Product Environmental Profile

M22 Complete device with Enclosure

Product Information

Representative product: M22-PVS/KC11/IY (Y7-216523)

Product Category: Switches

Description of the product: Eaton Moeller series M22 Complete device with enclosure is designed to establish and cut off the supply of an electrical circuit.

The PEP concerns following product offerings from Eaton Moeller series M22 Complete device with enclosure as mentioned below:

Standard Contacts with 500 V / 6 A:

Flat rear contacts with 250 V / 4 A:

Functional unit: 'Establish, support and interrupt the rated current 6A and rated voltage 500V AC, with rated making capacity of 6A and rated current in continuous operation 10A for an enclosure installation, in the Industrial application areas, according to the appropriate use scenario, and for the reference service life of the product of 20 years.'

Company Information

EATON INDUSTRIES GMB

Kompetenzzentrum Baederstrasse, Holzhausen, Germany, 56357

Email: productstewardship-es@eaton.com

Constituent Materials

Reference product mass: 2.70E-01 kg (With packaging)

Category PEP Material Material constituent Mass (kg) % Contribution
PlasticsPolycarbonate1.27E-0147.0%
PlasticsPolyamide 6.6 GF303.29E-0212.2%
OtherCardboard2.99E-0211.1%
MetalsStainless steel1.91E-027.1%
PlasticsPolyamide 661.83E-026.8%
OtherPaper1.80E-026.7%
OtherWood9.72E-033.6%
MetalsSteel5.70E-032.1%
PlasticsPolybutylene terephthalate-GF502.81E-031.0%
PlasticsPolyamide 62.63E-031.0%
MetalsBrass2.09E-030.8%
MetalsBronze7.77E-040.3%
PlasticsLow density Polyethylene5.02E-040.2%
OtherLabel5.00E-040.2%
MetalsSilver1.03E-04<0.1%
Total2.70E-01100.0%

Substance Assessment

The representative product is compliant with the EU-RoHS Directive (2011/65/EU) and the product doesn't contain any substance listed as Substance-of-Very-High-Concern (SVHC) on the Candidate List of the EU-REACH Regulation (1907/2006/EC).

Additional Environmental Information

Manufacturing

The reference product is assembled at an Eaton plant in Holzhausen, Germany holding management system certifications according to ISO 14001 standards.

Distribution

Eaton is committed to minimizing weight and volume of product and packaging with focus to optimize transport efficiency.

Installation

The installation process does not require any energy consumption and there is no waste other than the obsolete product packaging generated during this step.

Use

The product requires energy consumption during operation.

End of life

The recyclability rate of the overall product is 23.9% if it is properly dismantled prior to shredding. The rate is calculated based on “WEEE recyclability and recoverability calculation method” (version V1, 20 Sep. 2008 presented to the French Agency for Environment and Energy Management: ADEME).

Lifecycle Phases and System Modelling

The calculation of the environmental impacts is the result of the Product's Life Cycle Analysis in accordance with ISO 14040/44, covering the entire lifecycle, i.e., "Cradle-to-Grave" including the following life cycle phases: production, distribution, installation, use and end of life.

System modelling was carried out using the commercial LCA software EIME v6.3.0.1-4 with database version CODDE-2024-04 - updated on 2024-06-04

Indicators Set: PEF EF 3.1 (Compliance: PEP ed.4, EN15804+A2) v2.0

Manufacturing Phase

The product is assembled as well as packed at EATON INDUSTRIES GMB Kompetenzzentrum Baederstrasse, Holzhausen, Germany plant. Energy model used: Germany

Distribution Phase

Distribution of the product in its packaging from the Eaton's last logistics platform to the installation place in Europe is considered as per PCR rules.

Installation Phase

Product is installed in Europe. Installation of product and treatment of packaging waste are considered in this phase. There is no energy consumption for reference product. Energy model used: Europe

Use Phase

Reference lifetime: 20 Years

Usage profile: The product has power loss of 0.11 W at full load condition. For non-continuous operation considering 30% of the loading rate and 30% of the use time rate, total losses are 0.52 kWh over the 20 years. Product do not require any maintenance/replacement during useful life. non-continuous operation is considered as per PSR-0005 section 3.15.2.1. Energy model used: Europe

End of life Phase

Product disposed with WEEE guidelines. Energy model used: Europe

Module-D

Module D is calculated according to PCR-ed4-EN-2021 09 06 based on the materials recycled and the modelled end-of-life scenario. It expresses the net benefits and loads beyond the boundaries of the system and are not to be included in the life cycle totals.

