Danfoss AK-CC 550B Case Controller

Danfoss-AK-CC-550B-Case-Controller-PRODUCT-IMAGE

Spesifikasi:

  • Model: AK-CC 550B
  • Sumber Daya: 230 V ac, 50/60 Hz

Pandhuan Panggunaan Produk

Sambungan tambahan:

  • RS485 (terminal 51, 52, 53)
  • RJ45 (kanggo komunikasi data)
  • Sensor: S2, S6, S3, S4, S5
  • MODBUS (kanggo komunikasi data)

Pedoman Panggunaan:
Priksa manawa kabeh sambungan tundhuk karo syarat kanggo kabel komunikasi data. Waca literatur: RC8AC kanggo informasi luwih lengkap.

Sumber Daya:
Priksa manawa pasokan voltage iku 230 V ac, 50/60 Hz.

Koneksi DO1:
Sambungake jinis tutup expansion AKV utawa AKVA. Koil kudu dadi kumparan ac 230 V.

Sambungan Alarm DO2:
Ing kahanan weker lan nalika pengontrol ora ana daya, sambungake terminal 7 lan 8.

Identifikasi

Danfoss-AK-CC-550B-Case-Controller- (1)

ukuran

Danfoss-AK-CC-550B-Case-Controller- (2)

Prinsip

Danfoss-AK-CC-550B-Case-Controller- (3)

S2:
Sensor isolasi

Info AKV!!

Danfoss-AK-CC-550B-Case-Controller- (4)

AK-CC 550B

Informasi tambahan: Manual Inggris      RS8GL…      www.danfoss.com

Danfoss-AK-CC-550B-Case-Controller- (5)

Kontroler diwenehi tandha saka pabrik sing nuduhake aplikasi 1.
Yen sampeyan nggunakake panggunaan liyane, tandha diwenehake supaya sampeyan bisa nginstal sing cocog.

Danfoss-AK-CC-550B-Case-Controller- (6)

Danfoss-AK-CC-550B-Case-Controller- (7)

Danfoss-AK-CC-550B-Case-Controller- (8)

Danfoss-AK-CC-550B-Case-Controller- (9)

Danfoss-AK-CC-550B-Case-Controller- (10)

Danfoss-AK-CC-550B-Case-Controller- (11)

Danfoss-AK-CC-550B-Case-Controller- (12)

Danfoss-AK-CC-550B-Case-Controller- (13)

Danfoss-AK-CC-550B-Case-Controller- (14)

Danfoss-AK-CC-550B-Case-Controller- (15)

Danfoss-AK-CC-550B-Case-Controller- (16)

Danfoss-AK-CC-550B-Case-Controller- (17)

Danfoss-AK-CC-550B-Case-Controller- (18)

Komunikasi data

penting Kabeh sambungan menyang komunikasi data MODBUS, DANBUSS lan RS 485 kudu tundhuk karo syarat kanggo kabel komunikasi data. Waca literatur: RC8AC.

Danfoss-AK-CC-550B-Case-Controller- (19)

Manajer sistem / Gateway

Tampilan EKA 163/164

L <15 m

Danfoss-AK-CC-550B-Case-Controller- (20)

L > 15 m

Danfoss-AK-CC-550B-Case-Controller- (21)

Sambungan

Danfoss-AK-CC-550B-Case-Controller- (22)

Swaraview saka output lan aplikasi.
Deleng uga diagram listrik sadurunge instruksi kasebut

Danfoss-AK-CC-550B-Case-Controller- (23)

DI1
Sinyal input digital.
Fungsi sing ditemtokake aktif nalika input short-circuited/mbukak. Fungsi kasebut ditetepake ing o02.

DI2
Sinyal input digital.
Fungsi sing ditemtokake aktif nalika input short-circuited/mbukak. Fungsi kasebut ditetepake ing o37.

Pemancar tekanan
AKS 32R
Sambungake menyang terminal 30, 31 lan 32.
(Kabel bekas 060G1034: Ireng=30, Biru=31, Coklat=32)
Sinyal saka siji pemancar tekanan bisa ditampa nganti 10 pengontrol. Nanging mung yen ora ana penurunan tekanan sing signifikan ing antarane evaporator sing kudu dikontrol. Waca gambar kaca 36.

S2, S6
Pt 1000 ohm sensor
S6, sensor produk

S3, S4, S5
Sensor Pt 1000 ohm utawa sensor PTC 1000 ohm. Kabeh kudu saka jinis sing padha.
S3, sensor udara, diselehake ing hawa anget sadurunge evaporator
S4, sensor hawa, diselehake ing hawa adhem sawise evaporator (perlu S3 utawa S4 bisa dicopot ing konfigurasi) S5, sensor defrost, diselehake ing evaporator

Tampilan EKA
Yen ana maca eksternal / operasi pengontrol, jinis tampilan EKA 163B utawa EKA 164B bisa disambungake.

RS485 (terminal 51, 52, 53)
Kanggo komunikasi data, nanging mung yen modul komunikasi data dilebokake ing controller. Modul kasebut bisa dadi LON RS485, DANBUSS utawa MODBUS.

  • Terminal 51 = layar
  • Terminal 52 = A (A+)
  • Terminal 53 = B (B-)

(Kanggo LON RS485 lan tipe gateway AKA 245 gateway kudu versi 6.20 utawa luwih dhuwur.)

RJ45
Kanggo komunikasi data, nanging mung yen TCP / modul IP dipasang ing controller. (OEM)

MODBUS
Kanggo komunikasi data.

  • Terminal 56 = layar
  • Terminal 57 = A+
  • Terminal 58 = B-

(Utawa, terminal bisa disambungake menyang jinis tampilan eksternal EKA 163A utawa 164A, nanging banjur ora bisa digunakake kanggo komunikasi data. Sembarang komunikasi data banjur kudu digawa metu dening salah siji saka cara liyane.)

