Danfoss RET Series Electronic Dial Setting Thermostat tare da LCD Nuni Jagoran Shigarwa
Umarnin Shigarwa
Siffofin | RET B (RF) / RET B-LS (RF) / RET B-NSB (RF) |
Ƙimar lamba | 10 – 230 Vac, 3 (1) (excl. North America) |
Contact rating (N.America) | 10 – 24 Vac, 50/60Hz, 3(1)A |
Daidaiton Zazzabi | ±1°C |
Nau'in Tuntuɓi | SPDT Type 1B |
Mitar watsawa | 433.92 MHz (RF models) |
Kewayon watsawa | 30m max (RF models) |
Tushen wutan lantarki | 2 x AA/MN1500 alkaline batteries |
Sarrafa Gurbacewar Halin | Digiri 2 |
Tasirin Tasirin Voltage | 2.5 kV |
An tsara don saduwa | BS EN 60730-2-9 (EN 300220 for RF) |
Gwajin Matsayin Ƙwallo | 75°C |
Yanayin Zazzabi | 5-30 ° C |
Girma (mm) | 85 fadi x 86 high x 42 zurfi |
Important note RF products: Ensure that there are no large metal objects, such as boiler cases or other large appliances, in line of sight between the transmitter and receiver as these will prevent communication between thermostat and receiver.
Yin hawa
Gyara a tsayin 1.5m kusa da bene, nesa da zane-zane ko tushen zafi kamar radiators, buɗe wuta ko hasken rana kai tsaye.
Wiring (not RF models)
DUMI-DUMINSU
DIL canza saitunan
Slide the DIL switches to the settings required (see below)
Zabin dumama
Zaɓin sanyaya
KASHE/KASHE boiler switches ON when below set temperature and OFF when above
CHRONO Siffar ceton makamashi wanda ke kona tukunyar jirgi a lokaci-lokaci don kula da saita zafin jiki, cimma yanayin yanayi na yau da kullun ga mai amfani.
- amfani Zagaye 6 for radiator systems
- amfani Zagaye 3 for underfloor heating
Kulle & Iyakance
Receiver Wiring (RF only)
RX1 & RX2
RX3
Lura: 1) For mains voltage operated systems, link terminal 2 to mains live supply 2) Power supply to unit must not be switched by timeswitch
Commissioning (RF only)
Idan an kawo ma'aunin zafin jiki da mai karɓa tare a cikin fakitin hade, an haɗa raka'a a cikin masana'anta kuma ba a buƙatar ƙaddamarwa (RX1 kawai).
Step 1 RET B-RF
Position the setting dial to number 1. Remove dial, press & hold LEARN button for 3 seconds (located under setting dial).
Do not replace the setting dial yet
NOTE: Thermostat now transmits signal continuously for 5 mins.
Mataki na 2 RX1
Latsa ka riƙe maɓallai PROG kuma CH1 until green light flashes.
Step 3 RX2/RX3
For RX2 or RX3 repeat steps 1 and 2 for each thermostat and channel, leaving at least 5 mins between the commissioning of each thermostat.
Step 4 RET B-RF
To replace the thermostat setting dial, position the dial to number 1.
Umarni
Menene zafin jiki na daki?
an explanation for householders. A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Juya thermostat ɗaki zuwa wuri mafi girma ba zai sa ɗakin yayi zafi da sauri ba. Yaya sauri ɗakin zafi ya dogara da ƙirar tsarin dumama, don tsohonample, girman tukunyar jirgi da radiators.
Hakanan saitin baya tasiri yadda saurin ɗakin yake sanyaya. Juya zafin dakin zuwa ƙananan saiti zai haifar da sarrafa daki a ƙananan zafin jiki, kuma yana adana kuzari.
Tsarin dumama ba zai yi aiki ba idan sauyawar lokaci ko mai shirye-shirye ya kashe shi.
The way to set and use your room thermostat is to find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18°C-and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
Idan tsarin dumama gidan ruwa tukunyar jirgi ne tare da radiators, yawanci za'a iya samun thermostat ɗaki ɗaya don sarrafa gidan gaba ɗaya. Amma zaku iya samun yanayin zafi daban daban a cikin ɗakunan mutum ta hanyar sanya bawul din zafin jiki na thermostatic (TRVs) akan ɗumbin radiators. Idan baku da TRVs, yakamata ku zaɓi zazzabi wanda zai dace da gidan gaba ɗaya. Idan kuna da TRVs, zaku iya zaɓar saiti mafi girma kaɗan don tabbatar da cewa koda ɗakin da yafi sanyi shine mai kyau, sa'annan ku hana kowane zafi fiye da kima a wasu ɗakunan ta hanyar daidaita TRVs.
Na'urar sanyaya ɗaki tana buƙatar iskar iska kyauta don sanin zafin jiki, don haka dole ba a rufe su da labule ko kayan daki sun toshe su. Wutar lantarki da ke kusa, talabijin, bango ko tebur lamps na iya hana thermostat yin aiki da kyau.
Umarnin mai amfani
Nunawa
The LCD displays actual room temperature until the setting dial is moved.
Saita yanayin zafi
Turn setting dial to required temperature. The selected temperature will walƙiya in the LCD to signify it is showing saita zafin jiki.
After a short period the display stops flashing and shows actual room temperature.
Thermostat status (heat mode only)
Za a kunna alamar harshen wuta a duk lokacin da ma'aunin zafi da sanyio ke kiran zafi.
Thermostat status (cool mode only)
A snowflake symbol will be lit whenever the thermostat is calling for cooling. If this is seen to flash, the thermostat output is delayed for a short period to prevent compressor damage.
Alamar ƙarancin baturi
A battery symbol will flash in the display when batteries require replacement. Batteries should be replaced within 15 days, after which the thermostat will turn off the load it is controlling.
When this happens “Of” will be displayed.
MUHIMMANCI: alkaline batteries must be used.
RET B-LS model only
This model is fitted with an Auto/Off switch.
When the switch is set in “I” position the thermostat controls at the temperature set by the setting dial.
When set to “O” the thermostat output is turned off and “Of” is displayed.
RET B-NSB model only
This model is fitted with a Canjin Rana/Dare.
When the switch is set to the “Sun Symbol”, the thermostat controls at the temperature set by the setting dial.
When set to the “Moon symbol”, the thermostat controls at 4°C below the temperature set by the setting dial.
NOTE: if used to control cooling, thermostat controls 4°C higher, with switch in MOON position.
www.danfoss.com/Business Areas/Heating
Wannan samfurin ya bi umarnin EC masu zuwa:
Umarnin Haɗin Haɗin Electro-Magnetic.
(EMC) (891336/EEC), (92\31\EEC)
Ƙananan Voltage Umurni.
(LVD) (73\23\EEC), (93/68/EEC)
Takardu / Albarkatu
![]() |
Danfoss RET Series Electronic Dial Setting Thermostat with LCD Display [pdf] Jagoran Shigarwa RET B RF, RET B-LS RF, RET B-NSB RF, RET Series Electronic Dial Setting Thermostat with LCD Display, Electronic Dial Setting Thermostat with LCD Display, Dial Setting Thermostat with LCD Display, Thermostat with LCD Display, LCD Display |