Specification
- Model: ITC-306T-WIFI
- Brand name: INKBIRD
- Input: 120Vac 60Hz 10A/1200W MAX
- Output: 120Vac 60Hz 10A/1200W (total two receptacles)
- Disconnection means: Type 1B
- Pollution degree: 2
- Rated impulse voltage: 1500V
- Automatic action: 6000 cycles
Temperature Probe (optional)
- Type of temperature probe: R25°C=10KΩ±1%,
- R0°C=26.74~27.83KΩ , B25/85°C=3435K±1%
- Temperature control range: -50°C~99.0°C/-58.0°F~210°F
- Temperature measurement range: -50.0°C~120°C/-58.0°F~248°F
- Temperature display accuracy:-0.1°C/°F(<100°C/°F),1°C/°F(<=100°C/°F)
Temperature measurement accuracy:
Range of Temperature(T) Celsius | Celsius Error | Range of Temperature(T) Fahrenheit | Fahrenheit Error |
-50℃≤T<10℃ | ±2℃ | -58℉≤T<50℉ | ±3℉ |
10℃≤T<100℃ | ±1℃ | 50℉≤T<212℉ | ±2℉ |
100℃≤T<120℃ | ±2℃ | 176℉≤T<248℉ | ±3℉ |
Ambient
Ambient temperature: Room temperature
Storage environment:
temperature: 0°C~60°C/32°F~140°F;
humidity: 20~80%RH (Unfrozen or condensation state)
Warranty
Controller: Two-year warranty
Temperature Probe: One-year warranty
Technical Assistance and Warranty
Technical Assistance
If you have any problems installing or using this controller, please refer to the instruction manual for guidance. If you require further assistance, please email us at
support@inkbird.com. We will reply within 24 hours, Monday to Saturday. Alternatively, you can visit our official website (www.inkbird.com) to find answers to common technical questions.
Warranty
INKBIRD TECH CO., LTD warrants this controller (one year for the temperature probe) against defects caused by INKBIRD’s workmanship or materials for two years (one year for the temperature probe) from the date of purchase, provided it is operated under normal conditions by the original purchaser (not transferable). This warranty is limited to the repair or replacement (at INKBIRD’s discretion) of all or part of the controller.
Control Panel
- ① PV: In the normal mode, it displays the current temperature; in the setting mode, it displays menu code.
- ② SV: In the normal mode, it displays the temperature at which the heating is stopped; in the setting mode, it displays menu setting.
- ③ Red indicator: ON-heating output is turned on; OFF-heating output is turned off.
- ④⑤⑥ Set Key SET, Increase Key, Decrease WIFI Key: Please refer to“6.1 Button Instruc-tion” for more details.
- ⑦ Output socket: Both sockets are only for heating.
INKBIRD APP Setting
Download the APP
Search the keyword “INKBIRD” in Appstore or Google Play to get the app, or scan the following QR code directly to download and install the APP.
Pair with your phone
- Open the app, it will ask you to register or log in your account on the APP. Select the country and enter Email to finish the registration. Then press “Add Home” button to create your home.
- Tap “+” or “add device” button in home page of the APP to add the device.
- If the controller is in the normal working state, you can long press
2 seconds to reset the Wi-Fi. WIFI
It will enter the Smartconfig configuration state by default. You can short pressto switch the WIFI Smartconfig configuration state and the AP mode. If you change the Wi-Fi state, it will take about 5 seconds to display the corresponding LED symbol and state, because of the Wi-Fi module data processing.
Add device in quick connection:
- Plug the device in the socket and make sure that the device is in Smartconfig.
- Configuration state (the LED symbol is flashing, interval flashing 250ms). Click “Confirm indicator rapidly blink” and then select Wi-Fi network, enter Wi-Fi password, click “confirm” to enter connection process.
- The device only supports 2.4GHz Wi-Fi router.
Add device in AP mode:
- Plug the device in the socket and make sure that the device is in the AP Configuration State (the LED symbol is flashing slowly, interval flashing 1500ms).
- Click “Confirm indicator slowly blink” and then select Wi-Fi network, enter Wi-Fi password, click “confirm” to enter connection process.
- Press “Connect now” and it will go to your WLAN settings in your smartphone, select the “SmartLife-XXXX” to directly connect to the router without providing a password.
- Go back to app to enter into the automatic connection interface.
- ④ Click “Done” after device is added successfully and enter into device controlling interface.
- ⑤ In the temperature control mode, user can set control function via APP.
Normal Mode
Timer Mode
Function Instruction
Button Instruction
- Factory Reset
Hold the “ ” button to power on, the buzzer will beep once, and all parameters will restore to factory settings. - Button Instruction in the Setting Mode
When the controller is working normally, press SET key for 2 seconds to enter parameter setting mode. PV window displays the first menu code “TS1”, while SV window displays the setting value. Press the SET button to scroll down the menu and save the previous menu parameters, press the “” WIFI or “
” button to change the current setting value. If there is no button operation within 30 seconds or long press the “SET” button for 2 seconds in the setting state, it will exit and save the setting state, then return to the normal working mode.
Menu Setting Flow Chart
Setup Menu Instruction
When TR=1, the time mode function is on, the menu settings are as follows.
Control Function Instruction
- Temperature Control Instruction in the Normal Mode (TS1, DS1, TR=0)
When the controller is working normally, PV window displays the measured temperature, SV window displays temperature set value.
When the measured temperature PV ≥ TS1 (Temperature Set Value1), the WORK indicator is off, the output sockets turn off; When the measured temperature PV ≤ TS1 (Tempera-ture Set Value1)-DS1 (Heating Differential Value 1), the WORK indicator is on, and the output sockets turn on.
For example, TS1=25.0°C, DS1=3.0°C, when the measured temperature ≤ 22°C (TS1-DS1), the output sockets turn on; when the measured temperature ≥ 25°C (TS1), the output sockets turn off. - Temperature Control Instruction in the Timer Mode (TS1, DS1, TR=1 , TS2, DS2, TAH, TAM, TBH, TBM, CTH, CTM)
When TR=0, the timer mode function is off, the parameters TS2, DS2, TAH, TAM, TBH, TBM, CTH, CTM don’t show up in the menu.
When TR=1, the Timer Mode is on. Time A~Time B~Time A is a cycle, 24 hours.
During Time A~Time B, the controller runs as TS1 (Temperature Set Value1) and DS1 (Heating Differential Value1); during Time B~Time A, the controller runs as TS1 (Temperature Set Value2) and DS1(Heating Differential Value2).
For example: Set TS1=25, DS1=2, TR=1, TS2=18, DS2=2, TAH=8, TAM=30, TBH=18, TBM=00, CTH=9, CTM=30, CTH and CTM are the current time setting, the setting time is 9:30.
During 8:30-18:00 (Time A~Time B), the temperature controls between 22°C (TS1-DS1)~25°C (TS1);
During 18:00-8:30 (Time B~Time A), the temperature controls between 16°C (TS2-DS2)~18C (TS2). - High/Low Temperature Alarm (AH,AL)
When the measured temperature ≥ High Temperature Alarm (AH), it will alarm and turn off heating output. The PV window will display “AH” and the measured temperature at the 1Hz frequency alternately , buzzer will “Bi-Bi-Biii” when ALM=ON, until the measured temperature < AH, buzzer will be off and return to normal display and control. Or press any button to turn the buzzer alarm off;
When the measured temperature ≤ Low Temperature Alarm (AL), it will alarm. The PV window will display “AL” and the measured temperature at the 1Hz frequency alternately, buzzer will “Bi-Bi-Biii” when ALM=ON, until the temperature > AL, buzzer will be off and return to normal display and control. Or press any button to turn the buzzer alarm off.
Note: The Low Temperature Alarm (AL) should be less than the High Temperature Alarm (AH). The high or low temperature alarm will be pushed to mobile APP and remind the user that the device is in alarm state.
Temperature Calibration (CA)
When there is deviation between measured temperature and actual temperature, the temperature calibration function can be used to calibrate the measured value and make it consistent with the standard value, the calibrated temperature = the measured temperature value + the calibration value.
Display in Fahrenheit or Celsius unit (C/F)
Optional setting the display unit as Fahrenheit or Celsius. The default temperature unit is Fahrenheit. In need of displaying in Celsius , set CF value as C.
Note: When CF is changed, all setting values will be restored to the default setting and the buzzer will beep once.
Buzzer Sound ON/OFF Under Abnormal Alarm (ALM)
Users can choose whether to turn on the sound function of the buzzer when an abnormal alarm occurs according to actual use. When choosing ON, the buzzer will make a sound, when choosing OFF, the buzzer will close the sound when there is abnormal alarm.
Error Situation
- Probe Error
The PV window show Er when the probe is not plugged in properly or there is short circuit inside the probe. When ALM=ON, the buzzer will kept beeping, the sound can be cut off by press any button. - Time Error
When time abnormal, PV window indicate Err. When ALM=ON, the buzzer will kept beeping, the sound can be cut off by press any button. - Time Reset Error
When TR=1, when the device is power-on again after power off, and when PV window alternately display the current temperature and TE at 1 Hertz frequency. If ALM=ON, the buzzer will go off every two seconds which mean the timer should be reset. You can press any button to stop the alarm, if long press for 2 seconds, it will enter to the setting menu and skip to CTH menu code, setting the CTH and CTM value then save the parameter, the device will back to normal operation; normal operation can also be restored by tapping the synchronization time via the app.
How to deal with common problems in APP use?
Status | possible cause | preliminary solution |
Login Failure |
Incorrect account and password | Re-type password and confirm |
Network server under maintenance | Try again later | |
Connection Failure |
Misoperation (Ignore important steps) | Confirm the correct steps and try again |
Incorrect WiFi password | Plain-text input password | |
Poor network condition | Try again or change network environment | |
Phone model & system version | Switch to another phone and try again | |
Data Load Failure | Network server under maintenance | Try again later |
APP Black Screen |
Running app takes up too much memory | Clear the running APP |
Incomplete installation | Uninstall INKBIRD App and re-install |
FCC Requirement
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
IC Warning
This device contains licence-exempt transmitter(s)/ receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
Shenzhen Inkbird Technology Co., Ltd.
support@inkbird.com
Consignor: Shenzhen Inkbird Technology Co., Ltd.
Office Address: Room 1803, Guowei Building, No.68 Guowei Road, Xianhu Community, Liantang, Luohu District, Shenzhen, China Manufacturer: Shenzhen Lerway Technology Co., Ltd.
Factory Address: Room 501, Building 138, No. 71, Yiqing Road, Xianhu Community, Liantang Street, Luohu District, Shenzhen, China
Documents / Resources
![]() |
INKBIRD ITC-306T WIFI Temperature Controller [pdf] User Guide ITC-306T, ITC-306T WIFI Temperature Controller, WIFI Temperature Controller, Temperature Controller, Controller |