AstroAI DM200M Digital Multimeter User Manual

Introduction

Thank you for purchasing the AstroAI DM200M 2000 Counts Digital Multimeter. AstroAI digital multimeters are designed to safely and accurately troubleshoot a wide range of automotive and home electrical issues in schools, laboratories, factories, and other areas. This manual provides all safety information, operation instructions, detailed specifications, and maintenance procedures for the meter. This instrument performs AC/DC Voltage, AC/DC Current, Resistance, NCV Detection, Diode, and Continuity Testing. Thank you again for choosing AstroAI. If you have any questions or concerns regarding your product, please contact AstroAI Customer Support at support@astroai.com.

⚠ Please fully read and understand this manual before using this product and keep this manual for future reference.

Important Safety Warnings

To avoid possible electric shock, personal injury, and other safety accidents, always adhere to the following rules:

Warning: Always keep the inside of the meter clean and dry to prevent electrical shock or damage.

Warning: Replace the battery as soon as it gets low. This will help prevent false readings, electrical shocks, and even injuries. Do not discharge the battery by short-circuiting it or reversing its polarity.

Warning: To ensure safe operation and maintenance of the meter, remove the battery when not used for a long time. Doing so will prevent battery leakage and possible damage to the multimeter.

Included in Box

Electrical Symbols

Automatic Power Off Warning
DC (Direct Current) Diode Test
Negative Reading H Data Hold
Fuse Resistance Test
🔴 Continuity Test Earth Ground
~ AC (Alternating Current) Double Insulation
CE Compliance with EU Directives Low Battery
~ AC (Alternating Current) or DC (Direct Current)

Dimensions

Width: 5.59 inches (142 mm)

Height: 2.87 inches (73 mm)

Depth: 1.77 inches (45 mm)

Diagram: Multimeter Components

The AstroAI DM200M Digital Multimeter features the following key components:

Function Buttons

The multimeter is equipped with several function buttons:

Operating Instructions: Measuring DC/AC Voltage

  1. Turn the rotary switch to the DC Voltage (V–) or AC Voltage (V~) setting and choose the appropriate voltage range.
  2. Insert the red test lead into the "VΩmA" terminal and the black test lead into the "COM" terminal.
  3. Connect the test leads to the circuit being tested in parallel. Ensure the red lead connects to the positive side and the black lead to the negative side.
  4. The reading will appear on the screen.

Note: To avoid damaging the meter, do not measure voltages exceeding 600 V DC or 600 V AC. Exercise extra caution when measuring high voltages to prevent electrical shocks or personal injury. Before use, test a known voltage to confirm the meter is functioning normally.

Operating Instructions: Measuring DC/AC Current

  1. Turn the rotary switch to the current setting (A– or A~) and choose the appropriate current range.
  2. Insert the red test lead into the "VΩmA" terminal for lower currents (mA) or the "10A" terminal for higher currents (up to 10A), and the black test lead into the "COM" terminal.
  3. Press the "FUNC" Button if necessary to select between DC/AC current measurement depending on the setting.
  4. Disconnect the power supply of the circuit being tested. Connect the meter in series to the circuit being tested. Then, turn on the circuit's power supply.
  5. The reading will be displayed on the screen.

Note: To avoid damaging the meter or equipment, check the fuse before performing measurements and ensure that the measured current does not exceed the rated maximum current. Be sure to insert the test leads into the correct terminal. When measuring high currents, the continuous measuring time should not exceed 15 seconds.

Operating Instructions: Measuring Resistance

  1. Turn the rotary switch to the desired resistance setting (Ω) and choose the appropriate range.
  2. Insert the red test lead into the "VΩmA" terminal and the black test lead into the "COM" terminal.
  3. Connect the probes of the test leads to both ends of the resistor or circuit that needs to be measured.
  4. The reading will be displayed on the screen.

Warning: Safely disconnect the power supply and discharge high-voltage capacitors before measuring resistors on a circuit board. Failure to do so may damage the meter and increase the risk of electrical shock.

Note: When measuring resistors on a circuit board, the reading may be affected by other electrical paths between the test leads.

Operating Instructions: Continuity Test

  1. Turn the rotary switch to the Continuity Test (🔴 symbol) setting.
  2. Insert the red test lead into the "VΩmA" terminal and the black test lead into the "COM" terminal.
  3. Connect the probes of the test leads to both ends of the circuit or resistor that needs to be measured.
  4. If the resistance value of the measured resistor or circuit is less than 50 Ω, the buzzer will beep. The screen will display the resistance value.

Warning: Safely disconnect the power supply and discharge high-voltage capacitors before measuring the meter's continuity. Failure to do so may damage the meter and increase the risk of electrical shock.

Note: When measuring the meter's continuity, the reading may be affected by other electrical paths between the test leads.

Operating Instructions: Diode Test

  1. Turn the rotary switch to the Diode Test (📅 symbol) setting.
  2. Insert the red test lead into the "VΩmA" terminal and the black test lead into the "COM" terminal.
  3. Connect the red test lead to the positive end of the diode and the black test lead to the negative end.
  4. The reading (forward voltage drop) will be displayed on the screen.

Warning: Safely disconnect the power supply and discharge high-voltage capacitors before performing diode tests on the circuit board. Failure to do so may damage the meter and increase the risk of electrical shock.

Note: When performing a diode test on the circuit board, the reading may be affected by other electrical paths between the test leads.

Operating Instructions: Non-Contact Voltage Test (NCV)

  1. Turn the rotary switch to the "NCV" setting.
  2. Gradually move the meter's NCV probe closer to the detected object.
  3. When the meter senses a weak EMF signal, the "--L" character will appear on the screen, and the buzzer will emit a slow beep.
  4. When the meter senses a strong EMF signal, the "--H" character will appear on the screen, and the buzzer will beep rapidly.

Maintenance: Auto Power Off

  1. If the meter is on and not in use, it will shut off automatically after 15 minutes to preserve battery life. Press any button or turn the rotary switch to turn it back on.
  2. To cancel the automatic power off function, press and hold the HOLD Button, then turn on the meter. To resume the automatic power off function, turn off the meter and then turn it back on.

Maintenance: Cleaning the Meter

If the terminals are dusty or wet, incorrect measurements may occur. Please clean the meter as follows:

  1. Turn off the meter and remove the test leads.
  2. Flip the meter over and shake out any dust that has built up in the terminals. Wipe the case with a damp cloth or mild detergent. Do not use abrasives or solvents. Wipe the contacts in each terminal with a clean cotton and alcohol.

Warning: Always keep the inside of the meter clean and dry to prevent electrical shock or damage.

Maintenance: Battery Replacement

  1. Turn off the meter and remove the test leads.
  2. Remove the screws on the battery cover with a screwdriver, then remove the cover.
  3. Remove the old battery and replace it with a new battery of the same specification. Pay attention to the polarity markings (+ and –) for each battery in their compartments.
  4. Put the battery cover back in its original position and secure it with its screws.

Warning: Replace the battery as soon as it gets low. This will help prevent false readings, electrical shocks, and even injuries. Do not discharge the battery by short-circuiting it or reversing its polarity.

Warning: To ensure safe operation and maintenance of the meter, remove the battery when not used for a long time. Doing so will prevent battery leakage and possible damage to the multimeter.

Maintenance: Fuse Replacement

  1. Turn off the meter and remove the test leads.
  2. Remove the screws on the meter's back cover, then remove the back cover.
  3. Remove the blown fuses and replace them with new fuses of the same specification. Ensure the fuse is loaded into the fuse holder and clamped tightly.
  4. Put the back cover back on and secure it with the removed screws.
  5. Fuse specifications:
    • Fuse 1: F250 mA/250 V, 5 x 20 mm
    • Fuse 2: F10 A/250 V, 5 x 20 mm

Warning: Please use fuses of the same or specified rating to prevent electrical shock, injury, or damage to the meter.

Specifications

Max Display 1999
Pollution Level 2
Range Selection Manual
Power 1 x 9 V 6F22 Battery
Altitude 6562 ft (<2000 m)
Sample Speed 3 Times Per Second
Overload Indication "OL" Displayed
Low Battery Indication ● Displayed
Environmental Conditions CAT III 600 V
Input Polarity Indication "-" Automatically Displayed
Fuse Protection mA: F250 mA/250 V Fuse
10 A: F10 A/250 V Fuse
Temperature and Humidity 32~104 °F (0~40 °C); (<80% RH, <10 °C RH)
Storage Temperature and Humidity 14~140 °F (-10~60 °C); (<70% RH, take out battery)
Temperature Coefficient 0.1 x Accuracy/°C, <18 °C or >28 °C (<64 °F or > 82 °F)
Maximum voltage between the measuring terminals and the ground 600 V

Detailed Specifications

Accuracy Note: Accuracy applies within one year after calibration.

Operating Conditions: The ambient temperature is between 64.4 °F to 82.4°F (18 °C to 28 ° C), and the relative humidity is less than or equal to 80%.

Accuracy: ± (% rdg + dgts) (rdg for reading and dgts for digits)

DC Voltage

Range Resolution Accuracy
200 mV 0.1 mV ±(1.0% rdg + 5 dgts)
2 V 0.001 V
20 V 0.01 V
200 V 0.1 V
600 V 1 V

Overload Protection: 600 V; Max Input Voltage: 600 V

Resistance

Range Resolution Accuracy
200 Ω 0.1 Ω ±(1.2% rdg + 5 dgts)
2 kΩ 0.001 kΩ
20 kΩ 0.01 kΩ
200 kΩ 0.1 kΩ
2 MΩ 0.001 MΩ
20 MΩ 0.01 MΩ

Overload Protection: 250 V

AC Voltage

Range Resolution Accuracy
200 V 0.1 V ±(1.2% rdg + 5 dgts)
600 V 1 V

Overload Protection: 600 V; Max Input Voltage: 600 V/40~400 Hz

DC/AC Current

Range Resolution Accuracy
20 mA 0.01 mA ±(1.5% rdg + 5 dgts)
200 mA 0.1 mA ±(1.5% rdg + 5 dgts)
10 A 0.01 A ±(2.0% rdg + 5 dgts)

Overload Protection: mA: F250 mA/250 V fuse A: F10 A/250 V
Max Input Current: 250 mA; 10 A
AC Current Frequency Range: 40 Hz ~ 400 Hz; Response: True RMS
When measuring high currents, the continuous measuring time does NOT exceed 15 seconds.

Continuity

Condition Result
If the value of the measured resistance or circuit is less than 50 Ω, the buzzer will beep. Open circuit voltage is about 2 V.
Overload Protection: 250 V

Diode

Function Result
Displays the approximate diode forward voltage value. The reverse DC voltage is about 2.0 V.
Overload Protection: 250 V

Recycling

You may dispose of the product when its service life has ended. Please recycle the recyclable parts according to local guidelines.

Warranty Period

3-Year Limited Warranty from AstroAI.

Each AstroAI DM200M Digital Multimeter will be free from defects in material and workmanship.

This warranty does not cover fuses, disposable batteries and damage from neglect, misuse, contamination, alterations, accidents, or abnormal conditions of operation or handling, including overvoltage failures caused by use outside the multimeter's specified rating, or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable.

If this product is defective, please contact AstroAI Customer Support at support@astroai.com.

Models: DM200M, DM200M, ABMUDM200MRD

PDF preview unavailable. Download the PDF instead.

ABMUDM200MRD-EN-v1 ?version=1720715406 Adobe PDF library 15.00 Adobe Illustrator 25.2 (Windows)

Related Documents

Preview AstroAI M6KOR True RMS 6000 Count Digital Multimeter User Manual
Explore the features and operation of the AstroAI M6KOR True RMS 6000 Count Digital Multimeter. This manual provides detailed instructions for AC/DC voltage, current, resistance, capacitance, frequency, temperature testing, and more.
Preview AstroAI M4KOR True RMS Digital Multimeter User Manual
Comprehensive user manual for the AstroAI M4KOR True RMS Digital Multimeter, covering its features, functions, operation, maintenance, and specifications.
Preview AstroAI AM33B Digital Multimeter User Manual
Comprehensive user manual for the AstroAI AM33B 2000 Counts Digital Multimeter, covering operation, safety, specifications, and maintenance for AC/DC voltage, current, resistance, continuity, and diode testing.
Preview AstroAI AM33B Digital Multimeter User Manual - Operation, Safety, and Specifications
User manual for the AstroAI AM33B 2000 Counts Digital Multimeter, detailing its features, operating instructions, safety precautions, maintenance, specifications, and warranty information.
Preview AstroAI AM33D Digital Multimeter User Manual - 2000 Counts
Comprehensive user manual for the AstroAI AM33D Digital Multimeter (2000 Counts), providing detailed instructions, safety precautions, specifications, and maintenance guidance for electrical measurements including AC/DC voltage, current, resistance, continuity, and diode testing.
Preview AstroAI CM2KOR Digital Clamp Meter User Manual
Comprehensive user manual for the AstroAI CM2KOR Digital Clamp Meter, covering introduction, warnings, included items, electrical symbols, meter diagram, button functions, auto power off, usage instructions, maintenance, battery replacement, specifications, disposal, and warranty.
Preview AstroAI MUS10KRD Smart Digital Multimeter User Manual
User manual for the AstroAI MUS10KRD Smart Digital Multimeter. This guide provides comprehensive information on its features, operation, safety precautions, and specifications for accurate AC/DC voltage, current, resistance, continuity, frequency, and temperature measurements, including NCV and Live Wire detection.
Preview AstroAI DM130B Digital Multimeter User Manual
Comprehensive user guide for the AstroAI DM130B digital multimeter, detailing safety precautions, features, specifications, and operating instructions for accurate electrical measurements.