LSI-LOGO

LSI M-Log Environmental Data Loggers

LSI-M-Log-Environmental-Data-Loggers-PRODUCT

Accessories

LSI LASTEM data loggers share a range of common accessories for their installation, communication, and power supply.

Sensors and data logger arms for indoor applications
M-Log used for temporary applications can be mounted on an arm fixed on a tripod, together with sensors.

LSI-M-Log-Environmental-Data-Loggers-FIG-1 BVA320 Sensors and data logger arm. Fixing to BVA304 tripod or to wall
Dimensions 850x610x150 mm
Number of sensors N.6 using threaded screws + N.1 ring for ESU403.1-EST033 sensors
Weight 0.5 kg
LSI-M-Log-Environmental-Data-Loggers-FIG-2 BVA315 Sensors and N.2 data logger arm. Fixing to BVA304 tripod
Dimensions 400x20x6 mm
Number of sensors N.22 using threaded screws + support for N.4 ESU403.1-EST033 sensors
Weight 1.6 kg
LSI-M-Log-Environmental-Data-Loggers-FIG-3 BVA304 Three arm tripod
Occupied area size Max 1100×1100 mm
Maximum height 1600 mm
Weight 1.6 kg
Bag for transportation Included

Power supplies 

When the data logger (see Compatibility) isn’t supplied with an ELF box, we recommend having external power supply units.

LSI-M-Log-Environmental-Data-Loggers-FIG-4 BSC015 Power supply converter/battery charger for indoor applications.
Voltage 230 V AC -> 9 V DC (1.8 A)
Connection On data logger power plug
Protection degree IP54
Compatibility M-Log (ELO009)
LSI-M-Log-Environmental-Data-Loggers-FIG-5 DEA261 Power supply converter/battery charger for indoor applications to data logger
DEA261.1 Voltage 10W-90..264V AC->13.6 V DC (750 mA)
  Connection DEA261: with 2C connector DEA261.1: free wires to data logger
    terminal board
  Protection degree IP54
  Compatibility DEA261: E-Log

DEA261.1: E-Log, Alpha-Log, ALIEM

 

 

DEA251 Power supply converter/battery charger for outdoor applications. N.2 outputs
Voltage 85…264 V AC -> 13.8 V DC
Power 30 W
Max output current 2 A
Connection to sensors or data logger On free terminals board
Protection degree IP65
Protections ·                Short Circuit

·                Overvoltage

·                Overcurrent

Operative temperature and humidity -30…+70 °C ; 20…90 %
Compatibility E-Log, Alpha-Log, ALIEM
  DYA059 Bracket for DEA251 on poles of 45…65 mm diameter

RS485 modules
Required to connect RS485 sensors (up to 3 signals) to Alpha-Log’s RS485 port.

 

LSI-M-Log-Environmental-Data-Loggers-FIG-6

TXMRA0031 Three signal RS485 active star wiring hub. The unit has three independent RS485 input and output channels, each with their own driver, which can transmit sig- nals across 1200 m of cable on each channel.
Input N.3 RS485 Channel: Data+, Data-
Output N.1 RS485 Channel: Data+, Data-
Speed 300…115200 bps
ESD protection Yes
Power supply 10…40 V DC (not insulated)
Power consumption 2.16 W
LSI-M-Log-Environmental-Data-Loggers-FIG-7 EDTUA2130 Three signal RS485 active star wiring hub.
Input N.3 RS485 Channel: Data+, Data-
Output N.1 RS485 Channel: Data+, Data-
Maximum current 16 A
Voltage 450 V DC
Protection degree IP68

Radio signals receiver

LSI-M-Log-Environmental-Data-Loggers-FIG-8 EXP301 Radio signal receiver from radio sensors or from EXP820 RS-232 Output compatible with data loggers (M/E-Log)

·                Maximum number of receivable sensors 200

·                Battery NiCd 9 V

·                Power supply 12 V DC

·                Antenna included

  DWA601A Serial cable L=10 m for connection of EXP301 to E/M-Log data logger RS-232 port
  DYA056 Support for EXP301 to pole D=45…65mm