Environmental Impact Indicators (Mandatory)

Mandatory environmental impact indicators Units Sum A1-A3 Manufacturing A4 Distribution A5 Installation B6* Operational energy use C1-C4 End of life D - Benefits and loads beyond the system boundaries
Climate change - total (GWP)kg CO2 eq.2.15E+001.28E+006.43E-021.42E-015.09E-011.57E-01-8.55E-02
Climate change - fossil fuels (GWP-f)kg CO2 eq.2.12E+001.34E+006.43E-024.94E-025.09E-011.57E-01-1.55E-01
Climate change - biogenics (GWP-b)kg CO2 eq.3.35E-02-6.08E-020.00E+009.30E-029.38E-043.42E-046.94E-02
Climate change - land use and land use transformation (GWP-lu)kg CO2 eq.1.76E-041.76E-040.00E+000.00E+000.00E+001.12E-080.00E+00
Ozone depletion (ODP)kg eq. CFC-118.05E-086.78E-089.87E-114.38E-092.47E-095.74E-09-3.06E-08
Acidification (AP)mole of H+ eq.9.83E-035.72E-034.08E-042.42E-042.61E-038.53E-04-1.01E-03
Freshwater eutrophication (EP-fw)kg P eq.3.34E-051.74E-052.41E-085.47E-071.34E-061.41E-05-1.01E-06
Marine aquatic eutrophication (EP-m)kg of N eq.2.00E-031.19E-031.91E-046.95E-053.18E-042.29E-04-1.39E-04
Mandatory environmental impact indicators Units Sum A1-A3 Manufacturing A4 Distribution A5 Installation B6* Operational energy use C1-C4 End of life D - Benefits and loads beyond the system boundaries
Terrestrial eutrophication (EP-t)mole of N eq.2.14E-021.12E-022.10E-035.39E-045.11E-032.48E-03-1.40E-03
Photochemical ozone formation (POCP)kg of NMVOC eq.5.69E-033.39E-035.29E-041.41E-041.00E-036.32E-04-4.69E-04
Depletion of abiotic resources - elements (ADPe)kg eq. Sb1.55E-041.55E-042.53E-097.91E-091.80E-073.94E-07-6.53E-05
Depletion of abiotic resources - fossil fuels (ADP-f)MJ4.93E+012.92E+018.98E-015.68E-011.29E+015.80E+00-2.65E+00
Water scarcity (WDP)m3 of eq. deprivation worldwide8.77E-017.72E-012.44E-043.23E-023.90E-023.31E-02-2.12E-01

Inventory Flow Indicators (Mandatory)

Inventory flow indicators Units Sum A1-A3 Manufacturing A4 Distribution A5 Installation B6* Operational energy use C1-C4 End of life D - Benefits and loads beyond the system boundaries
Use of renewable primary energy, excluding renewable primary energy resources used as raw materialsMJ5.72E+001.63E+001.20E-035.99E-013.40E+008.96E-027.04E-02
Use of renewable primary energy resources used as raw materialsMJ1.16E+001.16E+000.00E+000.00E+000.00E+000.00E+00-8.28E-01
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials)MJ6.88E+002.79E+001.20E-035.99E-013.40E+008.96E-02-7.58E-01
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materialsMJ4.38E+012.36E+018.98E-015.68E-011.29E+015.80E+00-2.62E+00
Use of non-renewable primary energy resources used as raw materialsMJ5.55E+005.55E+000.00E+000.00E+000.00E+000.00E+00-2.59E-02
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials)MJ4.93E+012.92E+018.98E-015.68E-011.29E+015.80E+00-2.65E+00
Use of secondary materialskg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Use of renewable secondary fuelsMJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Use of non-renewable secondary fuelsMJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Net use of fresh waterm32.07E-021.80E-025.69E-069.07E-049.17E-048.03E-04-4.95E-03
Hazardous waste disposed ofkg2.32E+002.03E+000.00E+002.83E-032.23E-022.66E-01-1.01E+00
Non-hazardous waste disposed ofkg2.03E+006.11E-012.26E-031.86E-028.60E-021.31E+00-4.76E-02
Radioactive waste disposed ofkg2.74E-042.39E-041.61E-062.36E-061.97E-051.20E-05-2.43E-05
Components for re-usekg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Materials for recyclingkg8.79E-021.74E-020.00E+004.80E-020.00E+002.25E-020.00E+00
Materials for energy recoverykg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00

