Danfoss-LOGO

Danfoss 80G8429 Case Controller Tipe EKC 224

Danfoss-80G8429-Case-Controller-Type-EKC-224-PRODUCT

Spesifikasi

  • Model: Pengontrol kasus Tipe EKC 224
  • Sumber Daya: 115 V AC / 230 V AC, 50/60 Hz
  • Daya Rated: Kurang saka 0.7 W
  • Input: Input Sensor, Input Digital, Tombol Pemrograman
  • Tipe Sensor sing Diidini: SELV energi winates

Pandhuan Panggunaan Produk

Instalasi

  • Deleng pandhuan instalasi kanggo langkah-langkah rinci babagan pemasangan lan nyopot pengontrol. Priksa manawa kabel sing tepat adhedhasar diagram kabel sing kasedhiya.

Komunikasi Data

  • Kontroler EKC 22x bisa digabungake menyang jaringan Modbus liwat adaptor RS-485 (EKA 206) nggunakake kabel antarmuka (080N0327). Tindakake pandhuan instalasi kanggo EKA 206 kanggo instruksi instalasi sing rinci.

Wiring

  • Tindakake diagram kabel sing kasedhiya kanggo nyambungake controller menyang sumber daya lan sensor. Gunakake kabel lan konektor sing cocog kanggo sambungan sing aman.

Antarmuka

  • Kanggo komunikasi data, gunakake adaptor RS-485 (EKA 206) lan kabel antarmuka (080N0327) kaya sing wis ditemtokake. Priksa konfigurasi sing tepat kanggo integrasi sing lancar menyang jaringan Modbus.

Fitur Controller

  • Tujuan Kontrol: Kontrol sensing suhu operasi kanggo aplikasi AC lan kulkas
  • Konstruksi: Kontrol tergabung karo vol rendah terisolasi galvaniktage sumber daya diatur
  • Akurasi: Kontrol tliti dhuwur kanthi konsumsi daya kurang saka 0.7 W

FAQ

  • P: Kepiye carane nginstal controller?
    • A: Kontroler bisa dipasang kanthi nggunakake dipasang ing mburi kanthi klip kaya sing dituduhake ing bagean dimensi manual.
  • P: Apa jinis input sing didhukung dening pengontrol?
    • A: Kontroler ndhukung input sensor, input digital, lan input tombol pemrograman, disambungake menyang sumber energi sing diwatesi SELV.

Identifikasi

Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-1

Aplikasi

Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-2

ukuran

Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-3

Pemasangan

Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-4

Wiring diagram

Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-5

  • Cathetan: Konektor daya: ukuran kawat = 0.5 – 1.5 mm2, maks. torsi nyenyet = 0.4 Nm
  • Low Voltagkonektor sinyal e: ukuran kabel = 0.15 – 1.5 mm2, maks. torsi tightening = 0.2 Nm 2L lan 3L kudu disambungake menyang phase padha.

Komunikasi data

InstalasiDanfoss-80G8429-Case-Controller-Type-EKC-224-FIG-6

  • Kontroler EKC 22x bisa digabungake menyang jaringan Modbus liwat adaptor RS-485 (EKA 206) nggunakake kabel antarmuka (080N0327).
  • Kanggo rincian instalasi, waca pandhuan instalasi kanggo adaptor EKA 206 – RS485.

WiringDanfoss-80G8429-Case-Controller-Type-EKC-224-FIG-7

data teknis

Fitur Katrangan
Tujuan kontrol Kontrol sensing suhu operasi sing cocog kanggo digabungake menyang aplikasi AC lan kulkas komersial
Konstruksi kontrol Kontrol tergabung
sumber daya 084B4055 – 115 V AC / 084B4056 – 230 V AC

50/60 Hz, galvanik diisolasi low voltage sumber daya diatur

daya dirating Kurang saka 0.7 W
Input Input sensor, Input digital, Tombol Pemrograman Disambungake menyang energi winates SELV <15 W
Jinis sensor sing diidini NTC 5000 Ohm ing 25 °C, (Nilai Beta=3980 ing 25/100 °C – EKS 211) NTC 10000 Ohm ing 25 °C, (Nilai Beta=3435 ing 25/85 °C – EKS 221) PTC 990 Ohm ing 25 °C, (EKS 111)

