AstroAI CM2KOR Digital Clamp Meter User Manual

Introduction

Thank you for purchasing the True RMS 2000 Counts Clamp Meter from AstroAI. This meter is designed to be safely and accurately used by professionals and DIYers alike. This manual provides all safety information, operation instructions, specifications, and maintenance information for the meter. The instrument performs AC Current, AC/DC Voltage, Resistance, Audible Continuity Testing, Diode Testing, NCV Detection, and Capacitance Testing.

For any questions or concerns regarding your product, please contact AstroAI at support@astroai.com.

! Fully read and understand this manual before use and keep it for future reference.

Warning

To avoid electric shocks or personal injury, and possible damage to the meter or to the equipment being tested, please adhere to the following rules:

Included in Box

Electrical Symbols

AC (Alternating Current)Ω Resistance
DC (Direct Current)))) Continuity Test
AC and DCDiode Test
CapacitanceLow Battery
CurrentV Voltage
Warning! Dangerous Voltage may be present
Earth GroundNCV Non-Contact Voltage Setting

Dimensions

The meter has the following dimensions:

A diagram shows the meter with these dimensions indicated.

Meter Diagram

The meter components are labeled as follows:

  1. NCV Detector
  2. Transformer Jaws
  3. Flashlight
  4. DATA HOLD Button
  5. Trigger
  6. Rotary Switch
  7. FUNC Button
  8. Flashlight Button
  9. Backlight Button
  10. MAX/MIN Button
  11. Display
  12. INPUT Terminal
  13. COM Terminal
  14. Test Leads
  15. Storage Bag

Button Functions

FUNC

Use the rotary switch to select a function. Use the "FUNC” Button to select a specific function if there are multiple functions in one rotary setting. For example: Switching between AC and DC voltage tests; choosing between diode, resistance, and continuity tests. NOTE: Pay special attention to the selected setting before performing any tests.

Data Hold Button (H)

Press this button while performing a test to hold (freeze) the reading for easy recording. The screen will display when the hold function is activated. Press the button again to cancel the data hold.

Flashlight Button

Press this button to turn the flashlight on/off.

MAX/MIN Button

Press this button to turn on the MAX/MIN hold function, and press it again to view the recorded maximum value and minimum value, respectively. Press and hold the button for more than two seconds to exit this function.

Backlight Button (*)

Press this button to turn the screen's backlight on/off.

Input and COM Terminals

Auto Power Off

If the Meter is not in operation for 15 minutes, it will turn off automatically. To turn it on again, simply rotate the range switch or press any button.

How to Use This Meter

The Meter is very sensitive. It will be affected by nearby magnetic fields. Without touching any objects, there may be a reading jumping on the screen when it is turned on. This is a normal occurrence for a digital meter and it does not affect the measurement results.

NOTE:

I. Measuring AC Current

  1. Turn the rotary dial to the “200/400 A~" or "2/20 A~" setting. The screen will display "AC" indicating that the measurement function is AC current.
  2. Press the trigger to open the transformer jaws, clamp the conductor to be tested, slowly releasing the trigger until the clamp head is completely closed. Ensure the conductor to be tested is in the center of the clamp head. Errors will occur if the conductor is not placed in the center of the clamp head.
  3. After the reading stabilizes, record it from the LCD screen.
  4. Turn the rotary switch to the OFF position to turn off the Meter.

II. Measuring AC/DC Voltage

  1. Insert the red test lead into the Input terminal and the black test lead into the COM terminal.
  2. Turn the rotary dial to the continuity test. Then, touch the red and black test leads together to ensure they function. The buzzer will beep and the indicator light will come on if the test leads are normal.
  3. Turn the rotary dial to the “V~” setting. The screen will display "AC" indicating that the measurement function is AC voltage.
  4. Turn the rotary dial to the "DC" setting. The screen will display "V=" indicating that the measurement function is DC voltage.
  5. Connect the meter in parallel to the circuit being tested.

NOTE: If the reading is negative when measuring DC voltage, it means that the positive and negative poles of the test leads are reversed, please change the test leads.

  1. After the reading stabilizes, record the reading from the LCD screen.
  2. Turn the rotary switch to the OFF position to turn off the Meter.

Voltage Notes

III. Measuring Resistance

  1. Insert the red test lead into the Input terminal and the black test lead into the COM terminal.
  2. Turn the rotary dial to the continuity test. Then, touch the red and black test leads together to ensure they function. The buzzer will beep and the indicator light will come on if the test leads are normal.
  3. Turn the rotary dial to the "ΩH” setting. The screen will display "Ω" indicating that the measurement function is resistance.
  4. Connect the test leads to both ends of the circuit or resistor being tested (connect the leads to the resistance under test in parallel).
  5. After the reading stabilizes, record the reading from the LCD screen.
  6. Turn the rotary switch to the OFF position to turn off the Meter.

