American Standard Commercial Shower System Kits Installation Instructions
Models: 1662.223, 1662.213
Flow Rates: 1.5 gpm & 2.5 gpm
Introduction
Thank you for selecting American Standard, a benchmark of fine quality for over 100 years. To ensure a smooth installation, please read these instructions carefully before beginning. Installation must conform to all local building codes. This product is certified to comply with ANSI A112.18.1.
Recommended Tools & Materials
- Phillips Screwdriver ?
- Pencil ✏️
- Sealing Tape
- Hammer ?
- Adjustable Wrench ?
- Tubing Cutter
- Pipe Wrench ?
- Tape Measure ?
- 6 mm (15/64") Drill Bit
- Torch ?
- Electric Drill ⚡️
Roughing-In Dimensions
To ensure proper positioning in relation to the wall, note the following roughing-in dimensions:
- Finished Wall to Shower Head Center: 4 inches (102 mm)
- Finished Wall to Hand Shower Connection: 5-1/2 inches (140 mm)
- Finished Wall to Tub Outlet: 7 inches (178 mm)
- Height for Head Clearance: 74 inches (1880 mm) from the finished floor.
- Height for Hand Shower Slide Bar: Optional, typically between 65 inches to 78 inches (1651 to 1981 mm) from the finished floor.
- Optional Height for Lower Connections (e.g., Tub Spout): Between 36 inches to 48 inches (914 to 1219 mm) from the finished floor.
- Valve Body Connections: Universal inlets and outlets are 1/2" NOM Copper Sweat or 1/2" NPT.
- Diverter Connections: 1/2" NPT.
Note: Specific model connections like 1660.505 (1/2" NPSM) and 1660.502 (1/2" NPSM) are also indicated in the diagram.
Installation Steps
Step 1: Install the R1211SS Valve Body
Refer to the separate installation instructions (M965661) supplied with the valve body for complete details. When soldering, remove the PLASTER GUARD, CARTRIDGES, and CHECK STOPS. After soldering, flush the valve body, replace cartridges and check stops, and reinstall the plaster guard. Use thread sealant or Teflon tape on threaded connections. Connections are 1/2" NOM Copper Sweat or 1/2" NPT inlets, and 1/2" NOM Copper Sweat or 1/2" NPT tub and shower outlets. A 1/2" sweat plug may be used if the tub outlet is not needed.
Step 2: Install the R422 Two-Way Diverter
Refer to the separate installation instructions (M965673) supplied with the diverter. The reverse side of the body is marked with arrows. Caution: Do not solder near the valve to avoid damaging the seal. Do not seal any outlets. The diverter cannot be used as a stop valve. Use thread sealant or sealing tape on threaded connections. See the roughing-in diagram; the port with the bathtub picture indicates the high flow. The diverter can be installed with the inlet rotated in any position. All connections are 1/2" NPT. Ensure the finished wall is within the side of the PLASTER GUARD for proper positioning. Connect the R422 Two-Way Diverter to the R120SS Valve Body.
Step 3: Make All Concealed Piping Connections
Refer to the roughing-in diagram. Make Hot and Cold supply connections to the Valve BODY (1/2" copper sweat). Make the SHOWER connection from the DIVERTER using the port with the BATH TUB picture (1/2" NPT). Make the connections for the HAND SHOWER (1/2" NPT). For support, use pipe braces secured to wooden braces. Cap off the SHOWER and HAND SHOWER outlets. With the R120SS Valve turned off, turn on water supplies and check for leaks. Finish all wall construction.
Step 4: Install Valve Trim
Refer to the separate installation instructions (M968763) supplied with the valve trim kit. When the wall is tiled, remove the PLASTER GUARD. Remove the plug from the shower pipe.
Step 5: Install Diverter Trim and Handle
When the wall is tiled, remove the PLASTER GUARD. Place the ESCUTCHEON (1) onto the ESCUTCHEON HOLDER (2). Thread the ESCUTCHEON HOLDER (2) onto the DIVERTER VALVE (3) until the ESCUTCHEON (1) is snug against the finished wall. Install the HANDLE SKIRT (4) onto the VALVE STEM (5). Push the DECORATIVE RING (6) onto the LEVER HANDLE (7). Align the LEVER HANDLE (7) and push it onto the HANDLE SKIRT (4). Install the HANDLE SCREW (8) and tighten. Push the INDEX CAP (9) into the LEVER HANDLE (7).
Step 6: Install Wall Supply
Refer to the separate installation instructions (M968637) supplied with the wall supply. The supply to the WALL SUPPLY is 1/2" NPT. Apply sealant or sealing tape to the threads of the 1/2" NPT supply nipple.
Step 7: Install Hand Shower Slide Bar
Refer to the separate installation instructions (M968637) supplied with the shower system kit. Warning: This slide bar is NOT designed to be a grab bar. The height and location of the SLIDE BAR are optional and can be installed to the right or left side of the R120SS Valve. The slide bar is approximately 33-3/8" (848 mm) to 35-3/8" (899 mm) in length.
Step 8: Install Hose and Hand Shower, Test Shower System
Refer to the separate installation instructions (M968637) supplied with the shower system kit. After all hose connections are made, place the HAND SHOWER into the SLIDE BAR. The installation of the SHOWER SYSTEM KIT is now complete. Turn on water supplies and check all functions of the SHOWER SYSTEM KIT. Check for any leaks.
Parts Identification
The following are key components and their model/part numbers:
Valve Bodies & Trims:
- Pressure Balance Temperature/Volume Control Valve: Model R1211SS
- 2-Way Diverter Valve: Model R422
- Colony Soft Shower Trim: Model T675.501
- Heritage Handle Diverter Trim: Model T342.430
- Associated parts include: Cartridge (023529-0070A), Diverter Repair Kit (M964432-0070A), Escutcheon Kits, Handle Kits, etc.
Shower Heads & Arms:
- FloWise™ Shower Head: 1660.710-002
- Shower Head (M953530-0020A)
- Shower Arm and Flange (023560-0020A)
Hand Showers & Slide Bars:
- Fixed Hand Shower: Part Number 1660.505.002
- 3-Function Hand Shower: Part Number 1660.502.002
- 36" Slide Bar: Part Number 1660.236.002
- Hand Shower Holder (M962507-0020A)
- Support Brackets (M962506-0020A)
Other Components:
- Wall Supply: Part Number 8888.037.002
- Metal Hose: Part Number 8888.035.002
- Hose Kit (030782-0020A)
- Check Valve (M962520-0020A)
- 1/2" Sweat Plug (050145-0070A)
Care Instructions
- DO: Simply rinse the product clean with clear water. Dry with a soft cotton flannel cloth.
- DO NOT: Do not clean the product with soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
Customer Support
For toll-free information and answers to your questions, please call:
- USA: 1 (800) 442-1902 (Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST, Saturday 10:00 a.m. to 4:00 p.m. EST)
- Canada: 1-800-387-0369 (Toronto: 1-905-306-1093) (Weekdays 8:00 a.m. to 7:00 p.m. EST)
- Mexico: 01-800-839-1200