Pt1000, (AKS 11, AKS 12, AKS 21)

Akurasi Rentang pangukuran: -40 – 105 °C (-40 – 221 °F)
Akurasi Controller:

± 1 K ing ngisor -35 °C, ± 0.5 K antarane -35 – 25 °C,

± 1 K ing ndhuwur 25 °C

Jinis tumindak 1B (relay)
Output DO1 - Relay 1:

16 A, 16 (16) A, EN 60730-1

10 FLA / 60 LRA ing 230 V, UL60730-1

16 FLA / 72 LRA ing 115 V, UL60730-1

DO2 - Relay 2:

8 A, 2 FLA / 12 LRA, UL60730-1

8 A, 2 (2 A), EN60730-1

DO3 - Relay 3:

3 A, 2 FLA / 12 LRA, UL60730-1

3 A, 2 (2 A), EN60730-1

DO4 – Relay 4: 2 A
Tampilan Tampilan LED, 3 digit, titik desimal lan lambang multi-fungsi, skala °C + °F
kahanan operasi -10 – 55 °C (14 – 131 °F), 90% Rh
Kondisi panyimpenan -40 – 70 °C (-40 – +158 °F), 90% Rh
pangayoman Ngarep: IP65 (Gasket terpadu) Mburi: IP00
lingkungan Tingkat polusi II, non-kondensasi
Overvoltage kategori II – 230 V versi sumber – (ENEC, UL dikenali) III – 115 V versi sumber – (UL dikenali)
Resistance kanggo panas lan geni Kategori D (UL94-V0)

Suhu kanggo statement tes tekanan bola Miturut Annex G (EN 60730-1)

Kategori EMC Kategori I
Persetujuan Pangenalan UL (AS & Kanada) (UL 60730-1) CE (Arahan LVD & EMC)

EAC (HANTU) UKCA

UA CMIM ROHS2.0

Persetujuan Hazloc kanggo refrigeran sing gampang kobong (R290/R600a).

Aplikasi pungkasan R290 / R600a sing digunakake miturut syarat IEC60079-15.

Operasi tampilan

Tombol ing ngarep tampilan bisa dioperasikake kanthi mencet cendhak lan dawa (3s).Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-8

A Indikasi status: LED murup ing mode ECO/Night, cooling, defrost, ing, lan kipas mlaku.
B Indikasi weker: Weker lambang kelip-kelip yen ana weker.
C Pencet singkat = Navigasi bali

Tekan dawa = Miwiti siklus pulldown. Tampilan bakal nuduhake "Pud" kanggo konfirmasi wiwitan.

D Pencet singkat = Navigasi munggah

Tekan dawa = Ngalih pengontrol ON/OFF (nyetel r12 Switch utama ing posisi ON/OFF)

E Pencet singkat = Navigasi mudhun

Tekan dawa = Miwiti siklus defrosting. Tampilan bakal nuduhake kode "-d-" kanggo konfirmasi wiwitan.

F Pencet singkat = Ngganti set point

Tekan dawa = Menyang menu parameter

View weker:

  • Kode suhu lan weker gantian ˛awu nganti weker rampung. Lonceng weker ˛awu nalika kondisi weker.Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-9

Kunci keyboard:

  • Sawise 5 menit ora ana aktivitas, keypad dikunci (yen P76=ya).
  • Nalika keypad dikunci sembarang tombol pencet nuduhake "LoC" ing tampilan.
  • Pencet tombol UP lan DOWN bebarengan sajrone 3 detik kanggo mbukak kunci keyboard. "nganti" ditampilake kanggo 3 s

Reset pabrik

Kontroler bisa diset bali menyang setelan pabrik kanthi nggunakake prosedur ing ngisor iki.

  1. Kontrol daya OFF
  2. Terus tombol panah "∧" lan mudhun "∨" ditekan nalika nyambungake maneh sumber voltage
  3. Nalika kode "Fac" ditampilake ing tampilan, pilih "ya

Cathetan: Setelan pabrik OEM bakal dadi setelan pabrik Danfoss utawa setelan pabrik sing ditolak pangguna yen wis digawe. Pangguna bisa nyimpen setelan kasebut minangka setelan pabrik OEM liwat parameter o67.

Kode tampilan

Tampilan kode Katrangan
-d- Siklus defrost lagi ditindakake
Pud Siklus pulldown suhu wis diwiwiti
Kesalahan Suhu ora bisa ditampilake amarga kesalahan sensor
Dituduhake ing sisih ndhuwur tampilan: Nilai parameter wis tekan maksimal. watesan
Ditampilake ing sisih ngisor tampilan: Nilai parameter wis tekan min. watesan
Loc Papan tombol tampilan dikunci
URL Papan tombol tampilan wis ora dikunci
PS Kode akses dibutuhake kanggo ngetik menu parameter
Axx/Exx Weker utawa kode kesalahan sumunar kanthi suhu normal. wacan
OFF Kontrol mandegake nalika r12 ngalih Utama disetel OFF
On Kontrol diwiwiti nalika switch utama r12 disetel ON (kode ditampilake ing 3 detik)
Fac Kontroler direset menyang setelan pabrik

Pandhu arah

  • Menu parameter diakses kanthi mencet tombol "SET" kanggo 3 detik. Yen kode proteksi akses "o05" wis ditolak, tampilan bakal njaluk kode akses kanthi nuduhake kode "PS".
  • Sawise kode akses wis diwenehake dening pangguna, dhaptar parameter bakal diakses.Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-10

Entuk wiwitan sing apik

Kanthi prosedur ing ngisor iki, sampeyan bisa miwiti regulasi kanthi cepet.

  1. Pencet tombol "SET" kanggo 3 detik lan ngakses menu parameter (tampilan bakal nuduhake "ing")
  2. Pencet tombol mudhun "∨" kanggo pindhah menyang menu "cFg" (tampilan bakal nuduhake "cFg")
  3. Pencet tombol tengen/">" kanggo mbukak menu conÿguration (tampilan bakal nuduhake r12)
  4. Bukak parameter "r12 Main switch" lan mungkasi kontrol kanthi nyetel OFF (Pencet SET)
  5. Bukak "mode aplikasi o61" lan pilih mode aplikasi sing dibutuhake (Pencet SET)
  6. Bukak "jinis Sensor o06" lan pilih jinis sensor suhu sing digunakake (n5 = NTC 5 K, n10 = NTC 10 K, Ptc = PTC, Pt1 = Pt1000) - (Pencet "SET").
  7. Bukak "O02 DI1 Conÿguration" lan pilih fungsi sing ana gandhengane karo input digital 1 (Mangga deleng dhaptar parameter) - (Pencet "SET").
  8. Bukak "O37 DI2 Conÿguration" lan pilih fungsi sing ana gandhengane karo input digital 2 (Mangga deleng dhaptar parameter) - (Pencet "SET").
  9. Bukak parameter "o62 Quick setting" lan pilih prasetel sing ÿts karo aplikasi sing digunakake (waca tabel prasetel ing ngisor iki) - (Pencet "SET").
  10. Bukak "alamat Jaringan o03" lan setel alamat Modbus yen dibutuhake.
  11. Navigasi bali menyang parameter "r12 Main switch" lan nyetel ing posisi "ON" kanggo miwiti kontrol.
  12. Bukak kabeh dhaptar parameter lan ganti setelan pabrik yen perlu.

Pamilihan setelan cepet

Cepet setelan 1 2 3 4 5 6 7
  Kabinet MT Natural def. Mungkasi ing wektu Kabinet MT El. def.

Mungkasi ing wektu

Kabinet MT El. def.

Mungkasi ing suhu

Kabinet LT El. def.

Mungkasi ing suhu

kamar MT El. def.

Mungkasi ing wektu

kamar MT El. def.

Mungkasi ing suhu

Kamar LT El. def.