Radio signals repeaters

LSI-M-Log-Environmental-Data-Loggers-FIG-9 EZB322 Zig-Bee radio signals repeater
Mounting Universal AC socket
Power supply 85…265 V AC, Universal AC socket
Protection degree IP52
Environmental limits 0…70 °C
Compatibility E-Log radio (ELO3515)
  EXP401 IP64 radio signals repeater “Store and forward”. Power supply: 12 V DC
  DEA260.2 Power supply 230->13,8V 0,6A for EXP401 repeater
  EXP402 IP65 radio signals repeater “Store and forward”. Power supply: 12 V DC
  DYA056 Support for EXP401-402 to pole D=45…65mm
  DWA505A Cable for EXP402, L=5 m
  DWA510A Cable for EXP402, L=10 m

Batteries
External batteries are required for E-Log, and Alpha-Log operation when not powered from the mains and or to increase the M-Log battery life. Batteries are usually mounted inside ELF boxes and connected to the data logger using the terminal power supply input.

 

LSI-M-Log-Environmental-Data-Loggers-FIG-10

MG0558.R 12 V Pb 18 Ah battery
Type Rechargeable Sealed Lead-Acid
Dimensions and weight 181x76x167 mm; 6 kg
Operating temperature ·     Charge -15…40 °C

·     Discharge -15…50 °C

·     Storage -15…40 °C

LSI-M-Log-Environmental-Data-Loggers-FIG-11 MG0560.R 12 V Pb 40 Ah battery
Type Rechargeable Sealed Lead-Acid
Dimensions and weight 151x65x94 mm; 13.5 kg
Operating temperature ·     Charge -15…40 °C

·     Discharge -15…50 °C

·     Storage -15…40 °C

LSI-M-Log-Environmental-Data-Loggers-FIG-12

 

MG0552.R 12 V Pb 2.3 Ah battery
Type Rechargeable Sealed Lead-Acid
Dimensions and weight 178x34x67 mm; 1.05 kg
Operating temperature ·     Charge -15…40 °C

·     Discharge -15…50 °C

·     Storage -15…40 °C

LSI-M-Log-Environmental-Data-Loggers-FIG-13 MG0564.R 12 V Pb 2.3 Ah battery
Type Rechargeable Sealed Lead-Acid
Dimensions and weight 330x171x214 mm; 30 kg
Operating temperature ·     Charge -15…40 °C

·     Discharge -15…50 °C

·     Storage -15…40 °C

Mini-DIN Adapters 

To connect sensors with free-wires to data loggers with min-DIN input (ELO009), these adapters are needed:

LSI-M-Log-Environmental-Data-Loggers-FIG-14 CCDCA0010 CCDCA0020 Terminal board/mini-DIN adapter+cable
N. contacts CCDCA0010: 4 + shield (for digital sensor)

CCDCA0020: 7 + shield (for analogic sensor)

Cable L=2 m

RS232 cables, USB interface
To connect data loggers to PC via RS232 or USB cable. In each pack of M-Log and E-Log , the ELA105.R serial cable and the DEB518.R USB adapter are included.

  ELA105.R L= 1,8 m serial cable

Included in each M-Log and E-Log pack

LSI-M-Log-Environmental-Data-Loggers-FIG-15 DEB518.R RS232->USB converter

Included in each M-Log and E-Log pack

RS485 converters, TCP/IP
To obtain a long cable (more than 1 Km) beetween the data logger and the PC. It is possible to use a RS232-485 converter. A TCP/IP connection to the Ethernet web, allows to send data to the PC within a network also connected via the Internet. These devices can be mounted inside ELF boxes.

LSI-M-Log-Environmental-Data-Loggers-FIG-16

 

 

DEA504.1 RS232<->RS485/422 422 converter with electrical protections
Insulation (optically) Optically insulated (2000 V)
Insulation (surge protection) From electrostatic discharge (25KV ESD)
Bit rate 300 bps…1 M bps
RS232 connector DB9 female
RS422/485 connector DB9 male, 5-pin terminal
Power supply 9…48 V DC (power supply included)
Fixing DIN bar
Cable DB9M/DB9F (included)
  MN1510. 20R Cable LAN Category 5 to connect DEA504 converters. L= 20 m
  MN1510. 25R Cable LAN Category 5 to connect DEA504 converters. L= 25 m
  MN1510. 50R Cable LAN Category 5 to connect DEA504 converters. L= 50 m
  MN1510. 200R Cable LAN Category 5 to connect DEA504 converters. L= 200 m
LSI-M-Log-Environmental-Data-Loggers-FIG-17