Resistance Notes

IV. Measuring Capacitance

  1. Insert the red test lead into the Input terminal and the black test lead into the COM terminal.
  2. Turn the rotary dial to the continuity test. Then, touch the red and black test leads together to ensure they function. The buzzer will beep and the indicator light will turn on if the test leads are normal.
  3. Turn the rotary dial to the “Ωㅓ” setting. Press the “FUNC” button to switch to capacitance test. The screen will display “n F” indicating that the measurement function is capacitance.
  4. Connect the test leads to both ends of the circuit or resistor being tested (connect the leads to the resistance under test in parallel).
  5. After the reading stabilizes, record the reading from the LCD screen.
  6. Turn the rotary switch to the OFF position to turn off the Meter.

Capacitance Tips

Capacitance Notes

V. Continuity Test

  1. Insert the red test lead into the Input terminal and the black test lead into the COM terminal.
  2. Turn the rotary dial to the “╋)” setting. The screen will display "” indicating that the measurement function is continuity. Then, touch the red and black test leads together to ensure they function. The buzzer will beep if the test leads are normal.
  3. Connect the test leads to both ends of the circuit or resistor being tested (parallel). If the resistance of the circuit or resistor being tested is less than 50 Ω, the buzzer will emit a beep and the measured resistance value will be displayed on the LCD display.
  4. If the circuit or resistor being tested is disconnected, or the resistance value is greater than 50 Ω, the LCD screen will display “OL”.
  5. Turn the rotary switch to the OFF position to turn off the Meter.

VI. Diode Test

  1. Insert the red test lead into the Input terminal and the black test lead into the COM terminal.
  2. Turn the rotary dial to the continuity test. Then, touch the red and black test leads together to ensure they function. The buzzer will beep and the indicator light will turn on if the test leads are normal.
  3. Turn the rotary dial to the “╋)” setting. Press the “FUNC” button to switch to the diode test. The screen will display "→" indicating that the measurement function is diode.
  4. Connect the red test lead to the anode of the diode being tested and the black test lead to the cathode of the diode.

NOTE: Usually the anode of the diode is the longer end.

  1. The LCD screen will display the approximate voltage drop reading of the diode. If the test leads are connected reversely, “OL” will be displayed on the LCD screen. Please replace the test leads to measure again.
  2. Turn the rotary switch to the OFF position to turn off the Meter.

Diode Test Tips

Polarity Judgment Method

VII. Non-Contact Voltage

  1. Turn the rotary dial to the "NCV/Live" setting. The screen will display "NCV” indicating that the measurement function is non-contact voltage.
  2. Move the NCV detector close to the point to be tested: When the Meter senses a weak AC signal, the green indicator light will be on, the buzzer will emit a slow, audible beep and the screen will display "---L"; When the Meter senses a strong AC signal, the red indicator light will be on, the buzzer will emit a quick beep and the screen will display "---Н”.

NOTE: When the indicator light is on, it means there is voltage, please pay attention to your safety!

  1. Turn the rotary switch to the OFF position to turn off the Meter.

VIII. Live Wire Detection

  1. Insert the red test lead into the INPUT terminal.
  2. Turn the rotary dial to the "NCV/Live" setting. Press the "FUNC” button to switch to live wire detection. The screen will show "Live" indicating that the measurement function is live wire detection.
  3. Touch the point to be measured with the tip of the red test lead: When the indicator light is on, it means that the measured position is a live wire, please pay attention to your safety! A green light may mean that the test lead is not fully connected to the socket. Please test again after confirming that the test lead is fully connected.

NOTE: When the meter senses a weak AC signal, the LCD screen will display "---L”, and the buzzer will emit a slow beep; When the meter senses a strong AC signal, the LCD screen will display "---H", and the buzzer will emit a quick beep.

  1. Turn the rotary switch to the OFF position to turn off the Meter.

Maintenance

Cleaning the Meter

If there is dust or humidity in the terminals, it may produce erroneous measurements. Please clean the Meter as described below:

Battery Replacement

If the low battery sign appears on the LCD display, the battery should be replaced immediately. Remove the screws and open the back case, replace the expended battery with new batteries (Size AAA, 1.5 V x 2).

NOTE: Replace batteries immediately to prevent inaccurate readings due to low power. This also prevents potential safety hazards.

Specifications

FeatureValue
Digital Display2000, 3½
Sampling Speed3 Times/Second
LCD Dimensions35 x 25 mm
Range SelectionAuto
Polarity Indication"-" Automatically Displayed
Overload Indication"OL” Displayed
Low Battery Indication"[low battery symbol]" displayed when battery voltage is lower than normal
Work Environment32°F~104°F (0 °C~40 °C; <80% RH,<10 °C Non-Condensing)
Storage Temperature14 °F~140 °F (-10°C~60 °C; <70% RH, Remove the Battery)
Power2 x 1.5 V AAA Batteries
WeightApproximately 203 g
Dimensions195 x 68 x 29 mm
Safety/ComplianceCAT.III 600 V; Pollution Level: 2; Altitude <2000 m

Detailed Specifications

I. Precision Index

Ambient Temperature :18 °C to 28 °C,

Relative Humidity: ≤ 80%;

Accuracy: ± (%rdg + dgts)

The accuracy is consistent within one year of calibration.

