Spesifikasi

  • Model: ITC-306T-WIFI
  • Jeneng merek: INKBIRD
  • Input: 120Vac 60Hz 10A/1200W MAX
  • Output: 120Vac 60Hz 10A/1200W (total two receptacles)
  • Pedhot tegese: Tipe 1B
  • Tingkat polusi: 2
  • Impuls sing dirating voltage: 1500v
  • Tumindak otomatis: 6000 siklus

Suhu Probe (opsional)

  • Type of temperature probe: R25°C=10KΩ±1%,
  • R0°C=26.74~27.83KΩ , B25/85°C=3435K±1%
  • Rentang kontrol suhu: -50°C~99.0°C/-58.0°F~210°F
  • Temperature measurement range: -50.0°C~120°C/-58.0°F~248°F
  • Temperature display accuracy:-0.1°C/°F(<100°C/°F),1°C/°F(<=100°C/°F)

Akurasi pangukuran suhu:

Range of Temperature(T) Celsius kesalahan Celsius Range saka Suhu (T) Fahrenheit Kesalahan Fahrenheit
-50℃≤T<10℃ ± 2 ℃ -58℉≤T<50℉ ± 3℉
10℃≤T<100℃ ± 1 ℃ 50℉≤T<212℉ ± 2℉
100℃≤T<120℃ ± 2 ℃ 176℉≤T<248℉ ± 3℉

Ambient

Ambient temperature: Room temperature
Lingkungan panyimpenan:
temperature: 0°C~60°C/32°F~140°F;
humidity: 20~80%RH (Unfrozen or condensation state)

Garansi
Controller: Two-year warranty
Temperature Probe: One-year warranty

Technical Assistance and Warranty

Bantuan Teknis
If you have any problems installing or using this controller, please refer to the instruction manual for guidance. If you require further assistance, please email us at
support@inkbird.com. We will reply within 24 hours, Monday to Saturday. Alternatively, you can visit our official websitus (www.inkbird.com) to find answers to common technical questions.

Garansi
INKBIRD TECH CO., LTD warrants this controller (one year for the temperature probe) against defects caused by INKBIRD’s workmanship or materials for two years (one year for the temperature probe) from the date of purchase, provided it is operated under normal conditions by the original purchaser (not transferable). This warranty is limited to the repair or replacement (at INKBIRD’s discretion) of all or part of the controller.

Panel Kontrol

INKBIRD-ITC-306T-WIFI-Temperature-Controller-1

  • ① PV: In the normal mode, it displays the current temperature; in the setting mode, it displays menu code.
  • ② SV: In the normal mode, it displays the temperature at which the heating is stopped; in the setting mode, it displays menu setting.
  • ③ Red indicator: ON-heating output is turned on; OFF-heating output is turned off.
  • ④⑤⑥ Set Key SET, Increase Key, Decrease WIFI Key: Please refer to“6.1 Button Instruc-tion” for more details.
  • ⑦ Output socket: Both sockets are only for heating.

Setelan APP INKBIRD

Ngundhuh APP
Telusuri tembung kunci "INKBIRD" ing Appstore utawa Google Play kanggo entuk app, utawa pindai kode QR ing ngisor iki langsung kanggo ndownload lan nginstal APP.

INKBIRD-ITC-306T-WIFI-Temperature-Controller-2

Masangake karo telpon sampeyan

  1. Bukak app, bakal njaluk sampeyan ndhaptar utawa mlebu akun ing APP. Pilih negara lan ketik Email kanggo ngrampungake registrasi. Banjur pencet tombol "Tambah Ngarep" kanggo nggawe omah sampeyan.INKBIRD-ITC-306T-WIFI-Temperature-Controller-3
  2. Tutul tombol "+" utawa "tambah piranti" ing kaca ngarep APP kanggo nambah piranti.
  3. Yen controller ing negara apa normal, sampeyan bisa dawa pencet INKBIRD-ITC-306T-WIFI-Temperature-Controller-4 2 seconds to reset the Wi-Fi. WIFI
    It will enter the Smartconfig configuration state by default. You can short press INKBIRD-ITC-306T-WIFI-Temperature-Controller-4 to switch the WIFI Smartconfig configuration state and the AP mode. If you change the Wi-Fi state, it will take about 5 seconds to display the corresponding LED symbol and state, because of the Wi-Fi module data processing.

