CSM SBM_I open HV Split Breakout Module
Specifications
- Product Name: HV Split Breakout Module (SBM_I open)
- Application: High-voltage applications
- Safety Certification: Certified for high-voltage use
- Manufacturer: CSM GmbH
Product Usage Instructions
Safety Instructions
Before using the HV Split Breakout Module (SBM_I open), it is crucial to follow the safety guidelines provided:
- Only use qualified and trained personnel for handling and installation.
- Ensure the device is de-energized before mounting.
- Use appropriate mounting materials for secure installation.
- Monitor temperatures to prevent overheating.
- Wear safety gloves when handling the module, especially if it has been operating in a high-temperature environment.
Installation
- Ensure that the HV SBM_I open is de-energized before mounting.
- Follow the relevant installation instructions provided in the user guide.
- Securely fasten the module using suitable mounting materials like screws, nuts, and cable ties.
Maintenance
To maintain operational safety:
- Perform an isolation test in accordance with EN 61010 at least once per year.
- Always read and understand the documentation provided before initial operation.
- Contact CSM GmbH for any further questions or clarifications.
FAQ
- Q: How often should the isolation test be performed?
A: The isolation test should be conducted at least once per year in accordance with EN 61010. - Q: What should be done if the device heats up significantly during operation?
A: Reduce or interrupt the current flow through the shunt to prevent further temperature increase. Always monitor temperatures to avoid exceeding threshold values.
“`
Safety Instructions
HV Split Breakout Module (SBM_I open)
General safety instructions
Please observe the following safety instructions as well as the safety-specific information in the accompanying technical documentation.
WARNING! | |
![]() |
HV Split Breakout Modules of type HV SBM_I open are used in high-voltage applications.
Improper use may result in life-threatening electrical shocks.
|
WARNING! | |
![]()
|
Improper mounting involves the risk of life-threatening electric shocks.
The following details have to be observed for high-voltage-safe mounting:
|
WARNING! | |
![]() |
If the high-voltage power cables or busbars are not de-energized, there is a risk of accidentally touching non-insulated contacts at high-voltage potential.
If the device is not de-energized, there is a risk of life-threatening electrical shocks!
|
WARNING! | |
![]()
|
The connection cable between HV SBM_I open and HV Split Acquisition Module (HV SAM) is equipped with an HV connector on the measurement module side.
If the HV connector is not plugged in, there is a risk of life-threatening electrical shocks!
|
WARNING! | |
![]()
|
The internal temperature of the HV SBM_I open must not exceed +120 °C. As soon as the tem- perature of the shunt exceeds this value, the HV SAM measurement module sends the error code “0x8001” instead of the measured values for U and I. The user usually does not see this error code but the error message “THERMAL_OVERLOAD” that has been generated from the DBC or A2L file. This data is sent until the temperature of the shunt drops below +115 °C again.
Exceeding the specified temperature impairs the operational safety of the HV SBM_I open. There are risks including life-threatening electrical shocks and fire hazards.
|
CAUTION! | ||
|
The HV SBM_I open can heat up considerably if it is operated in a specific working environment (e.g. engine compartment). The shunt can also heat up considerably during operation under high load.
Touching the surface of the shunt may cause serious burns.
|
![]()
|
- Only use qualified and trained personnel for handling HV Split Breakout Modules.
- Make sure that HV Split Breakout Modules are only operated within an operating temperature range of -40 °C to +120 °C and at a relative humidity of max. 95 % (non-condensing).
- To ensure operational safety, an isolation test in accordance with the latest edition of EN 61010 has to be performed at least once per year.
- The entire documentation that has been delivered with the HV Split Breakout Modules has to be read thoroughly before initial operation. The operating personnel has to be instructed accordingly. Please contact CSM GmbH with any further questions.
Our company is certified.
www.tuv-sud.com/ms-cert
Raiffeisenstr. 36 • 70794 Filderstadt • Germany
+49 711 77 96 40 sales@csm.de www.csm.de
All trademarks mentioned are property of their respective owners. This document is subject to change without notice.
Copyright © 2024 CSM Computer-Systeme-Messtechnik GmbH
HV_SBM_open_SI_0110_EN_Serie 2024-08-20
Documents / Resources
![]() |
CSM SBM_I open HV Split Breakout Module [pdf] Owner's Manual HV SBM_I open, SBM_I open HV Split Breakout Module, SBM_I open, HV Split Breakout Module, Split Breakout Module, Breakout Module, Module |