Inventory Flow Indicators (Optional)

Inventory flow indicators Units Sum A1-A3 Manufacturing A4 Distribution A5 Installation B6* Operational energy use C1-C4 End of life D - Benefits and loads beyond the system boundaries
Exported energyMJ by energy vector1.69E-030.00E+000.00E+001.69E-030.00E+000.00E+000.00E+00
Biogenic carbon content of the productkg of C.0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Biogenic carbon content of the associated packagingkg of C.2.79E-022.79E-020.00E+000.00E+000.00E+000.00E+000.00E+00
Optional Environmental impact indicators Units Sum A1-A3 Manufacturing A4 Distribution A5 Installation B6* Operational energy use C1-C4 End of life D - Benefits and loads beyond the system boundaries
Emission of fine particlesincidence of diseases9.65E-086.55E-083.31E-091.36E-092.10E-085.31E-09-2.16E-08
Ionizing radiation, human healthkBq of U235 eq.1.95E+011.59E+001.57E-041.71E+017.32E-012.88E-02-8.14E-01
Ecotoxicity, fresh waterCTUe3.88E+023.84E+024.22E-026.09E-019.62E-012.34E+00-1.29E+00
Human toxicity, cancer effectsCTUh2.60E-072.57E-071.13E-123.64E-096.41E-111.30E-10-1.32E-07
Human toxicity, non-cancer effectsCTUh4.34E-083.94E-082.19E-111.44E-101.53E-092.30E-09-6.65E-09
Impacts related to land use/soil quality-5.50E-015.08E-010.00E+001.17E-041.41E-022.81E-020.00E+00
Total use of primary energy during the life cycleMJ5.62E+013.20E+018.99E-011.17E+001.63E+015.89E+00-3.40E+00

Factors for Use Phase

Multiplying Factors for Use Phase for homogenous products:

Part Number Product Description Equipment heat dissipation, current-dependent (W) Use Phase Extrapolation Factors
Y7-216523 (Reference)M22-PVS/KC11/IY (Reference)0.11W1.00
Y7-187799M22-PV/CKC11/IY0.11W1.00
Y7-216524M22-PV/KC02/IY0.11W1.00
Y7-197629M22-PV/KC03/IY0.11W1.00
Y7-216525M22-PV/KC11/IY0.11W1.00
Y7-110939M22-PV-2KC01-IY1-BVP0.11W1.00
Y7-199352M22-PV30/FK02/FIY10.11W1.00
Y7-199348M22-PV30/FK11/FIY10.11W1.00
Y7-199354M22-PVL30/FK02/RG/FIY10.11W1.00
Y7-199350M22-PVL30/FK11/RG/FIY10.11W1.00
Y7-199355M22-PVLT30/FK02/RG/FIY10.11W1.00
Y7-199351M22-PVLT30/FK11/RG/FIY10.11W1.00
Y7-199353M22-PVT30/FK02/FIY10.11W1.00
Y7-199349M22-PVT30/FK11/FIY10.11W1.00

Factors for Lifecycle Phases

Factors for Manufacturing, Distribution, Installation, End-of-Life, and Module-D Phase:

Part Number Product Description Phases GWP (kg CO2 eq.) GWP-f (kg CO2 eq.) GWPb (kg CO2 eq.) GWPlu (kg CO2 eq.) ODP (kg CFC-11 eq.) AP (mol H+ eq.) EP-fw (kg P eq.) EPm (kg N eq.) EP-t (mol N eq.) POCP (kg NMVOC eq.) ADPe (kg Sb eq.) ADPf (MJ) WDP (m3 eq.)
Y7-216523 (Reference)M22-PVS/KC11/IY (Reference)All Phases except Use Phase1.00
Y7-187799M22-PV/CKC11/IYAll Phases except Use Phase1.00
Y7-216524M22-PV/KC02/IYAll Phases except Use Phase1.00
Y7-197629M22-PV/KC03/IYAll Phases except Use Phase1.00
Y7-216525M22-PV/KC11/IYAll Phases except Use Phase1.00
Y7-110939M22-PV-2KC01-IY1-BVPAll Phases except Use Phase1.00
Y7-199352M22-PV30/FK02/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199348M22-PV30/FK11/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199354M22-PVL30/FK02/RG/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199350M22-PVL30/FK11/RG/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199355M22-PVLT30/FK02/RG/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199351M22-PVLT30/FK11/RG/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199353M22-PVT30/FK02/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06
Y7-199349M22-PVT30/FK11/FIY1Manufacturing0.770.781.100.770.671.101.970.740.780.820.460.781.00
Distribution0.850.851.001.000.850.850.850.850.850.850.850.850.85
Installation1.161.301.091.001.041.181.371.271.241.211.081.251.03
End of Life0.570.574.392.180.840.763.190.640.680.633.610.431.03
Module D0.410.691.041.000.521.570.760.860.850.920.410.771.06

Disclaimer and Verification

Disclaimer

This Product Environmental Profile and its content is based on information available to us. It refers to the product at the date of issue. We make no express or implied representations or warranties with respect to the information contained herein.

Registration NumberEATO-00331-V01.01-EN
Verifier accreditation NumberVH56
Date of issue05-2025
Drafting rulesPCR-ed4-EN-2021 09 06
Supplemented byPSR-0005-ed3.1-EN-2023 12 08
Information and reference documentswww.pep-ecopassport.org
Validity period5 years

Independent verification of the declaration and data, in compliance with ISO 14025: 2006

Internal: X

External:

The PCR review was conducted by a panel of experts chaired by Julie Orgelet (DDomain)

PEPs are compliant with XP C08-100-1:2016 and EN 50693:2019

The components of the present PEP may not be compared with components from any other program.

Document complies with ISO 14025: 2006 « Environmental labels and declarations. Type III environmental declarations »

The document includes the PEP ecopassport logo [description: PEP ecopassport logo indicating environmental certification].

PDF preview unavailable. Download the PDF instead.

eaton-pushbutton-control-stations-pep-eato-00331-v0101-en Microsoft Word for Microsoft 365

Related Documents

Preview Eaton M22-I Surface Mounting Enclosure: Product Environmental Profile
Detailed Product Environmental Profile (PEP) for Eaton's M22-I Surface Mounting Enclosure (M22 Accessories), covering constituent materials, substance assessment, environmental impacts across its lifecycle, and inventory flow indicators. Includes data for M22-I6-* and related models.
Preview Eaton Moeller M22 Contact Element Product Environmental Profile
Product Environmental Profile for Eaton Moeller M22 Contact Elements, detailing constituent materials, substance assessment, and comprehensive life cycle environmental impact indicators based on ISO 14040/44.
Preview Eaton PKZM0 Motor-Protective Circuit Breaker Product Environmental Profile
Comprehensive Product Environmental Profile (PEP) for Eaton's PKZM0 series motor-protective circuit breakers. Details material composition, substance assessment, and life cycle environmental impacts across manufacturing, distribution, installation, use, and end-of-life phases. Includes mandatory and optional environmental indicators and extrapolation factors for various models.
Preview Eaton M22 Accessory with LED (24V) Product Environmental Profile
This Product Environmental Profile (PEP) for the Eaton M22 Accessory with LED (24V) details its life cycle analysis, environmental impacts, constituent materials, and substance assessment. It is based on ISO 14040/44 standards and provides comprehensive data for environmental comparison.
Preview Eaton CI48-250 Product Environmental Profile and Sustainability Data
Detailed Product Environmental Profile (PEP) for the Eaton CI48-250 CI Distribution Enclosure, covering materials, environmental impacts, and lifecycle analysis. Includes part numbers and sustainability factors.
Preview Eaton NS3 Molded Case Switch: Product Environmental Profile (PEP)
Detailed Product Environmental Profile (PEP) for Eaton's NS3 Molded Case Switch (NS3-600-NA, NS3-400-NA) with integrated short-circuit protection. Covers constituent materials, substance assessment, manufacturing, distribution, installation, use, end-of-life impacts, and environmental indicators.
Preview Eaton Fireman's Switch SOL30X Safety First for PV Systems
Eaton's SOL30X Safety First fireman's switches provide essential DC isolation for photovoltaic systems, enhancing firefighter safety and optimizing inverter performance according to VDE-AR-E 2100-712 standards.
Preview Eaton RMQ Termékkatalógus: Működtető- és Jelzőkészülékek
Fedezze fel az Eaton RMQ-Titan, RMQ kompakt, RMQ16, FAK, SL4, SL7 sorozatú működtető- és jelzőkészülékek teljes katalógusát. Részletes információk nyomógombokról, jelzőoszlopokról, vezérlőelemekről és tartozékokról.