Wrench] (wrench symbol), [Latch] (latch symbol), [OK] (checkmark symbol indicating correct procedure), and symbols indicating the number of people required for safe installation (e.g., [Two people recommended]).
Parts and Components
The following parts and hardware are included for installation:
- Screws:
- L: 8x (4.2x44.4mm)
- M1: 6x (2.9x9.5mm)
- P1: 4x (2.9x9.5mm)
- P3: 2x (2.9x7.5mm)
- Other Components:
- I: 8x
- M: 2x
- O
- T1, T2, T3
- O1
- O3
- P (Filter/Grille)
- N1 (Inner Chimney Section)
- N2 (Outer Chimney Section)
- W (Fan Units)
[Warning] [Incorrect installation - one person] [Correct installation - two people]
Technical Specifications and Dimensions
Installation Clearances:
- Minimum 650 mm above electric hob [Flame Symbol]
- Minimum 550 mm above gas hob [Electric Symbol]
Ducting Options:
- Option 1: 1x flexible duct, available in Ø 120 mm or Ø 150 mm [Optional Accessory]
- Option 2: 2x flexible ducts, available in Ø 120 mm or Ø 150 mm [Optional Accessory]
Main Hood Dimensions:
- Width: 698 mm
- Depth: 350 mm
- Main Body Height: 319 mm
- Chimney Width: 200 mm
- Chimney Depth: 126 mm
- Chimney Section Height: 330 mm + 330 mm
- Other dimensions: 101 mm, 81 mm, 42 mm, 230 mm
- Maximum installation height (electric hob): 530 mm
- Minimum installation height (electric hob): 365 mm
- Maximum installation height (gas hob): 650 mm
- Minimum installation height (gas hob): 455 mm
Installation Instructions
Step 1: [Home Installation] [Recycling] [Electrical] Position the hood above the hob.
Step 2: [Home Installation] [Recycling] [Electrical] Mark and drill mounting holes on the wall or cabinet. Use a drill bit of Ø 8 mm. Attach the mounting brackets (N1) using screws (e.g., L, 4x Ø 8 mm screws). Drill holes for the hood body. Secure the hood body using screws L (2x) and I (2x). Ensure a 5 mm gap. [OK]
Step 3: [Home Installation] [Recycling] [Electrical] Insert the hood into the mounting frame, engaging the [Latch] mechanism (Z).
Step 4: [Home Installation] [Recycling] Secure the hood from the side using screws (L, 2x).
Step 5: [Home Installation] [Recycling] [Electrical] Mark and drill holes for mounting the hood to the cabinet/wall. Spacing is 440 mm, 100 mm from the top edge. Use a drill bit of Ø 8 mm. Secure using screws L (2x) and I (2x).
Step 6: [Home Installation] [Recycling] Secure the hood using screws (L, 2x).
Step 7: [Home Installation] [Recycling] Attach component O1 using screws M1 (4x).
Step 8: [Home Installation] [Recycling] Attach mounting plates M using screws L (4x).
Step 9: [Home Installation] Connect flexible ducting (Ø 150 mm and Ø 120 mm) to the hood outlet and the wall/chimney.
Step 10: [Home Installation] [Recycling] Attach the inner chimney section (N1), rotating it into place.
Step 11: [Home Installation] [Recycling] Secure the inner chimney section (N1) using screws P1 (4x).
Step 12: [Home Installation] [Recycling] Attach the outer chimney section (N2) to the inner section (N1).
Step 13: Describe air intake/outtake configuration.
Step 14: [Home Installation] [Recycling] Assemble adapter components T1, T2, T3 with O3 using P3 (2x).
Step 15: Connect ducting to the assembled adapter.
Step 16: [Home Installation] [Recycling] Attach chimney section N1.
Step 17: [Home Installation] [Recycling] Secure chimney section N1 with screws P1 (4x).
Step 18: [Home Installation] [Recycling] Attach outer chimney section N2 to N1.
Step 19: [Home Installation] [Recycling] Secure the hood body to the cabinet from the side using screws M1 (2x).
Step 20: [Recycling] Insert the filter/grille (P) and secure it with screws M1 (2x).
Step 21: [Home Installation] [Recycling] Detail showing a connection and the use of the [Latch] mechanism (Z).
Step 22: [Home Installation] [Recycling] Insert filters and secure them using the [Latch] mechanism (Z). Tighten components using a [Wrench].
Step 23: [Home Installation] [Recycling] Connect Fan Units (W) to ducting. Arrows indicate airflow direction. Tighten components using a [Wrench]. [Optional Accessory]