II. DC Voltage

RangeResolutionAccuracy
2 V0.001 V± (0.5% + 5 )
20 V0.01 V
200 V0.1 V
600 V1 V

Input Impedance: 10 MΩ

Overload Protection: 600 V

Maximum Measuring Voltage: 600 V

III. AC Voltage

RangeResolutionAccuracy
2 V0.001 V± (1.0% + 5)
20 V0.01 V
200 V0.1 V
600 V1 V

Input Impedance: 10 MΩ

Overload Protection: 600 V

Maximum Measuring Voltage: 600 V

Frequency Range: 40 Hz ~ 1k Hz

Response: True RMS

IV. AC Current

RangeResolutionAccuracy
2 A0.001 A50~60 Hz: ± (2.5% + 5)
Other: ± (3.0% + 10)
20 A0.01 A
200 A0.1 A
400 A1 A

Frequency Range: 40 Hz ~ 400 Hz

Response: True RMS

V. Resistance

RangeResolutionAccuracy
200 Ω0.1 Ω± (1.0% + 5)
2 kΩ0.001 kΩ
20 kΩ0.01 kΩ
200 kΩ0.1 kΩ
2 MΩ0.001 MΩ
20 MΩ0.01 MΩ

Overload Protection: 250 V

VI. Capacitance

RangeResolutionAccuracy
2 nF0.001 nF± (4.0% + 5)
20 nF0.01 nF
200 nF0.1 nF
2 μF0.001 μF
20 μF0.01 μF
200 μF0.1 μF
2 mF0.001 mF

Overload Protection: 250 V

VII. Continuity Test

The buzzer inside the Meter will beep if the resistance is< 50 Ω.

Open Circuit Voltage: Approximately 1.0 V

Overload Protection: 250 V

VIII. Diode Test

The approximate diode forward voltage value will be displayed

Reverse DC Voltage: Approximately 2.0 V

Overload Protection: 250 V

How to Dispose of the Meter

If, at some point, you intend to dispose of this product, please keep in mind that many of its components consist of valuable materials which can be recycled. Please do not discard it in the garbage bin, but check with your local authorities for recycling facilities in your area.

Warranty Period

3 Year Limited Warranty from AstroAI.

Each AstroAI Digital Clamp Meter will be free from defects in material and workmanship.

This warranty does not cover fuses, disposable batteries and damage from neglect, misuse, contamination, alteration, accident, or abnormal conditions of operation or handling, including overvoltage failures caused by use outside the Multimeter's specified rating, or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable.

If this product is defective, please contact AstroAI Customer Support at support@astroai.com

Models: CM2KOR, CM2KOR Digital Clamp Meter, Digital Clamp Meter, Clamp Meter, Meter

PDF preview unavailable. Download the PDF instead.

ASICM2K0R-EN-v2 ?version=1720715815 Adobe PDF library 15.00 Adobe Illustrator 25.2 (Windows)

Related Documents

Preview AstroAI M4KOR True RMS Digital Multimeter User Manual
Comprehensive user manual for the AstroAI M4KOR True RMS Digital Multimeter, covering its features, functions, operation, maintenance, and specifications.
Preview AstroAI 4000 Count Clamp Multimeter User Manual
Comprehensive user manual for the AstroAI 4000 Count Clamp Multimeter, covering safety instructions, operating procedures, specifications, and maintenance for accurate electrical measurements.
Preview AstroAI AM33D Digital Multimeter User Manual - 2000 Counts
Comprehensive user manual for the AstroAI AM33D Digital Multimeter (2000 Counts), providing detailed instructions, safety precautions, specifications, and maintenance guidance for electrical measurements including AC/DC voltage, current, resistance, continuity, and diode testing.
Preview AstroAI MUS10KRD Smart Digital Multimeter User Manual
User manual for the AstroAI MUS10KRD Smart Digital Multimeter. This guide provides comprehensive information on its features, operation, safety precautions, and specifications for accurate AC/DC voltage, current, resistance, continuity, frequency, and temperature measurements, including NCV and Live Wire detection.
Preview Manuel d'utilisation du multimètre numérique AstroAI CM2KOR
Manuel d'utilisation complet pour le multimètre numérique AstroAI CM2KOR, détaillant ses caractéristiques, fonctions, précautions de sécurité et spécifications pour des mesures électriques précises.
Preview AstroAI 6000 Counts Digital Multimeter User Manual
Comprehensive user manual for the AstroAI 6000 Counts Digital Multimeter, covering safety precautions, operation instructions, technical specifications, and maintenance.
Preview AstroAI DM2000 True RMS Digital Multimeter User Manual
User manual for the AstroAI DM2000 True RMS Digital Multimeter, detailing its features, functions, specifications, and safe operating procedures for various electrical measurements.
Preview AstroAI CM2K0R Digital Clamp Meter User Manual
Comprehensive user manual for the AstroAI CM2K0R Digital Clamp Meter, covering features, safety warnings, operating instructions, specifications, and maintenance.