Oregon Scientific PROJI Projection Clock with Weather Forecast

Model: BAR369P/BAR369PU

Introduction

Thank you for purchasing the Oregon Scientific™ PROJI Projection Clock with Weather Forecast. This device bundles precise time keeping, alarm, temperature, and weather monitoring features into a single tool for home use. Please keep this manual handy for practical step-by-step instructions, technical specifications, and warnings.

Package Contents

  • Main unit
  • Power adapter
  • Remote sensor (THN132N)
  • 2 x AAA batteries for main unit
  • 1 x AA battery for remote sensor

Overview

Front & Top View

1. + Button: Press to increase settings or toggle between channels 1-5 and auto-loop. Press and hold to increase settings rapidly or search for sensors across all channels in idle mode.

2. SNOOZE | LIGHT Button: Press to snooze an alarm or activate the backlight and projection. Press and hold until a beep is heard to activate projection for 5 minutes.

3. Mode Button: Press to toggle between current time, calendar, or alarm 1/2 displays for 5 seconds. Press and hold to enter setting mode.

4. - Button: Press to decrease settings. Press and hold to decrease settings rapidly.

5. Projection lens.

6. Alarm Button: Press to turn alarms on/off. Press and hold to enter alarm setting mode.

Rear View

1. Battery compartment.

2. Projection focus knob: Adjusts projection focus.

3. RESET Button: Press to reset the unit to default settings.

4. / PROJECTION Button: Press to flip projection content 180°. Press and hold to toggle continuous projection on/off.

5. RCC Button: Press to turn on and search for the RCC signal. Press and hold to turn off.

6. Battery compartment cover.

LCD Screen

  1. Time display
  2. Weather forecast display
  3. Outdoor temperature display (Channel 1-5)
  4. Weekday display
  5. Indoor temperature display

Symbol Descriptions:

  • Alarm 1 is on: [Alarm 1 icon]
  • Alarm 2 is on: [Alarm 2 icon]
  • RCC signal received: [RCC signal icon]
  • Outdoor sensor low battery: [Sensor low battery icon]
  • Main unit low battery: [Main unit low battery icon]
  • Receiving sensor signal: [Receiving signal icon]
  • Outdoor sensor auto-loop function is on: [Auto-loop icon]
  • Outdoor sensor channels: [Channel icon]

Projection Display

  1. Time display
  2. Weather forecast display

Remote Sensor (THN132N)

  1. LED status indicator
  2. Wall mount hole
  3. Battery compartment
  4. RESET hole
  5. CHANNEL switch

Note: This package includes a 3-channel sensor. For sensors with up to 5 channels, additional accessory sensors can be purchased. Visit www.oregonscientific.com for more details.

Getting Started

Insert Batteries

  1. Gently push the battery compartment cover downwards to remove it from the main unit.
  2. Insert batteries, matching polarities (+/-).

Note: Replace batteries when the low battery indicator [Low battery icon] appears or when the display is dim.

DC Power

Plug the power cable into the power jack and the power adapter into a suitable power outlet. It is recommended to insert batteries as a backup power source.

Remote Sensor Setup

The main unit can collect data from up to 5 sensors.

  1. Open the battery compartment.
  2. Insert batteries, matching polarities (+/-).
  3. Select a channel then press RESET.
  4. Close the battery door.
  5. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount.

Tip: For accurate readings, place the sensor outdoors at a height of 1.5 m (5 ft), shielded from direct sunlight and wet conditions.

Sensor Data Transmission

To search for a sensor, press and hold the + button. The sensor reception icon indicates the status:

  • [Searching icon]: Searching for sensor(s).
  • [Found icon]: Sensor is found.
  • [Not found icon]: Cannot find sensors.

Tip: Transmission range may vary. Experiment with different locations for best results.

Clock

Clock Reception

The clock synchronizes automatically with a clock signal. Press RCC to turn on and search for the signal. The main unit receives RF clock data with different RCC signals:

Model numberRegionSignal
BAR369PEUDCF
BAR369PUUKMSF

Clock signal reception indicator:

  • [Searching strength icon]: Main unit is searching for clock signal strength.
  • [Searching icon] (flashing): Main unit is searching for clock signal.
  • [No signal icon]: No clock signal.
  • [Strong signal icon]: Strong RCC signal received.
  • [Weak signal icon]: Weak RCC signal received.

Note: Signal reception takes 2-10 minutes. Weak signals may take up to 24 hours.

Set the Clock Manually

  1. Press and hold the Mode button. The screen displays ZONE, and the number flashes.
  2. Press the + or - button, or press and hold them, to adjust the setting. For EU/UK, the time-zone offset sets the clock up to +/- 23 hours from the received clock signal time. For US, time-zone settings include Atlantic (A), Mountain (M), Pacific (P), Central (C), Eastern (E), Newfoundland (N).
  3. Press the Mode button to confirm.
  4. Press the Mode button again or press and hold +/- to adjust settings for 12/24h format, hour, minute, year, calendar format (month-day/day-month), month, date, temperature unit (°C/°F), language, and daylight saving time (DST) (ON/OFF).
  5. Press the Mode button to confirm each setting.

Notes:

  • Language options: English (ENG), Spanish (SPA), Italian (ITA), French (FRE), German (GER).
  • RCC signal reception is active after each reset or battery replacement.
  • DST is set to OFF when RCC is off or when time/date settings are changed.
  • Press and hold the Mode button while in setting mode to save and exit.

Alarm

Setting/Adjusting Alarm Time

  1. Press and hold the Alarm button.
  2. Press +/- to adjust the hour and minute, then press the Alarm button to confirm.
  3. Press +/- to toggle the weekday alarm ON/OFF, then press the Alarm button to confirm. The alarm rings only on weekdays when set to ON.
  4. Repeat steps 2-4 for alarm 2.

Turn On/Off Alarms

Press the Alarm button to cycle through alarm states: Alarm 1 ON > Alarm 2 ON > Both ON > Both OFF.

Operation

When the alarm rings, the backlight will flash. You can:

  • Press the Alarm button to stop the alarm. It will ring again the next day.
  • Press SNOOZE | LIGHT to snooze. The alarm will ring again after 8 minutes.

Weather Forecast

This product forecasts weather for the next 6 hours within a 19-31 mile (30-50 km) radius.

  • Sunny: ☀️
  • Snowy: ?️
  • Cloudy: ☁️
  • Rainy: ?️

Temperature

The current indoor temperature is displayed in the bottom right corner. Connect up to 5 remote sensors for outdoor temperature readings.

To toggle sensor display, press +/-.

Note: Indoor temperature below -5°C (23.0°F) displays LL.L. Above 50°C (122.0°F) displays HH.H.

To auto-loop between sensors, press +/- repeatedly until the auto-loop icon [Auto-loop icon] appears. Data from each sensor displays for 3 seconds. Press +/- again to turn off auto-loop.

Note: Sensors display in ascending order. Missing sensors are skipped.

Projection

The projector displays time and weather forecast on your ceiling for easy viewing in dark rooms. For optimal results, place the unit 1.5 - 2 m (5 – 6.5 ft) from the ceiling or wall.

  • Press SNOOZE | LIGHT to activate backlight and projection for 5 seconds.
  • Press and hold SNOOZE | LIGHT until a beep to activate projection for 5 minutes.
  • Press / PROJECTION to flip projection 180°.
  • Press and hold / PROJECTION to toggle continuous projection on/off.
  • Adjust focus (1.5 - 2 m) using the focus knob.

Note: Continuous projection is disabled when the unit is not connected to the power adapter.

Precautions

  • Do not subject the unit to excessive force, shock, dust, temperature, or humidity.
  • Do not cover ventilation holes.
  • Do not immerse the unit in water. Dry immediately if liquid is spilled.
  • Do not clean with abrasive or corrosive materials.
  • Do not tamper with internal components; this invalidates the warranty.
  • Use only fresh batteries. Do not mix new and old batteries.
  • Images in this manual may differ from the actual product.
  • Dispose of this product separately for special treatment, not as normal household waste.
  • Placement on certain wood finishes may cause damage; Oregon Scientific is not responsible. Consult furniture manufacturer's care instructions.
  • Contents of this manual may not be reproduced without permission.
  • Do not dispose of old batteries as unsorted municipal waste; collect separately for special treatment.
  • Remove battery safety strip before first use.

Note: Technical specifications and manual contents are subject to change without notice. Features and accessories may not be available in all countries.

Specifications

Main Unit

  • Dimensions (L x W x H): 128 x 26 x 91 mm (5.04 x 1.02 x 3.58 in)
  • Weight: 158g (5.57 oz) without batteries
  • Temperature Range: -5°C to 50°C (23°F to 122°F)
  • Accuracy: 0°C to 40°C: ± 1°C (± 2.0°F); < 0°C and >40°C: ± 2°C (± 4.0°F)
  • Resolution: 0.1°C (0.2°F)
  • Power: 2 x UM-4 (AAA) 1.5 V batteries or 3.6V adapter

Remote Unit (THN132N)

  • Dimensions (L x W x H): 96 x 50 x 22 mm (3.78 x 1.97 x 0.87 in)
  • Weight: 50 g (1.76 oz) without batteries
  • Transmission Range: 30 m (98 ft) unobstructed
  • Temperature Range: -20 °C to 60 °C (-4 °F to 140 °F)
  • Signal Frequency: 433 MHz
  • Power: 1 x UM-3 (AA) 1.5 V battery

About Oregon Scientific

Visit www.oregonscientific.com for more information. For inquiries, contact Customer Services at info@oregonscientific.com.

Oregon Scientific Global Distribution Limited reserves the right to amend this manual without prior notice. In case of inconsistency, the English version prevails.

EU-Declaration of Conformity

Oregon Scientific declares that this PROJI Projection Clock with Weather Forecast (model: BAR369P/BAR369PU) complies with essential requirements and relevant provisions of Directive 1999/5/EC. A copy of the Declaration of Conformity is available upon request.

Countries RTTE Approved Complied: All EU countries, Switzerland CH, and Norway N.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to two conditions: (1) it may not cause harmful interference, and (2) it must accept any interference received, including interference that may cause undesired operation.

Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Note: This equipment complies with FCC limits for Class B digital devices, designed for reasonable protection against harmful interference in residential installations. It generates, uses, and can radiate radio frequency energy. If interference occurs, try reorienting the antenna, increasing separation, connecting to a different circuit, or consulting a dealer/technician. This Class B digital apparatus complies with Canadian ICES-3(B)/NMB-3(B).

Declaration of Conformity

Name: Oregon Scientific, Inc.

Address: 10778 SW Manhasset Drive, Tualatin, Oregon 97062 USA

Telephone No.: 1-800-853-8883

Declare that the product:

  • Product No.: BAR369P/BAR369PU
  • Product Name: PROJI Projection Clock with Weather Forecast
  • Manufacturer: IDT Technology Limited, Block C, 9/F, Kaiser Estate, Phase 1, 41 Man Yue St., Hung Hom, Kowloon, Hong Kong

is in conformity with Part 15 of the FCC Rules. Operation is subject to the conditions: 1) no harmful interference, and 2) acceptance of received interference.

Information for Users

Pursuant to EU Directives 2012/19/EU (WEEE) and 2006/66/EC (Batteries). The barred symbol of the rubbish bin indicates separate collection at the end of the product's life. Batteries must be removed before disposal. Separate collection ensures proper treatment and recycling, preventing negative environmental and health effects.

PDF preview unavailable. Download the PDF instead.

BAR369P Adobe InDesign CS5.5 (7.5) Adobe PDF Library 9.9

Related Documents

Preview Oregon Scientific PRYSMA B Projection Clock with Weather Forecast User Manual
Learn how to set up and use the Oregon Scientific PRYSMA B BAR223P Projection Clock with Weather Forecast. This user manual covers time setting, alarm functions, temperature monitoring, and troubleshooting for the BAR223P and RTHN129 remote sensor.
Preview Oregon Scientific Weather Day & Night User Manual (BAR339DP Series)
Comprehensive user manual for the Oregon Scientific Weather Day & Night clock and weather station, models BAR339DP, BAR339DPA, BAR339DPU, and BAA339DPH. Provides instructions on setup, operation, features like alarm, weather forecast, projection, and troubleshooting.
Preview Oregon Scientific PRYSMAchrome Weather Station BAR292 User Manual
Comprehensive user manual for the Oregon Scientific PRYSMAchrome Weather Station (BAR292/BAR292A), detailing setup, features, troubleshooting, and specifications.
Preview Oregon Scientific RF Projection Clock RM939P RM939PA User Manual
User manual for the Oregon Scientific RF Projection Clock models RM939P and RM939PA, detailing features, setup, operation, and specifications, including compatibility with MSR939/MSR939A motion sensors and VR101/VR101A vibrating wake-up alarms.
Preview Oregon Scientific BAR933HG/BAR936HG Weather Station User Manual
User manual for the Oregon Scientific BAR933HG and BAR936HG Weather Station with Scrolling Message Alerts. Learn how to set up, operate, and troubleshoot your weather station, including features like temperature and humidity monitoring, weather forecasting, barometric pressure readings, and UV index measurement.
Preview Oregon Scientific Weather Day & Night BAR339DP User Manual
User manual for the Oregon Scientific Weather Day & Night clock, including setup, features, specifications, and precautions for models BAR339DP, BAR339DPA, BAR339DPU, and BAA339DPH.
Preview Oregon Scientific AWS899 Colour Weather Station with Digital Photo Frame User Manual
User manual for the Oregon Scientific AWS899 Colour Weather Station with Digital Photo Frame. This guide provides instructions on setup, operation, features like weather forecasting, temperature and humidity monitoring, and photo display.
Preview Oregon Scientific RM383P RF Projection Clock User Manual
User manual for the Oregon Scientific RM383P RF Projection Clock with Lighting Effect. Includes setup, operation, and safety precautions.