Modul Antarmuka Utas SOLITY MT-100C
Fitur
Solity's MT-100C minangka produk papan antarmuka / aksesori sing nggunakake komunikasi Utas Nirkabel. MT-100C dirancang kanggo gampang ngetrapake IoT kanthi cara sing bisa dipasang ing kunci lawang dhasar.
barang | Fitur |
MCU inti |
Cortex-M33, 78MHz @ Frekuensi operasi maksimum |
1536 KB @Flash, 256 KB @RAM | |
Secure Vault (Secure Boot, TRNG, Secure Key Management, etc…) | |
Nirkabel |
Materi non-FHSS |
-105 dBm @ Sensitivitas | |
Modulasi: GFSK | |
Kondisi Operasi |
1.3uA @ Mode Turu jero |
5mA @ RX Mode Saiki | |
Daya Output 19 mA @10dBm | |
160 mA @ 20dBm Daya Output | |
5 V @ Operasi Voltage | |
-25 °C nganti 85 °C / Opsional -40 °C nganti 105 °C | |
Sinyal I/O | VDDI, GND, UART TXD, UART RXD, RESET |
ukuran | 54.3 x 21.6 x 9.7 (T) mm |
Diagram Blok Sistem lan Operasi
Diagram Blok Sistem
Katrangan Operasi
Vcc lan Internal SW Regulator
Input Vcc minangka input menyang regulator sw. Regulator SW ngasilake vol pancettage (3.2V~3.4V) kanggo nyuplai daya menyang MT-100C.
MT-100C Reset
Nalika ngganti input saka NRST saka Dhuwur kanggo Low, MT-100C direset, lan nalika ngganti input saka Low kanggo Dhuwur, MT-100C boots lan mbukak program.
MT-100C Paring
Yen pangguna pengin nyambungake MT-100C anyar menyang Controller / Hub, penet terus tombol pasangan luwih saka 7 detik. Sawise 7 detik, aplikasi seluler bisa nemokake piranti iki (MT-100C) liwat Utas , lan pangguna bisa nerusake proses pasangan.
Peta Pin Konektor Eksternal lan Katrangan Fungsi
Nomer PIN | Jeneng Pin | Arah Sinyal | Katrangan |
1 | USR_TXD | Output | Sinyal Transmisi UART |
2 | USR_RXD | Input | UART Nampa Sinyal |
3 | NC | Ora Ana Sambungan | |
4 | GND | Lemah Daya | |
5 | VDDI | Daya Input | Input Daya Opsional.
Yen input VBAT ora digunakake, iku vol konstan externaltage input daya. |
6 | GND | Lemah Daya | |
7 | NRST | Input | Sinyal reset kurang aktif. |
8 | NC | Ora Ana Sambungan | |
9 | NC | Ora Ana Sambungan | |
10 | NC | Ora Ana Sambungan | |
11 | NC | Ora Ana Sambungan | |
12 | GND | Lemah Daya | |
13 | VDDI | Daya Input | Padha karo PIN 5 |
14 | VBAT | Daya Input | Daya baterei antarane 4.7 ~ 6.4V. |
15 | NC | Ora Ana Sambungan | |
16 | NC | Ora Ana Sambungan |
Karakteristik Operasi
Ratings maksimum listrik
Cathetan: Tekanan sing ngluwihi Rating Maksimum bisa ngrusak piranti
Paramèter | Min | Maks | Unit |
VBAT (Input Daya DC) | -0.3 | 12 | V |
VDDI (Opsional DC Power Input) | -0.3 | 3.8V | V |
Saiki saben pin I / O | – | 50 | mA |
Cathetan: Saiki kanggo kabeh pin I / O diwatesi maksimal 200mA
Kahanan Operasi sing Disaranake Listrik
Paramèter | Min | Maks | Unit |
VBAT (Sumber Daya DC) | 4.7 | 6.4 | V |
VIH (High-Level Input Voltage) | 1.71V | 3.8V | V |
VIL (Low-Level Input Voltage) | 0V | 0.3V | V |
Kerentanan ESD
Paramèter | Min | Maks | Unit |
HBM (Model Badan Manungsa) | – | 2,000 | V |
MM (Mode Mesin) | – | 200 | V |
Saluran Komunikasi
Saluran | Frekuensi [MHz] | |
11 | 2405 | |
12 | 2410 | |
13 | 2415 | |
14 | 2420 | |
15 | 2425 | |
16 | 2430 | |
17 | 2435 | |
18 | 2440 | |
19 | 2445 | |
20 | 2450 | |
21 | 2455 | |
22 | 2460 | |
23 | 2465 | |
24 | 2470 | |
25 | 2475 | |
26 | 2480 |
Informasi FCC kanggo pangguna
Peralatan iki wis dites lan ketemu kanggo tundhuk karo watesan kanggo piranti digital Kelas B, miturut Part 15 saka Aturan FCC. Watesan kasebut dirancang kanggo menehi pangayoman sing cukup marang gangguan sing mbebayani ing instalasi omah. Peralatan iki ngasilake, nggunakake lan bisa mancarake energi frekuensi radio lan, yen ora dipasang lan digunakake miturut pandhuane, bisa nyebabake gangguan sing mbebayani kanggo komunikasi radio. Nanging, ora ana jaminan manawa gangguan ora bakal kedadeyan ing instalasi tartamtu. Yen peralatan iki nyebabake gangguan sing mbebayani kanggo resepsi radio utawa televisi, sing bisa ditemtokake kanthi mateni lan nguripake peralatan kasebut, pangguna dianjurake kanggo nyoba mbenerake gangguan kasebut kanthi salah sawijining langkah ing ngisor iki:
- Reorient utawa pindhah antena panampa.
- Tambah pamisahan antarane peralatan lan panrima.
- Sambungake peralatan menyang stopkontak ing sirkuit beda saka sing panrima disambungake.
- Hubungi dealer utawa teknisi radio/TV sing berpengalaman kanggo njaluk bantuan.
Ati-ati
Modifikasi sing ora disetujoni kanthi jelas dening pihak sing tanggung jawab kanggo kepatuhan bisa ngilangi wewenang pangguna kanggo ngoperasikake peralatan kasebut.
Informasi Kepatuhan FCC: Piranti iki tundhuk karo Part 15 saka Aturan FCC. Operasi tundhuk karo rong kondisi ing ngisor iki: (1) Piranti iki bisa uga ora nyebabake gangguan sing mbebayani, lan (2) piranti iki kudu nampa gangguan sing ditampa, kalebu gangguan sing bisa nyebabake operasi sing ora dikarepake.
RSS-GEN Bagean
Piranti iki tundhuk karo standar RSS sing dibebasake lisensi Industry Canada. Operasi tundhuk karo rong kondisi ing ngisor iki: (1) piranti iki ora bisa nyebabake gangguan, lan (2) piranti iki kudu nampa gangguan apa wae, kalebu gangguan sing bisa nyebabake operasi piranti sing ora dikarepake.
Dokumen / Sumber Daya
![]() |