Pasokan voltage
230 V ac, 50/60 Hz

C1
Sambungan jinis katup ekspansi AKV utawa AKVA. Koil kudu dadi kumparan ac 230 V.

C2
Weker
Ana sambungan antarane terminal 7 lan 8 ing kahanan weker lan nalika controller tanpa daya.
Panas rel lan unsur pemanas ing tray netes
Ana sambungan antarane terminal 7 lan 9 nalika dadi panas.

wuta wengi
Ana sambungan antarane terminal 7 lan 9 nalika wuta wengi wis munggah.

Katup saluran isap
Ana sambungan antarane terminal 7 lan 9 nalika saluran nyedhot kudu mbukak.

C3
Pendinginan, Panas rel, Fungsi panas, Defrost 2
Ana sambungan antarane terminal 10 lan 11 nalika fungsi kudu aktif.
Elemen pemanas ing tray netes
Ana sambungan antarane terminal 10 lan 11 nalika dadi panas.

C4
defrost
Ana sambungan antarane terminal 12 lan 14 nalika defrosting njupuk Panggonan.
Gas panas / katup saluran
Ana sambungan antarane terminal 13 lan 14 sajrone operasi normal.
Ana sambungan antarane terminal 12 lan 14 nalika klep gas panas kudu mbukak.

C5
Penggemar
Ana sambungan antarane terminal 15 lan 16 nalika penggemar urip.

C6
Relay cahya
Ana sambungan antarane terminal 17 lan 18 nalika lampu kudu urip.
Panas rel, Kompresor 2
Ana sambungan antarane terminal 17 lan 19 nalika fungsi kudu aktif.

DI3
Sinyal input digital.
Sinyal kudu duwe voltage saka 0 / 230 V AC.
Fungsi kasebut ditetepake ing o84.

Komunikasi data
Yen komunikasi data digunakake, penting yen instalasi kabel komunikasi data ditindakake kanthi bener.
Deleng literatur kapisah No. RC8AC…

swara listrik

Kabel kanggo sensor, input DI lan komunikasi data kudu dipisahake saka kabel listrik liyane:

  • Gunakake tray kabel sing kapisah
  • Jaga jarak antarane kabel paling sethithik 10 cm
  • Kabel dawa ing input DI kudu nyingkiri

pertimbangan instalasi
Kerusakan sing ora disengaja, instalasi sing ora apik, utawa kahanan situs, bisa nyebabake kerusakan sistem kontrol, lan pungkasane nyebabake kerusakan tanduran. Saben pangayoman bisa digabung menyang produk kita kanggo nyegah iki. Nanging, instalasi sing salah, contoneample, isih bisa menehi masalah. Kontrol elektronik ora bisa ngganti praktik teknik sing normal lan apik. Danfoss ora bakal tanggung jawab kanggo samubarang barang, utawa komponen tanduran, rusak minangka asil saka cacat ndhuwur. Iku tanggung jawab installer kanggo mriksa instalasi sak tenane, lan pas karo piranti safety sing perlu. Referensi khusus digawe kanggo kabutuhan sinyal menyang pengontrol nalika kompresor mandheg lan kabutuhan panrima cairan sadurunge kompresor. Agen Danfoss lokal sampeyan bakal seneng menehi saran luwih lanjut, lsp.
Defrost terkoordinasi liwat sambungan kabel

Danfoss-AK-CC-550B-Case-Controller- (24)

Pengontrol ing ngisor iki bisa disambungake kanthi cara iki:
EKC 204A, AK-CC 210, AK-CC 250, AK-CC 450, AK-CC 550A,
Pendinginan diterusake nalika kabeh pengontrol wis "ngeculake" sinyal kanggo defrost.
Defrost terkoordinasi liwat komunikasi data

Danfoss-AK-CC-550B-Case-Controller- (25)

Setelan pengontrol kanggo koordinasi defrosting ditindakake ing manajer gateway / sistem.
Pendinginan diterusake nalika kabeh pengontrol wis "ngeculake" sinyal kanggo defrost.

Operasi

Tampilan
Nilai kasebut bakal ditampilake kanthi telung digit, lan kanthi setelan sampeyan bisa nemtokake manawa suhu bakal ditampilake ing °C utawa ing °F.

Danfoss-AK-CC-550B-Case-Controller- (26)

Light-emitting diode (LED) ing panel ngarep
LED ing panel ngarep bakal murup nalika relay sing cocog diaktifake.

Danfoss-AK-CC-550B-Case-Controller- (27)

Dioda pemancar cahya bakal sumunar yen ana weker.
Ing kahanan iki sampeyan bisa ngundhuh kode kesalahan kanggo tampilan lan mbatalake / mlebu weker kanthi menehi tombol ndhuwur push singkat.

Tombol
Yen sampeyan pengin ngganti setelan, tombol ndhuwur lan ngisor bakal menehi nilai sing luwih dhuwur utawa luwih murah gumantung saka tombol sing sampeyan pencet. Nanging sadurunge sampeyan ngganti nilai, sampeyan kudu duwe akses menyang menu. Sampeyan entuk iki kanthi mencet tombol ndhuwur kanggo sawetara detik - banjur bakal ngetik kolom karo kode parameter. Temokake kode parameter sing pengin diganti lan pencet tombol tengah nganti nilai parameter ditampilake. Yen sampeyan wis ngganti nilai, simpen nilai anyar kanthi mencet tombol tengah maneh.

Examples
Setel menu

  1. Pencet tombol ndhuwur nganti parameter r01 ditampilake
  2. Pencet tombol ndhuwur utawa ngisor lan temokake parameter sing pengin diganti
  3. Pencet tombol tengah nganti nilai parameter ditampilake
  4. Pencet tombol ndhuwur utawa ngisor banjur pilih nilai anyar
  5. Pencet tombol tengah maneh kanggo beku nilai.

