Edge-corE-logo

Edge-corE AIS800-32D 800 Gigabit AI lan Data Center Ethernet Ngalih

Edge-corE-AIS800-32D-800-Gigabit-AI -lan-Data-Center -Ethernet-Switch-product

Isi Paket

Edge-corE AIS800-32D 800 Gigabit AI lan Data Center Ethernet Switch-fig-1..

  1. ngalih AIS800-32D
  2. Kit pemasangan rel geser - rel geser 2 rak lan pandhuan instalasi
  3. Kabel daya AC (mung kalebu PSU AC)
  4. Kabel daya DC (kalebu mung PSU DC)
  5. Piring lemah
  6. Ground lug (opsional)
  7. Dokumentasi—Pandhuan Miwiti Cepet (dokumen iki) lan Informasi Keamanan lan Peraturan

Swaraview

Edge-corE AIS800-32D 800 Gigabit AI lan Data Center Ethernet Switch-fig-2..

  1. 32 x 800G QSFP-DD800 port
  2. Port Manajemen: 2 x 25G SFP28, 1 x 1000BASE-T RJ-45, konsol RJ-45, USB
  3. Sistem LED
  4. 2 x AC utawa DC PSU
  5. 7 x penggemar tray

Sistem LED/TombolEdge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (3)

  1. LED QSFP-DD800: Kuning (800G), Biru (400G), Putih (200G), Ijo (100G)
  2. SFP28 LED: Ijo (link/aktivitas)
  3. RJ-45 MGMT LED: Kiri: Ijo (link/act), Kanan: Ijo (1G/ 100M)
  4. Sistem LED:
    LOC: Flashing Green (switch locator)
    DIAG: Ijo (OK), Abang (fault)
    ALRM: Abang (fault)
    FAN: Ijo (OK), Abang (fault)
    PSU1/PSU2: Ijo (OK), Abang (fault)
  5. RST: tombol Reset

Panggantos FRU

Ganti PSU

  1. Copot kabel daya.
  2. Pencet kancing release lan copot PSU.
  3. Pasang PSU panggantos kanthi arah aliran udara sing cocog.

Edge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (4)

Pengganti Fan TrayEdge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (5)

  1. Tarik kait pelepas gagang.
  2. Copot tray penggemar saka sasis.
  3. Pasang kipas panggantos kanthi arah aliran udara sing cocog.

Ati-ati: Sajrone operasi switch, panggantos penggemar kudu rampung ing rong menit kanggo nyegah switch mati amarga proteksi over-suhu sing dibangun ing.
Ati-ati: Piranti kasebut kudu diinstal ing lokasi sing diwatesi.
Cathetan: Piranti kasebut nduweni installer piranti lunak Open Network Install Environment (ONIE), nanging ora ana gambar piranti lunak piranti.
Cathetan: Gambar ing dokumen iki mung kanggo ilustrasi lan bisa uga ora cocog karo model tartamtu sampeyan.

Pasang Piranti

Ati-ati: Piranti iki kudu dipasang ing kamar telekomunikasi utawa kamar server sing mung bisa diakses dening personel sing nduweni kualifikasi.

Instalasi

Pènget: Kanggo instalasi sing aman lan dipercaya, gunakake mung aksesoris lan sekrup sing kasedhiya karo piranti kasebut. Panganggone aksesoris lan sekrup liyane bisa nyebabake karusakan ing unit kasebut. Sembarang kerusakan sing ditindakake kanthi nggunakake aksesoris sing ora disetujoni ora dijamin dening garansi.Edge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (6)

Nggunakake Kit Slide-Rail

Tindakake pandhuan ing pandhuan instalasi sing kasedhiya ing kit ril geser kanggo masang piranti ing rak.

Cathetan: Bahaya stabilitas. Rak kasebut bisa nyebabake ciloko pribadi sing serius.
Sadurunge ndawakake rak menyang posisi instalasi, maca instruksi instalasi.
Aja sijine beban ing peralatan geser-rel-dipasang ing posisi instalasi.
Aja ninggalake peralatan geser-rel-dipasang ing posisi instalasi.

Ground PirantiEdge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (7)

Verifikasi Rack Ground

Priksa manawa rak ing ngendi piranti bakal dipasang wis grounding kanthi bener lan selaras karo ETSI ETS 300 253. Priksa manawa ana sambungan listrik sing apik menyang titik grounding ing rak (ora ana cat utawa perawatan permukaan sing diisolasi).

Pasang Grounding Wire

Gunakake rong sekrup M5 kanggo masang piring lemah ing sisih pinggir piranti. Pasang kabel grounding karo grounding lug (Panduit LCCF6-14A-L utawa padha, ora klebu) menyang lemah plate nggunakake loro ngawut-awut lan washers M6. Lug grounding kudu nampung #6 AWG kawat tembaga terdampar (ijo karo belang kuning, ora klebu).

Ati-ati: Sambungan bumi ora kena dicopot kajaba kabeh sambungan sumber wis pedhot.

Sambungake DayaEdge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (8)

Pasang siji utawa loro PSU AC utawa DC lan sambungake menyang sumber daya AC utawa DC.

Cathetan: Yen mung nggunakake siji PSU AC kanggo nguwasani sistem sing diisi kanthi lengkap, priksa manawa sampeyan nggunakake volume dhuwurtage sumber (200–240 VAC).

Edge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (9)

  1. lemah
  2. -40 – -72 VDC
  3. DC bali

Ati-ati: Gunakake sumber daya sing disertifikasi UL/IEC/EN 60950-1 lan/utawa 62368-1 kanggo nyambung menyang konverter DC
Ati-ati: Kabeh sambungan daya DC kudu dileksanakake dening profesional qualified.
Cathetan: Sambungake sumber daya DC eksternal menyang PSU. Utawa, sambungake menyang sumber daya DC sing ora toleransi kanthi pemutus sirkuit sing disetujoni UL / CSA sing dirating 80A utawa kaya sing dibutuhake dening kode listrik lokal.
Cathetan: Gunakake kabel tembaga #6 AWG / 13.3 mm2 90°C (kanggo -40 nganti -72 VDC PSU) kanggo nyambung menyang PSU DC. Kencengake sekrup menyang torsi 2.4 Nm (21.2 lbf.in).

Nggawe Sambungan JaringanEdge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (10)

Port 800G QSFP-DD800

Pasang transceiver banjur sambungake kabel serat optik menyang port transceiver. Utawa, sambungake kabel DAC utawa AOC langsung menyang slot.

Nggawe Sambungan ManajemenEdge-corE-AIS800-32D-800-Gigabit-AI -and-Data-Center -Ethernet-Switch-fig (11)

Port Manajemen In-Band 25G SFP28

Pasang transceiver banjur sambungake kabel serat optik menyang port transceiver.

10/100/1000M RJ-45 Out-of-Band Management Port

Sambungake Cat. 5e utawa kabel twisted-pair sing luwih apik.

Port Konsol RJ-45

Gunakake kabel console null-modem RJ-45-kanggo-DB-9 (ora klebu) kanggo nyambung menyang PC mlaku piranti lunak terminal emulator. Gunakake kabel adaptor DB-9 USB-kanggo-lanang (ora klebu) kanggo sambungan menyang PC sing ora duwe port serial DB-9. Konfigurasi sambungan serial: 115200 bps, 8 karakter, ora paritas, siji mandeg bit, 8 bit data, lan ora ana kontrol aliran.

Pinout lan kabel konsol:

Piranti RJ-45 Console Null Modem PC 9-Pin DTE Port

  • 6 RXD (nampa data) <————— 3 TXD (ngirim data)
  • 3 TXD (ngirim data) —————> 2 RXD (nampa data)
  • 4,5 SGND (signal ground) —————– 5 SGND (signal ground)

Spesifikasi Hardware

Ngalih Chassis

  • Ukuran (WxDxH) 438.4 x 589 x 44 mm (17.26 x 23.19 x 1.73 in.)
  • Bobot 14.69 kg (32.39 lb), kanthi dipasang 2 PSU lan 7 penggemar
  • Suhu Operasional: 0°C nganti 40°C (32°F nganti 104°F)
  • Panyimpenan: -40 ° C nganti 70 ° C (-40 ° F nganti 158 ° F)
  • Kelembapan Operasi: 5% nganti 95% (non-kondensasi)

Rating Input Sistem

  • Input AC 200-240 VAC, 50/60Hz, 15 A maks. saben PS
  • Input DC -48 – -60 VDC, 53 A maks. saben PS
  • Kepatuhan Regulasi
  • Emisi EN 55032 Kelas A
    • EN 300 386 Kelas A
    • EN 61000-3-2 Kelas A
    • EN 61000-3-3
    • VCCI Kelas A
    • AS/NZS Kelas A
    • ICES-003 Kelas A
    • FCC Kelas A
    • BSMI Kelas A
  • Kakebalan EN 55024/55035
    • EN 300 386
    • EN/IEC 61000-4-2/3/4/5/6/8/11
  • UL Safety (CSA 22.2 No 62368-1 & UL62368-1)
    • CB (IEC/EN 62368-1)
    • BSMI CNS 15598-1

FAQ

  • P: Kepiye cara nyambung menyang port manajemen?
    • A: Gunakake kabel console kasedhiya lan waca pandhuan pinout kanggo sambungan sing tepat.
  • P: Apa sing kudu ditindakake yen LED sistem nuduhake kesalahan?
    • A: Priksa komponen sing cocog (contone, PSU, kipas) lan tindakake pandhuan panggantos yen perlu.
  • P: Apa aku bisa nggunakake sumber daya AC lan DC bebarengan?
    • A: Ya, sampeyan bisa nginstal lan nggunakake salah siji utawa loro sumber daya AC utawa DC adhedhasar syarat sampeyan.

Dokumen / Sumber Daya

Edge-corE AIS800-32D 800 Gigabit AI lan Data Center Ethernet Ngalih [pdf] Pandhuan pangguna
AIS800-32D, AIS800-32D 800 Gigabit AI lan Data Center Ethernet Switch, 800 Gigabit AI lan Data Center Ethernet Switch, AI lan Data Center Ethernet Switch, Data Center Ethernet Switch, Ethernet Switch

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *