Notice to Users
- This manual provides detailed instructions on how to use the product, along with important precautions and relevant matters. Please read the manual thoroughly before using the product to ensure optimal performance.
- Do not use the instrument in flammable or explosive environments.
- Used batteries and discarded instruments should not be disposed of with household waste. Please dispose of them in accordance with national or local laws and regulations.
- If you encounter any quality issues with the instrument or have any questions about its use, you can contact FNIRSI online customer service or the manufacturer. They will address your concerns as quickly as possible.
Product Introduction
The DMC-100 is FNIRSI's latest 10,000-count intelligent clamp digital multimeter, offering a wider measurement range and higher resolution to help you achieve more accurate measurements. It can precisely measure AC/DC voltage, AC/DC current, and is also capable of testing continuity, capacitance, frequency, resistance, diodes, temperature, NCV (Non-Contact Voltage), and live wires. This device is suitable for use in engineering, laboratories, vehicle maintenance, and household electrical repairs across various electronic fields.
The DMC-100 is equipped with a 2.0-inch full-color TFT display with a high resolution of 240*320. The new UI interface design, along with features such as data curves, data storage, and power measurement mode, enrich your user experience, making it easier to read and operate in various scenarios.
Panel Introduction
The FNIRSI DMC-100 features a user-friendly design with clearly labeled components:
- Clamp Head: The primary component for measuring current by clamping around a conductor.
- NCV Probe: Located near the clamp head, used for Non-Contact Voltage detection.
- Clamp Trigger: Lever to open and close the clamp jaws.
- Flashlight Function: Integrated LED flashlight for illumination.
- Screen: A 2.0-inch full-color TFT display showing measurements and interface information.
- Buttons:
- HOLD Button: Used for data hold and switching ranges/options.
- SAVE/MENU Button: Used for saving data, accessing menus, and returning to previous screens.
- MODE Button: Used for switching measurement modes or functions.
- V-A Button: Used for switching between voltage and current measurements, or entering power measurement mode.
- Power On/Off Button: To turn the device on or off.
- Ports:
- Charging/Data Transfer Port (Type-C): For charging the battery and connecting to a computer.
- COM Input: Common terminal for test probes.
- INPUT Terminal: For connecting test probes for voltage, resistance, etc.
- Probe Interfaces: Clearly marked for Black Probe and Red Probe connections.
Performance Specifications
Function | Range | Accuracy |
---|---|---|
DC Voltage | 9.999V/99.99V/999.9V | ±(0.5%+3) |
AC Voltage | 9.999V/99.99V/750.0V | ±(1%+3) |
DC Current | 99.99A/600.0A | ±(2.5%+10) |
AC Current | (Not specified in detail in the provided text) | (Not specified in detail) |
Resistance | 9.999MΩ/999.9KΩ/99.99KΩ/9.999KΩ/999.9Ω | ±(1.5%+3) |
99.99MΩ | ±(1.5%+3) | |
Capacitance | 999.9μF/99.99μF/9.999μF/999.9nF/99.99nF/9.999nF | ±(2.0%+5) |
9.999mF/99.99mF | ±(5.0%+20) | |
Frequency | 9.999MHz/999.9KHz/99.99KHz/9.999KHz/999.99Hz/99.99Hz/9.999Hz | ±(0.1%+2) |
Temperature | (-55~1300°C)/(-67~2372°F) | ±(2.5%+5) |
Diode | ✔️ | (Test) |
Continuity | ✔️ | (Test) |
NCV | ✔️ | (Detection) |
LIVE | ✔️ | (Detection) |
Main Specifications of the Device
Product Model | DMC-100 |
Display Screen | 2.0-inch Color Screen |
Power Supply | 3.7V Lithium Battery |
Charging Specifications | USB Type-C, 5V/1A |
Maximum Jaw Size | 25mm |
Dimensions | 193x74x32mm |
Product Weight | 194g |
Operating Instructions
5.1 Main Interface
The main interface displays key measurement information. Key elements are:
- 1. Measurement Range: Indicates the current selected measurement range (e.g., DC Current).
- 2. Measurement Parameter: Displays the measured value (e.g., 600 A).
- 3. Unit: Shows the unit of measurement (e.g., A for Amperes).
- 4. Minimum Value: Displays the minimum value recorded during the measurement session.
- 5. Maximum Value: Displays the maximum value recorded during the measurement session.
- 6. Range Switching: Short press the [HOLD] and [V-A] buttons to switch between measurement ranges (DC Current, DC Voltage, Resistance, Capacitance, Frequency, and Live/Neutral Line Detection). Short press the [MODE] button to switch between other test functions within the current range (e.g., DC Current/AC Current).
- 7. Data Hold: Long press the [HOLD] button to hold the current test data. When data is held, "HOLD" will be displayed.
- 8. Flashlight: Long press the flashlight button to turn the flashlight on or off. When the flashlight is on, a flashlight icon will be displayed; when it is off, it will not be shown.
- 9. Data Reset: For DC Current measurements only, short press the power button to reset the data. A 'Z' symbol will be displayed when the data is reset.
- 10. Battery Level: When the battery is full, a full battery icon [battery-full] will be displayed. When the battery is low, a low battery icon [battery-low] will be shown. If the battery level becomes critically low, a popup alert will appear, and the device will automatically start a countdown to shut down.
5.2 Waveform Display Interface
Long press the [MODE] button to enter the waveform display interface.
- 1. Measurement Parameter: Displays the current measurement value.
- 2. Unit: Shows the unit of measurement.
- 3. Measurement Range: Indicates the current measurement range.
- 4. Waveform Display: Shows the waveform of measurement data changes.
- 5. Data Saving: Short press the [SAVE/MENU] button to save data. This section can store up to 8 sets of data. For more data, check the historical records in the settings interface.
- 6. Minimum Value: Displays the minimum recorded value.
- 7. Maximum Value: Displays the maximum recorded value.
5.3 Power Measurement Interface
Long press the [V-A] button to enter the power measurement interface. In this mode, AC and DC are automatically recognized.
- 1. Current Data: Displays the measured current.
- 2. Power Calculation: Shows the calculated power (in Watts).
- 3. Voltage Data: Displays the measured voltage.
5.4 Settings Interface
Long press the [SAVE/MENU] button to enter the settings interface.
- 1. Settings Options: Navigate through History Records, System Settings, Factory Reset, and About.
- 2. Specific Settings:
- [History Records]: Short press [SAVE/MENU] to save data during measurements. Up to 30 sets of data can be saved in history records.
- [System Settings]:
- Language: Select between Simplified Chinese / English.
- Brightness: Adjust brightness across 10 levels.
- Temperature Unit: Select between °C / °F.
- Auto Power Off: Configure auto power off for OFF, 5 min, 15 min, or 30 min.
- [Factory Reset]: Restore factory settings.
- [About]: View brand information and version number.
Firmware Upgrade
To upgrade the firmware:
- With the device powered off, press and hold the [HOLD] and [SAVE/MENU] buttons, then press the [Power] button to turn it on. The screen will display “Firmware Upgrade.”
- Connect the device to a computer using a data cable. The computer will detect a "BOOT" disk.
- Copy the "firmware" file or startup image to the detected disk.
- Press the [SAVE/MENU] button to start the upgrade process.
Precautions
- Before using the product, check if the insulation near the casing and interfaces is damaged.
- Hold the probes by the protective grips.
- Do not touch any of the input ports when measuring a circuit.
- Disconnect the test probes from the circuit before changing the measurement range.
- When measuring DC voltages above 36V or AC voltages above 25V, exercise caution to avoid electric shock.
- Select the correct range for measurement to avoid damaging the instrument. The screen will display "OL" when the measurement exceeds the range.
- When the battery level is critically low, a popup will alert you. Charge the battery promptly to avoid affecting measurement performance. Do not use the device while it is charging.
Production Information
For any questions or inquiries, FNIRSI users are encouraged to contact the company. FNIRSI promises to provide satisfactory solutions and offers an additional 6-month warranty for your support. They have also created a community for users to join.
Shenzhen FNIRSI Technology Co., LTD.
Address: West of Building C, Weida Industrial Park, Dalang Street, Longhua District, Shenzhen, Guangdong, China
Tel: 0755-28020752
Web: www.fnirsi.cn
E-mail (Business): business@fnirsi.com
E-mail (Equipment Service): service@fnirsi.com