Relay weker potong / weker kuitansi / deleng kode weker

  •  Pencet cendhak tombol ndhuwur
    Yen ana sawetara kode weker sing ditemokake ing tumpukan rolling. Pencet tombol paling dhuwur utawa paling ngisor kanggo mindhai tumpukan rolling.

Setel suhu

  1. Pencet tombol tengah nganti nilai suhu ditampilake
  2. Pencet tombol ndhuwur utawa ngisor banjur pilih nilai anyar
  3. Pencet maneh tombol tengah kanggo ngrampungake setelan kasebut.

Maca suhu ing sensor defrost (Utawa sensor produk, yen dipilih ing o92.)

  • Pencet cendhak tombol ngisor

Manuel miwiti utawa mungkasi defrost a

  • Pencet tombol ngisor nganti patang detik.

Entuk wiwitan sing apik
Kanthi prosedur ing ngisor iki, sampeyan bisa miwiti regulasi kanthi cepet:

  1. Bukak parameter r12 lan mungkasi angger-angger (ing unit anyar lan durung disetel sadurunge, r12 bakal wis disetel kanggo 0 tegese regulasi mandheg.)
  2. Pilih sambungan listrik adhedhasar gambar ing kaca 2 lan 3
  3. Bukak parameter o61 lan setel nomer sambungan listrik ing kono
  4. Saiki pilih salah siji saka setelan prasetel saka meja
    Jadwal tambahan kanggo setelan (penyiapan cepet) Kasus kamar
    Defrost mandheg Defrost mandheg
    wektu S5 wektu S5
    Setelan prasetel (o62) 1 2 3 4 5 6
    Suhu (SP) 2°C -2°C -28°C 4°C 0°C -22°C
    Maks. suhu setelan (r02) 6°C 4°C -22°C 8°C 5°C -20°C
    Min. suhu setelan (r03) 0°C -4°C -30°C 0°C -2°C -24°C
    Sinyal sensor kanggo thermostat. S4% (r15) 100% 0%
    Watesan weker dhuwur (A13) 8°C 6°C -15°C 10°C 8°C -15°C
    Watesan weker sithik (A14) -5°C -5°C -30°C 0°C 0°C -30°C
    Sinyal sensor kanggo fungsi weker.S4% (A36) 0% 100% 0%
    Interval antarane defrost (d03) 6 h 6h 12h 8h 8h 6h
    Sensor defrost: 0 = wektu, 1 = S5, 2 = S4 (d10) 0 1 1 0 1 1
    DI1 konfigurasi. (o02) Reresik kasus (=10) Fungsi lawang (=2)
    Sinyal sensor kanggo tampilan view S4% (017) 0%
  5. Bukak parameter o62 lan setel nomer kanggo susunan pra-setelan.
    Setelan sawetara sing dipilih saiki bakal ditransfer menyang menu.
  6. Pilih refrigerant liwat parameter o30
  7. Bukak parameter r12 lan miwiti regulasi
  8. Bukak survey setelan pabrik. Nilai ing sel abu-abu diganti miturut pilihan setelan sampeyan. Gawe owah-owahan sing dibutuhake ing paramèter kasebut.
  9. Kanggo jaringan. Setel alamat ing o03
  10. Kirim alamat menyang unit sistem:
    • MODBUS: Aktifake fungsi pindai ing unit sistem
    • Yen kertu komunikasi data liyane digunakake ing controller:
      • LON RS485: Aktifake fungsi o04
      • DANBUSS: Aktifake fungsi pindai ing unit sistem
      • Ethernet: Gunakake Alamat MAC

Survey menu

Paramèter EL-diagram kaca 2 lan 3 Min.- nilai Maks.- nilai Pabrik setelan nyatane
setelan
Fungsi Kode 1 2 3 4 5 6 7 8 9 10
Operasi normal
Suhu (setpoint) --- 1 1 1 1 1 1 1 1 1 1 -50°C 50°C 2
Thermostat
Diferensial r01 1 1 1 1 1 1 1 1 1 1 0.1 K 20 K 2
Maks. watesan setelan setpoint r02 1 1 1 1 1 1 1 1 1 1 -49°C 50°C 50
Min. watesan setelan setpoint r03 1 1 1 1 1 1 1 1 1 1 -50°C 49°C -50
Pangaturan indikasi suhu r04 1 1 1 1 1 1 1 1 1 1 -10 10 0
Unit suhu (°C/°F) r05 1 1 1 1 1 1 1 1 1 1 0/°C 1/F 0/°C
Koreksi sinyal saka S4 r09 1 1 1 1 1 1 1 1 1 1 -10 K 10 K 0
Koreksi sinyal saka S3 lan S3B r10 1 1 1 1 1 1 1 1 1 1 -10 K 10 K 0
Service manual, stop regulation, start regulation (-1, 0, 1) r12 1 1 1 1 1 1 1 1 1 1 -1 1 0
Pamindahan referensi sajrone operasi wengi r13 1 1 1 1 1 1 1 1 1 1 -50 K 50 K 0
Netepake fungsi termostat 1=ON/OFF, 2=Modulating r14 1 1 1 1 1 1 1 1 1 1 1 2 1
Definisi lan bobot, yen ana, termostat
sensor – S4% (100%=S4, 0%=S3)
r15 1 1 1 1 1 1 1 1 1 1 0 % 100 % 100
Wektu antarane periode leleh r16 1 1 1 1 1 1 1 1 1 1 0 jam 10 jam 1
Duration saka periode leleh r17 1 1 1 1 1 1 1 1 1 1 0 min. 30 min. 5
Setelan suhu kanggo band termostat 2. Minangka diferensial nggunakake r01 r21 1 1 1 1 1 1 1 1 1 1 -50°C 50°C 2
Koreksi sinyal saka S6 r59 1 1 1 1 1 1 1 1 1 -10 K 10 K 0
Definisi lan bobot, yen ana, sensor termostat nalika tutup wengi urip. (100%=S4, 0%=S3) r61 1 1 1 1 1 1 1 1 1 1 0 % 100 % 100
Fungsi panas

