MILESEEY TP2 PLUS Thermal Imager

Warranty Statement

For complete products manufactured by Mileseey, a two-year warranty is provided from the date of initial purchase, under conditions of normal storage, reasonable use, and maintenance. The warranty period for accessories is three months.

This warranty is non-transferable and does not apply to products damaged due to misuse, negligence, accidents, or abnormal operating conditions. If defects occur, the product must not be used further or repaired privately to prevent further damage. The purchaser must immediately report the product defect to Mileseey; otherwise, this warranty will not apply.

If, upon inspection by Mileseey, the product or accessory is found to be faulty, the user may contact Mileseey's after-sales service department within the warranty period to negotiate repair or replacement.

1.2 Quality Assurance

The quality management system has been certified according to the ISO9001 standard. Mileseey reserves the right to modify or improve any product without prior notice.

Safety Instructions

Warning:

Applicability: Class B digital devices.

1. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

2. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures:

Frequency range of WLAN radio module: 5.15~5.85GHz. Maximum power of WLAN radio module: 13dBm (Only for EU).

Mileseey Technology Co., Ltd. declares that the radio equipment type TP2 PLUS is in compliance with Directive 2014/53/EU, 2011/65/EU.

To comply with RF exposure requirements, a minimum separation distance of 0mm must be maintained between the user's body and the handset, including the antenna.

Caution:

User Notice

3.1 Calibration

To ensure the accuracy of temperature measurements, it is recommended to calibrate the thermal imager annually. This calibration can be performed either by Mileseey or a third-party organization.

3.2 Accuracy

To achieve highly accurate results, wait for 5 minutes after turning on the thermal imager before beginning temperature measurements (this includes switching temperature ranges).

3.3 Documentation Updates

Manuals are updated several times a year, and notices about key product changes are regularly issued. To access the latest manuals and notifications, please visit the Mileseey official website.

3.4 Applicability

This manual applies to all products within a series, meaning some functions described may not be applicable to a specific model within the series.

3.5 Disposal of Electronic Waste

2012/19EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information, see: www.recycle-this.info

2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point.

Component Guide

4.1 Front View

The front view shows the Infrared Imager Lens, Power Button, Digital Imager (TP2 Plus only), and Battery Indicator light.

4.2 Back View

The back view shows the Back Clamp.

Name Function
Back Clamp Flexible, used for clamping the phone

4.3 Side View

The side view shows the USB Interface.

Name Function
USB Interface Charge using a USB cable connected to a power adapter.

Quick Operating Guide

  1. Charging: Use a 5V 2A power adapter and USB cable to charge the device. Please charge the device in room temperature conditions.
  2. Power On: Press and hold the power button to turn on the device.
  3. Locate the Target: Aim the thermal imager at the object of your interest.
  4. Capturing Images: Use the Mobile App on your phone to capture images by pressing the imager button and record videos by pressing the video button.
  5. APP Analysis: Open the accompanying App for the thermal imager, navigate to the gallery, select the picture for secondary analysis, and proceed with the analysis.

APP Description

6.1 App Overview

The "Thermal TP Series" app, for secondary analysis, is compatible with the TP series of wireless thermal imagers. It allows viewing images in five different modes (infrared, visible light, dual-light fusion, picture-in-picture) with the ability to customize and switch between them. The app features capabilities for pseudocolor switching, photography, video recording, and custom temperature analysis with points, lines, and frames.

6.2 App Connectivity

  1. Press and hold the power button to turn on the device and ensure the Bluetooth function of your smartphone is enabled.
  2. Open the "Thermal TP Series" app.
  3. Click on the device you want to connect to.
  4. A pop-up window will prompt: "Thermal TP Series wants to join the wireless network TP2. Cancel or Join?" Click on "Join" to successfully connect (this step is only necessary for iPhone models).