 

 

DEA553 Industrial secure serial port to Ethernet device server with 1xRS-232/422/485 and 2×10/100Base-T(X)
Input RS232/422/485 (DB9)
Output Ethernet 10/100Base-T(x) Auto MDI/ MDIX
Protocols ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP, V1/V2c, HTTPS, SMTP
Power supply 12…48 V DC
Consumption 1.44 W
Operative Temperature -40…70 °C
Fixing DIN bar
Protection degree IP30
Weight 0,227 kg
 

LSI-M-Log-Environmental-Data-Loggers-FIG-18

 

DEA509 Gateway Modbus-TCP. Modbus-RTU in Modbus TCP converter
Input RS232/422/485 (DB9)
Output Ethernet 10/100 M
ESD protection 15 KV for serial port
Magnetic protections 1.5 KV for Ethernet port
Power supply 12…48 V DC
Consumption 200 mA @ 12V DC, 60 mA@ 48V DC
Operative Temperature 0…60 °C
Fixing DIN bar
Protection degree IP30
Weight 0.34 kg

Converter RS232/RS485 – > optical fibre

LSI-M-Log-Environmental-Data-Loggers-FIG-19 TXMPA1151 Serial converter RS232 / optical fibre mono modal
TXMPA1251 Serial converter R485 / optical fibre mono modal

Dropping resistors

  EDECA1001 Five 50 ohm-resistors kit (1/8 W, 0.1%, 25 ppm) to convert 4…20 mA -> 200…1000 mV

Modem GPRS, 3G, 4G. UMTS Router. Wi-Fi Module
For remote connections, 3G-4G modems are available. Via modem, is possible to send (“push mode”) data to FTP server or, using the program P1-CommNET, to LSI LASTEM GIDAS database. These devices can be mounted inside ELF boxes.

LSI-M-Log-Environmental-Data-Loggers-FIG-20 DEA718.3 Modem GPRS – GSM-850 / EGSM-900 / DCS-1800 / PCS-1900 MHz Quad-Band.

GPRS class 10

Operative temperature -20…70 °C
Power supply 9…24 V DC from data logger
Consumption Sleep: 30 mA, during com. 110 mA
Weight 0.2 kg
Compatibility E-Log
  ELA110 Connection cable between E-Log and DEA718.3 modem
  MC4101 Fixing bar for DEA718.3 in ELF boxes
  DEA609 Modem adapter DEA718.3 / external antenna DEA611
 

 

LSI-M-Log-Environmental-Data-Loggers-FIG-21

 

 

TXCMA2200 Modem 4G/LTE/HSPA/WCDMA/GPRS Quadband/class 10/class12
LTE FDD Download speed 100Mbps Upload speed 50Mbps
Frequency band (MHz) 850/900/1800/1900MHz
Input 2 x RS232, 1 x RS485
Cellular Antenna Standard SMA female interface, 50 ohm, lighting protection(optional)
SMS Yes
Connection cable to data logger Included
Operative Temperature -35…75 °C
Power supply 5…36 V DC from data logger
Consumption @12 V Sleep: 3 mA. Standby: 40-50 mA. Communication mode: 75-95 mA
Casing Iron, IP30
Mounting DIN bar
Weight 0.205 kg
Compatibility Alpha-Log
 

 

 

LSI-M-Log-Environmental-Data-Loggers-FIG-22

DEA611 External antenna for 3G, LTE modem TXCMA2200 double gain GPRS/UMTS/LTE
Frequencies GSM/GPRS/EDGE: 850 / 900 / 1800 /

1900 MHz. UMTS/WCDMA: 2100 MHz

LTE: 700 / 800 / 1800 / 2600 MHz

Free license ISM band Field 869 MHz, UHF Frequency
Irradiation Omnidirectional
Gain 2 dBi
Power (max) 100 W
Impedance 50 Ohm
Cable L=5 m
Fixing accessory Included
Compatibility TXCMA2200, DEA718.3 (with DEA609)
LSI-M-Log-Environmental-Data-Loggers-FIG-23

 

 

TXMPA3770 High-Gain 2.4 GHz Wi-Fi USB adapter
Wireless data rate Up to 150 Mbps
Port USB 2.0
Security WEP, WPA, WPA2, WPA-PSK/WPA2-PSY

Encryptions

Standard IEE802.11
Environmental limits 0…40 °C (Not condensing)
Weight / Dimensions 0.032 kg / 93.5 x 26 x 11 mm
 

 

 

 

 

LSI-M-Log-Environmental-Data-Loggers-FIG-24

TXCRB2200 TXCRB2210 TXCRB2200.D Dual SIM Industrial 4G/LTE Wi-Fi router, 3 models depending on number of LAN ports (e.g. data logger and camera with ethernet) and region covered
Mobile 4G (LTE), 3G
Max data rate LTE: 150 Mbps. 3G: 42 Mbps
WiFi WPA2-PSK, WPA-PSK, WEP, MAC Filter
Ethernet WAN port N.1 (config. to LAN) 10/100 Mbps
Ethernet LAN port ()10/100 Mbps ·        N.1 (TXCRB2200, TXCRB2200.1)

·        N.4 (TXCRB2210)

Network protocols TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, FTP, SMTP, SSL v3, TLS, ARP, VRRP, PPP, PPPoE, UPnP, SSH,

DHCP, Telnet, SMNP, MQTT, Wake On Lan (WOL)

Region (operator) ·         TXCRB2200, TXCRB2210: Global

·         TXCRB2200.D: Europe, The Middle

East, Africa

Frequencies ·       TXCRB2200, TXCRB2210: 4G (LTE- FDD): B1, B2, B3, B4, B5, B7, B8, B12, B13, B18, B19, B20, B25, B26, B28. 4G (LTE-TDD): B38, B39, B40, B41. 3G: B1, B2, B4, B5, B6, B8, B19. 2G: B2, B3, B5, B8

·       TXCRB2200.1: 4G (LTE-FDD): B1, B3, B5, B7, B8, B20. 4G (LTE-FDD): B1, B3, B7, B8, B20. 3G: B1, B5, B8. 2G: B3, B8

Power supply 9…30 V DC (<5W)
Operating temperature -40…75 °C
Weigth 0.125 kg
Compatibility Alpha-Log
LSI-M-Log-Environmental-Data-Loggers-FIG-25 TXANA3033 Network directional antenna 28dBi
Weight / Dimensions 550 g / 110 x 55 mm
Cable H=3 m
Compatibility TXCRB2200-00.1, TXCRB2210
 

LSI-M-Log-Environmental-Data-Loggers-FIG-26

 

TXRMA4640 Satellite Modem (GPS+GLONASS L1 freq.) Thuraya M2M
Narrowband IP UDP and TCP/IP
Frequency band TX 1626.5 to 1675.0 MHz

R X 1518.0 to 1559.0 MHz

Typical latency < 2 s 100 bytes
Power 10…32 V DC
Wi-Fi IEEE 802.11 B/G, 2.4 GHz
Weight / Size (L x W x H) < 900 g / 170 x 130 x 42 mm
Operative temperature -40°C…+71 °C
Support to pole DYA062
LSI-M-Log-Environmental-Data-Loggers-FIG-27

 

 

 

 

 

TXCRA1300 Industrial router 3G/LTE dual SIM, removable magnetic antenna. Input RS232/485 for communication of independent devices
Max data rate 3G: 14 Mbps
SMS
Ethernet LAN port N.1 LAN port, 10/100BT
Network protocols PPP,PPPoE,TCP, UDP,DHCP,ICMP,NAT, DMZ, RIPv1/v2,OSPF, DDNS, VRRP, HT TP,HTTPs,DNS, ARP,QoS,SNTP, Telnet
Power supply 9…26 V DC (<5W)
Operating temperature -40…75 °C
Compatibility M-Log, E-Log
Communication ports RS232, RS485
Antenna 3G/2G Omnidiretional Quad-Band included + second connector
LSI-M-Log-Environmental-Data-Loggers-FIG-28

 

 

 

TXRGA2100 Router/repeater/client Wi-Fi industrial
Wi-Fi N.1 radio IEEE 802.11a/b/g/n, MIMO 2T2R, 2.4 / 5 GHz
Sensitivity Receiver: -92 dBm for 802.11 b/g/n and -96 dBm for 802.11a/n
Ethernet LAN Port N.1 LAN port Gigabit 10/100/1000 Base TX auto-sensing, auto MDI/MDIX
Power Supply 9…48 V DC
Operative temperature -20…60 °C
Compatibilità Alpha-Log
Flat antennas N.2 3dBi@2,4 GHz/4dBi@5GHz
Mounting on DIN bar With kit MAOFA1001
LSI-M-Log-Environmental-Data-Loggers-FIG-29 TXANA1125 Omnidirectional antenna SISO “stick” 2 dB
Bandwidth Broad 698..3800 MHz
Gain 2 dB
Length 16 cm
Cable 3 m with SMA connector
Mounting Pole/wall mounting kit included
LSI-M-Log-Environmental-Data-Loggers-FIG-30 TXANA1125

.1

Omnidirectional antenna SISO “stick” 6 dB
Bandwidth 2.4 GHz
Gain 6 dB
Length 25 cm
Cable 2 m with N-f/RSMA connector
Mounting Pole/wall mounting plate included

Long distance VHF radio
VHF radios allow easy, cost-free connections, several kilometers away. Via radio, it is possible to connect several data loggers with MASTER/SLAVE logic or to connect a data logger to a PC. These devices can be mounted inside ELF boxes.

LSI-M-Log-Environmental-Data-Loggers-FIG-31

 

 

 

 

 

TXRMA2132 160 MHz radio modem for PC or data logger connection, VHF-500 mW erp; includes 3 elements Yagi antenna. Transmitting part of the system, connected with ELA110+ELA105 to a data logger, included in M-Log and E-Log.
Operating band 169.400. 169.475 MHz
Output power 500 mW ERP
Number of channels 12.5 – 25 – 50 kHz
Radio data rate (Tx/Rx) 4.800 bps@12.5kHz, 9600 bps@25kHz, 19200 bps @50 kHz
Power supply 9…32 V DC
Consumption 140 mA (Rx)
Operative temperature -30…70 °C
Antenna Included. N.3 elements antenna Yagi. L=10 m cable
Line-of-sight 7…10 km
Weight 0.33 kg without antenna
Communication port RS232, RS485
LSI-M-Log-Environmental-Data-Loggers-FIG-32 TXRMA2131 160 MHz radio modem for PC or data logger connection, VHF-200 mW erp; includes dipole antenna. Receiving part connected with ELA105.
Main features See TXCMA2132
Antenna Included Dipole antenna L=5 m cable
  ELA110 Connection cable radio/data logger
  ELA105 Serial cable L=1.8 m. To be quoted to connect TXMA2131 to PC. Included in

each package of M-Log and E-Log for data logger connection.

LSI-M-Log-Environmental-Data-Loggers-FIG-33 DEA260.1 230 V AC/12V DC power supply for radio TXRMA2131 PC side
  DEA605 Serial adapter null-modem 9M/9F
  DEA606.R Serial adapter null-modem 9M/9M

Solar panel
For applications where mains power is not available or where a double power supply is required, the data logger can be powered by a photovoltaic panel. In these cases it is advisable to place the data logger inside an ELF345-345.1 box that in-cludes DYA115 regulator that doesn’t have to be supplied separately. When a solar panel supply is present, an external bat-tery must be housed in the ELF345 box model MG0558.R (18 Ah) or MG0560.R (44 Ah), chosen according to the autonomy required and the availability of hours of sunshine. The solar panel is mounted on a pole through a tiltable support (DYA064).

LSI-M-Log-Environmental-Data-Loggers-FIG-34 DYA109 80 Wp solar panel
Power 80 Wp
Operative voltage (VMP) 21.57 V
VOC voltage 25.45 V
Dimensions 815×535 mm
Weight 4.5 kg
Technology Monocristalline
Frame material Aluminium
Cable L=5 m
Regulator (DYA115) ·     Battery Voltage: 12/24V

·     Charge/Discharge Current: 10 A

·     Battery type: Lead/Acid

·     Float voltage: 13.7 V

·     Auto Power Off Voltage: 10.7 V

·     Auto Reconnect Voltage: 12.6 V

·     Self-consumption: < 10 mA

·     USB Output: 5 V /1.2 A Max

·     Operating temperature: -35…60 °C

·     included inside ELF345-345.1 boxes

·     Inside Alpha-Log

LSI-M-Log-Environmental-Data-Loggers-FIG-35 DYA064 Tiltable support for solar panel fixing to poles of diam. 45…65 mm Weigth: 1.15 kg

Shockproof case to contain data loggers in portable applications 

For portable applications, data loggers can be mounted inside IP66 cases to be protected against shocks, water, dust and atmospheric agents. Inside the case can be also be housed the communication device.

LSI-M-Log-Environmental-Data-Loggers-FIG-36 ELF432 Portable IP66 shockproof case. Complete with rechargeable battery (18 Ah) and power supply/battery charger (230 V AC/13,8 V DC)
Dimensions 520 x 430 x 210 mm
Weight 12 kg
Compatibility E-Log, Alpha-Log

IP66 boxes for data logger fix installations
For fix outdoor installations, data loggers can be mounted inside IP66 enclosures that give protection against shocks, water, dust and atmospheric agents. Each box houses the relative power supply system as well as specific accessories, and has the predisposition to house the communication device that can be chosen from the list of Accessories. Each box can be equip-ped with a support for pole or wall fixing.

ELF345 IP66 box. Complete with regulator for photovoltaic panels. Compatibility with 18 or 44 Ah batteries
Power supply From solar panel using regulator
Solar panel regulator Included
Dimensions H 502 x L 406 x D 230 mm
Weight 7 kg (battery excluded)
Material Fiberglass
Compatible batteries (not included) MG0558.R (18 Ah), MG0560.R (44 Ah)
Compatibility E-Log, Alpha-Log
ELF345.1 IP66 box. Complete with regulator for photovoltaic panels and 85-264 V AC bat- tery charger power supply. Compatibility with 18 or 44 Ah batteries.
Solar panel regulator Included
Power supply 85-264 V AC-> 13.8 V DC

Thermal magnetic switch. Power: 50W

Dimensions H 502 x L 406 x D 230 mm
Weight 17.5kg (battery excluded)
Material Fiberglass
Compatibility E-Log, Alpha-Log
ELF345.3 IP66 box for Alpha-Log connection to photovoltaic panels. Compatibility with 18 or 44 Ah batteries
Power supply From solar panel using regulator in- side Alpha-Log
Dimensions H 502 x L 406 x D 230 mm
Weight 7 kg (battery excluded)
Material Fiberglass
Compatible batteries (not included) MG0558.R (18 Ah), MG0560.R (44 Ah)
Compatibility Alpha-Log
ELK340 IP66 box. Complete with 85-240 V AC-> 13.8 V DC power supply (30 W) and 2 Ah battery.
Power supply 85-240 V AC-> 13.8 V DC

Thermal magnetic switch. Power: 30W

Dimensions H 445 mm × L 300 mm P 200 mm
Weight 5 kg
Material Polyester
Battery 2 Ah rechargeable, included
Compatibility E-Log, Alpha-Log, ALIEM

LSI-M-Log-Environmental-Data-Loggers-FIG-37 LSI-M-Log-Environmental-Data-Loggers-FIG-38

ELF340 IP66 box. Complete with 85-264 Vca-> 13.8 V DC power supply (50 W) and 2 Ah battery. Compatibility with 18 or 44 Ah batteries
Power supply 85-264 V AC-> 13.8 V DC

Thermal magnetic switch. Power: 50W

Dimensions H 502 x L 406 x D 230 mm
Weight 7 Kg
Material Fiberglass
Battery 2 Ah rechargeable, included
Compatibility E-Log, Alpha-Log
ELF340.10 IP66 box. Complete with 85-264 V AC-> 13.8 V DC power supply and 2 Ah batte- ry and 230/24V transformer. With provision for installation of Relays for actua- tions (MG3023.R type) and IN-OUT terminal for analogue signals
Power supply 85-264 V AC-> 13.8 V DC 30W

230V AC/24V AC 40VA

Thermal magnetic

Provision for Relays (not included) Up to N.5 Relays (MG3023.R type)
IN-OUT signals terminal board Terminal for analog signals input

N.7 IN signals

N.7 OUT signals

ELF340.8 IP66 box. Complete with 85-264 V AC-> 13.8 V DC power supply and terminal board for up to N.3 RS485 signals. Compatibility with 2, 18 or 40 Ah batteries. Used to receive digital signals
Power supply 85-264 V AC-> 13.8 V DC 50W

Thermal magnetic

Dimensions H 502 x L 406 x D 230 mm
Weight 7,5 kg
Compatibility E-Log, Alpha-Log
ELF344 IP66 box. Complete with 85-264 V AC-> 13.8 V DC power supply, 2Ah battery and 230 V AC/24 V AC transformer for heated sensors
Power supply 85-264 V AC-> 13,8 V DC 2A 30W
Transformer 230V AC/24V AC 4.1 A 100VA
Dimensions H 502 x L 406 x D 230 mm
Weight 7.5 kg
Battery 2Ah rechargeable, included
Compatibility E-Log, Alpha-Log

LSI-M-Log-Environmental-Data-Loggers-FIG-39 LSI-M-Log-Environmental-Data-Loggers-FIG-40

ELK347 IP66 box. Complete with 85-240 V AC-> 13,8 V DC power supply, 2Ah battery and 85-260 V AC -> 24 V DC transformer for ALL IN ONE heated version sensors
Power supply 85-240 V AC -> 13,8 V DC 30W
Transformer 85-260 V AC -> 24 V DC 150 W
Dimensions H 445 mm × L 300 mm P 200 mm
Weight 5,5 kg
Battery 2 Ah rechargeable, included
Compatibility Alpha-Log
DYA074 Support for ELF enclosures H 502 x L 406 x P160 mm to pole Ø 45…65 mm
DYA072 Support for ELF enclosures H 502 x L 406 x P 160 mm to wall
DYA148 Support for two ELF enclosures H 502 x L 406 x P160 mm to pole Ø 45…65 mm
MAPFA2000 Support for ELK enclosures H 445 × L 300 P 200 mm to pole Ø 45…65 mm
DYA081 Door lock for ELFxxx boxes
MAPSA1201 Protection tile for ELFxxx boxes. Dimensions: 500 x 400 x 230 mm
SVSKA1001 Fixing kit for Alpha-Log in ELFxxx boxes when E-Log is already installed
MAGFA1001 Cable gland for ELF340-340.7-345-345.1-345.3-344-347 box and RJ45 / Ethernet cable

LSI-M-Log-Environmental-Data-Loggers-FIG-41

Carrying cases 

To transport data loggers and their accessories, LSI LASTEM supplies the following cases.

BWA314 Shockproof case, watertight (52x43x21 cm) for data loggers and probes Weight:3.9 kg
BWA319 Shockproof case with wheels, watertight (68x53x28 cm) for data loggers and probes

Weight: 7 kg

BWA047 Soft bag for data logger transport Weight: 0.8 kg
BWA048 Bag to transport BVA304 tripod and stands Weight: 0.4 kg

LSI-M-Log-Environmental-Data-Loggers-FIG-42

Relay
Data logger versions with terminal inputs can switch external devices on/off via their digital outputs. The voltage available at the outputs corresponds to the supply voltage of the data logger (normally 12 V DC). In order to convert the output into a clean On/Off contact, LSI LASTEM provides relay suitable for mounting inside ELF boxes.

MG3023.R Relay for On-Off actuation of the digital output. DPDT type.
Maximum switching voltage contact Minimum switching voltage contact Min. switching current contact Limiting continuous current contact Typical input current coil

Coil voltage

Protective circuit

Operating voltage display

250 V AC/DC

5 V (at 10 mA)

10 mA (At 5 V)

8 A

33 mA

12 V DC

Damping diode

Yellow LED

MG3024.R Maximum switching voltage contact Minimum switching voltage contact Min. switching current contact Limiting continuous current contact Typical input current coil

Coil voltage Protective circuit

Operating voltage display

400 V AC/DC

12 V (at 10 mA)

10 mA (At 12 V)

12 A

62.5 mA 12 V DC

Damping diode Yellow LED

LSI-M-Log-Environmental-Data-Loggers-FIG-43

USB Drive

XLA010 USB Pen drive 3.0 Industrial Grade, Flash type MLC
Capacity 8 Gb
Power consumption 0.7 W
Operative temperature -40…85 °C
Vibration 20 G @7…2000 Hz
Shock 1500 G @ 0.5 ms
MTBF 3 million hours

LSI-M-Log-Environmental-Data-Loggers-FIG-44

Data logger protections

EDEPA1100 Protection unit (SPD) for power line, single phase 230 V.
Mounting DIN bar
Compatibility Alpha-Log, E-Log
EDEPA1101 Protection unit (SPD) for RS-485 communication line.
Mounting DIN bar
Compatibility Alpha-Log, E-Log
EDEPA1102 Protection unit (SPD) for Ethernet communication line.
Mounting DIN bar
Compatibility Alpha-Log, G.Re.T.A.

LSI-M-Log-Environmental-Data-Loggers-FIG-56

Optical/acoustic signallers

SDMSA0001 Optical/acoustic signaller for indoor use
Lens colour Red
Power supply 5…30 V DC
Protection grade IP23
Operative temperature -20…60 °C
SDMSA0002 Optical/acoustic signaller for outdoor use with 8 SMT LED
Lens colour Red
Power supply 10..17 V AC/DC
Protection grade IP65
Operative temperature -20…55 °C

Graphic displaysLSI-M-Log-Environmental-Data-Loggers-FIG-57

SDGDA0001 Graphic display with touch screen and graphic interface for local management (configuration, diagnostic, data download, etc) of the datalogger
Memory dimension 6 GB
Storage capacity 128 GB
Display 8’’ touch screen
Ports USB-C
Connectivity Wi-Fi
Protection grade IP68
Dimensions / Weight 126,8 x 213,8 x 10,1 mm / 0,433 kg
Operative temperature -40…60 °C
Data logger compatibility Alpha-Log

LSI LASTEM Srl
Via Ex SP. 161 Dosso, 9 20049 Settala (MI) Italy

Specifications

  • Dimensions: 850x610x150 mm
  • Weight: 0.5 kg
  • Number of Sensors: 6 using threaded screws + 1
    ring for ESU403.1-EST033 sensors

Product Usage Instructions

Sensors and Data Logger Arm Installation
For indoor applications, mount the M-Log on an arm fixed to a tripod along with the sensors.

Power Supply Connection
Connect the power supply unit to the data logger following the provided instructions based on the model and application.

RS485 Modules Setup
To connect RS485 sensors, use the TXMRA0031 or EDTUA2130 active star wiring hub. Follow the specifications for input/output channels and power requirements.

Radio Signals Receiver Setup
When using the EXP301 radio signals receiver, ensure proper antenna installation and connection to the data logger.

FAQ

Q: What power supply units are recommended for outdoor applications?
A: For outdoor use, the DEA251 or DYA059 power supply converter/battery charger is suitable, providing 30W power with IP65 protection.

Q: How many sensors can be connected to the data logger arm?
A: The larger data logger arm supports up to 22 sensors using threaded screws and additional support for 4 ESU403.1-EST033 sensors.

Q: What is the maximum height of the three-arm tripod?
A: The three-arm tripod can reach a maximum height of 1600 mm.

Documents / Resources

LSI M-Log Environmental Data Loggers [pdf] Owner's Manual
BVA320, BVA315, BVA304, BSC015, DEA261, DEA261.1, DEA251, DYA059, TXMRA0031, M-Log Environmental Data Loggers, M-Log, Environmental Data Loggers, Data Loggers, Loggers
LSI M-Log Environmental Data Loggers [pdf] Owner's Manual
BVA320, BVA315, BVA304, ELF432, ELF345, ELF345.1, ELF345.3, ELK340, M-Log Environmental Data Loggers, M-Log, Environmental Data Loggers, Data Loggers, Loggers

References

Leave a comment

Your email address will not be published. Required fields are marked *