Zona netral antarane refrigerasi lan fungsi panas

r62 1 0 K 50 K 2
Wektu tundha ing ngalih ing antarane refrigerasi lan fungsi panas r63 1 0 min. 240 min. 0
Weker
Tundha kanggo weker suhu A03 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 30
Tundha kanggo weker lawang A04 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 60
Tundha kanggo weker suhu sawise defrost A12 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 90
Watesan weker dhuwur kanggo termostat 1 A13 1 1 1 1 1 1 1 1 1 1 -50°C 50°C 8
Watesan weker sithik kanggo termostat 1 A14 1 1 1 1 1 1 1 1 1 1 -50°C 50°C -30
Watesan weker dhuwur kanggo termostat 2 A20 1 1 1 1 1 1 1 1 1 1 -50°C 50°C 8
Watesan weker sithik kanggo termostat 2 A21 1 1 1 1 1 1 1 1 1 1 -50°C 50°C -30
Watesan weker dhuwur kanggo sensor S6 ing termostat 1 A22 1 1 1 1 1 1 1 1 1 -50°C 50°C 8
Watesan weker sithik kanggo sensor S6 ing termostat 1 A23 1 1 1 1 1 1 1 1 1 -50°C 50°C -30
Watesan weker dhuwur kanggo sensor S6 ing termostat 2 A24 1 1 1 1 1 1 1 1 1 -50°C 50°C 8
Watesan weker sithik kanggo sensor S6 ing termostat 2 A25 1 1 1 1 1 1 1 1 1 -50°C 50°C -30
S6 wektu tundha weker