Tambah piranti ing sambungan cepet:

  • Plug the device in the socket and make sure that the device is in Smartconfig.
  • Status konfigurasi (simbol LED sumunar, interval sumunar 250ms). Klik "Konfirmasi indikator kanthi cepet blink" banjur pilih jaringan Wi-Fi, ketik sandhi Wi-Fi, klik "konfirmasi" kanggo ngetik proses sambungan.
  • Piranti kasebut mung ndhukung router Wi-Fi 2.4GHz.

INKBIRD-ITC-306T-WIFI-Temperature-Controller-5

Tambah piranti ing mode AP:

  • Pasang piranti ing stopkontak lan priksa manawa piranti kasebut ing AP Konfigurasi Negara (simbol LED sumunar alon-alon, interval sumunar 1500ms).
  • Klik "Konfirmasi indikator alon-alon kedhip" banjur pilih jaringan Wi-Fi, ketik sandhi Wi-Fi, klik "konfirmasi" kanggo ngetik proses sambungan.
  • Press “Connect now” and it will go to your WLAN settings in your smartphone, select the “SmartLife-XXXX” to directly connect to the router without providing a password.
  • Bali menyang app kanggo ngetik antarmuka sambungan otomatis.

INKBIRD-ITC-306T-WIFI-Temperature-Controller-6

  • ④ Click “Done” after device is added successfully and enter into device controlling interface.
  • ⑤ In the temperature control mode, user can set control function via APP.

Mode Normal

INKBIRD-ITC-306T-WIFI-Temperature-Controller-7

INKBIRD-ITC-306T-WIFI-Temperature-Controller-8

Mode Timer

INKBIRD-ITC-306T-WIFI-Temperature-Controller-9

INKBIRD-ITC-306T-WIFI-Temperature-Controller-10

Instruksi Fungsi

Pandhuan Tombol

  1. Reset pabrik
    Hold the “ ” button to power on, the buzzer will beep once, and all parameters will restore to factory settings.
  2. Instruksi Tombol ing Mode Setelan
    When the controller is working normally, press SET key for 2 seconds to enter parameter setting mode. PV window displays the first menu code “TS1”, while SV window displays the setting value. Press the SET button to scroll down the menu and save the previous menu parameters, press the “INKBIRD-ITC-306T-WIFI-Temperature-Controller-4” WIFI or “INKBIRD-ITC-306T-WIFI-Temperature-Controller-11” button to change the current setting value. If there is no button operation within 30 seconds or long press the “SET” button for 2 seconds in the setting state, it will exit and save the setting state, then return to the normal working mode.

Menu Setelan Flow Chart

INKBIRD-ITC-306T-WIFI-Temperature-Controller-12

Setup Menu Instruksi

INKBIRD-ITC-306T-WIFI-Temperature-Controller-13

Nalika TR=1, fungsi mode wektu urip, setelan menu kaya ing ngisor iki.

