Danfoss RET Series Electronic Dial Setting Thermostat with LCD Display Installation Guide
Danfoss RET Series Electronic Dial Setting Thermostat with LCD Display

Installation Instructions

Features RET B (RF) / RET B-LS (RF) / RET B-NSB (RF)
Contact rating 10 – 230 Vac, 3 (1) (excl. North America)
Contact rating (N.America) 10 – 24 Vac, 50/60Hz, 3(1)A
Temperature Accuracy ±1°C
Contact Type SPDT Type 1B
Transmitter frequency 433.92 MHz (RF models)
Transmitter range 30m max (RF models)
Power Supply 2 x AA/MN1500 alkaline batteries
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5 kV
Designed to meet BS EN 60730-2-9 (EN 300220 for RF)
Ball Pressure Test 75°C
Temperature Range 5-30°C
Dimensions (mm) 85 wide x 86 high x 42 deep

Important note RF products: Ensure that there are no large metal objects, such as boiler cases or other large appliances, in line of sight between the transmitter and receiver as these will prevent communication between thermostat and receiver.

Mounting

Mounting

Fix at a height of 1.5m approx from the floor, away from draughts or heat sources such as radiators, open fires or direct sunlight.
Mounting

Wiring (not RF models)

Wiring Models

HEATING
Wiring Models
Wiring Models
Wiring Models
Wiring Models

DIL switch settings

Slide the DIL switches to the settings required (see below)
Switch Settings

Heating selection
Heating Selection

Cooling selection
Cooling Selection

ON/OFF boiler switches ON when below set temperature and OFF when above

CHRONO energy saving feature which fires the boiler at regular intervals to maintain a set temperature, achieving a constant ambient environment for the user.

  • use 6 Cycles for radiator systems
  • use 3 Cycles for underfloor heating

Locking & Limiting

Locking & Limiting
Locking & Limiting

Receiver Wiring (RF only)

RX1 & RX2
Receiver Wiring

RX3
Receiver Wiring

Note: 1) For mains voltage operated systems, link terminal 2 to mains live supply 2) Power supply to unit must not be switched by timeswitch

Commissioning (RF only)

If the thermostat and the receiver have been supplied together in a combined pack, the units have been paired in the factory and no commissioning is required (RX1 only).

Step 1 RET B-RF
Commissioning

Position the setting dial to number 1. Remove dial, press & hold LEARN button for 3 seconds (located under setting dial).

Do not replace the setting dial yet
NOTE: Thermostat now transmits signal continuously for 5 mins.

Step 2 RX1
Press and hold buttons PROG and CH1 until green light flashes.

Step 3 RX2/RX3
For RX2 or RX3 repeat steps 1 and 2 for each thermostat and channel, leaving at least 5 mins between the commissioning of each thermostat.

Step 4 RET B-RF
To replace the thermostat setting dial, position the dial to number 1.

Instructions

Instructions
Instructions

What is a room thermostat?

an explanation for householders. A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators.
Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.

The heating system will not work if a time switch or programmer has switched it off.
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18°C-and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the thermostat from working properly.

User Instructions

Display
The LCD displays actual room temperature until the setting dial is moved.

Setting the temperature
Turn setting dial to required temperature. The selected temperature will flash in the LCD to signify it is showing set temperature.

After a short period the display stops flashing and shows actual room temperature.

Thermostat status (heat mode only)
A flame symbol will be lit whenever the thermostat is calling for heat.

Thermostat status (cool mode only)
A snowflake symbol will be lit whenever the thermostat is calling for cooling. If this is seen to flash, the thermostat output is delayed for a short period to prevent compressor damage.

Low battery indication
A battery symbol will flash in the display when batteries require replacement. Batteries should be replaced within 15 days, after which the thermostat will turn off the load it is controlling.
When this happens “Of” will be displayed.

IMPORTANT: alkaline batteries must be used.
Alkaline Batteries Used

RET B-LS model only
Model Only
This model is fitted with an Auto/Off switch.

When the switch is set in “I” position the thermostat controls at the temperature set by the setting dial.

When set to “O” the thermostat output is turned off and “Of” is displayed.

RET B-NSB model only
Model Only
This model is fitted with a Day/Night switch.
When the switch is set to the “Sun Symbol”, the thermostat controls at the temperature set by the setting dial.

When set to the “Moon symbol”, the thermostat controls at 4°C below the temperature set by the setting dial.

NOTE: if used to control cooling, thermostat controls 4°C higher, with switch in MOON position.

www.danfoss.com/Business Areas/Heating

This product complies with the following EC Directives:
Electro-Magnetic Compatibility Directive.
(EMC) (891336/EEC), (92\31\EEC)
Low Voltage Directive.
(LVD) (73\23\EEC), (93/68/EEC)
CE Icon

Company Logo

Documents / Resources

Danfoss RET Series Electronic Dial Setting Thermostat with LCD Display [pdf] Installation Guide
RET B RF, RET B-LS RF, RET B-NSB RF, RET Series Electronic Dial Setting Thermostat with LCD Display, Electronic Dial Setting Thermostat with LCD Display, Dial Setting Thermostat with LCD Display, Thermostat with LCD Display, LCD Display

References

Leave a comment

Your email address will not be published. Required fields are marked *