Edge-corE AIS800 Gigabit AI lan Data Center Ethernet Switch

Edge-corE AIS800 Gigabit AI lan Data Center Ethernet Switch

Isi Paket

  1. 64-Port 800 Gigabit AI & Pusat Data Ethernet Ngalih AIS800- 64O
    Isi Paket
  2. Kit pemasangan rel geser - rel geser 2 rak lan pandhuan instalasi
    Isi Paket
  3. Kabel daya AC, jinis IEC C19/C20 (kalebu mung PSU AC)
    Isi Paket
  4. Kabel daya DC (kalebu mung PSU DC)
    Isi Paket
  5. Dokumentasi—Pandhuan Miwiti Cepet (dokumen iki) lan Informasi Keamanan lan Peraturan
    Isi Paket

Swaraview

  1. 64 x 800G OSFP800 port
  2. Port Manajemen: 1 x 1000BASE-T RJ-45, 2 x 25G SFP28, konsol RJ-45, USB
  3. Port Wektu: 1PPS, 10 MHz, TOD
  4. Sistem LED
  5. 2 x grounding sekrup
  6. 2 x AC utawa DC PSU
  7. 4 x penggemar tray
    Swaraview

Sistem LED/Tombol

  1. OSFP800 LED: Ungu (800G), Biru (400G), Cyan (200G), Ijo (100G), Abang (50G)
  2. RJ-45 MGMT LED: Kiri: Ijo (link/act), Kanan: Ijo (speed)
  3. SFP28 LED: Ijo (link/aktivitas)
  4. Sistem LED:
    LOC: Flashing Green (switch locator)
    DIAG: Ijo (OK), Abang (salah)
    ALRM: Abang (salah)
    Penggemar: Ijo (OK), Abang (salah)
    PSU1/PSU2: Ijo (OK), Abang (salah)
  5. RST: Tombol reset
    Sistem LED/Tombol

Panggantos FRU

Ganti PSU

  1. Copot kabel daya.
  2. Pencet kancing release lan copot PSU.
  3. Pasang PSU panggantos kanthi arah aliran udara sing cocog.
    Ganti PSU

Pengganti Fan Tray

  1. Tarik kait pelepas gagang.
  2. Copot tray penggemar saka sasis.
  3. Pasang kipas panggantos kanthi arah aliran udara sing cocog.
    Pengganti Fan Tray

Simbol Ati-ati: Sajrone operasi switch, panggantos penggemar kudu rampung ing rong menit kanggo nyegah switch mati amarga proteksi over-suhu sing dibangun ing.

Instalasi

Simbol Pènget: Kanggo instalasi sing aman lan dipercaya, gunakake mung aksesoris lan sekrup sing kasedhiya karo piranti kasebut. Panganggone aksesoris lan sekrup liyane bisa nyebabake karusakan ing unit kasebut. Sembarang kerusakan sing ditindakake kanthi nggunakake aksesoris sing ora disetujoni ora dijamin dening garansi.

Simbol Ati-ati: Piranti kasebut kudu diinstal ing lokasi sing diwatesi.

Simbol Cathetan: Piranti kasebut nduweni installer piranti lunak Open Network Install Environment (ONIE), nanging ora ana gambar piranti lunak piranti.

Cathetan: Gambar ing dokumen iki mung kanggo ilustrasi lan bisa uga ora cocog karo model tartamtu sampeyan.

Pasang Piranti

Simbol Ati-ati: Piranti iki kudu diinstal ing kamar telekomunikasi utawa kamar server ngendi mung personel qualified duwe akses.
Pasang Piranti

Nggunakake Kit Slide-Rail

Tindakake pandhuan ing pandhuan instalasi sing kasedhiya ing kit ril geser kanggo masang piranti ing rak.

Simbol Cathetan: Bahaya stabilitas. Rak kasebut bisa nyebabake ciloko pribadi sing serius.
Sadurunge ndawakake rak menyang posisi instalasi, maca instruksi instalasi.
Aja nglebokake peralatan sing dipasang ing slide-rail ing posisi instalasi.
Aja ninggalake peralatan sing dipasang ing slide-rail ing posisi instalasi.

Ground Piranti

Verifikasi Rack Ground

Priksa manawa rak ing ngendi piranti bakal dipasang wis grounding kanthi bener lan selaras karo ETSI ETS 300 253. Priksa manawa ana sambungan listrik sing apik menyang titik grounding ing rak (ora ana cat utawa perawatan permukaan sing diisolasi).
Ground Piranti

Pasang Grounding Wire

Pasang kabel grounding menyang titik grounding ing panel mburi piranti nggunakake rong sekrup M6 lan washers karo lug grounding (Panduit LCDXN2-14AF-E utawa padha, ora klebu). Lug grounding kudu nampung #2 AWG kawat tembaga terdampar (ijo karo belang kuning, ora klebu).

Sambungake Daya

Pasang siji utawa loro PSU AC utawa DC lan sambungake menyang sumber daya AC utawa DC.
Sambungake Daya

Simbol Cathetan: Nalika nggunakake mung siji AC PSU kanggo daya sistem kebak dimuat, dadi manawa kanggo nggunakake dhuwur-voltage sumber (200–240 VAC).

  1. -48 – -60 VDC
  2. DC bali
  3. Sinyal +
  4. Sinyal -
    Sambungake Daya

Simbol Ati-ati: Gunakake UL/IEC/EN 60950-1 lan/utawa 62368-1 Make Management Connections certified power supply kanggo nyambung menyang konverter DC.

Ati-ati: Kabeh sambungan daya DC kudu dileksanakake dening profesional qualified.

Simbol Cathetan: Gunakake # 4 AWG / 21.2 mm2 kabel tembaga (kanggo -48 kanggo -60 VDC PSU) kanggo nyambung menyang DC PSU.

Nggawe Sambungan Jaringan

800G OSFP800 Port

Pasang transceiver banjur sambungake kabel serat optik menyang port transceiver.
Utawa, sambungake kabel DAC utawa AOC langsung menyang slot.
Nggawe Sambungan Jaringan

Sambungake Port Timing

1 Port PPS Kab

Gunakake kabel coax kanggo nyambungake port 1-pulse-per-detik (1PPS) menyang piranti liyane sing disinkronake.

10 MHz Port

Gunakake kabel coax kanggo nyambungake port 10 MHz menyang piranti liyane sing disinkronake.

Pelabuhan TOD

Gunakake kabel sing dilindhungi kanggo nyambungake port RJ-45 Time-of-Day (TOD) menyang piranti liyane sing nggunakake sinyal sinkronisasi iki.
Sambungake Port Timing

Nggawe Sambungan Manajemen

Port Manajemen In-Band 25G SFP28

Pasang transceiver banjur sambungake kabel serat optik menyang port transceiver.

10/100/1000M RJ-45 Out-of-Band Management Port

Sambungake Cat. 5e utawa kabel twisted-pair sing luwih apik.

Port Konsol RJ-45

Gunakake kabel console null-modem RJ-45-kanggo-DB-9 (ora klebu) kanggo nyambung menyang PC mlaku piranti lunak terminal emulator. Gunakake kabel adaptor DB-9 USB-tomale (ora klebu) kanggo sambungan menyang PC sing ora duwe port serial DB-9.

Konfigurasi sambungan serial: 115200 bps, 8 karakter, ora paritas, siji mandeg bit, 8 bit data, lan ora ana kontrol aliran.

Pinout lan kabel konsol:
Nggawe Sambungan Manajemen

Konsol RJ-45 piranti Null Modem Kab Port DTE 9-Pin PC
6 RXD (nampa data) <————— 3 TXD (ngirim data)
3 TXD (ngirim data) —————> 2 RXD (nampa data)
4,5 SGND (sinyal lemah) —————— 5 SGND (sinyal lemah)

Spesifikasi Hardware

Ngalih Chassis 

Ukuran (WxDxH) 440 x 649.2 x 87 mm (17.32 x 25.56 x 3.43 in.)
Bobot 20.5 kg (45.19 lb), karo 2 PSU lan 4 penggemar diinstal
Suhu Operasi (ngarep-mburi): 0° C nganti 40° C (32° F nganti 104° F) ing 1800 m Operasi (mburi-ngarep): 0° C nganti 35° C (32° F nganti 95 ° F) ing 1800 m *tergantung ing optik bekas Panyimpenan: -40° C nganti 70° C (-40° F nganti 158° F)
Kelembapan Operasi: 5% nganti 95% (non-kondensasi)
PSU AC Kab
Input AC 200-240 VAC, 50/60 Hz, 16 A maks.
PSU DC Kab
DC Input -48 kanggo -60 VDC 80 A max.
Rating Input Sistem
Input AC 200-240 VAC, 50/60Hz, 16 A maks. saben PS
DC Input -48 – -60 VDC, 80 A maks. saben PS

Kepatuhan Regulasi 

Emisi EN 55032 Kelas A
EN 61000-3-2
EN 61000-3-3
VCCI-CISPR 32 Kelas A
AS/NZS CISPR 32 Kelas A
ICES-003 Edisi 7 Kelas A
FCC Kelas A
EN 300 386 Kelas A
CNS 15936 Kelas A
Kekebalan EN 55035
IEC 61000-4-2/3/4/5/6/8/11
EN 300 386
Safety UL (CSA 22.2 No 62368-1 & UL62368-1)
CB (IEC/EN 62368-1)
BSMI CNS 15598-1

Dhukungan pelanggan

www.edge-core.com
Logo

Dokumen / Sumber Daya

Edge-corE AIS800 Gigabit AI lan Data Center Ethernet Switch [pdf] Pandhuan pangguna
AIS800 Gigabit AI lan Data Center Ethernet Switch, AIS800, Gigabit AI lan Data Center Ethernet Switch, Data Center Ethernet Switch, Ethernet Switch