Danfoss SonoMeter 40c 
Description
Main data:
- Communication type: Wireless M-Bus
- Power: <25 mW (868MHz)
- Transmitting frequency: 868,95 MHz
- Band: 50 kHz
- Protocol:
- T1 OMS
- S1 (optional)
- Mode:
- Mode 5
- Mode 7 (optional)
- Encryption: AES-128
- Activation: Self-activated after passing 10L of volume
- Max bytes of data telegram: 255 bytes
- Data telegram structure: Selected according to the data tables below
OMS telegram structure
Field Code | Byte pos. | No. of Bytes | Value | Description | Note |
L field | 1 | 1 | xx | Message length | – |
C field | 2 | 1 | xx | Control Field: indicates service telegram | – |
M field | 3-4 | 2 | D3 10 | Manufacturer code DFS – Danfoss A/S | – |
A field | 5-6-7-8 | 4 | xx xx xx xx | Serial number of the device (8-digit) | – |
Generation | 9 | 1 | xx | wMbus generation of the device | – |
Medium |
10 |
1 |
04 |
Device type
04 – Heating application 0D – Heating / Cooling application |
– |
CI field | 11 | 1 | xx | Control Information | – |
Count | 12 | 1 | xx | Progressive count (access number = transmission counter) | – |
Status byte | 13 | 1 | xx | Contains flag of alarm | – |
Signature | 14-15 | 2 | xx xx | Configuration word (ciphering OMS with profile A: xx xx or not ciphering: 00 00) | – |
AES-verify | 16-17 | 2 | 2F 2F | Encryption verification field (if the transmission is not enabled, this field is missing) | Opt. |
Data | xx…xx | – | xx…xx xx xx xx | User Data telegram structure can be selected individually | – |
Main User Data telegram structure
Parameter | Bytes (DIF VIF) | No. of Data Bytes | Units | Description |
Date and Time | 04 6D | 4 | Type F | 32-bit integer |
Date and Time of error starting | 34 6D | 4 | Type F | 32-bit integer |
Error code | 34 FD 17 | 4 | – | 32-bit integer |
Battery operation time | 04 20 | 4 | sec | 32-bit integer |
Working time without error | 04 24 | 4 | sec | 32-bit integer |
Energy for Heating |
04 86 3B
04 8E 3B 04 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Energy for Cooling* |
04 86 3C
04 8E 3C 04 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Energy of Tariff 1 * |
84 10 86 3x
84 10 8E 3x 84 10 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Energy of Tariff 2 * |
84 20 86 3x
84 20 8E 3x 84 20 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Volume | 04 13 | 4 | 0,001 m3 | 32-bit integer |
Volume of Pulse Input 1 * | 84 40 13 | 4 | 0,001 m3 | 32-bit integer |
Volume of Pulse Input 2 * | 84 80 40 13 | 4 | 0,001 m3 | 32-bit integer |
Power | 04 2B | 4 | W | 32-bit integer |
Flow rate | 04 3B | 4 | 0,001 m3/h | 32-bit integer |
Flow Temperature | 02 59 | 2 | 0.01 °C | 16-bit integer |
Return Temperature | 02 5D | 2 | 0.01 °C | 16-bit integer |
Temperature Difference | 02 61 | 2 | 0.01 K | 16-bit integer |
Serial Number | 0C 78 | 4 | – | 32-bit integer BCD8 |
Hours Logger Data telegram structure
Parameter | Bytes (DIF VIF) | No. of Data Bytes | Units | Description |
Logger Date and Time | C4 86 03 6D | 4 | Type F | 32-bit integer |
Average Power | C4 86 03 2B | 4 | W | 32-bit integer |
Average Flow Rate | C4 86 03 3B | 4 | 0,001 m3/h | 32-bit integer |
Average Flow Temperature | C2 86 03 59 | 2 | 0.01 °C | 16-bit integer |
Average Return Temperature | C2 86 03 5D | 2 | 0.01 °C | 16-bit integer |
Logger Minimum Flow | E4 86 03 3B | 4 | 0,001 m3/h | 32-bit integer |
Logger Maximum Flow | D4 86 03 3B | 4 | 0,001 m3/h | 32-bit integer |
Logger Minimum Temperature Difference | E2 86 03 61 | 2 | 0.01 K | 16-bit integer |
Logger Maximum Temperature Difference | D2 86 03 61 | 2 | 0.01 K | 16-bit integer |
Logger error code | F4 86 03 FD 17 | 4 | – | 32-bit integer |
Logger working time without error | C4 86 03 24 | 4 | sec | 32-bit integer |
Parameter | Bytes (DIF VIF) | No. of Data Bytes | Units | Description |
Logger Energy for Heating |
C4 86 03 86 3B
C4 86 03 8E 3B C4 86 03 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy for Cooling |
C4 86 03 86 3C
C4 86 03 8E 3C C4 86 03 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy of Tariff 1 * |
C4 96 03 86 3x
C4 96 03 8E 3x C4 96 03 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Energy of Tariff 2 * |
C4 A6 03 86 3x C4 A6 03 8E 3x
C4 A6 03 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Volume | C4 86 03 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 1 * | C4 C6 03 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 2 * | C4 86 43 13 | 4 | 0,001 m3 | 32-bit integer |
Logger duration when q > qmax | C4 86 03 BE 58 | 4 | sec | 32-bit integer |
Days Logger Data telegram structure
Parameter | Bytes (DIF VIF) | No. of Data Bytes | Units | Description |
Logger Date and Time | 84 08 6D | 4 | Type F | 32-bit integer |
Average Flow Temperature | 82 08 59 | 2 | 0.01 °C | 16-bit integer |
Average Return Temperature | 82 08 5D | 2 | 0.01 °C | 16-bit integer |
Logger working time without error | 84 08 24 | 4 | sec | 32-bit integer |
Logger Energy for Heating |
84 08 86 3B
84 08 8E 3B 84 08 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy for Cooling * |
84 08 86 3C
84 08 8E 3C 84 08 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy of Tariff 1 * |
84 18 86 3x
84 18 8E 3x 84 18 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Energy of Tariff 2 * |
84 28 86 3x
84 28 8E 3x 84 28 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Volume | 84 08 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 1 * | 84 48 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 2 * | 84 88 40 13 | 4 | 0,001 m3 | 32-bit integer |
Logger duration when q > qmax | 84 08 BB 58 | 4 | sec | 32-bit integer |
Months Logger Data telegram structure
Parameter | Bytes (DIF VIF) | No. of Data Bytes | Units | Description |
Logger Date and Time | 84 08 6D | 4 | Type F | 32-bit integer |
Average Flow Temperature | 82 08 59 | 2 | 0.01 °C | 16-bit integer |
Average Return Temperature | 82 08 5D | 2 | 0.01 °C | 16-bit integer |
Logger working time without error | 84 08 24 | 4 | sec | 32-bit integer |
Logger Energy for Heating |
84 08 86 3B
84 08 8E 3B 84 08 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy for Cooling * |
84 08 86 3C
84 08 8E 3C 84 08 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy of Tariff 1 * |
84 18 86 3x
84 18 8E 3x 84 18 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Energy of Tariff 2 * |
84 28 86 3x
84 28 8E 3x 84 28 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Volume | 84 08 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 1 * | 84 48 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 2 * | 84 88 40 13 | 4 | 0,001 m3 | 32-bit integer |
Logger duration when q > qmax | 84 08 BB 58 | 4 | sec | 32-bit integer |
Years Logger Data telegram structure
Parameter | Bytes (DIF VIF) | No. of Data Bytes | Units | Description |
Logger Date and Time | 44 6D | 4 | Type F | 32-bit integer |
Logger working time without error | 44 24 | 4 | sec | 32-bit integer |
Logger Energy for Heating |
44 86 3B
44 8E 3B 44 FB 8D 3B |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy for Cooling * |
44 86 3C
44 8E 3C 44 FB 8D 3C |
4 |
kWh MJ
Mcal |
32-bit integer |
Logger Energy of Tariff 1 * |
C4 10 86 3x C4 10 8E 3x
C4 10 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Energy of Tariff 2 * |
C4 20 86 3x C4 20 8E 3x
C4 20 FB 8D 3x |
4 |
kWh MJ
Mcal |
32-bit integer
x = B – for Heating energy, x = C – for Cooling energy |
Logger Volume | 44 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 1 * | C4 40 13 | 4 | 0,001 m3 | 32-bit integer |
Logger Volume of Pulse Input 2 * | C4 80 40 13 | 4 | 0,001 m3 | 32-bit integer |
Definition of the Type F format
Byte 1 | Byte 2 | Byte 3 | Byte 4 | ||||||||||||||
0 | 0 | N5 | N4 | N3 | N2 | N1 | N0 | 0 | 0 | 0 | H4 | H3 | H2 | H1 | H0 | = Byte 1 Type G | = Byte 2 Type G |
H4…H0 – code of the hour (0…23)
N5…N0 – code of the minute (0…59)
Definition of the Type G format
Byte 1 | Byte 2 | ||||||||||||||
Y2 | Y1 | Y0 | D4 | D3 | D2 | D1 | D0 | Y6 | Y5 | Y4 | Y3 | M3 | M2 | M1 | M0 |
Y6…Y0 – code of the year (0…99)
M3…M0 – code of the month (1…12)
D4…D0 – code of the day (1…31)
Definition of the Status code
Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
Not used |
Burst |
Leakage |
Temporary error |
Permanent error |
Low power |
00 – no error 01 – not used 10 – not used
11 – abnormal condition |
Example of the data telegram
D8 44 09 07 48 26 00 03 0B 0D 7A 9C 10 00 00 04 6D 00 09 C2 22 34 6D 00 00 01 01 34 FD 17 00 04 00 04 04 20 B3 84 4C 05 04 24 B3 84 4C 05 04 86 3B 00 00 00 00 04 86 3C 00 00 00 00 04 13 00 00 00 00 84 40 13 00 00 00 00 84 80 40 13 00 00 00 00 04 2B AE 09 00 00 04 3B B2 09 00 00 02 59 FC FF 02 5D 48 26 C4 86 03 6D 3B 08 C2 22 C4 86 03 2B 00 00 00 00 C4 86 03 3B 00 00 00 00 C2 86 03 59 A1 09 C2 86 03 5D A5 09 E4 86 03 3B 00 00 00 00 D4 86 03 3B 00 00 00 00 E2 86 03 61 ED FF D2 86 03 61 16 00 F4 86 03 FD 17 00 14 00 04 C4 86 03 24 8E 84 4C 05 C4 86 03 86 3B 00 00 00 00 C4 86 03 86 3C 00 00 00 00 C4 86 03 13 00 00 00 00 C4 86 03 BB 58 00 00 00 00
OMS Header | D8 44 09 07 48 26 00 03 0B 0D 7A 9C 10 00 00 |
Current Data |
04 6D 00 09 C2 22 34 6D 00 00 01 01 34 FD 17 00 04 00 04 04 20 B3 84 4C 05 04 24 B3 84 4C 05 04 86 3B 00 00
00 00 04 86 3C 00 00 00 00 04 13 00 00 00 00 84 40 13 00 00 00 00 84 80 40 13 00 00 00 00 04 2B AE 09 00 00 04 3B B2 09 00 00 02 59 FC FF 02 5D 48 26 |
Hours Data |
C4 86 03 6D 3B 08 C2 22 C4 86 03 2B 00 00 00 00 C4 86 03 3B 00 00 00 00 C2 86 03 59 A1 09 C2 86 03 5D A5 09
E4 86 03 3B 00 00 00 00 D4 86 03 3B 00 00 00 00 E2 86 03 61 ED FF D2 86 03 61 16 00 F4 86 03 FD 17 00 14 00 04 C4 86 03 24 8E 84 4C 05 C4 86 03 86 3B 00 00 00 00 C4 86 03 86 3C 00 00 00 00 C4 86 03 13 00 00 00 00 C4 86 03 BB 58 00 00 00 00 |
Danfoss A/S
Climate Solutions danfoss.com +45 7488 2222
catalog descriptions, advertisements, etc., and we on the selection of product its application or us product design weight, dimensions. capacity oray other technical data in product Tand to manuals, extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogs, brochures, videos, and other material
Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to the form, fit or function of the product.
All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.