6.3 Introduction of the Main User Interface

The main user interface displays various icons and their functions:

Icon Name Description
< Return Tap to return to the device connection interface.
Model Indication of specific model of the device.
⚙️ Settings Tap to perform operations such as setting the temperature range, network settings, etc., and to view the device's remaining battery life and product information.
➕ ?️ Preset template settings Tap to customize drawing points, lines, frames for temperature analysis, or to delete.
Center, maximum, minimum temperature point setting Tap to set the center point, maximum, minimum temperature point on or off. When these temperature points are activated, their real-time temperature values are displayed in the top left corner of the screen.
?️ Image mode Switching (TP2 Plus only) Supports four modes: infrared, visible light, dual-light fusion, picture-in-picture, with the ability to customize and switch between these modes.
? Color palettes switching Supports several pseudocolor options including Iron Red, White Hot, Black Hot, Rainbow, with the ability for customized switching between these colors.
⚙️ Shutter Tap to activate the shutter for a non-uniformity correction.
? Parameter setting Tap to set the emissivity, ambient temperature, and target distance. Tap to set the temperature unit: Celsius, Kelvin, Fahrenheit. Tap to set the distance unit: meter, feet.
?️ Photo album Tap to view the captured photo and video materials, with support for secondary analysis.
? Photo capturing Tap to capture the image, automatically saving the current screen image to the album.
? Video recording Tap to capture the image, automatically saving the current screen image to the album.

6.4 Setting Interface

Measurement Range: Options for low and high temperature ranges are available; supports automatic switching of temperature ranges.

Cleaning

7.1 Clean the exterior casing, cables, and other components of the thermal imager.

Cleaning Solution Warm water, Mild cleaning solution
Cleaning Tool Soft cloth
Cleaning Steps Dip a soft cloth in the cleaning solution. Wring out the soft cloth to remove excess cleaning solution. Use the soft cloth to clean the components.

Warning:

Avoid applying the solution or similar liquids directly onto the thermal imager, cables, or other components, to prevent damage to the device.

7.2 Clean the infrared imager lens

Cleaning Solution A commercial lens cleaning solution with an isopropyl alcohol concentration of over 30%, or 96% concentration ethanol (C2H5OH).
Cleaning Tool Degreasing Cotton/Cotton Swab
Cleaning Steps Dip a piece of degreasing cotton in a small amount of cleaning solution. Squeeze the degreasing cotton to remove excess cleaning solution. Gently wipe the lens with the degreasing cotton. The cotton should be used only once and not reused.

Warning:

When cleaning the infrared lens, avoid applying excessive force. This could damage the lens's anti-reflective coating.

Technical Parameter

Model TP2 Plus
Thermal Sensor Uncooled Vanadium Oxide
Thermal Resolution 256x192
Pixel Pitch 12μm
Wavelength Range 7.5 ~ 14 μm
Frame Rate 25Hz
Focal Length 3.2mm
Lens Aperture F1.1
Field of View 56°×42°
Type of Focus Fixed
Focal Distance 0.3m~
IFOV 3.75mrad
NETD 40mK
Visible Light Camera (TP2 Plus only) 200w
Color Palettes White Hot/Black Hot/ Rainbow/Rainbow HC/ Iron/Lava/RdGy
Imaging Mode (TP2 Plus only) Infrared, Visible Light, Picture in Picture, Fusion
Remote Access and Control Capable Of Connecting To Smart Devices Via WiFi From A Distance Of Up To 26ft (8m)
Device Compatibility Supports Smartphones with iOS 12.0 Or Higher And Android 9.0 Or Higher.
Clamp Width Minimum 131/Maximum 165mm
Data Capturing Video, Still Image
Picture Format .jpg
Video Format MP4
OTA Supports OTA (Over-The-Air) upgrades.
WiFi IEEE 802.11 a/b/g/n/ac
Temperature Range TP2 PLUS: -20~+150℃, +100~+550℃
TP2: -20~+150℃, +100~+400℃ (Supports Auto Switch)
Accuracy Reading accuracy of ±2% or ±2°C (whichever is greater) @ ambient temperature of -10~50°C.
Temperature Analysis Coldest And Hottest Points, Central Point, And Custom Measurements (Supports 3 Custom Points, 3 Custom Lines, 3 Custom Frames)
Emissivity Setting 0.01-1.00
Connecting Solution USB Type-C
Battery 1050mAh
Charging Time 1.5h
Charging Temperature 0~+40°C (Do Not Charge The Device In High-Temperature Environments Above 40°C Or In Low-Temperature Environments Below 0°C.)
Charging Solution WiFi, USB Type-C
Battery Runtime 2h, with Battery Indicator
Operating Temperature -10~+50°C
Storage Temperature -20~+60°C
Relative Humidity 10%~90% (Non-Condensing)
IP Rating IP54
Drop Rating 2m
Certification CE/FCC/ROHS/TELEC/DGM/TSCA/WEEE
Shock & Vibration 2G (IEC60068-2-6), 25G (IEC60068-2-29)
Dimensions 135.6mm x 41mm x 29.1mm
Net Weight 125g

Contact Information

Mileseey Technology (US) Inc.

Office Add: 17800 CASTLETON ST STE 665 CITY OF INDUSTRY, CA 91748

Manufacturer: Shenzhen Mileseey Technology Co., Ltd.

Add: No.3601 Block A, Tanglang Town Plaza West, Fuguang Community, Taoyuan Street, Nanshan District, Shenzhen, China

Website: www.mileseey.net

Store: www.mileseeytools.com

E-mail: service@mileseey.com

Made in China

MILESEEY has been researching, developing, and manufacturing high-quality optical products, including golf & hunting rangefinders, laser measure devices, and thermal & digital night visions since 2009. With over 12 years of focus on development, research, and manufacturing, Mileseey strives to provide premium-quality products and satisfying customer service to make your life easier and smarter.

Certifications: FC, CE, ROHS, Reach

Recycling Information:

FCC Caution

FCC ID: 2AEOG-TP2PLUS

§ 15.19 Labeling requirements.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

§ 15.21 Information to user.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

§ 15.105 Information to the user.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures:

Body Operation

This device was tested for typical body operations. To comply with RF exposure requirements, a minimum separation distance of 5mm must be maintained between the user's body and the handset, including the antenna. Third-party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided. Use only the supplied or an approved antenna.

Operations in the 5.15-5.25GHz band are restricted to indoor usage only.

Models: 2AEOG-TP2PLUS, 2AEOGTP2PLUS, tp2plus, TP2 PLUS Thermal Imager, TP2 PLUS, TP2 PLUS Imager, Thermal Imager, Imager

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=7528881 福昕高级PDF编辑器打印机 版本 9.5.0.1620

Related Documents

Preview Mileseey TP2 Handheld Wireless Infrared Thermal Imager User Manual
Explore the Mileseey TP2 Handheld Wireless Infrared Thermal Imager with this comprehensive user manual. Learn about its features, operation, safety instructions, and maintenance.
Preview MILESEEY TR256C Thermal Imaging Camera User Guide
Comprehensive user guide for the MILESEEY TR256C Thermal Imaging Camera with Laser Measure & GPS. Learn about product overview, safety instructions, appearance, display icons, settings, specifications, and warranty.
Preview MILESEEY TR10 Handheld Infrared Thermal Imager User Manual
User manual for the MILESEEY TR10 Handheld Infrared Thermal Imager, detailing its features, safety instructions, and operational settings for accurate temperature measurement.
Preview Mileseey Tools Catalog 2025: Measurement Tools & Thermal Imaging
Explore the Mileseey Tools 2025 catalog, featuring advanced laser distance meters, digital tapes, and handheld thermal imaging cameras designed for professionals. Discover innovative features, high precision, and durable solutions for various applications.
Preview Mileseey TR120 Handheld Infrared Thermal Imager User Guide
User guide for the Mileseey TR120 Handheld Infrared Thermal Imager, covering product overview, safety instructions, appearance, display icons, settings, and technical specifications.
Preview MILESEEY TR256 Handheld Infrared Thermal Imager User's Guide
User's guide for the MILESEEY TR256 Handheld Infrared Thermal Imager, detailing its features, operation, safety instructions, and specifications.
Preview MILESEEY TR256B/TR256E Handheld Thermal Camera User Manual
User manual for the MILESEEY TR256B and TR256E handheld thermal cameras, covering safety information, technical specifications, and quick start guide.
Preview Mileseey TNV30 User Manual: Thermal Imaging Night Vision Device
User manual for the Mileseey TNV30, a handheld monocular thermal imaging night vision device. Learn about its features, operation, safety instructions, and specifications.