Kanthi setelan = 240 weker S6 bakal tilar

A26 1 1 1 1 1 1 1 1 1 0 min. 240 min. 240
Wektu tundha weker utawa sinyal ing input DI1 A27 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 30
Wektu tundha weker utawa sinyal ing input DI2 A28 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 30
Sinyal kanggo termostat weker. S4% (100%=S4, 0%=S3) A36 1 1 1 1 1 1 1 1 1 1 0 % 100 % 100
Tundha kanggo S6 (weker sensor produk) sawise defrost A52 1 1 1 1 1 1 1 1 1 0 min. 240 min. 90
Tundha kanggo weker suhu S3B A53 1 1 0 min. 240 min. 90
Kompresor
Min. ON-wektu c01 1 1 1 1 0 min. 30 min. 0
Min. OFF-wektu c02 1 1 1 1 0 min. 30 min. 0
Wektu tundha kanggo Cut ing comp.2 c05 1 0 sek 999 sek 5
defrost
Metode defrost: 0=Mati, 1= EL, 2= Gas d01 1 1 1 1 1 1 1 1 1 1 0/Pateni 2/gAs 1/EL
Suhu mandeg defrost d02 1 1 1 1 1 1 1 1 1 1 0°C 50°C 6
Interval antarane defrost diwiwiti d03 1 1 1 1 1 1 1 1 1 1 0 jam / Off 240 jam 8
Maks. durasi defrost d04 1 1 1 1 1 1 1 1 1 1 0 min. 360 min. 45
Pamindahan wektu nalika dipotong saka defrost nalika wiwitan d05 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 0
Tetes wektu d06 1 1 1 1 1 1 1 1 1 1 0 min. 60 min. 0
Tundha kanggo wiwitan penggemar sawise defrost d07 1 1 1 1 1 1 1 1 1 1 0 min. 60 min. 0
Suhu wiwitan kipas d08 1 1 1 1 1 1 1 1 1 1 -50 °C 0 °C -5
Fan Cut ing sak defrost 0: Mandheg
  1. mlaku
  2. Mlaku sak pump mudhun lan defrost
  3. Mlaku nanging mandheg ing d41
d09 1 1 1 1 1 1 1 1 1 1 0 2 1
Terus Kode 1 2 3 4 5 6 7 8 9 10 Min. Maks. Fac. nyatane
Sensor defrost: 0 =Stop ing wektu, 1=S5, 2=S4, 3=Sx (Aplikasi 1-8 lan 10: loro S5 lan S6.
Aplikasi 9: S5 lan S5B)
d10 1 1 1 1 1 1 1 1 1 1 0 3 0
Pump mudhun wektu tundha d16 1 1 1 1 1 1 1 1 1 1 0 min. 60 min. 0
Tundha saluran (mung digunakake ing defrost gas panas) d17 1 0 min. 60 min. 0
Maks. wektu refrigerasi agregat antarane rong defrosts d18 1 1 1 1 1 1 1 1 1 1 0 jam 48 jam 0/OFF
Kalor ing tray netes. Wektu saka defrosting mandheg kanggo dadi panas ing tray netes dipateni d20 1 0 min. 240 min. 30
Defrost adaptif:
0 = ora aktif, 1 = mung ngawasi, 2 = skip dina sing diidinake, 3 = skip diidini awan lan wengi, 4 = penilaian dhewe + kabeh jadwal
d21 1 1 1 1 1 1 1 1 1 1 0 4 0
Wektu tundha sadurunge mbukak tutup gas panas d23 1 0 min 60 min 0
Panas rel nalika defrost 0 = mati. 1 = ing. 2 = Pulsa d27 1 1 1 1 1 1 1 0 2 2
Maks. durasi -d- ing tampilan d40 1 1 1 1 1 1 1 1 1 1 5 min. 240 min. 30 min.
Watesan suhu kanggo Fan mandheg nalika defrost nalika d09 disetel dadi 3 d41 1 1 1 1 1 1 1 1 1 1 -20°C 20°C 0°C
Fungsi kontrol injeksi
Maks. Nilai referensi superheat (ekspansi garing) n09 1 1 1 1 1 1 1 1 1 1 2°C 20°C 12
Min. Nilai referensi superheat (ekspansi garing) n10 1 1 1 1 1 1 1 1 1 1 2°C 20°C 3
suhu MOP. Off yen suhu MOP. = 15.0 °C n11 1 1 1 1 1 1 1 1 1 1 -50°C 15°C 15
Periode wektu pulsation AKV Mung kanggo personel terlatih n13 1 1 1 1 1 1 1 1 1 1 3 sek 6 sek 6
Watesan maksimal referensi superheat nalika Banjir diaktifake P86 1 1 1 1 1 1 1 1 1 1 1°C 20°C 3
Watesan minimal saka referensi superheat nalika Banjir diaktifake P87 1 1 1 1 1 1 1 1 1 1 0°C 20°C 1
Penggemar
Suhu mandeg kipas (S5) F04 1 1 1 1 1 1 1 1 1 1 -50°C 50°C 50
Operasi pulsa ing kipas: 0 = Ora ana operasi pulsa, 1 = Ing termostat mung dipotong, 2 = Mung nalika termostat dipotong nalika operasi wengi F05 1 1 1 1 1 1 1 1 1 1 0 2 0
Periode wektu kanggo pulsasi kipas (on-time + off-time) F06 1 1 1 1 1 1 1 1 1 1 1 min. 30 min. 5
On-wektu ing% wektu wektu F07 1 1 1 1 1 1 1 1 1 1 0 % 100 % 100
Jam wektu nyata
Enem wiwitan kaping kanggo defrost. Setelan jam.
0 = MATI
t01 -t06 1 1 1 1 1 1 1 1 1 1 0 jam 23 jam 0
Enem wiwitan kaping kanggo defrost. Setelan menit.
0 = MATI
t11 -t16 1 1 1 1 1 1 1 1 1 1 0 min. 59 min. 0
Jam - Setelan jam t07 1 1 1 1 1 1 1 1 1 1 0 jam 23 jam 0
Jam - Setelan menit t08 1 1 1 1 1 1 1 1 1 1 0 min. 59 min. 0
Jam - Setelan tanggal t45 1 1 1 1 1 1 1 1 1 1 1 dina 31 dina 1
Jam - Setelan sasi t46 1 1 1 1 1 1 1 1 1 1 1 wulan. 12 wulan. 1
Jam - Setelan taun t47 1 1 1 1 1 1 1 1 1 1 0 taun 99 taun 0
macem-macem
Wektu tundha sinyal output sawise gagal daya o01 1 1 1 1 1 1 1 1 1 1 0 sek 600 sek 5
Sinyal input ing DI1. Fungsi:
0 = ora digunakake. 1 = status ing DI1. 2 = fungsi lawang karo weker nalika mbukak. 3 = weker lawang nalika mbukak. 4 = wiwitan defrost (sinyal pulsa). 5 = ext. ngalih utama. 6 = operasi wengi 7 = owah-owahan band termostat (aktif r21). 8 = fungsi weker nalika ditutup. 9 = fungsi weker nalika mbukak. 10 = reresik kasus (sinyal pulsa). 11 = cooling paksa ing defrost gas panas, 12 = tutup wengi. 15 = piranti mati. 20 = weker bocor refrigerant. 21 = ngaktifake banjir.
o02 1 1 1 1 1 1 1 1 1 1 0 21 0
Alamat jaringan o03 1 1 1 1 1 1 1 1 1 1 0 240 0
Switch On/Off (Pesen Pin Layanan) PENTING! o61 kudu disetel sadurunge o04 (mung digunakake ing LON 485) o04 1 1 1 1 1 1 1 1 1 1 0/Pateni 1 / Ing 0/Pateni
Kode akses 1 (kabeh setelan) o05 1 1 1 1 1 1 1 1 1 1 0 100 0
Tipe sensor sing digunakake: 0 = Pt1000, 1 = Ptc1000, o06 1 1 1 1 1 1 1 1 1 1 0/Pt 1/Ptc 0/Pt
Wektu ditahan maksimal sawise defrost terkoordinasi o16 1 1 1 1 1 1 1 1 1 1 0 min. 360 min. 20
Pilih sinyal kanggo tampilan view. S4% (100%=S4, 0%=S3) o17 1 1 1 1 1 1 1 1 1 1 0 % 100 % 100
Rentang kerja pemancar tekanan - min. nilai o20 1 1 1 1 1 1 1 1 1 1 -1 bar 5 bar -1
Rentang kerja pemancar tekanan - maks. nilai o21 1 1 1 1 1 1 1 1 1 1 6 bar 200 bar 12
Terus Kode 1 2 3 4 5 6 7 8 9 10 Min. Maks. Fac. nyatane
Setelan refrigerant:

1=R12. 2=R22. 3=R134a. 4=R502. 5=R717. 6=R13.
7=R13b1. 8=R23. 9=R500. 10=R503. 11=R114.
12=R142b. 13=Panganggo ditetepake. 14=R32. 15=R227.
16=R401A. 17=R507. 18=R402A. 19=R404A. 20=R407C.
21=R407A. 22=R407B. 23=R410A. 24=R170. 25=R290.
26=R600. 27=R600a. 28=R744. 29=R1270. 30=R417A.
31=R422A. 32=R413A. 33=R422D. 34=R427A. 35=R438A.
36=R513A. 37=R407F. 38=R1234ze. 39=R1234yf.
40=R448A. 41=R449A. 42=R452A

o30 1 1 1 1 1 1 1 1 1 1 0 42 0
Sinyal input ing DI2. Fungsi:

(0 = ora digunakake. 1 = status ing DI2. 2 = fungsi lawang karo weker nalika mbukak. 3 = weker lawang nalika mbukak. 4 = defrost wiwitan (pulsa-sinyal). 5 = ext. switch utama 6 = operasi wengi 7 = band termostat changeover (aktif r21) 8 = fungsi weker nalika ditutup. 9 = fungsi weker nalika mbukak.
10 = reresik kasus (sinyal pulsa). 11 = pendinginan paksa ing defrost gas panas.). 12 = tutup wengi, 13 = defrost terkoordinasi). 15 = piranti mati. 20 = weker bocor refrigerant.
21 = ngaktifake banjir.

o37 1 1 1 1 1 1 1 1 1 1 0 21 0
Konfigurasi fungsi cahya: 1 = Cahya nderek operasi awan / wengi, 2 = Kontrol cahya liwat komunikasi data liwat 'o39', 3 = Kontrol cahya nganggo input DI, 4 = Minangka "2", nanging ngalih lampu lan tutup wengi bakal mbukak yen jaringan dipotong luwih saka 15 menit. o38 1 1 1 1 1 1 1 1 1 4 1
Aktifake relay cahya (mung yen o38=2) On = cahya o39 1 1 1 1 1 1 1 1 0/Pateni 1 / Ing 0/Pateni
Panas rel On wektu sak operasi dina o41 1 1 1 1 1 1 1 0 % 100 % 100
Panas rel On wektu sak operasi wengi o42 1 1 1 1 1 1 1 0 % 100 % 100
Wektu panas rel (Waktu On + Wektu Off) o43 1 1 1 1 1 1 1 6 min. 60 min. 10
Reresik kasus. 0 = ora ngresiki kasus. 1 = Mung penggemar. 2=Kabeh output Mati. *** o46 1 1 1 1 1 1 1 1 1 1 0 2 0
Pamilihan diagram EL. Waca liwatview kaca 12 lan 13 * o61 1 1 1 1 1 1 1 1 1 1 1 10 1
Ngundhuh sakumpulan setelan sing wis ditemtokake. Waca liwatview kaca 27. * o62 1 1 1 1 1 1 1 1 1 1 0 6 0
Kode akses 2 (akses parsial) *** o64 1 1 1 1 1 1 1 1 1 1 0 100 0
Ganti setelan pabrik pengontrol karo setelan saiki o67 1 1 1 1 1 1 1 1 1 1 0/Pateni 1 / Ing 0/Pateni
Sinyal input ing DI3. Fungsi: (voltage masukan)
(0 = ora digunakake. 1 = status ing DI2. 2 = fungsi lawang karo weker nalika mbukak. 3 = weker lawang nalika mbukak. 4 = defrost wiwitan (pulse-sinyal). 5 = ext. switch utama 6 = wengi operasi, 7 = band termostat changeover (aktif r21). 8 = Ora digunakake. 9 = Ora digunakake (sinyal pulsa).
11 = cooling paksa ing defrost gas panas, 12 = tutup wengi.
13 = Ora digunakake. 14 = Pendinginan mandheg (ditutup kanthi paksa)). 15 = piranti mati. 21 = ngaktifake banjir.
o84 1 1 1 1 1 1 1 1 1 1 0 21 0
Kontrol panas rel
0 = ora digunakake, 1 = kontrol pulsa kanthi fungsi timer (o41 lan o42), 2 = kontrol pulsa kanthi fungsi titik embun
o85 1 1 1 1 1 1 1 0 2 0
Nilai titik embun ing ngendi panas rel minimal o86 1 1 1 1 1 1 1 -10°C 50°C 8
Nilai titik embun ing ngendi panas rel 100% ing o87 1 1 1 1 1 1 1 -9°C 50°C 17
Efek panas rel paling murah ing% o88 1 1 1 1 1 1 1 0 % 100 % 30
Wektu tundha saka "lawang mbukak" kulkas diwiwiti o89 1 1 1 1 1 1 1 1 1 1 0 min. 240 min. 30
Operasi kipas ing refrigerasi mandheg (ditutup paksa):
0 = mandheg (defrosting diijini)
1 = Mlaku (defrosting diijini)
2 = Mandheg (defrosting ora diijini)
3 = Mlaku (defrosting ora diijini)
o90 1 1 1 1 1 1 1 1 1 1 0 3 1
Definisi maca ing tombol ngisor:
1 = suhu stop defrost, 2 = suhu S6, 3 = suhu S3, 4 = suhu S4
o92 1 1 1 1 1 1 1 1 1 1 1 3 1
Tampilan suhu
1= u56 Suhu udara (setel otomatis dadi 1 ing aplikasi 9)
2 = u36 suhu produk
o97 1 1 1 1 1 1 1 1 1 1 1 2 1
Werna cahya lan wengi ditetepake

0: Lampu dipateni lan wuta wengi mbukak nalika saklar utama mati
1: Cahya lan wuta wengi ora gumantung saka saklar utama

o98 1 1 1 1 1 1 1 1 1 1 0 1 0
Terus Kode 1 2 3 4 5 6 7 8 9 10 Min. Maks. Fac. nyatane
Konfigurasi relay weker
Relay weker bakal diaktifake nalika sinyal weker saka klompok ing ngisor iki:
0 - Relay weker ora digunakake
1 - Weker suhu dhuwur
2 - Weker suhu rendah 4 - Kesalahan sensor
8 - Input digital diaktifake kanggo weker 16 - Weker defrosting
32 - Aneka 64 - Weker injeksi
Klompok sing arep ngaktifake relay weker kudu disetel kanthi nggunakake angka numerik sing minangka jumlah saka grup sing kudu diaktifake.
(Contone: nilai 5 bakal ngaktifake kabeh weker suhu dhuwur lan kabeh kesalahan sensor.
P41 1 1 1 1 1 0 127 111
Layanan
Suhu diukur nganggo sensor S5 u09 1 1 1 1 1 1 1 1 1 1 *) Mung bisa disetel nalika regulasi mandheg (r12=0)
**) Bisa dikontrol kanthi manual, nanging mung nalika r12 = -1
***) Kanthi kode akses 2 akses menyang menu iki bakal winates Setelan Pabrik dituduhake kanggo unit standar. Nomer kode liyane duwe setelan khusus.
Status ing input DI1. ing / 1 = ditutup u10 1 1 1 1 1 1 1 1 1 1
Wektu defrost nyata (menit) u11 1 1 1 1 1 1 1 1 1 1
Suhu diukur nganggo sensor S3 u12 1 1 1 1 1 1 1 1 1 1
Status ing operasi wengi (urip utawa mati) 1=on u13 1 1 1 1 1 1 1 1 1 1
Suhu diukur nganggo sensor S4 u16 1 1 1 1 1 1 1 1 1 1
Suhu termostat u17 1 1 1 1 1 1 1 1
Wektu kerja termostat (wektu pendinginan) ing menit u18 1 1 1 1 1 1 1 1 1 1
Suhu outlet evaporator. u20 1 1 1 1 1 1 1 1 1 1
Superheat liwat evaporator u21 1 1 1 1 1 1 1 1 1 1
Referensi kontrol superheat u22 1 1 1 1 1 1 1 1 1 1
Tingkat bukaan katup AKV ** u23 1 1 1 1 1 1 1 1 1 1
Tekanan penguapan Po (relatif) u25 1 1 1 1 1 1 1 1 1 1
Suhu evaporator Kanggo (diwilang) u26 1 1 1 1 1 1 1 1 1 1
Suhu diukur nganggo sensor S6 (suhu produk) u36 1 1 1 1 1 1 1 1 1
Status ing output DI2. ing / 1 = ditutup u37 1 1 1 1 1 1 1 1 1 1
Suhu hawa. Bobot S3 lan S4 u56 1 1 1 1 1 1 1 1 1 1
Suhu sing diukur kanggo termostat weker u57 1 1 1 1 1 1 1 1 1 1
Status ing relay kanggo cooling ** u58 1 1 1 1
Status ing relay kanggo penggemar ** u59 1 1 1 1 1 1 1 1 1 1
Status ing relay kanggo defrost ** u60 1 1 1 1 1 1 1 1 1
Status ing relay kanggo panas rel ** u61 1 1 1 1 1 1 1
Status ing relay kanggo weker ** u62 1 1 1 1 1
Status ing relay kanggo cahya ** u63 1 1 1 1 1 1 1 1
Status ing relay kanggo katup ing garis nyedhot ** u64 1
Status ing relay kanggo kompresor 2 ** u67 1
Suhu diukur nganggo sensor S5B u75 1
Suhu diukur nganggo sensor S3B u76 1 1
Status ing relay kanggo gas panas- / katup saluran ** u80 1
Status ing relay kanggo unsur panas ing tray netes ** u81 1
Status ing relay kanggo tirai wengi ** u82 1
Status ing relay kanggo defrost B ** u83 1
Status ing relay kanggo fungsi panas ** u84 1
Waca efek panas rel sing nyata u85 1 1 1 1 1 1 1
1: Thermostat 1 operasi, 2: Thermostat 2 operasi u86 1 1 1 1 1 1 1 1 1 1
Status ing dhuwur voltage input DI3 u87 1 1 1 1 1 1 1 1 1 1
Pembacaan termostat sing dipotong nyata u90 1 1 1 1 1 1 1 1 1 1
Pembacaan termostat nilai potong nyata u91 1 1 1 1 1 1 1 1 1 1
Waca status ing defrost adaptif
0: uwal. Fungsi ora diaktifake lan nul pesawat 1: kesalahan Sensor utawa S3 / S4 kuwalik.
2: Tuning lagi ditindakake 3: Normal
4: Cahya mbangun-up saka es
5: Sedheng build-up saka es 6: heavy build-up saka es
U01 1 1 1 1 1 1 1 1 1 1
Jumlah defrosts digawa metu wiwit wiwitan daya munggah utawa wiwit ngreset fungsi U10 1 1 1 1 1 1 1 1 1 1
Jumlah defrosts dilewati wiwit wiwitan daya munggah utawa wiwit ngreset fungsi U11 1 1 1 1 1 1 1 1 1 1
Suhu sing diukur kanggo termostat weker ing bagean B U34 1 1
Suhu udara ing bagean B U35 1 1
Pesen kesalahan
Ing kahanan kesalahan, LED ing ngarep bakal sumunar lan relay weker bakal diaktifake. Yen sampeyan menet tombol ndhuwur ing kahanan iki sampeyan bisa ndeleng laporan weker ing tampilan. Ana rong jinis laporan kesalahan - bisa dadi weker sing kedadeyan sajrone operasi saben dina, utawa bisa uga ana cacat ing instalasi. Weker A ora bakal katon nganti wektu tundha sing disetel wis kadaluwarsa. E-weker, ing sisih liya, bakal katon nalika ana kesalahan. (Weker A ora bakal katon anggere ana weker E aktif).
Iki pesen sing bisa katon:
Kode / teks weker liwat komunikasi data Katrangan Grup relay weker (P41)
A1/— Dhuwur t. weker Weker suhu dhuwur 1
A2/— Kurang t. weker Weker suhu rendah 2
A4/— Weker lawang Weker lawang 8
A5/— Wektu ditahan maksimal Fungsi "o16" diaktifake sajrone defrost sing terkoordinasi 16
A10/- Inject prob. Masalah kontrol 64
A11/— Ora Rfg. sel. Ora ana refrigeran sing dipilih 64
A13/— Suhu dhuwur S6 Weker suhu. Dhuwur S6 1
A14/— Suhu rendah S6 Weker suhu. Kurang S6 2
Weker A15/- DI1 weker DI1 8
Weker A16/- DI2 weker DI2 8
A45/— Mode siyaga Posisi siyaga (mandheg kulkas liwat input r12 utawa DI)
A59/— Kasus resik Reresik kasus. Sinyal saka input DI
A70/— Suhu dhuwur S3B Weker suhu dhuwur, bagean B 1
A71/— Suhu rendah S3B Weker suhu rendah, bagean B 2
AA2/— Refg. bocor Weker bocor refrigerant 8
Weker AA3/- CO2 weker bocor CO2 8
- kesalahan AD Kesalahan ing fungsi defrost adaptif 16
- AD Iced Evaporator wis es munggah. Ngurangi aliran udara 16
- AD ora defr. Defrost saka evaporator ora marem 16
- gas lampu kilat AD. Gas kilat dibentuk ing katup 16
E1/— Ctrl. kesalahan Faults ing controller 32
E6/— kesalahan RTC Priksa jam 32
E20/- Pe kesalahan Kesalahan ing pemancar tekanan Pe 64
E24/- kesalahan S2 Kesalahan ing sensor S2 4
E25/- kesalahan S3 Kesalahan ing sensor S3 4
E26/- kesalahan S4 Kesalahan ing sensor S4 4
E27/- kesalahan S5 Kesalahan ing sensor S5 4
E28/- kesalahan S6 Kesalahan ing sensor S6 4
E34/- S3 kesalahan B Error ing sensor S3B 4
E37/- S5 kesalahan B Error ing sensor S5B 4
—/— Maks Def. Wektu Defrost mandheg adhedhasar wektu tinimbang, kaya sing dikarepake, ing suhu 16
Status operasi (Pengukuran)
Controller dadi liwat sawetara kahanan ngatur ngendi iku mung nunggu titik sabanjuré saka angger-angger. Kanggo nggawe kahanan "kenapa ora kedadeyan" katon, sampeyan bisa ndeleng status operasi ing layar. Pencet sedhela (1s) tombol ndhuwur. Yen ana kode status, bakal ditampilake ing tampilan. Kode status individu nduweni makna ing ngisor iki: Ctrl. negara: (Katon ing kabeh tampilan menu)
Angger normal S0 0
Nunggu pungkasan defrost terkoordinasi S1 1
Nalika kompresor digunakake, kudu mlaku paling sethithik x menit. S2 2
Nalika kompresor mandheg, iku kudu tetep mandeg paling sethithik x menit. S3 3
Evaporator netes lan ngenteni wektu entek S4 4
Pendinginan mandheg kanthi ngalih utama. Salah siji karo r12 utawa DI-input S10 10
Pendinginan mandheg kanthi termostat S11 11
Urutan defrost. Defrost ing proses S14 14
Urutan defrost. Fan tundha - banyu attaches kanggo evaporator ing S15 15
Kulkas mandheg amarga input ON mbukak utawa regulasi mandheg S16 16
Lawang mbukak. Input DI mbukak S17 17
Fungsi leleh ing proses. Pendinginan diselani S18 18
Modulasi kontrol termostat S19 19
Pendinginan darurat amarga kesalahan sensor *) S20 20
Masalah regulasi ing fungsi injeksi S21 21
Fase wiwitan 2. Evaporator diisi S22 22
Kontrol adaptif S23 23
Fase wiwitan 1. Keandalan sinyal saka sensor dikontrol S24 24
Kontrol output manual S25 25
Ora ana refrigeran sing dipilih S26 26
Reresik kasus S29 29
Pendinginan dipeksa S30 30
Tundha ing output nalika wiwitan S32 32
Fungsi panas r36 aktif S33 33
Mateni piranti S45 45
Banjir evap. fungsi aktif S48 48
Tampilan liyane:
Suhu defrost ora bisa ditampilake. Ana mandeg adhedhasar wektu ora
Defrost ing proses / pisanan cooling sawise defrost -d-
Sandi dibutuhake. Setel sandhi PS
Regulasi mandheg liwat switch utama OFF

*) Pendinginan darurat bakal ditrapake yen ana kekurangan sinyal saka sensor S3 utawa S4 sing ditemtokake. Angger-angger bakal terus karo Cut rata-rata kadhaptar ing frekuensi. Ana rong nilai kadhaptar - siji kanggo operasi dina lan siji kanggo operasi wengi.

Komunikasi data
Pentinge weker individu bisa ditetepake kanthi setelan. Setelan kasebut kudu ditindakake ing grup "Tujuan weker"

Setelan saka
Manajer sistem
Setelan saka
AKM (tujuan AKM)
Log Relay weker Kirim liwat
Jaringan
Non dhuwur Sedheng-Dhuwur
dhuwur 1 X X X X
agêng 2 X X X
kurang 3 X X X
Log wae X
dipatèni

FAQ

  1. Apa jinis kabel sing kudu digunakake kanggo sambungan komunikasi data?
    A: Sambungan MODBUS, DANBUSS, lan RS485 komunikasi data kudu tundhuk karo syarat kabel komunikasi data. Waca literatur: RC8AC kanggo rincian.
  2. Pira pengontrol sing bisa nampa sinyal saka siji pemancar tekanan?
    A: Sinyal saka siji pemancar tekanan bisa ditampa nganti 10 pengontrol, yen ora ana penurunan tekanan sing signifikan ing antarane evaporator sing bakal dikontrol.
  3. Apa spesifikasi kanggo sumber daya?
    A: Produk mbutuhake vol pasokantage saka 230 V ac, 50/60 Hz.