Mungkasi ing suhu

r00 Cut-out 4 °C 2 °C 2 °C -24 °C 6 °C 3 °C -22 °C
r02 Max Cut-out 6 °C 4 °C 4 °C -22 °C 8 °C 5 °C -20 °C
r03 Min Cut-out 2 °C 0 °C 0 °C -26 °C 4 °C 1 °C -24 °C
A13 HighLim Air 10 °C 8 °C 8 °C -15 °C 10 °C 8 °C -15 °C
A14 LowLim Air -5 °C -5 °C -5 °C -30 °C 0 °C 0 °C -30 °C
d01 Def. Metode Alamiah listrik listrik listrik listrik listrik listrik
d03 Def.Interval 6 jam 6 jam 6 jam 12 jam 8 jam 8 jam 12 jam
d10 DefStopSens. Wektu Wektu S5 Sensor Kab S5 Sensor Kab Wektu S5 Sensor Kab S5 Sensor Kab
o02 DI1 Konfigurasi.         Lawang FCT. Lawang FCT. Lawang FCT.

Tombol pemrograman

Pengontrol pemrograman dengan Mass Programming Key (EKA 201)

  1. Daya munggah controller. Priksa manawa pengontrol disambungake menyang listrik.
  2. Sambungake EKA 201 menyang controller nggunakake kabel antarmuka controller pamilike.
  3. EKA 201 bakal miwiti proses pemrograman kanthi otomatis.Danfoss-80G8429-Case-Controller-Type-EKC-224-FIG-11

Daftar parameter

Kode Manual teks singkat  

Min.

 

Maks.

 

Def.

 

Unit

 

R/W

EKC 224 Appl.
1 2 3 4
CFg Konfigurasi
r12 Saklar utama (-1 = layanan / 0 = OFF / 1 = ON) -1 1 0   R/W * * * *
o611) Pilihan saka mode aplikasi

(1) AP1: Cmp/Def/Fan/Lampu

(2) AP2: Cmp/Def/Fan/Weker

(3) AP3: Cmp/Al/Kipas angin/Lampu

(4) AP4: Panas / Weker / Cahya

1 4 1   R/W * * * *
o061) Pilihan jinis sensor

(0) n5 = NTC 5k, (1) n10 = NTC 10k, (2) Pt = Pt1000, (3) Ptc = PTC 1000

0 3 2   R/W * * * *
o021) konfigurasi DI1

(0) OFF= ora digunakake, (1) Sdc= status, (2) dhuh= fungsi lawang, (3)

doA= weker lawang, (4) SCH= saklar utama,

(5) nig= mode awan/wengi, (6) rFd= pamindahan referensi,

(7) EAL= weker eksternal, (8) dEF= defrost,

(9) Pud= narik mudhun, (10) Sc= sensor kondensor

0 10 0   R/W * * * *
o371) konfigurasi DI2

(0) OFF= ora digunakake, (1) Sdc= status, (2) dhuh= fungsi lawang, (3)

doA= weker lawang, (4) SCH= saklar utama,

(5) nig= mode awan/wengi, (6) rFd= pamindahan referensi,

(7) EAL= weker eksternal, (8) dEF= defrost,

(9) Pud= narik mudhun

0 9 0   R/W * * * *
o621) Prasetel cepet paramèter utama 0 = Ora digunakake

1 = MT, Defrost alami, mandheg ing wektu 2 = MT, El defrost, mandheg ing wektu

3 = MT, El defrost, mandheg ing suhu. 4 = LT, El defrost, mandheg ing suhu.

5 = Kamar, MT, El defrost, mandheg ing wektu 6 = Kamar, MT, El defrost, mandheg ing suhu.

7 = Kamar, LT, El defrost, mandheg ing suhu.

0 7 0   R/W * * *  
o031) Alamat jaringan 0 247 0   R/W * * * *
r– Thermostat
r00 Setpoint suhu r03 r02 2.0 °C R/W * * * *
r01 Dierential 0.1 20.0 2.0 K R/W * * * *
r02 Maks. watesan setelan setpoint r03 105.0 50.0 °C R/W * * * *
r03 Min. watesan setelan setpoint -40.0 r02 -35.0 °C R/W * * * *
r04 Pangaturan maca suhu tampilan -10.0 10.0 0.0 K R/W * * * *
r05 Unit suhu (°C / °F) 0 / C 1 / F 0 / C   R/W * * * *
r09 Koreksi sinyal saka sensor Sair -20.0 20.0 0.0 °C R/W * * * *
r12 Saklar utama (-1 = layanan / 0 = OFF / 1 = ON) -1 1 0   R/W * * * *
r13 Pamindahan referensi sajrone operasi wengi -50.0 50.0 0.0 K R/W * * * *
r40 Pamindahan referensi termostat -50.0 20.0 0.0 K R/W * * * *
r96 Pull-mudhun durasi 0 960 0 min R/W * * *  
r97 Pull-mudhun suhu watesan -40.0 105.0 0.0 °C R/W * * *  
A– Weker setelan
A03 Tundha kanggo weker suhu (singkat) 0 240 30 min R/W * * * *
A12 Tundha kanggo weker suhu nalika mundur (dawa) 0 240 60 min R/W * * * *
A13 watesan weker dhuwur -40.0 105.0 8.0 °C R/W * * * *
A14 watesan weker kurang -40.0 105.0 -30.0 °C R/W * * * *
A27 Tundha weker DI1 0 240 30 min R/W * * * *
A28 Tundha weker DI2 0 240 30 min R/W * * * *
A37 Watesan weker kanggo weker suhu kondensor 0.0 200.0 80.0 °C R/W * * *  
Kode Manual teks singkat  

Min.

 

Maks.

 

Def.

 

Unit

 

R/W

EKC 224 Appl.
1 2 3 4
A54 Watesan kanggo weker blok kondensor lan komp. mandeg 0.0 200.0 85.0 °C R/W * * *  
A72 Voltage pangayoman ngaktifake 0/Ora 1 / Ya 0/Ora   R/W * * *  
A73 Minimal cut-in voltage 0 270 0 Volt R/W * * *  
A74 Minimal cut-out voltage 0 270 0 Volt R/W * * *  
A75 Maksimum cut-in voltage 0 270 270 Volt R/W * * *  
D- defrost
d01 Metode defrost

(0) ora = Ora ana, (1) nat = Natural, (2) El = Listrik,

(3) gas = gas panas

0 3 2   R/W * * *  
d02 Suhu mandeg defrost 0.0 50.0 6.0 °C R/W * * *  
d03 Interval antarane defrost diwiwiti 0 240 8 jam R/W * * *  
d04 Maks. durasi defrost 0 480 30 min R/W * * *  
d05 Wektu o disetel kanggo miwiti defrost pisanan nalika wiwitan 0 240 0 min R/W * * *  
d06 Tetes wektu 0 60 0 min R/W * * *  
d07 Tundha kanggo wiwitan penggemar sawise defrost 0 60 0 min R/W * * *  
d08 Suhu wiwitan kipas -40.0 50.0 -5.0 °C R/W * * *  
d09 Operasi kipas nalika defrosting 0/O 1 / Ing 1 / Ing   R/W * * *  
d101) Sensor defrost (0=waktu, 1=Sair, 2=S5) 0 2 0   R/W * * *  
d18 Maks. komp. runtime antarane rong defrosts 0 96 0 jam R/W * * *  
d19 Defrost on demand - variasi suhu S5 sing diidinake sajrone frost build-up.

Ing tanduran tengah pilih 20 K (=o)

0.0 20.0 20.0 K R/W * * *  
d30 Tundha defrost sawise ditarik mudhun (0 = OFF) 0 960 0 min R/W * * *  
F- Penggemar
F01 Kipas angin ing ndhuwur kompresor

(0) FFC = Tindakake komp., (1) Fao = ON, (2) FPL = Kipas angin

0 2 1   R/W * * *  
F04 Suhu mandeg kipas (S5) -40.0 50.0 50.0 °C R/W * * *  
F07 Fan pulsing ON siklus 0 180 2 min R/W * * *  
F08 Siklus OFF pulsing kipas 0 180 2 min R/W * * *  
c– Kompresor
c01 Min. ON-wektu 0 30 1 min R/W * * *  
c02 Min. OFF-wektu 0 30 2 min R/W * * *  
c04 Kompresor OFF tundha nalika lawang mbukak 0 900 0 sek R/W * * *  
c70 Zero crossing pilihan 0/Ora 1 / Ya 1 / Ya   R/W * * *  
o– macem-macem
o01 Tundha output nalika wiwitan 0 600 10 sek R/W * * * *
o021) DI1 konfigurasi

(0) OFF= ora digunakake, (1) Sdc= status, (2) dhuh= fungsi lawang, (3)

doA= weker lawang, (4) SCH= saklar utama,

(5) nig= mode awan/wengi, (6) rFd= pamindahan referensi, (7)

EAL= weker eksternal, (8) dEF= defrost,

(9) Pud= narik mudhun, (10) Sc= sensor kondensor

0 10 0   R/W * * * *
o031) Alamat jaringan 0 247 0   R/W * * * *
o05 Kode akses 0 999 0   R/W * * * *
o061) Pilihan jinis sensor

(0) n5 = NTC 5k, (1) n10 = NTC 10k, (2) Pt = Pt1000, (3) Ptc = PTC 1000

0 3 2   R/W * * * *
o15 Résolusi tampilan

(0) 0.1, (1) 0.5, (2) 1.0

0 2 0   R/W * * * *
o16 Maks. wektu siyaga sawise defrost terkoordinasi 0 360 20 min R/W * * *  
Kode Manual teks singkat  

Min.

 

Maks.

 

Def.

 

Unit

 

R/W

EKC 224 Appl.
1 2 3 4
o371) konfigurasi DI2

(0) OFF= ora digunakake, (1) Sdc= status, (2) dhuh= fungsi lawang, (3)

doA= weker lawang, (4) SCH= saklar utama,

(5) nig= mode awan/wengi, (6) rFd= pamindahan referensi, (7)

EAL= weker eksternal, (8) dEF= defrost,

(9) Pud= narik mudhun

0 9 0   R/W * * * *
o38 Konfigurasi fungsi cahya

(0) on= tansah, (1) dAn= awan/wengi,

(2) dhuh= adhedhasar tumindak lawang, (3) nEt = Jaringan

0 3 1   R/W *   * *
o39 Kontrol cahya liwat jaringan (mung yen o38=3 (nEt)) 0/O 1 / Ing 1 / Ing   R/W *   * *
o611) Pilihan saka mode aplikasi

(1) AP1: Cmp/Def/Fan/Lampu

(2) AP2: Cmp/Def/Fan/Weker

(3) AP3: Cmp/Al/Kipas angin/Lampu

(4) AP4: Panas / Weker / Cahya

1 4 1   R/W * * * *
o621) Prasetel cepet paramèter utama 0 = Ora digunakake

1 = MT, Defrost alami, mandheg ing wektu 2 = MT, El defrost, mandheg ing wektu

3 = MT, El defrost, mandheg ing suhu. 4 = LT, El defrost, mandheg ing suhu

5 = Kamar, MT, El defrost, mandheg ing wektu 6 = Kamar, MT, El defrost, mandheg ing suhu.

7 = Kamar, LT, El defrost, mandheg ing suhu.

0 7 0   R/W * * *  
o67 Ganti setelan pabrik controller karo setelan saiki 0/Ora 1 / Ya 0/Ora   R/W * * * *
o91 Tampilan ing defrost

(0) hawa= Suhu sair / (1) FrE= suhu beku / (2)

-d-= "-d-" ditampilake

0 2 2   R/W * * *  
P– Polaritas                  
P75 Walik relay weker

(1) = Invert relay action

0 1 0   R/W   * * *
P76 Kunci keyboard ngaktifake 0/Ora 1 / Ya 0/Ora   R/W * * * *
u– Layanan
u00 Negara kontrol

S0: Normal, S1: Ngenteni sawise defrost, S2: Timer ON min,

S3: Timer OFF Min, S4: Tetes o , S10: r12 Saklar utama disetel OFF,

S11: Thermostat Cut-out, S14: Defrosting, S15: Fan tundha,

S17: Lawang mbukak, S20: Pendinginan darurat, S25: Kontrol manual,

S30: Siklus Pulldown, S32: Tundha daya, S33: Pemanasan

0 33 0   R * * * *
u01 Suhu udara Sair -100.0 200.0 0.0 °C R * * * *
u09 S5 suhu Evaporator -100.0 200.0 0.0 °C R * * * *
u10 Status input DI1 0/O 1 / Ing 0/O   R * * * *
u13 Kondisi wengi 0/O 1 / Ing 0/O   R * * * *
u37 Status input DI2 0/O 1 / Ing 0/O   R * * * *
u28 Referensi termostat nyata -100.0 200.0 0.0   R * * * *
u58 Kompresor / Katup solenoid garis Cairan 0/O 1 / Ing 0/O   R * * *  
u59 Relay kipas 0/O 1 / Ing 0/O   R * * *  
u60 Relay defrost 0/O 1 / Ing 0/O   R * *    
u62 Relay weker 0/O 1 / Ing 0/O   R   * * *
u63 Relay cahya 0/O 1 / Ing 0/O   R *   * *
u80 Pembacaan versi firmware         R * * * *
u82 Kode pengontrol no.         R * * * *
u84 relay panas 0/O 1 / Ing 0/O   R       *
U09 Suhu Kondensor Sc -100.0 200.0 0.0   R * * *  

Kode weker

Ing kahanan weker, tampilan bakal sulih antarane maca suhu udhara nyata lan maca kode weker weker aktif.

Kode Weker Katrangan Weker jaringan
E29 Sair sensor kesalahan Sensor suhu udhara rusak utawa sambungan listrik ilang - Kesalahan Sair
E27 Def sensor kesalahan S5 Evaporator sensor risak utawa sambungan listrik ilang - Kesalahan S5
E30 kesalahan sensor sc Sensor kondensor Sc minangka cacat utawa sambungan listrik ilang - Kesalahan Sc
A01 Alarm suhu dhuwur Suhu udhara ing lemari dhuwur banget - Dhuwur t.weker
A02 Weker suhu rendah Suhu udhara ing kabinèt sithik banget - Kurang t. Weker
A99 Alarm High Volt Sumber voltage dhuwur banget (proteksi kompresor) - Dhuwur Voltage
AA1 Weker Low Volt Sumber voltage kurang banget (proteksi kompresor) - Low Voltage
A61 Alarm kondensor Suhu kondensor dhuwur banget - mriksa aliran udara - Weker Cond
A80 Cond. weker pamblokiran Suhu kondensor dhuwur banget - Reset manual weker dibutuhake) - Cond Diblokir
A04 Weker lawang Lawange wis suwe banget - Weker lawang
A15 Weker DI Weker eksternal saka input DI - Weker DI
A45 Weker siyaga Kontrol wis mandheg dening "r12 Main switch" - Mode siyaga
  • Weker pamblokiran kondensor bisa direset kanthi nyetel saklar utama r12 OFF lan ON maneh utawa kanthi mateni pengontrol.

Danfoss A / S

  • Solusi Iklim
  • danfoss.com
  • +457488 2222
  • Informasi apa wae, kalebu, nanging ora winates ing informasi babagan pilihan produk, aplikasi utawa panggunaan, desain produk, bobot, dimensi, kapasitas, utawa data teknis liyane ing katrangan katalog manual produk, iklan, lsp, lan apa digawe kasedhiya ing nulis, cublak, elektronik, online utawa liwat download, bakal dianggep informatif lan mung naleni yen lan cadangan Danfos rige iso atterits produk tanpa enotice.
  • Iki uga cocog kanggo produk sing diprentah nanging ora mati / diverifikasi supaya owah-owahan kasebut bisa ditindakake tanpa owah-owahan ing wangun, pas, utawa fungsi produk kasebut.
  • Kabeh merek dagang ing materi iki minangka properti saka Danfoss A/S utawa perusahaan grup Danfoss. Danfoss lan logo Danfoss minangka merek dagang Danfoss A/S. Kabeh hak dilindhungi undhang-undhang.
  • AN432635050585en-000201
  • © Danfoss Climate Solutions 2023.05

Dokumen / Sumber Daya

Danfoss 80G8429 Case Controller Tipe EKC 224 [pdf] Pandhuan Instalasi
80G8429, 80G8446, 80G8390, 80G8392, 80G8391, 80G8432, 80G8433, 80G8434, 84B8346, 80G8435, 80G8440, 80, 8429G224 80G8429, Tipe Pengontrol Case EKC 224, Tipe Pengontrol EKC 224, Tipe EKC 224, EKC 224

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *