DOOR CONTROL WIRING MATRIX
LZR-FLATSCAN SW LZR-FLATSCAN 3D SW
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certified for pedestrian doors, IDA-certified for doors/gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer's recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g. ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.
Certifications: AAADM, ANSI, DASMA, IDA
Product Visuals
LZR-FLATSCAN SW: Features a sleek, low-profile design with a dark, matte finish. The sensor unit appears to be a single, integrated component.
LZR-FLATSCAN 3D SW: Similar to the SW model, this unit also has a dark, matte finish and a low-profile design. It appears to be slightly more complex or perhaps has a different sensor array visible.
Control Harness Wiring Matrix
Control Harness: 20.5433
Product | R (POWER 1) | Bk (01: N.O.) | Bl (01: N.C.) | Br (01: COM) | G (02: REACTIVATION 2) | W (02: ACT (COM)) | Gy (03: VPB 3) | Gy | P | P | MONITORING 4 |
---|---|---|---|---|---|---|---|---|---|---|---|
Besam ETIK 5 | 30.5558 | 15/17 | 16/18 | TB4-29 | TB4-26 | Logic Module | 4 | 3 | TB3-20 | TB3-21 | Not supported. |
Besam MP/CUP | 30.5558 | 5 | 4 | Logic Module | 4 | 3 | 1 | 1 | Not supported. | ||
Besam PowerSwing/EXB | 30.5558 | TB4-29 | TB4-26 | Logic Module | 4 | 3 | TB3-20 | TB3-21 | Not supported. | ||
Besam SM | 30.5558 | TB1-7 | 3 | Logic Module | 12 | 13 | 3 | 1 | Not supported. | ||
Assa Abloy SW 100/200, EXU-SA 3 | 24V+ | GND | EXU-SA1 | Logic Module | 12 | 13 | 3 | 1 | Refer to BEA product User's Guide and OEM manual. | ||
DITEC HA9 6 CONDOR | 30.5558 | DMS O | COMMON N | EXU-SA 1 and 2 (N.C.) | V and W | COM 16 | ACTIVATE 17 | Not supported. | |||
DCU DC700 Access Auto. ES500 Quad Systems ES500 | 30.5558 | CN6 GREEN | AUX CN7 (AF = 2) | CN6 BLACK | CN2 #3 | CN2 #2 | Not supported. | ||||
Detex BS1000S/UDC100 | 30.5558 | 5 | 1 | J2-3 and 1 | 1 | Logic Module | 2 | 2 | Not supported. | ||
Dor-O-Matic | 30.5558 | PURPLE | GRAY | Logic Module | GRAY | YELLOW | Not supported. | ||||
Dorma 400/700 | 30.5558 | SWING | GND | APPR and GND | GND | TRIGGER | Not supported. | ||||
Dorma ED 100/250 7 | 1 | 3 | 15 | 3 | 11 (N.C.) | 3 | 42 | Refer to BEA product User's Guide and OEM manual. | |||
Gyrotech/Nabco Magnum | 30.5558 | 3 VIOLET | 5 RED | Logic Module | 5 RED | 6 BLACK | Not supported. | ||||
Gyrotech/Nabco Opus | 30.5558 | 5 | 2 | 2 and 4 | 2 | 3 | 1 and 7 | Not supported. | |||
Gyrotech/Nabco U19 | 30.5558 | WHITE 6B | RED 7 | Logic Module | RED 7 | 61/62 | Not supported. | ||||
Gyrotech 300/400 8 | 30.5558 | WHITE | RED | Logic Module | RED | BLACK | Not supported. | ||||
Horton 4160-3 9 | 30.5558 | DAUGHTER BOARD | DAUGHTER BOARD | Logic Module | WHITE | BLACK | Not supported. | ||||
Horton 4190 10 | 30.5558 | 10 | 3 | 11 and 8 | 3 | 2 | Not supported. | ||||
Horton 5190 | +24 VDC | 0 V | CN16 ORANGE (10) | CN16 YELLOW (9) | CN16 GREEN (8) | CN16 BROWN (7) | CN16 PURPLE (13), BLUE (14) | Not supported. | |||
Hunter HA, DITEC HA8 | 30.5558 | SAFE 2 | RTN | ACT 2 and return | RTN | WHITE | Refer to BEA product User's Guide and OEM manual. | ||||
Keane-Monroe K | 30.5558 | YELLOW | WHITE | Logic Module | WHITE | GREEN | Not supported. | ||||
LCN Digital / Senior Swing | 30.5558 | P2 GREEN | P2 WHITE | P3 white and green | P6 GRAY | P6 YELLOW | Not supported. | ||||
Record 6000/8000 11 | 4 | 6 | 10 | 11 | 11 and 12 (N.C.) | 1 | 2 | Not supported. | |||
Stanley "L" 12 | 30.5558 | BLUE | YELLOW | Logic Module | YELLOW | ORANGE | Not supported. | ||||
Stanley MP | 30.5558 | 7 | 8 | Logic Module | 8 | 2 | Not supported. | ||||
Stanley MC 521 13 | 30.5558 | TB3-4 | TB3-3 | TB5 3 and 4 | TB4-3 | TB4-4 | Not supported. | ||||
Stanley MC 521 Pro and IQ 13 | TB4-5 | TB4-6 | TB3-4 | TB3-3 | TB5 3 and 4 | TB4-3 | TB4-4 | Not supported. | |||
Tucker | 30.5558 | J4-14 | J4-8 jumped to 12 & 13 | N.C. contact between J4 13 and COM | J4-8 jumped to 12 & 13 | J4-10 | Refer to BEA product User's Guide and OEM manual. | ||||
Tormax 1301Motion | 30.5558 | SAFETY A #2 | SAFETY A #1 | A6 | A5 | INPUT C #2 | Not supported. | ||||
Tormax TDA | 30.5558 | 7 | 8 | C4 and C8 | 8 | 2 | Refer to BEA product User's Guide and OEM manual. | ||||
Tormax TTX II | 30.5558 | 14 | 17 and 18 | 4 | 5 | Not supported. |
Notes and Clarifications
- Note 1: If only VAC power is available, a 12V transformer paired with a rectifier must be used. Do not use a 24V transformer and rectifier as this will cause damage to the product.
- Note 2: LE21 function or BR3-X programmed to function 22
- Note 3: FS3D only.
- Note 4: Monitoring consists of two purple and two blue wires. If monitoring is not used, cap off unused purple and blue wires. Wire as follows:
Effective November 11, 2017: Monitoring is required for ANSI 156.10 compliance.Door Type System Harness Control Monitoring Single 1 blue + 1 purple 1st leg 1 blue + 1 purple 2nd leg Pair / Dual Egress 1 blue + 1 purple 1st leg 1 blue + 1 purple 2nd leg Pair / Dual Egress (independent controls) 2 blues 1st control 2 purples 2nd control - Note 5 (BESAM ETIK): Jump 17+18, if not used.
- Note 6 (BESAM SW 100/200): Set EXU-SA jumper to “Door open/closed” indication. Jump 1+2 on EXU-SA board. Blanking Potentiometer must be set fully counterclockwise. Auxiliary switch may be used for home switch.
- Note 7 (DORMA ED 100/250): Jump 11+3 on control. Use ON/OFF/H.O. jumper. Control switches must be used. Make certain Home Switch Control Function "Sr" is set to 1.
- Note 8 (GYROTECH 300/400): Set control to "swing-safe."
- Note 9 (HORTON 4160-3): Must have daughter board.
- Note 10 (HORTON 4190): PNP harness p/n: 20.5322
- Note 11 (RECORD 6000/8000): Jump 11+12 and 14+15.
- Note 12 (STANLEY "L"): The older Stanley, all metal (silver), “L” shape control does not have stall. A control with stall must be used.
- Note 13 (STANLEY MC521 / MC521 PRO): Jump TB2 2+3 (if not using factory On/Off/Hold Switch).