PPI FrizCon Deep Freezer Controller karo Tampilan Graphic
PARAMETER OPERATOR
OPERATOR PARAMETER | |
Paramèter | Setelan (Nilai Default) |
Filter Repair Ack >> | Ya Ora
(Default: Ora) |
Cascade HPLP Ack >> Kabinet HPLP Ack >> | Ya Ora
(Default: Ora) |
Ctrl Setpoint >> | Setpoint Low Limit nganti Setpoint High Limit
(Default: -80.0) |
Ctrl Lo Penyimpangan >> | 0.2 nganti 99.9
(Default: 2.0) |
Ctrl Hi Deviation >> | 0.2 nganti 99.9
(Default: 2.0) |
Ctrl Zero Offset >> | -50.0 nganti 50.0
(Default: 0.0) |
Filter Zero Offset >> utawa
Coil Zero Offset >> |
-50.0 nganti 50.0
(Default: 0.0) |
Defrost Start >> Defrost Stop >> | Mulai Stop
(Default: NA) |
Ganti Sandi >> | 1 nganti 100
(Default: 0) |
KANGGO | PARAMETER SERIAL |
Paramèter | Setelan (Nilai Default) |
ID Piranti >> | 1 nganti 127
(Default: 1) |
Baud Rate >> | 2400, 4800,
9600, 19200, 38400, 57600 (Default: 9600) |
Paritas >> | Ora Ana Ganjil
(Default: Malah) |
Nulis Serial >> | Ora Ya
(Default: Ora) |
KANGGO KONTROL | |
Paramèter | Setelan (Nilai Default) |
Setpoint Lo Limit >> | -100.0 nganti Setpoint Batas HI (Default: -100.0) |
Setpoint Hi Limit >> | 'single' or 'Single with Filter' Mode Kompresor
Setpoint LO Limit nganti 100.0 'Cascade' utawa 'Cascade with Filter' utawa 'Cascade with Coil' Compressor Mode Setpoint LO Limit kanggo Cascade SP (Default: -10.0) |
Comp On Offset >> | 0.1 nganti 99.9
(Default: 1.0) |
Comp Offset >> | 0.1 nganti 99.9
(Default: 0.1) |
PABRIK PARAMETER ALARM | |
Paramèter | Setelan (Nilai Default) |
Low Alarm Hyst >> | 0.1 nganti 99.9
(Default: 0.2) |
Low Alarm Nyandhet >> | Pateni Aktifake
(Default: Aktifake) |
High Alarm Hyst >> | 0.1 nganti 99.9
(Default: 0.2) |
Alarm Dhuwur Nyandhet >> | Pateni Aktifake
(Default: Aktifake) |
PABRIK OPERASI KOMPRESOR | |
Paramèter | Setelan (Nilai Default) |
Mode Operasi >> | Single Single karo Filter
Cascade Cascade karo Filter Cascade karo Coil (Default: Cascade with Coil) |
Cascade Sp >> | -70.0 nganti 10.0
(Default: -30.0) |
Off To On Delay >> | 0 nganti 1000 Detik (Default: 200 Detik) |
Ngalih Tundha >> | 0 nganti 1000 Detik (Default: 15 Detik) |
Cascade Comp Hyst >> | 1 nganti 50.0
(Default: 20) |
PABRIK OPERASI FILTER | |
Paramèter | Setelan (Nilai Default) |
Filter Alarm Sp >> | -100.0 nganti 100.0
(Default: 55.0) |
Filter Alarm Hyst >> | 0.1 nganti 99.9
(Default: 0.2) |
Filter Cut-off Sp >> | Weker SP nganti 100.0 (Default : 60.0) |
PABRIK OPERASI DEFROST | |
Paramèter | Setelan (Nilai Default) |
Operasi >> | Pateni Manual Otomatis
(Default: Pateni) |
Wektu Defrost [M:S] >> | 1 nganti 99.59 (Min:Detik) (Default: 5 Detik) |
defrost Interval [H:M] >> | 1 nganti 99.59 (Jam: Min) (Default: 8 Min) |
Paramèter | Setelan (Nilai Default) |
Ngalih Logika >> | Mbukak : Lawang Mbukak Tutup : Mbukak Lawang
(Default: Tutup: Lawang Mbukak) |
Lawang Alrm Dly (detik) >> | 0 nganti 1000 Detik (Default: 60 Detik) |
PABRIK CASCADE COMP HPLP
(Mung kasedhiya kanggo Mode Operasi Cascade) |
|
Paramèter | Setelan (Nilai Default) |
Aktifake >> | Ora Ya
(Default: Ora) |
Ngalih Logika >> | Bukak: HP-LP Tutup: HP-LP
(Default: Tutup: HP-LP) |
PABRIK | KABINET COMP HPLP |
Paramèter | Setelan (Nilai Default) |
Aktifake >> | Ora Ya
(Default: Ora) |
Ngalih Logika >> | Bukak: HP-LP Tutup: HP-LP
(Default: Tutup: HP-LP) |
PABRIK | PABRIK DEFAULT |
Paramèter | Setelan (Nilai Default) |
Setel menyang Default >> | Ora Ya
(Default: Ora) |
PABRIK SANDI | |
Paramèter | Setelan (Nilai Default) |
Ganti Sandi >> | 2000 nganti 2999
(Default: 321) |
PABRIK MUTU | |
Paramèter | Setelan (Nilai Default) |
Metu Mode Setup >> | Ora Ya
(Default: Ora) |
Tabel 1 | ||
Apa tegese | Range (Min. nganti Maks.) | Resolusi |
3-kawat, RTD Pt100 | -199.9 nganti 600.0°C | Tetep 0.1 ° C |
0 nganti 20mA DC saiki |
-199.9 kanggo 999.9 Unit |
didandani 0.1 unit |
4 nganti 20mA DC saiki | ||
0 kanggo 5.0V DC voltage | ||
0 kanggo 10.0V DC voltage | ||
1 kanggo 5.0V DC voltage |
LAPORAN PANEL FRONT
Operasi tombol
Indikasi kesalahan PV
Pesen | Jinis Kesalahan | sabab | ||
![]() |
Sensor mbukak | RTD Pt100 Sensor/Kabel Rusak/Mbukak | ||
![]() |
Over-range | Suhu ndhuwur Max. Range sing ditemtokake | ||
![]() |
Under-range | Suhu ngisor Min. Range sing ditemtokake |
SAMBUNGAN LISTRIK
MODE OPERASI CASCADE
* Kanggo informasi luwih lengkap waca User Manual
Mode Operasi Kompresor Cascade (karo Sensor Coil)
Mode Operasi Kompresor Cascade (tanpa Sensor Coil)
Manual singkat iki utamané dimaksudaké kanggo referensi cepet sambungan kabel lan searching parameter. Kanggo rincian liyane babagan operasi lan aplikasi; mangga log on www.ppiindia.net
101, Diamond Industrial Estate, Navghar, Vasai Road (E), Dist. Palghar – 401 210.
Sales : 8208199048 / 8208141446
Dhukungan: 07498799226 / 08767395333
E: sales@ppiindia.net,
support@ppiindia.net
Dokumen / Sumber Daya
![]() |
PPI FrizCon Deep Freezer Controller karo Tampilan Graphic [pdf] Instruksi Manual FrizCon, FrizCon Deep Freezer Controller karo Graphic Display, Deep Freezer Controller karo Graphic Display, Freezer Controller karo Graphic Display, Graphic Display |