Owner's Manual for LSI models including: BVA320, BVA315, BVA304, ELF432, ELF345, ELF345.1, ELF345.3, ELK340, M-Log Environmental Data Loggers, M-Log, Environmental Data Loggers, Data Loggers, Loggers

LSI Lastem

Greta Tresoldi

MW9005-ENG-07-Accessories Installation

Index of /solfycta-uploads/PDF/MW9005

environmental data loggers

3 days ago — For fix outdoor installations, data loggers can be mounted inside IP66 enclosures that give protection against shocks, water, dust and atmospheric agents.


File Info : application/pdf, 6 Pages, 359.00KB

PDF preview unavailable. Download the PDF instead.

MW9005-ENG-07-Accessories Installation
ENVIRONMENTAL DATA LOGGERS
Accessories Field Installation

Accessories --Field Installation

Sensors and data logger arms for indoor applications

When M-Log is used in indoor applications, it can be mounted on an arm fixed on a tripod, together with a series of sensors.

BVA320 BVA315 BVA304

Sensors and data logger arm. Fixing to BVA304 tripod or to wall

Dimensions

850x610x150 mm

Number of sensors

N.6 using threaded screws + N.1 ring for ESU403.1-EST033 sensors

Weight

0.5 kg

Sensors and N.2 data logger arm. Fixing to BVA304 tripod

Dimensions

400x20x6 mm

Number of sensors

N.22 using threaded screws + support for N.4 ESU403.1-EST033 sensors

Weight

1.6 kg

Three arm tripod

Occupied area size

Max 1100x1100 mm

Maximum height

1600 mm

Weight

1.6 kg

Bag for transportation

Included

Shockproof case to contain data loggers in portable applications
For portable applications, data loggers can be mounted inside IP66 cases to be protected against shocks, water, dust and atmospheric agents. Inside the case can be also be housed the communication device.

ELF432

Portable IP66 shockproof case. Complete with rechargeable battery (18 Ah) and power supply/battery charger (230 V AC/13.8 V DC)

Dimensions Weight Compatibility

520 x 430 x 210 mm 12 kg E-Log, Alpha-Log

MW9005-ENG-07-29/11/2024
1

Accessories

IP66 boxes for data logger fix installations

For fix outdoor installations, data loggers can be mounted inside IP66 enclosures that give protection against shocks, water, dust and atmospheric agents. Each box houses the relative power supply system as well as specific accessories, and has the predisposition to house the communication device that can be chosen from the list of Accessories. Each box can be equipped with a support for pole or wall fixing.

ELF345 ELF345.1 ELF345.3 ELK340

IP66 box. Complete with regulator for photovoltaic panels. Compatibility with 18 or 44 Ah batteries

Power supply

From solar panel using regulator

Solar panel regulator

Included

Dimensions

H 502 x L 406 x D 230 mm

Weight

7 kg (battery excluded)

Material

Fiberglass

Compatible batteries (not included)

MG0558.R (18 Ah), MG0560.R (44 Ah)

Compatibility

E-Log, Alpha-Log

IP66 box. Complete with regulator for photovoltaic panels and 85-264 V AC battery charger power supply. Compatibility with 18 or 44 Ah batteries.

Solar panel regulator

Included

Power supply

85-264 V AC-> 13.8 V DC Thermal magnetic switch. Power: 50W

Dimensions

H 502 x L 406 x D 230 mm

Weight

17.5 kg (battery excluded)

Material

Fiberglass

Compatibility

E-Log, Alpha-Log

IP66 box for Alpha-Log connection to photovoltaic panels. Compatibility with 18 or 44 Ah batteries

Power supply

From solar panel using regulator inside Alpha-Log

Dimensions

H 502 x L 406 x D 230 mm

Weight

7 kg (battery excluded)

Material

Fiberglass

Compatible batteries (not included)

MG0558.R (18 Ah), MG0560.R (44 Ah)

Compatibility

Alpha-Log

IP66 box. Complete with 85-240 V AC-> 13.8 V DC power supply (30 W) and 2 Ah battery.

Power supply

85-240 V AC-> 13.8 V DC Thermal magnetic switch. Power: 30W

Dimensions

H 445 mm × L 300 mm P 200 mm

Weight

5 kg

Material

Polyester

Battery

2 Ah rechargeable, included

Compatibility

E-Log, Alpha-Log, ALIEM

2 2

Accessories

ELF340 ELF340.10 ELF340.8 ELF344

IP66 box. Complete with 85-264 Vca-> 13.8 V DC power supply (50 W) and 2 Ah battery. Compatibility with 18 or 44 Ah batteries

Power supply

85-264 V AC-> 13.8 V DC Thermal magnetic switch. Power: 50W

Dimensions

H 502 x L 406 x D 230 mm

Weight

7 Kg

Material

Fiberglass

Battery

2 Ah rechargeable, included

Compatibility

E-Log, Alpha-Log

IP66 box. Complete with 85-264 V AC-> 13.8 V DC power supply and 2 Ah battery and 230/24V transformer. With provision for installation of Relays for actuations (MG3023.R type) and IN-OUT terminal for analogue signals

Power supply

85-264 V AC-> 13.8 V DC 30W

230V AC/24V AC 40VA

Thermal magnetic

Provision for Relays (not included)

Up to N.5 Relays (MG3023.R type)

IN-OUT signals terminal board

Terminal for analog signals input

N.7 IN signals

N.7 OUT signals

IP66 box. Complete with 85-264 V AC-> 13.8 V DC power supply and terminal board for up to N.3 RS485 signals. Compatibility with 2, 18 or 40 Ah batteries.

Used to receive digital signals

Power supply

85-264 V AC-> 13.8 V DC 50W

Thermal magnetic

Dimensions

H 502 x L 406 x D 230 mm

Weight

7,5 kg

IP66 box. Complete with 85-264 V AC-> 13.8 V DC power supply, 2Ah battery

Compatibility

E-Log, Alpha-Log

Power supply Transformer Dimensions Weight Battery Compatibility

85-264 V AC-> 13,8 V DC 2A 30W 230V AC/24V AC 4.1 A 100VA H 502 x L 406 x D 230 mm 7.5 kg 2Ah rechargeable, included E-Log, Alpha-Log

3 3

Accessories

ELK347

IP66 box. Complete with 85-240 V AC-> 13,8 V DC power supply, 2Ah battery and 85-260 V AC -> 24 V DC transformer for ALL IN ONE heated version sensors

Power supply

85-240 V AC -> 13,8 V DC 30W

Transformer

85-260 V AC -> 24 V DC 150 W

Dimensions

H 445 mm × L 300 mm P 200 mm

Weight

5,5 kg

Battery

2 Ah rechargeable, included

Compatibility

Alpha-Log

DYA074

Support for ELF enclosures H 502 x L 406 x P160 mm to pole Ø 45...65 mm

DYA072

Support for ELF enclosures H 502 x L 406 x P 160 mm to wall

DYA148

Support for two ELF enclosures H 502 x L 406 x P160 mm to pole Ø 45...65 mm

MAPFA2000 Support for ELK enclosures H 445 × L 300 P 200 mm to pole Ø 45...65 mm

DYA081

Door lock for ELFxxx boxes

MAPSA1201 Protection tile for ELFxxx boxes. Dimensions: 500 x 400 x 230 mm

SVSKA1001 Fixing kit for Alpha-Log in ELFxxx boxes when E-Log is already installed

MAGFA1001 Cable gland for ELF340-340.7-345-345.1-345.3-344-347 box and RJ45 / Ethernet cable

Carrying cases
To transport data loggers and their accessories, LSI LASTEM supplies the following cases.

BWA314 BWA319

Shockproof case, watertight (52x43x21 cm) for data loggers and probes Weight:3.9 kg
Shockproof case with wheels, watertight (68x53x28 cm) for data loggers and probes Weight: 7 kg

BWA047

Soft bag for data logger transport Weight: 0.8 kg

BWA048

Bag to transport BVA304 tripod and stands Weight: 0.4 kg

4 4

Accessories

Relay
Data logger versions with terminal inputs can switch external devices on/off via their digital outputs. The voltage available at the outputs corresponds to the supply voltage of the data logger (normally 12 V DC). In order to convert the output into a clean On/Off contact, LSI LASTEM provides relay suitable for mounting inside ELF boxes.

MG3023.R MG3024.R

Relay for On-Off actuation of the digital output. DPDT type.

Maximum switching voltage contact Minimum switching voltage contact Min. switching current contact Limiting continuous current contact Typical input current coil Coil voltage Protective circuit Operating voltage display

250 V AC/DC 5 V (at 10 mA) 10 mA (At 5 V) 8 A 33 mA 12 V DC Damping diode Yellow LED

Maximum switching voltage contact Minimum switching voltage contact Min. switching current contact Limiting continuous current contact Typical input current coil Coil voltage Protective circuit Operating voltage display

400 V AC/DC 12 V (at 10 mA) 10 mA (At 12 V) 12 A 62.5 mA 12 V DC Damping diode Yellow LED

USB Drive

XLA010

USB Pen drive 3.0 Industrial Grade, Flash type MLC

Capacity

8 Gb

Power consumption

0.7 W

Operative temperature

-40...85 °C

Vibration

20 G @7...2000 Hz

Shock

1500 G @ 0.5 ms

MTBF

3 million hours

Data logger protections

EDEPA1100 Protection unit (SPD) for power line, single phase 230 V.

Mounting

DIN bar

Compatibility

Alpha-Log, E-Log

EDEPA1101 Protection unit (SPD) for RS-485 communication line.

Mounting

DIN bar

Compatibility

Alpha-Log, E-Log

EDEPA1102 Protection unit (SPD) for Ethernet communication line.

Mounting

DIN bar

Compatibility

Alpha-Log, G.Re.T.A.

5 5

Accessories

Optical/acoustic signallers

SDMSA0001 SDMSA0002

Optical/acoustic signaller for indoor use

Lens colour

Red

Power supply

5...30 V DC

Protection grade

IP23

Operative temperature

-20...60 °C

Optical/acoustic signaller for outdoor use with 8 SMT LED

Lens colour

Red

Power supply

10..17 V AC/DC

Protection grade

IP65

Operative temperature

-20...55 °C

Graphic displays

SDGDA0001 Graphic display with touch screen and graphic interface for local management (configuration, diagnostic, data download, etc) of the datalogger

Memory dimension

6 GB

Storage capacity

128 GB

Display

8'' touch screen

Ports

USB-C

Connectivity

Wi-Fi

Protection grade

IP68

Dimensions / Weight

126,8 x 213,8 x 10,1 mm / 0,433 kg

Operative temperature

-40...60 °C

Data logger compatibility

Alpha-Log

LSI LASTEM Srl Via Ex SP. 161 Dosso, 9 20049 Settala (MI) Italy

Tel. +39 02 954141 Fax +39 02 95770594 Email info@lsi-lastem.com www.lsi-lastem.com
6 6



References

Microsoft Publisher per Microsoft 365