WaterCop Classic Dual Actuator and HW Sensor Dimensional Drawing
This document outlines the specifications and certifications for the WaterCop Classic Dual Actuator and Hardwired (HW) Sensor system.
Product Overview
The WaterCop Classic Dual Actuator is designed for automatic water shut-off systems. All valves are certified to NSF/ANSI 372 for use with potable water.
Enclosure: Polycarbonate
Power: Power Converter with 20' Cord
Controls: Local Controls
Valve: Full Port Brass Ball Valve
Radio Receiver Frequency: 418 MHz
The system includes an auxiliary actuator shown with the valve attached.
Dimensional Specifications
The following table details the dimensions (A, B, C, D, E, F, G, H) and flow rates for different valve sizes and sensor configurations.
Mode | Number of Hardwired Sensors | Valve Size | A | B | C | D | E | F | G | H | Flow GPM |
---|---|---|---|---|---|---|---|---|---|---|---|
WCDACTDUALHW | 1 | - | - | - | - | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - |
WCDACTDUALHW2 | 2 | - | - | - | - | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - |
WCDACTDUALHW | 1 | 1/2 - 14 NPT | 2.60 | 4.78 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW2 | 2 | 1/2 - 14 NPT | 2.60 | 4.78 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW | 1 | 3/4 - 14 NPT | 2.90 | 5.02 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW2 | 2 | 3/4 - 14 NPT | 2.90 | 5.02 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW | 1 | 1" NP | 3.56 | 5.19 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW2 | 2 | 1" NP | 3.56 | 5.19 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW | 1 | 1 1/4 - 11-1/2 NPT | 3.66 | 5.18 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - | |
WCDACTDUALHW2 | 2 | 1 1/4 - 11-1/2 NPT | 3.66 | 5.18 | 0.74 | 3.78 | 4.10 | 5.00 | 4.05 | - |
Drawing Information
Drawing Title: Actuator shown with valve attached
Drawing Number: SUB407
Revision Dates: MJP 07-02-25, CMM 12-19-17, CMM 12-19-17
This print is the property of DynaQuip Controls and shall not be copied, reproduced, loaned, or disposed of directly or indirectly, nor used for any purpose other than that for which it is specifically furnished, except by written permission of DynaQuip Controls.