Danfoss SonoMeter 40c 
Katrangan
data utama:
- Tipe komunikasi: M-Bus Nirkabel
- daya: <25 mW (868MHz)
- Frekuensi transmisi: 868,95 MHz
- Band: 50 kHz
- Protokol:
- T1 OMS
- S1 (pilihan)
- Mode:
- Mode 5
- Mode 7 (opsional)
- Enkripsi: AES-128
- Aktifake: Diaktifake dhewe sawise ngliwati volume 10L
- Max byte data telegram: 255 byte
- Struktur data telegram: Dipilih miturut tabel data ing ngisor iki
Struktur telegram OMS
Kode lapangan | Byte pos. | Jumlah Bytes | Nilai | Katrangan | Cathetan |
L lapangan | 1 | 1 | xx | Dawane pesen | – |
C lapangan | 2 | 1 | xx | Bidang Kontrol: nuduhake telegram layanan | – |
M lapangan | 3-4 | 2 | D3 10 | Kode pabrikan DFS - Danfoss A/S | – |
A lapangan | 5-6-7-8 | 4 | xx xx xx xx | Nomer seri piranti (8 digit) | – |
Generasi | 9 | 1 | xx | generasi wMbus piranti | – |
Sedheng |
10 |
1 |
04 |
Jinis piranti
04 - Aplikasi pemanasan 0D - Aplikasi Pemanasan / Pendinginan |
– |
lapangan CI | 11 | 1 | xx | Informasi Kontrol | – |
Count | 12 | 1 | xx | Jumlah progresif (nomer akses = counter transmisi) | – |
Byte status | 13 | 1 | xx | Ngandhut flag weker | – |
teken | 14-15 | 2 | xx xx | Tembung konfigurasi (ciphering OMS karo profile A: xx xx utawa ora ciphering: 00 00) | – |
AES-verifikasi | 16-17 | 2 | 2f 2f | Bidang verifikasi enkripsi (yen transmisi ora diaktifake, kolom iki ora ana) | Opt. |
data | xx…xx | – | xx…xx xx xx xx | Struktur telegram Data pangguna bisa dipilih kanthi individu | – |
Struktur telegram Data Pangguna Utama
Paramèter | Byte (DIF VIF) | Jumlah Byte Data | Unit | Katrangan |
Tanggal lan Wektu | 04 6D | 4 | Tipe F | 32-bit integer |
Tanggal lan Wektu kesalahan diwiwiti | 34 6D | 4 | Tipe F | 32-bit integer |
Kode kesalahan | 34 FD 17 | 4 | – | 32-bit integer |
Wektu operasi baterei | 04 20 | 4 | sek | 32-bit integer |
Wektu kerja tanpa kesalahan | 04 24 | 4 | sek | 32-bit integer |
Energi kanggo Pemanasan |
04 86 3B
04 8E 3B 04 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Energi kanggo Cooling * |
04 86 3C
04 8E 3C 04 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Energi Tarif 1 * |
84 10 86 3x
84 10 8E 3x 84 10 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Energi Tarif 2 * |
84 20 86 3x
84 20 8E 3x 84 20 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Volume | 04 13 | 4 | 0,001m3 | 32-bit integer |
Volume Input Pulsa 1 * | 84 40 13 | 4 | 0,001m3 | 32-bit integer |
Volume Input Pulsa 2 * | 84 80 40 13 | 4 | 0,001m3 | 32-bit integer |
daya | 04 2B | 4 | W | 32-bit integer |
Laju aliran | 04 3B | 4 | 0,001 m3/jam | 32-bit integer |
Suhu Aliran | 02 59 | 2 | 0.01 °C | 16-bit integer |
Suhu bali | 02 5D | 2 | 0.01 °C | 16-bit integer |
Bedane Suhu | 02 61 | 2 | 0.01 K | 16-bit integer |
Nomer Seri | 0C 78 | 4 | – | 32-bit integer BCD8 |
Struktur telegram Data Logger Jam
Paramèter | Byte (DIF VIF) | Jumlah Byte Data | Unit | Katrangan |
Tanggal lan Wektu Logger | C4 86 03 6D | 4 | Tipe F | 32-bit integer |
Daya rata-rata | C4 86 03 2B | 4 | W | 32-bit integer |
Rata-rata Flow Rate | C4 86 03 3B | 4 | 0,001 m3/jam | 32-bit integer |
Suhu Aliran Rata-rata | C2 86 03 59 | 2 | 0.01 °C | 16-bit integer |
Rata-rata Return Suhu | C2 86 03 5D | 2 | 0.01 °C | 16-bit integer |
Aliran Minimal Logger | E4 86 03 3B | 4 | 0,001 m3/jam | 32-bit integer |
Aliran Maksimum Logger | D4 86 03 3B | 4 | 0,001 m3/jam | 32-bit integer |
Prabédan Suhu Minimal Logger | E2 86 03 61 | 2 | 0.01 K | 16-bit integer |
Beda Suhu Maksimum Logger | D2 86 03 61 | 2 | 0.01 K | 16-bit integer |