INKBIRD-ITC-306T-WIFI-Temperature-Controller-14

Instruksi Fungsi Kontrol

  1. Instruksi Kontrol Suhu ing Mode Normal (TS1, DS1, TR=0)
    Nalika controller bisa digunakake biasane, jendhela PV nampilake suhu diukur, jendhela SV nampilake nilai pesawat suhu.
    When the measured temperature PV ≥ TS1 (Temperature Set Value1), the WORK indicator is off, the output sockets turn off; When the measured temperature PV ≤ TS1 (Tempera-ture Set Value1)-DS1 (Heating Differential Value 1), the WORK indicator is on, and the output sockets turn on.
    Kanggo example, TS1 = 25.0 ° C, DS1 = 3.0 ° C, nalika suhu diukur ≤ 22 ° C (TS1-DS1), soket output nguripake; nalika suhu diukur ≥ 25 ° C (TS1), soket output mati.
  2. Instruksi Kontrol Suhu ing Mode Timer (TS1, DS1, TR=1, TS2, DS2, TAH, TAM, TBH, TBM, CTH, CTM)
    Nalika TR=0, fungsi mode timer mati, paramèter TS2, DS2, TAH, TAM, TBH, TBM, CTH, CTM ora katon ing menu.
    Nalika TR=1, Mode Timer urip. Wektu A~Wektu B~Wektu A iku siklus, 24 jam.
    During Time A~Time B, the controller runs as TS1 (Temperature Set Value1) and DS1 (Heating Differential Value1); during Time B~Time A, the controller runs as TS1 (Temperature Set Value2) and DS1(Heating Differential Value2).
    Kanggo example: Set TS1=25, DS1=2, TR=1, TS2=18, DS2=2, TAH=8, TAM=30, TBH=18, TBM=00, CTH=9, CTM=30, CTH and CTM are the current time setting, the setting time is 9:30.
    Sajrone 8:30-18:00 (Wektu A ~ Wektu B), kontrol suhu antarane 22 ° C (TS1-DS1) ~ 25 ° C (TS1);
    Sajrone 18:00-8:30 (Wektu B ~ Wektu A), kontrol suhu antarane 16 ° C (TS2-DS2) ~ 18C (TS2).
  3. High/Low Temperature Alarm (AH,AL)
    When the measured temperature ≥ High Temperature Alarm (AH), it will alarm and turn off heating output. The PV window will display “AH” and the measured temperature at the 1Hz frequency alternately , buzzer will “Bi-Bi-Biii” when ALM=ON, until the measured temperature < AH, buzzer will be off and return to normal display and control. Or press any button to turn the buzzer alarm off;

When the measured temperature ≤ Low Temperature Alarm (AL), it will alarm. The PV window will display “AL” and the measured temperature at the 1Hz frequency alternately, buzzer will “Bi-Bi-Biii” when ALM=ON, until the temperature > AL, buzzer will be off and return to normal display and control. Or press any button to turn the buzzer alarm off.
Cathetan: The Low Temperature Alarm (AL) should be less than the High Temperature Alarm (AH). The high or low temperature alarm will be pushed to mobile APP and remind the user that the device is in alarm state.

Kalibrasi Suhu (CA)
Nalika ana panyimpangan antarane suhu diukur lan suhu nyata, fungsi kalibrasi suhu bisa digunakake kanggo calibrate Nilai diukur lan nggawe konsisten karo nilai standar, suhu kalibrasi = Nilai suhu diukur + Nilai kalibrasi.

Tampilan ing unit Fahrenheit utawa Celsius (C/F)
Opsional nyetel unit tampilan minangka Fahrenheit utawa Celsius. Unit suhu standar yaiku Fahrenheit. Yen perlu ditampilake ing Celsius, setel nilai CF minangka C.
Cathetan: When CF is changed, all setting values will be restored to the default setting and the buzzer will beep once.

Swara Buzzer ON/OFF Ing Weker Abnormal (ALM)
Pangguna bisa milih arep ngaktifake fungsi swara buzzer nalika weker ora normal ana miturut panggunaan nyata. Nalika milih ON, buzzer bakal muni, nalika milih OFF, buzzer bakal nutup swara nalika ana weker abnormal.

Kahanan kesalahan

  1. Kasalahan Probe
    The PV window show Er when the probe is not plugged in properly or there is short circuit inside the probe. When ALM=ON, the buzzer will kept beeping, the sound can be cut off by press any button.
  2. Kasalahan Wektu
    Nalika wektu ora normal, jendhela PV nuduhake Err. Nalika ALM=ON, buzzer bakal terus muni, swara bisa dipateni kanthi mencet tombol apa wae.
  3. Kasalahan Reset Wektu
    When TR=1, when the device is power-on again after power off, and when PV window alternately display the current temperature and TE at 1 Hertz frequency. If ALM=ON, the buzzer will go off every two seconds which mean the timer should be reset. You can press any button to stop the alarm, if long press for 2 seconds, it will enter to the setting menu and skip to CTH menu code, setting the CTH and CTM value then save the parameter, the device will back to normal operation; normal operation can also be restored by tapping the synchronization time via the app.

Kepiye cara ngatasi masalah umum ing panggunaan APP?

Status sabab bisa solusi awal
 

Gagal mlebu

Akun lan sandhi sing salah Ketik maneh sandhi lan konfirmasi
Server jaringan ing pangopènan Coba mengko mengko
 

 

 

Gagal Sambungan

Misoperation (Abaikan langkah penting) Konfirmasi langkah sing bener lan coba maneh
Sandi WiFi sing salah Plain-text input password
Kondisi jaringan sing ora apik Coba maneh utawa ganti lingkungan jaringan
Model telpon & versi sistem Ngalih menyang telpon liya lan coba maneh
Gagal Muat Data Server jaringan ing pangopènan Coba mengko mengko
 

APP Layar Ireng

Running app takes up too much memory Mbusak APP sing mlaku
Instalasi ora lengkap Busak instal Aplikasi INKBIRD lan instal maneh

Syarat FCC

Owah-owahan utawa modifikasi sing ora disetujoni kanthi jelas dening pihak sing tanggung jawab kanggo kepatuhan bisa ngilangi wewenang pangguna kanggo ngoperasikake peralatan kasebut.
Piranti iki tundhuk karo Part 15 saka Aturan FCC. Operasi tundhuk karo rong syarat ing ngisor iki:

(1) piranti iki bisa uga ora nimbulaké gangguan mbebayani, lan
(2) piranti iki kudu nampa gangguan sing ditampa, kalebu gangguan sing bisa nyebabake operasi sing ora dikarepake.

Cathetan: Peralatan iki wis dites lan ketemu tundhuk karo watesan kanggo piranti digital Kelas B, miturut Part 15 saka Aturan FCC. Watesan kasebut dirancang kanggo menehi pangayoman sing cukup marang gangguan sing mbebayani ing instalasi omah. Peralatan iki ngasilake, nggunakake, lan bisa mancarake energi frekuensi radio, lan yen ora dipasang lan digunakake miturut pandhuane, bisa nyebabake gangguan sing mbebayani kanggo komunikasi radio. Nanging, ora ana jaminan manawa gangguan ora bakal kedadeyan ing instalasi tartamtu. Yen peralatan iki nyebabake gangguan sing mbebayani kanggo panrima radio utawa televisi, sing bisa ditemtokake kanthi mateni lan nguripake peralatan kasebut, pangguna dianjurake kanggo nyoba mbenerake gangguan kasebut kanthi siji utawa luwih saka langkah-langkah ing ngisor iki:

  • Reorient utawa pindhah antena panampa.
  • Tambah pamisahan antarane peralatan lan panrima.
  • Sambungake peralatan menyang stopkontak ing sirkuit beda saka sing panrima disambungake.
  • Hubungi dealer utawa teknisi radio/TV sing berpengalaman kanggo njaluk bantuan.

Peralatan iki tundhuk karo watesan paparan radiasi FCC sing ditemtokake kanggo lingkungan sing ora dikendhaleni. Peralatan iki kudu dipasang lan dioperasikake kanthi jarak minimal 20cm antarane radiator lan awak. Pemancar iki ora kena dipasang utawa dioperasikake bebarengan karo antena utawa pemancar liyane.

IC Warning
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation,  Science and Economic Development Canada’s licence-exempt RSS(s).   Operation is subject to the following two conditions:

  1. Piranti iki bisa uga ora nyebabake gangguan.
  2. Piranti iki kudu nampa gangguan apa wae, kalebu gangguan sing bisa nyebabake operasi piranti sing ora dikarepake.

Piranti kasebut nduweni pengecualian saka watesan evaluasi rutin ing bagean 2.5 RSS 102 lan tundhuk karo paparan RF RSS-102, pangguna bisa entuk informasi Kanada babagan paparan lan kepatuhan RF.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Peralatan iki kudu dipasang lan dioperasikake kanthi jarak minimal 20 sentimeter ing antarane radiator lan awak.

Shenzhen Inkbird Technology Co., Ltd.
support@inkbird.com

Pengirim: Shenzhen Inkbird Technology Co., Ltd.
Alamat Kantor: Room 1803, Guowei Building, No.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China Manufacturer: Shenzhen Lerway Technology Co., Ltd.
Alamat Pabrik: Kamar 501, Gedung 138, No. 71, Yiqing Road, Xianhu Community, Liantang Street, Luohu District, Shenzhen, China

Dokumen / Sumber Daya

INKBIRD ITC-306T WIFI Temperature Controller [pdf] Pandhuan pangguna
ITC-306T, ITC-306T WIFI Temperature Controller, WIFI Temperature Controller, Temperature Controller, Controller

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *