Eaton Moeller M22 Contact Element

Product Environmental Profile

Product Overview

Representative Product

M22-CK20 (Y7-107898)

Product Category

Other Equipment - Passive and Non-Continuous Operation

Description of the Product

Eaton Moeller series M22 contact elements are vital for industrial control and automation. They open or close electrical circuits to control machinery, integrate into safety circuits for emergency stops, and pair with indicator lights to provide status feedback, enhancing system reliability and safety.

Homogeneous Environmental Families Covered

  • Y7-107898: M22-CK20
  • Y7-107899: M22-CK02
  • Y7-107940: M22-CK11
  • Y7-216385: M22-CK01
  • Y7-262510: M22-CK01D
  • Y7-216384: M22-CK10
  • Y7-216387: M22-CKC01
  • Y7-216386: M22-CKC10
  • Y7-216378: M22-K01
  • Y7-262165: M22-K01D
  • Y7-216379: M22-K01-GVP
  • Y7-150643: M22-K01PV6
  • Y7-216376: M22-K10
  • Y7-216377: M22-K10-GVP
  • Y7-110835: M22-K10P
  • Y7-216382: M22-KC01
  • Y7-216383: M22-KC01-GVP
  • Y7-216380: M22-KC10
  • Y7-216381: M22-KC10-GVP

Functional Unit

Switch on and off electrical power supply of the control unit with an electrical and/or mechanical control during 20 years of lifetime.

Company Information

EATON INDUSTRIES GMB

Kompetenzzentrum Baederstrasse, Holzhausen, Germany, 56357

Email: productstewardship-es@eaton.com

Constituent Materials

Reference product mass: 3.33E-02 kg (With packaging)

CategoryPEP MaterialMaterial constituentMass (kg)% Contribution
MetalsCopperCopper9.96E-0329.9%
MetalsSteel Wire RodSteel Wire Rod9.68E-0329.1%
PlasticsPolyamide 66 GF30Polyamide 66 GF308.39E-0325.2%
OthersCardboardCardboard1.68E-035.0%
PlasticsPolyamide 6Polyamide 61.51E-034.5%
MetalsBronzeBronze8.60E-042.6%
PlasticsLow Density PolyethyleneLow Density Polyethylene5.02E-041.5%
OthersWoodWood5.00E-041.5%
MetalsSilverSilver1.82E-040.5%
OthersLabelLabel2.50E-050.1%
Total3.33E-02100.00%

Substance Assessment

The representative product is compliant with the EU-RoHS Directive (2011/65/EU) and the product doesn't contain any substance listed as Substance-of-Very-High-Concern (SVHC) on the Candidate List of the EU-REACH Regulation (1907/2006/EC).

Additional Environmental Information

Manufacturing

The reference product is assembled at an Eaton plant in Holzhausen, Germany holding management system certifications according to ISO 14001 standards.

Distribution

Eaton is committed to minimizing weight and volume of product and packaging with focus to optimize transport efficiency.

Installation

The installation process does not require any energy consumption and there is no waste other than the obsolete product packaging generated during this step.

Use

The product requires energy consumption during operation.

End of life

The recyclability rate of the overall product is 48.4% if it is properly dismantled prior to shredding. The rate is calculated based on "WEEE recyclability and recoverability calculation method" (version V1, 20 Sep. 2008 presented to the French Agency for Environment and Energy Management: ADEME).

Environmental Impacts: Mandatory Indicators

The calculation of the environmental impacts is the result of the Product's Life Cycle Analysis in accordance with ISO 14040/44, covering the entire lifecycle, i.e., "Cradle-to-Grave" including the following life cycle phases: production, distribution, installation, use and end of life.

System Modelling

System modelling was carried out using the commercial LCA software EIME v6.2.5-4 with database version CODDE-2024-04 - updated on 2024-06-04. Indicators Set: PEF EF 3.1 (Compliance: PEP ed.4, EN15804+A2) v2.0.

Phase Descriptions

Manufacturing Phase

The product is assembled as well as packed at EATON INDUSTRIES GMB Kompetenzzentrum Baederstrasse, Holzhausen, Germany plant. Energy model used: Germany

Distribution Phase

Distribution of the product in its packaging from the Eaton's last logistics platform to the installation place in Europe is considered as per PCR rules.

Installation Phase

Product is installed in Europe. Installation of product and treatment of packaging waste are considered in this phase. There is no energy consumption for reference product. Energy model used: Europe

Use Phase

Reference lifetime: 20 Years. Usage profile: The product has power loss of 0.05 W at full load condition. For non-continuous operation considering 30% of the loading rate and 30% of the use time rate, total losses are 0.23652 kWh over the 20 years. Product do not require any maintenance/replacement during useful life. Non-continuous operation is considered as per PSR-0005 section 3.15.2.1. Energy model used: Europe

End of life Phase

Product disposed with WEEE guidelines. Energy model used: Europe

Module-D

Module D is calculated according to PCR-ed4-EN-2021 09 06 based on the materials recycled and the modelled end-of-life scenario. It expresses the net benefits and loads beyond the boundaries of the system and are not to be included in the life cycle totals.

Mandatory Environmental Impact Indicators Summary

Mandatory environmental impact indicatorsUnitsSumA1-A3 ManufacturingA4 DistributionA5 InstallationB6 Operational energy useC1-C4 End of lifeD - Benefits and loads beyond the system boundaries
Climate change - total (GWP)kg CO2 eq.3.64E-012.27E-017.93E-036.20E-038.34E-023.90E-02-4.57E-02
Climate change - fossil fuels (GWP-f)kg CO2 eq.3.56E-012.25E-017.93E-032.65E-038.32E-023.77E-02-4.67E-02
Climate change - biogenics (GWP-b)kg CO2 eq.7.47E-032.47E-030.00E+003.54E-031.53E-041.30E-031.02E-03
Climate change - land use and land use transformation (GWP-lu)kg CO2 eq.3.49E-081.13E-080.00E+000.00E+000.00E+002.36E-080.00E+00
Ozone depletion (ODP)kg eq. CFC-111.69E-081.50E-081.22E-113.40E-114.04E-101.37E-09-5.69E-09
Acidification (AP)mole of H+ eq.4.14E-033.38E-035.03E-057.63E-064.27E-042.73E-04-1.15E-03
Freshwater eutrophication (EP-fw)kg P eq.6.38E-052.15E-052.98E-093.46E-082.19E-074.20E-05-2.24E-07
Marine aquatic eutrophication (EP-m)kg of N eq.3.59E-042.43E-042.36E-052.90E-065.20E-053.84E-05-3.83E-05
Terrestrial eutrophication (EP-t)mole of N eq.3.74E-032.14E-032.59E-042.34E-058.36E-044.86E-04-4.23E-04
Photochemical ozone formation (POCP)kg of NMVOC eq.1.13E-037.63E-046.52E-055.48E-061.64E-041.32E-04-1.97E-04

Mandatory Environmental Impact Indicators (Continued)

Mandatory environmental impact indicatorsUnitsSumA1-A3 ManufacturingA4 DistributionA5 InstallationB6 Operational energy useC1-C4 End of lifeD - Benefits and loads beyond the system boundaries
Depletion of abiotic resources - elements (ADPe)kg eq. Sb2.55E-042.53E-043.13E-101.11E-102.95E-081.36E-06-1.03E-04
Depletion of abiotic resources - fossil fuels (ADP-f)MJ9.28E+005.16E+001.11E-012.43E-022.10E+001.88E+00-1.20E+00
Water scarcity (WDP)m3 of eq. deprivation worldwide6.17E-015.67E-013.02E-051.79E-046.39E-034.33E-02-2.06E-01

Inventory Flow Indicators: Mandatory

Inventory flow indicatorsUnitsSumA1-A3 ManufacturingA4 DistributionA5 InstallationB6 Operational energy useC1-C4 End of lifeD - Benefits and loads beyond the system boundaries
Use of renewable primary energy, excluding renewable primary energy resources used as raw materialsMJ7.72E-011.73E-011.48E-045.48E-035.57E-013.68E-02-3.44E-02
Use of renewable primary energy resources used as raw materialsMJ1.86E-011.86E-010.00E+000.00E+000.00E+000.00E+00-2.79E-02
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials)MJ9.58E-013.59E-011.48E-045.48E-035.57E-013.68E-02-6.23E-02
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materialsMJ8.98E+004.86E+001.11E-012.43E-022.10E+001.88E+00-1.19E+00
Use of non-renewable primary energy resources used as raw materialsMJ3.04E-013.04E-010.00E+000.00E+000.00E+000.00E+00-9.73E-03
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials)MJ9.28E+005.16E+001.11E-012.43E-022.10E+001.88E+00-1.20E+00
Use of secondary materialskg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Use of renewable secondary fuelsMJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Use of non-renewable secondary fuelsMJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Net use of fresh waterm31.44E-021.32E-027.02E-071.30E-051.50E-041.01E-03-4.80E-03
Hazardous waste disposed ofkg2.40E+002.36E+000.00E+002.37E-043.65E-033.63E-02-9.58E-01
Non-hazardous waste disposed ofkg4.77E-022.43E-022.79E-041.11E-031.41E-027.99E-03-4.02E-03
Radioactive waste disposed ofkg1.70E-051.19E-051.99E-071.61E-073.23E-061.47E-06-3.31E-06
Components for re-usekg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
Materials for recyclingkg3.00E-021.39E-020.00E+001.76E-030.00E+001.43E-020.00E+00
Materials for energy recoverykg1.57E-031.07E-030.00E+005.03E-040.00E+000.00E+000.00E+00
Exported energyMJ by energy vector2.53E-040.00E+000.00E+002.53E-040.00E+000.00E+000.00E+00
Biogenic carbon content of the productkg of C.0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00

Environmental Impacts: Optional Indicators

Optional Environmental impact indicatorsUnitsSumA1-A3 ManufacturingA4 DistributionA5 InstallationB6 Operational energy useC1-C4 End of lifeD - Benefits and loads beyond the system boundaries
Emission of fine particlesincidence of diseases2.58E-082.04E-084.09E-104.66E-113.44E-091.55E-09-7.00E-09
Ionizing radiation, human healthkBq of U235 eq.4.19E+004.07E+001.93E-054.29E-041.20E-014.18E-03-1.67E+00
Ecotoxicity, fresh waterCTUe4.28E+014.13E+015.20E-033.01E-021.57E-011.30E+00-5.11E-01
Human toxicity, cancer effectsCTUh1.17E-081.14E-081.40E-132.05E-101.05E-114.51E-11-3.71E-09
Human toxicity, non-cancer effectsCTUh4.08E-083.72E-082.70E-127.27E-122.50E-103.43E-09-1.43E-08
Impacts related to land use/soil quality-1.85E-015.93E-020.00E+008.04E-062.31E-031.24E-01-1.55E-04
Total use of primary energy during the life cycleMJ1.02E+015.52E+001.11E-012.97E-022.66E+001.92E+00-1.26E+00

*Only B6 (Energy Consumption) are taken into account, the other sub-modules of the use phase (B1, B3-B5, B7) are zero.

Multiplying Factors for Use Phase for homogenous products

Part NumberProduct DescriptionEquipment heat dissipation, current-dependent (W)Use Phase Extrapolation Factors
Y7-107898 (Reference)M22-CK200.051.00
Y7-107899M22-CK020.051.00
Y7-107940M22-CK110.051.00
Y7-216385M22-CK010.112.20
Y7-262510M22-CK01D0.112.20
Y7-216384M22-CK100.112.20
Y7-216387M22-CKC010.112.20
Y7-216386M22-CKC100.112.20
Y7-216378M22-K010.112.20
Y7-262165M22-K01D0.112.20
Y7-216379M22-K01-GVP0.112.20
Y7-150643M22-K01PV60.112.20
Y7-216376M22-K100.112.20
Y7-216377M22-K10-GVP0.112.20
Y7-110835M22-K10P0.112.20
Y7-216382M22-KC010.112.20
Y7-216383M22-KC01-GVP0.112.20
Y7-216380M22-KC100.112.20
Y7-216381M22-KC10-GVP0.112.20

Disclaimer

This Product Environmental Profile and its content are based on information available to us. It refers to the product at the date of issue. We make no express or implied representations or warranties with respect to the information contained herein.

Verification and Compliance

  • Registration Number: EATO-00317-V01.01-EN
  • Verifier accreditation Number: VH56
  • Date of issue: 04-2025
  • Drafting rules: PCR-ed4-EN-2021 09 06
  • Supplemented by: PSR-0005-ed3.1-EN-2023 12 08
  • Information and reference documents: www.pep-ecopassport.org
  • Validity period: 5 years
  • Independent verification: Internal [X], External
  • PCR review conducted by experts chaired by Julie Orgelet (DDomain).
  • PEPs are compliant with XP C08-100-1:2016 and EN 50693:2019.
  • The components of the present PEP may not be compared with components from any other program.
  • Document complies with ISO 14025: 2006 « Environmental labels and declarations. Type III environmental declarations ».

PDF preview unavailable. Download the PDF instead.

eaton-contact-blocks-pep-eato-00317-v0101-en Microsoft Word for Microsoft 365

Related Documents

Preview Eaton M22-I Surface Mounting Enclosure: Product Environmental Profile
Detailed Product Environmental Profile (PEP) for Eaton's M22-I Surface Mounting Enclosure (M22 Accessories), covering constituent materials, substance assessment, environmental impacts across its lifecycle, and inventory flow indicators. Includes data for M22-I6-* and related models.
Preview Eaton M22 Accessory with LED (24V) Product Environmental Profile
This Product Environmental Profile (PEP) for the Eaton M22 Accessory with LED (24V) details its life cycle analysis, environmental impacts, constituent materials, and substance assessment. It is based on ISO 14040/44 standards and provides comprehensive data for environmental comparison.
Preview Eaton M22 Complete Device with Enclosure: Product Environmental Profile
Detailed environmental impact assessment for the Eaton M22 Complete device with enclosure, covering its lifecycle from manufacturing to end-of-life, including constituent materials and substance compliance.
Preview Eaton Fireman's Switch SOL30X Safety First for PV Systems
Eaton's SOL30X Safety First fireman's switches provide essential DC isolation for photovoltaic systems, enhancing firefighter safety and optimizing inverter performance according to VDE-AR-E 2100-712 standards.
Preview Eaton RMQ Termékkatalógus: Működtető- és Jelzőkészülékek
Fedezze fel az Eaton RMQ-Titan, RMQ kompakt, RMQ16, FAK, SL4, SL7 sorozatú működtető- és jelzőkészülékek teljes katalógusát. Részletes információk nyomógombokról, jelzőoszlopokról, vezérlőelemekről és tartozékokról.
Preview Eaton Safety Components: EN ISO 13849-1 and IEC 62061 Safety Characteristics
Comprehensive technical safety characteristics for Eaton industrial control and safety components, detailing B10D, MTTFD, PL, and SIL values as per EN ISO 13849-1 and IEC 62061 standards.
Preview Eaton FBSmV RCCB Add-on Unit: Product Environmental Profile and Life Cycle Assessment
Detailed Product Environmental Profile (PEP) and Life Cycle Assessment (LCA) for Eaton Moeller series xEffect FBSmV RCCB add-on units, covering constituent materials, environmental impacts, and usage factors.
Preview Eaton FBHmV RCCB Add-on Unit: Product Environmental Profile and Life Cycle Assessment
Comprehensive Product Environmental Profile for the Eaton FBHmV RCCB add-on unit. Details include constituent materials, substance assessment, life cycle environmental impacts (GWP, ODP, etc.), and inventory flow indicators, based on ISO 14040/44 standards.