Kode kesalahan logger | F4 86 03 FD 17 | 4 | – | 32-bit integer |
Wektu kerja Logger tanpa kesalahan | C4 86 03 24 | 4 | sek | 32-bit integer |
Paramèter | Byte (DIF VIF) | Jumlah Byte Data | Unit | Katrangan |
Energi Logger kanggo Pemanasan |
C4 86 03 86 3B
C4 86 03 8E 3B C4 86 03 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy kanggo Cooling |
C4 86 03 86 3C
C4 86 03 8E 3C C4 86 03 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger Tarif 1 * |
C4 96 03 86 3x
C4 96 03 8E 3x C4 96 03 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Tenaga Logger Tarif 2 * |
C4 A6 03 86 3x C4 A6 03 8E 3x
C4 A6 03 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Volume Logger | C4 86 03 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 1 * | C4 C6 03 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 2 * | C4 86 43 13 | 4 | 0,001m3 | 32-bit integer |
Durasi Logger nalika q > qmax | C4 86 03 BE 58 | 4 | sek | 32-bit integer |
Struktur telegram Data Logger Days
Paramèter | Byte (DIF VIF) | Jumlah Byte Data | Unit | Katrangan |
Tanggal lan Wektu Logger | 84 08 6D | 4 | Tipe F | 32-bit integer |
Suhu Aliran Rata-rata | 82 08 59 | 2 | 0.01 °C | 16-bit integer |
Rata-rata Return Suhu | 82 08 5D | 2 | 0.01 °C | 16-bit integer |
Wektu kerja Logger tanpa kesalahan | 84 08 24 | 4 | sek | 32-bit integer |
Energi Logger kanggo Pemanasan |
84 08 86 3B
84 08 8E 3B 84 08 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger kanggo Pendinginan * |
84 08 86 3C
84 08 8E 3C 84 08 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger Tarif 1 * |
84 18 86 3x
84 18 8E 3x 84 18 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Tenaga Logger Tarif 2 * |
84 28 86 3x
84 28 8E 3x 84 28 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Volume Logger | 84 08 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 1 * | 84 48 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 2 * | 84 88 40 13 | 4 | 0,001m3 | 32-bit integer |
Durasi Logger nalika q > qmax | 84 08 BB 58 | 4 | sek | 32-bit integer |
Struktur telegram Data Logger Bulan
Paramèter | Byte (DIF VIF) | Jumlah Byte Data | Unit | Katrangan |
Tanggal lan Wektu Logger | 84 08 6D | 4 | Tipe F | 32-bit integer |
Suhu Aliran Rata-rata | 82 08 59 | 2 | 0.01 °C | 16-bit integer |
Rata-rata Return Suhu | 82 08 5D | 2 | 0.01 °C | 16-bit integer |
Wektu kerja Logger tanpa kesalahan | 84 08 24 | 4 | sek | 32-bit integer |
Energi Logger kanggo Pemanasan |
84 08 86 3B
84 08 8E 3B 84 08 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger kanggo Pendinginan * |
84 08 86 3C
84 08 8E 3C 84 08 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger Tarif 1 * |
84 18 86 3x
84 18 8E 3x 84 18 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Tenaga Logger Tarif 2 * |
84 28 86 3x
84 28 8E 3x 84 28 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Volume Logger | 84 08 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 1 * | 84 48 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 2 * | 84 88 40 13 | 4 | 0,001m3 | 32-bit integer |
Durasi Logger nalika q > qmax | 84 08 BB 58 | 4 | sek | 32-bit integer |
Struktur telegram Data Logger Taun
Paramèter | Byte (DIF VIF) | Jumlah Byte Data | Unit | Katrangan |
Tanggal lan Wektu Logger | 44 6D | 4 | Tipe F | 32-bit integer |
Wektu kerja Logger tanpa kesalahan | 44 24 | 4 | sek | 32-bit integer |
Energi Logger kanggo Pemanasan |
44 86 3B
44 8E 3B 44 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger kanggo Pendinginan * |
44 86 3C
44 8E 3C 44 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Tenaga Logger Tarif 1 * |
C4 10 86 3x C4 10 8E 3x
C4 10 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Tenaga Logger Tarif 2 * |
C4 20 86 3x C4 20 8E 3x
C4 20 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – kanggo energi Pemanasan, x = C – kanggo energi pendinginan |
Volume Logger | 44 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 1 * | C4 40 13 | 4 | 0,001m3 | 32-bit integer |
Volume Logger Input Pulsa 2 * | C4 80 40 13 | 4 | 0,001m3 | 32-bit integer |
Definisi format Tipe F
Byte 1 | Byte 2 | Byte 3 | Byte 4 | ||||||||||||||
0 | 0 | N5 | N4 | N3 | N2 | N1 | N0 | 0 | 0 | 0 | H4 | H3 | H2 | H1 | H0 | = Byte 1 Tipe G | = Byte 2 Tipe G |
H4…H0 – kode jam (0…23)
N5…N0 – kode menit (0…59)
Definisi format Tipe G
Byte 1 | Byte 2 | ||||||||||||||
Y2 | Y1 | Y0 | D4 | D3 | D2 | D1 | D0 | Y6 | Y5 | Y4 | Y3 | M3 | M2 | M1 | M0 |
Y6…Y0 – kode taun (0…99)
M3…M0 – kode wulan (1…12)
D4…D0 – kode dina (1…31)
Definisi kode status
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
Ora digunakake |
Jeblugan |
Kebocoran |
Kesalahan sementara |
kesalahan permanen |
daya kurang |
00 - ora ana kesalahan 01 - ora digunakake 10 - ora digunakake
11 - kahanan ora normal |
Example saka telegram data
D8 44 09 07 48 26 00 03 0B 0D 7A 9C 10 00 00 04 6D 00 09 C2 22 34 6D 00 00 01 01 34 FD 17 00 04 00 04 04 20 3 84 4 05 04 24 3 84 4 05 04 86 3C 00. 00 C00 00 04 86D 3B 00 C00 00 C00 04 13 00B 00 00 00 84 C40 13 00 00B 00 00 84 80 C40 13 00 00 A00 00 C04 2 A09 00 00 04 3 2 E09 00 00 02 ED FF D59 02 5 48 26 4 F86 03 6 FD 3 08 2 22 4 C86 03 2 00 00E 00 00C 4 C86 03 3 00 C00 00 00 2 86 C03 59 1 C09 2 86 03 5 5 09 4 C86 03 3 BB 00 00 00 00 4
OMS Header | D8 44 09 07 48 26 00 03 0B 0D 7A 9C 10 00 00 |
Data Saiki |
04 6D 00 09 C2 22 34 6D 00 00 01 01 34 FD 17 00 04 00 04 04 20 B3 84 4C 05 04 24 B3 84 4C 05 04 86 3
00 00 04 86 3C 00 00 00 00 04 13 00 00 00 00 84 40 13 00 00 00 00 84 80 40 13 00 00 00 00 04 2 09B A 04 3B B2 09 00 00 02 59 FC FF 02 5D 48 26 |
Data jam |
C4 86 03 6D 3B 08 C2 22 C4 86 03 2B 00 00 00 00 C4 86 03 3B 00 00 00 00 C2 86 03 59 A1 09 C2 86 03 5D A5
E4 86 03 3B 00 00 00 00 D4 86 03 3B 00 00 00 00 E2 86 03 61 ED FF D2 86 03 61 16 00 F4 86 03 FD 17 00 14 04 C4 86 03 24 8E 84 4C 05 C4 86 03 86 3B 00 00 00 00 C4 86 03 86 3C 00 00 00 00 C4 86 03 13 00 00 C00 00 86 03 BB 58 00 00 00 00 |
Danfoss A / S
Solusi Iklim danfoss.com +45 7488 2222
katrangan katalog, iklan, etc., lan kita ing pilihan saka produk aplikasi utawa kita bobot desain produk, dimensi. kapasitas oray data technical liyane ing produk Tand kanggo manual, ombone, referensi eksplisit digawe ing kutipan utawa konfirmasi pesenan. Danfoss ora bisa nanggung tanggung jawab kanggo kemungkinan kesalahan ing katalog, brosur, video, lan materi liyane
Danfoss duwe hak kanggo ngganti produke tanpa kabar. Iki uga ditrapake kanggo produk sing dipesen nanging ora dikirim yen owah-owahan kasebut bisa ditindakake tanpa owah-owahan ing wangun, pas utawa fungsi produk kasebut.
Kabeh merek dagang ing materi iki minangka properti saka Danfoss A/S utawa perusahaan grup Danfoss. Danfoss lan logo Danfoss minangka merek dagang Danfoss A/S. Kabeh hak dilindhungi undhang-undhang.
Dokumen / Sumber Daya
![]() |
Danfoss SonoMeter 40c [pdf] Pandhuan Instalasi Deskripsi protokol SonoMeter 40 SonoMeter 40c Wireless M-Bus, SonoMeter 40, Deskripsi protokol M-Bus Nirkabel SonoMeter 40c, deskripsi protokol M-Bus Nirkabel 40c, deskripsi protokol |