Altronix Maximal3F Maximal F Series Single Power Supply Akses Pengontrol Daya
Model Kalebu
Maksimal3F
- 12VDC @ 4.6A utawa 24VDC @ 5.2A.
- Nembelas (16) sekring dilindhungi output non daya winates.
Maksimal5F
- 12VDC @ 8.6A.
- Nembelas (16) sekring dilindhungi output non daya winates.
Maksimal7F
- 24VDC @ 9.2A.
- Nembelas (16) sekring dilindhungi output non daya winates.
Seri MaximalF Swaraview
Pengontrol Daya Akses MaximalF nyebarake lan ngalih daya kanggo ngakses sistem kontrol lan aksesoris. Padha ngowahi input 120VAC 60Hz dadi nembelas (16) kontrol independen 12VDC utawa 24VDC output dilindhungi sekring. Output daya Gagal-Aman/Gagal-Aman iki bisa diowahi dadi kontak "C" sing garing. Output diaktifake dening sink kolektor mbukak utawa input pemicu garing biasane mbukak (NO) saka Sistem Kontrol Akses, Keypad, Tombol Push, REX PIR, lan sapiturute. Unit bakal ngarahake daya menyang macem-macem piranti hardware kontrol akses kalebu: Kunci Mag , Serangan Listrik, Pemegang Door Magnetik, lsp. Antarmuka FACP mbisakake Egress Darurat, Pemantauan Alarm, utawa bisa digunakake kanggo micu piranti tambahan liyane. Fitur pedhot weker geni bisa dipilih kanthi individu kanggo siji utawa kabeh saka nembelas (16) output. Kabeh peralatan interconnecting kudu UL Listed.
Papan Catu Daya Arus Input 120VAC 60Hz Papan Catu Daya Input Rating Papan Catu Daya Papan Catu Daya Baterei Rating Sekering 12VDC Range Output (V) Range Output 24VDC (V) Range Output 12VDC (V) Range Output 24VDC (V) Fuse Protected Output Non Daya Wates Saiki Per ACM8 Output (A) ACM8 Board Input Fuse Rating ACM8 Board Output Fuse Rating
Bagan Konfigurasi Seri MaximalF:
Nomer Model Altronix | 120VAC 60Hz Input Saiki |
Power Supply Papan Input Fuse Rating | Papan Pasokan Daya Baterai Fuse Rating | Nominal DC Output Voltage | Maksimum Supply Saiki kanggo Utama lan Aux. Output ing papan Catu Daya lan output Pengontrol Daya Akses ACM8 (A) | Fuse Protected Non Power-Limited Output | Saiki Per ACM8 Output (A) | ACM8 Papan Input Fuse Rating | ACM8 Papan Output Fuse Rating | |||
[DC] | [Aux] | |||||||||||
Range Output 12VDC (V) | Range Output 24VDC (V) | Range Output 12VDC (V) | Range Output 24VDC (V) | |||||||||
Maksimal3F | 3.5A | 5A/
250V |
10A/
32V |
10.0-
13.2 |
20.19-
26.4 |
10.03-
13.2 |
20.19-
26.4 |
12VDC @ 4.6A utawa
24VDC @ 5.2A |
16 | 2.5 | 10A/
250V |
3.5A/
250V |
Maksimal5F | 3.5A | 5A/
250V |
15A/ 32V |
10.03-13.2 | – | 10.03-
13.2 |
– | 8.6A | 16 | 2.5 | 10A/
250V |
3.5A/
250V |
Maksimal7F | 4.5A | 6.3A/
250V |
15A/
32V |
– | 20.17-
26.4 |
– | 20.28-
26.4 |
9.2A | 16 | 2.5 | 10A/
250V |
3.5A/
250V |
Output DC kanggo sumber daya iki ora winates daya. Yen output daya-winates dibutuhake ing aplikasi produk pungkasan, output DC saka sumber daya kudu disambungake menyang unit kontrol kapisah Listed utawa Papan aksesoris sing nyedhiyani output daya-winates. Produk(e) sing nyedhiyakake output (e) winates daya kudu kadhaptar sing cocog kanggo aplikasi produk pungkasan tartamtu (kontrol akses), lan nganggo kabel sesuai karo instruksi instalasi produk. Cara kabel kelas 1, pamisahan sirkuit, lan enclosure sing dirating geni sing tepat kabeh kudu dianggep nalika nyambungake output DC saka sumber daya menyang piranti produk pungkasan. Output tambahan saka unit kasebut diwatesi daya.
Daftar Agensi:
Listings UL kanggo
Instalasi AS: UL 294* - UL Dhaptar kanggo Unit Sistem Kontrol Akses.
*ANSI/UL 294 7th Ed. Tingkat Kinerja Kontrol Akses:
Serangan ngrusak - I; Ketahanan - I; Keamanan Line - I; Daya Stand-by - II, III, IV.
Listings UL kanggo
Instalasi Kanada:
ULC-S319-05 - Peralatan Sistem Kontrol Akses Elektronik Kelas I. CSA C22.2 No.205 - Peralatan Sinyal.
Sistem Kontrol Akses Elektronik ULC-S319-05 bakal ora valid amarga nggunakake tambahan, ekspansi, memori utawa modul liyane sing diprodhuksi dening pabrikan utawa pabrikan liyane.
Fitur Seri MaximalF:
Modul Kontrol Daya Akses ACM8:
- Nembelas (16) kanthi mandiri micu output sing dikontrol. Pilihan Output:
a) Nembelas (16) output daya saring Gagal-Aman.
b) Nembelas (16) output daya saring Gagal-Aman.
c) Nembelas (16) mbentuk output relay "C" (dirating @ 5A/28VDC utawa VAC).
d) Sembarang kombinasi saka ndhuwur. - Nembelas (16) input pemicu Sistem Kontrol Akses. Pilihan pemicu input:
a) Nembelas (16) input pemicu garing biasane mbukak (NO).
b) Nembelas (16) input kolektor mbukak. c) Sembarang kombinasi saka ndhuwur. - Nembelas (16) aux disaring sing ora diowahi. output daya (output dirating @ 2.5A).
- LED abang ing Papan ACM8 nuduhake output individu sing micu (relay energized).
- Pedhot Alarm Kebakaran (latching utawa non-latching) bisa dipilih kanthi individu kanggo kabeh utawa wolung (8) output.
Pilihan pemicu input Alarm Kebakaran:
a) Input pemicu garing biasane mbukak (NO) utawa biasane ditutup (NC).
b) Input pembalikan polaritas saka sirkuit sinyal FACP. - LED ijo ing papan ACM8 nuduhake pedhot FACP dipicu.
- Relay output FACP nuduhake yen input FACP dipicu (bentuk kontak "C" dirating @ 1A / 28VDC ora dievaluasi dening UL).
- eFlow Power Supply / Charger menehi daya umum kanggo Papan ACM8 (wiring pabrik) lan kabeh piranti kontrol akses disambungake (wiring lapangan).
- Sekring utama papan ACM8 dirating @ 10A. Sekring output dirating @ 3.5A.
Sumber Daya / Pengisi Daya eFlow:
- Input: 120VAC, 60Hz. · Kanggo output voltage lan sumber saiki deleng Bagan Konfigurasi seri MaximalF, pg. 3.
- Auxiliary Power-Limited output rating @ 1A (unswitched).
- Overvoltage pangayoman.
- Pangisi daya internal kanggo batere asam timbal utawa gel sing ditutup.
- Pangisian daya maksimum saiki 1.54A.
- Ngalih otomatis menyang baterei stand-by nalika AC gagal. Transfer menyang daya baterei siyaga langsung tanpa gangguan.
- Diawasi Fire Alarm pedhot (latching utawa non-latching) 10K EOL resistor. Makaryakke ing pemicu biasane mbukak (NO) utawa biasane ditutup (NC).
- Pengawasan gagal AC (bentuk kontak "C").
- Baterei gagal & pengawasan ngarsane (wangun "C" kontak).
- mateni daya kurang. Mateni terminal output DC yen baterei voltage mudhun ing ngisor 71-73% kanggo unit 12V lan 70-75% kanggo unit 24V (gumantung saka sumber daya). Ngalangi discharge baterei jero.
- Kanggo rating sekring deleng Bagan Konfigurasi seri MaximalF, pg. 3.
- LED Daya AC Hijau nuduhake 120VAC saiki.
- Indikator LED input AC lan output DC.
- Short circuit lan pangayoman kakehan.
- Enclosure nampung nganti papat (4) baterei 12VDC / 12AH. Ukuran kandang (H x W x D): 26″ x 19″ x 6.25″ (660.4mm x 482.6mm x 158.8mm).
Instruksi Instalasi MaximalF:
Cara pengkabelan kudu sesuai karo Kode Listrik Nasional / NFPA 70 / ANSI, Kode Listrik Kanada, Part I, Part II lan kabeh kode lan panguwasa lokal sing duwe yurisdiksi. Produk dimaksudake mung kanggo panggunaan njero ruangan.
- Pasang unit ing lokasi sing dikarepake. Tandhani lan predrill bolongan ing tembok kanggo baris munggah karo telung keyholes ndhuwur ing pager. Pasang telung fasteners ndhuwur lan ngawut-awut ing tembok karo kepala meneng protruding. Selehake keyholes ndhuwur pager liwat telung ngawut-awut ndhuwur, tingkat lan aman. Tandhani posisi telung bolongan ngisor. Copot pager. Pengeboran bolongan ngisor lan pasang telung fasteners. Selehake bolongan tombol ndhuwur pager liwat telung sekrup ndhuwur. Pasang telung ngawut-awut ngisor lan priksa manawa kanggo ngencengi kabeh ngawut-awut (Dimensi Enclosure, pg. 15).
- Sambungake daya AC unswitched (120VAC 60Hz) kanggo terminal ditandhani [L, N] (Fig. 3, pg. 10). LED "AC" ijo ing papan sumber daya bakal diuripake. Cahya iki bisa dideleng liwat lensa LED ing lawang pager. Gunakake 14 AWG utawa luwih gedhe kanggo kabeh sambungan daya. Kabel ijo sing aman timbal menyang lemah. Supaya kabel daya winates kapisah saka non daya winates wiring. Jarak minimal 0.25″ kudu diwenehake (Gbr. 3, pg. 10).
AWAS: Aja ndemek bagean logam sing katon. Mateni daya sirkuit cabang sadurunge nginstal utawa nglayani peralatan. Ora ana bagean sing bisa digunakake pangguna ing njero. Rujuk instalasi lan servis menyang personel layanan sing mumpuni. - Pilih output DC sing dikarepake voltage kanthi nyetel SW1 menyang posisi cocok ing sumber daya Maximal3F (Fig. 1a, pg. 9).
Sumber daya Maximal5F disetel pabrik ing 12VDC lan sumber daya Maximal7F disetel ing pabrik ing 24VDC. - Ukur output voltage saka unit sadurunge nyambungake piranti kanggo mesthekake operasi sing bener. Vol ora cocog utawa dhuwurtage bakal ngrusak piranti kasebut.
- Pilihan output (Gambar 2, kaca 9):
Unit kasebut bakal nyedhiyakake enem belas (16) output daya sing diuripake, nembelas (16) output "C" sing garing, utawa kombinasi apa wae saka output daya sing diuripake lan output "C".
(a) Output Daya Ngalih sing Gagal Aman:
Kanggo operasi Gagal-Aman, sambungake input positif (+) saka piranti kontrol akses menyang terminal sing ditandhani [NC]. Sambungake input negatif () saka piranti kontrol akses menyang terminal ditandhani [COM].
(b) Output Daya Saklar Aman-Gagal:
Kanggo operasi Fail-Secure sambungake input positif (+) saka piranti kontrol akses menyang terminal sing ditandhani [NO]. Sambungake input negatif () saka piranti kontrol akses menyang terminal ditandhani [COM].
(c) Output Formulir "C":
Nalika output "C" dikarepake, sekring output sing cocog (1-8) saben papan ACM8 kudu dicopot. - Output Daya Tambahan ACM8 (ora ngalih):
Sambungake piranti kontrol akses sing mbutuhake daya konstan menyang terminal sing ditandhani [C] positif (+) lan [COM] negatif (). Output bisa digunakake kanggo nyedhiyani daya kanggo maca kertu, keypads etc.
Output tambahan eFlow (ora ngalih):
Kanggo sambungan piranti tambahan, output iki ora bakal kena pengaruh Low Power Disconnect utawa Fire Alarm Interface. Sambungake piranti menyang terminal sing ditandhani [+ AUX] (Fig. 3, pg. 10). - Pilihan pemicu input (Gbr. 2, pg. 9):
(a) Biasane mbukak pemicu input [NO]:
Input 1-8 diaktifake kanthi input sink kolektor sing biasane mbukak utawa mbukak. Sambungake output panel kontrol akses, keypad, tombol push, REX PIRs, lan sapiturute menyang terminal ditandhani [IN] lan [GND].
(b) Input Sink Kolektor Terbuka:
Sambungake panel kontrol akses mbukak kolektor sink positif (+) kanggo terminal ditandhani [IN] lan negatif () kanggo terminal ditandhani [GND]. - Pilihan Antarmuka Alarm Kebakaran ACM8 (Gambar 5-9, kaca 12):
Pemicu input [NC] utawa biasane mbukak [NO] saka panel kontrol weker geni utawa input pembalikan polaritas saka sirkuit sinyal FACP bakal mengaruhi output sing dipilih. Kanggo ngaktifake FACP Disconnect kanggo output, mateni saklar sing cocog [SW1-SW8] ing saben papan ACM8. Kanggo mateni FACP pedhot kanggo output, nguripake saklar sing cocog (e) [SW1-SW8] ing saben Papan ACM8.
(a) Biasane mbukak input [NO]:
Kanggo non-latching hook-up deleng (Fig. 6, pg. 12). Kanggo latching hook-up deleng Fig. 7, pg. 12.
(b) Input [NC] Biasane Ditutup:
Kanggo non-latching hook-up deleng (Fig. 8, pg. 12). Kanggo latching hook-up deleng Fig. 9, pg. 12.
(c) Pemicu input Sirkuit Sinyal FACP:
Sambungake positif (+) lan negatif () saka output sirkuit sinyal FACP menyang terminal sing ditandhani [+ INP]. Sambungake FACP EOL menyang terminal sing ditandhani [+ RET -] (polaritas dirujuk ing kondisi weker). Jumper dumunung ing jejere TRG LED kudu Cut (Fig. 5, pg. 12). - FACP Formulir Kering "C" output (Fig. 2a, pg. 12) (Ora dievaluasi dening UL):
Kontak formulir "C" FACP bisa digunakake kanggo micu piranti pelapor utawa sinyal. Kontak kasebut ngalih marang pemicu input weker geni menyang papan ACM8. - Sambungan Baterei Stand-by (Gambar 3, kaca 9):
Kanggo aplikasi Kontrol Akses AS, baterei opsional. Baterei dibutuhake kanggo instalasi Kanada (ULC-S319). Nalika baterei ora digunakake, mundhut saka AC bakal kasil mundhut saka output voltage. Nalika nggunakake baterei stand-by dikarepake, padha kudu asam timbal utawa jinis gel. Sambungake baterei menyang terminal sing ditandhani [ BAT + ] (Fig. 3, pg. 10). Gunakake rong (2) baterei 12VDC disambungake ing seri kanggo operasi 24VDC (baterei ndadékaké klebu). Gunakake baterei - baterei Casil CL1270 (12V / 7AH), CL12120 (12V / 12AH), CL12400 (12V / 40AH), CL12650 (12V / 65AH) utawa baterei BAZR2 lan BAZR8 sing diakoni UL kanthi rating sing cocog. - Baterei lan output Pengawasan AC (Gambar 3, kaca 10):
Sampeyan kudu nyambungake piranti laporan masalah pengawasan menyang output sing ditandhani [AC Fail, BAT Fail] output relay pengawas sing ditandhani [NC, C, NO] menyang piranti notifikasi visual sing cocog. Gunakake 22 AWG nganti 18 AWG kanggo laporan AC Gagal & Kurang/Ora Ana Baterei. - Kanggo tundha laporan AC sajrone 2 jam, setel switch DIP [Tundha AC] menyang posisi OFF (Gambar 3, pg. 10). Kanggo tundha laporan AC sajrone 1 menit, setel saklar DIP [Tundha AC] menyang posisi ON (Gbr. 3, pg. 10).\
- Pedhot Alarm Kebakaran (Gambar 3, kaca 10):
Kanggo ngaktifake Fire Alarm Disconnect, atur switch DIP [Shutdown] menyang posisi ON. Kanggo mateni Alarm Kebakaran Pedhot setel saklar DIP [Shutdown] menyang posisi OFF - Pemasangan Tamper Ngalih (Gambar 3b, kaca 10):
Gunung UL Listed tampngalih er (model Altronix TS112 utawa padha) ing ndhuwur pager. Geser tamper ngalih krenjang menyang pinggir pager kira-kira 2″ saka sisih tengen (Fig. 3b, pg. 10). Nyambung tampngalih kabel menyang input Panel Kontrol Akses utawa piranti laporan UL Listed sing cocog. Kanggo ngaktifake sinyal weker, bukak lawang pager.
Pangopènan:
Unit kudu dites paling ora sepisan taun kanggo operasi sing tepat kaya ing ngisor iki:
Pengawasan FACP: | Kanggo mesthekake sambungan sing tepat lan operasi saka Alarm geni medhot hookup, tindakake prosedur sing cocog ing ngisor iki: |
Biasane mbukak Input: | Nempatake cendhak ing antarane terminal sing ditandhani [T] lan [+ INP] bakal micu Pedhot Alarm Kebakaran. Copot singkat kanggo ngreset. |
Input Biasane Ditutup: | Mbusak kabel saka terminal sing ditandhani [INP –] bakal micu Pedhot Alarm Kebakaran. Ganti kabel menyang terminal sing ditandhani [INP –] kanggo ngreset. |
Input Sirkuit FACP: | t perlu kanggo micu Fire Alarm System. Ing kabeh skenario ndhuwur bakal TRG LED ijo saka ACM8s madhangi. Kabeh output sing dipilih kanggo Fire Alarm Disconnect bakal ngaktifake ngeculake piranti ngunci |
Cathetan: Kabeh output [OUT 1] – [OUT 8] kudu ing kondisi normal (de-energized) sadurunge testing. Nalika unit diatur kanggo Biasane Bukak (Fig. 7, pg. 12) utawa Biasane Ditutup (Fig. 9, pg. 12) operasi latching iku perlu kanggo ngreset Fire Alarm Disconnect kanthi ngaktifake ngalih reset Biasane Ditutup.
Output Voltage Tes: | Ing kondisi mbukak normal, DC output voltage kudu dipriksa kanggo vol sing tepattage tingkat (waca MaximalF seri Bagan Konfigurasi, pg. 3). |
Test baterei: | Ing kahanan mbukak normal mriksa yen baterei wis kebak, mriksa kasebut voltage ing terminal baterei lan ing terminal Papan ditandhani [+ BAT –] kanggo mesthekake yen ana break ing kabel sambungan baterei. |
Cathetan: Saiki pangisian daya maksimal yaiku 1.54A. Umur baterei sing dikarepake yaiku 5 taun; Nanging, dianjurake kanggo ngganti baterei ing 4 taun utawa kurang yen perlu.
Diagnostik LED Papan Pasokan Daya:
Abang (DC) | Ijo (AC/AC1) | Status Pasokan Daya |
ON | ON | Kondisi operasi normal. |
ON | OFF | Mundhut AC. Baterei stand-by nyedhiyakake daya. |
OFF | ON | Ora ana output DC. |
OFF | OFF | Mundhut AC. Baterei kosong utawa ora ana stand-by. Ora ana output DC. |
Abang (Kelawar) | Status baterei |
ON | Kondisi operasi normal. |
OFF | Baterei gagal / baterei sithik. |
Diagnostik LED Kontrol Daya Akses:
LED | ON | OFF |
LED 1- LED 8 (Abang) | Output relay (s) energized. | Output relay (s) de-energized. |
Trg (Ijo) | Input FACP dipicu (kondisi weker). | FACP normal (kondisi non-alarm). |
Spesifikasi Baterai Stand-by Papan Catu Daya:
Baterei | Maksimal3F | Maksimal5F | Maksimal7F |
7AH | 10 Menit/6A | 5 Menit/10A | 5 Menit/10A |
12AH | 30 Menit/6A* | 30 Menit/10A* | 30 Menit/10A* |
40AH | Luwih saka 4 Jam/6A* | Luwih saka 2 Jam/10A* | Luwih saka 2 Jam/10A* |
65AH | Luwih saka 4 Jam/6A* | Luwih saka 4 Jam/10A* | Luwih saka 4 Jam/10A* |
Identifikasi Terminal Papan Sumber Daya:
Katrangan Terminal | Fungsi/Deskripsi |
L, G, N | Sambungake 120VAC 60Hz menyang terminal iki: L kanggo panas, N kanggo netral. Aja nggunakake terminal sing ditandhani [G]. |
+ DC - | Pabrik disambungake menyang papan ACM8. |
Pemicu EOL Diawasi | Fire Alarm Interface micu input saka singkat utawa FACP. Input pemicu bisa biasane mbukak, biasane ditutup saka sirkuit output FACP (input winates daya kelas 2)(Gambar 3, kaca 10). |
Ora, GND RESET | Antarmuka FACP latching utawa non-latching (Kelas 2 winates daya) (Gambar 3, kaca 10). |
+ AUX- | Output winates daya Kelas Tambahan 2 dirating @ 1A (ora ngalih) (Gambar 3, kaca 10). |
AC GAGAL NC, C, NO | Nuduhake mundhut daya AC, contone, nyambung menyang piranti sing bisa dirungokake utawa panel weker. Relay biasane diuripake nalika daya AC ana. Rating kontak 1A @ 30VDC (Kelas 2 winates daya) (Gambar 3, kaca 10). |
BAT GAGAL NC, C, NO | Nuduhake kahanan baterei sithik, contone, nyambung menyang panel weker. Relay biasane diuripake nalika daya DC ana. Rating kontak 1A @ 30VDC. Baterei sing dicopot dilaporake sajrone 5 menit. Sambungan maneh baterei dilaporake sajrone 1 menit (Watesan daya kelas 2) (Gambar 3, kaca 10). |
+ BAT— | Sambungan baterei stand-by. Pangisian daya maksimal saiki 1.54A (ora winates daya) (Gambar 3, kaca 10). |
Identifikasi Terminal Kontrol Daya Akses:
Katrangan Terminal | Fungsi/Deskripsi |
- Daya + | 12VDC utawa 24VDC saka sumber daya / pangisi daya (pabrik disambungake). Terminal kasebut sejajar karo terminal [– Control +]. |
- Kontrol + |
Terminal iki sejajar karo terminal [– Power +]. Terminal-terminal kasebut bisa disambungake menyang sumber daya kontrol akses winates daya sing didhaptar eksternal kanggo nyedhiyakake daya operasi sing terisolasi kanggo piranti kasebut (Ora dievaluasi dening UL). Jumper J1 lan J2 kudu dibusak. |
PEMICU INPUT1 – INPUT 8 IN, GND | Saka input pemicu sink kolektor sing biasane mbukak lan / utawa mbukak (panyuwunan kanggo metu tombol, metu PIR, lsp.) |
OUTPUT 1- OUTPUT 8 NC, C, NO, COM | Output kontrol pemicu 12VDC nganti 24VDC dirating ing 2.5A. Maksimal3F: 10.0-13.2VDC @ 4.6A utawa 20.19-26.4VDC @ 5.2A. Maksimal5F: 10.03-13.2VDC @ 8.6A. Maksimal7F: 20.17-26.4VDC @ 9.2A. Gagal-Aman [NC positif (+) & COM Negatif (-)], Gagal-Aman [NO positif (+) & COM Negatif (-)], Auxiliary output [C positif (+) & COM Negatif (-)]. Nalika nggunakake sumber daya AC polaritas ora perlu diamati. NC, C, NO dikonversi dadi wangun garing "C" 5A 24VAC/VDC dirating output garing nalika sekring dibusak. Kontak sing ditampilake ing negara sing ora dipicu. |
ANTARA FACP T, + INPUT – | Fire Alarm Interface micu input saka FACP. Input pemicu bisa biasane mbukak, biasane ditutup saka output sirkuit sinyal FACP (Gambar 5-9, kaca 12). |
ANTARA FACP NC, C, NO | Kontak relay Formulir "C" dirating @ 1A 28VDC kanggo laporan weker (ora dievaluasi dening UL). |
Power Supply Papan Output Voltage Setelan:
Diagram Aplikasi Khas Pengontrol Daya Akses (kanggo saben ACM8):
AWAS: Nalika papan sumber daya disetel kanggo 12VDC mung nggunakake siji (1) 12VDC stand-by baterei.
Tetep kabel winates daya kapisah saka non daya winates. Gunakake spasi minimal 0.25″.
Baterei sing bisa diisi ulang 12AH minangka baterei paling gedhe sing bisa dipasang ing kandang iki. Enclosure baterei eksternal sing kadhaptar UL kudu digunakake yen nggunakake baterei 40AH utawa 65AH.
NEC Power-Limited Wiring Requirements:
Wiring sirkuit winates daya lan non-daya kudu tetep dipisahake ing kabinet. Kabeh kabel sirkuit winates daya kudu tetep paling sethithik 0.25″ adoh saka kabel sirkuit sing ora winates. Salajengipun, kabeh kabel sirkuit winates daya lan kabel sirkuit non-daya kudu mlebu lan metu saka kabinet liwat saluran sing beda. Salah sijine mantanample iki kapacak ing ngisor iki. Aplikasi khusus sampeyan mbutuhake knockout saluran sing beda kanggo digunakake. Sembarang knockout saluran bisa digunakake. Kanggo aplikasi daya-winates nggunakake conduit iku opsional. Kabeh sambungan kabel lapangan kudu digawe nggunakake ukuran cocok CM utawa kabel jaket FPL (utawa sulih padha). Enclosure baterei UL Listed opsional kudu dipasang ing jejere sumber daya liwat metode kabel Kelas 1. Kanggo instalasi Canadian nggunakake wiring shielded kanggo kabeh sambungan.
Wigati: Waca gambar nangani kabel ing ngisor iki kanggo cara sing bener kanggo nginstal kabel jaket CM utawa FPL (Fig. 4a).
FACP Hook-Up Diagram:
Fig. 5 Input pembalikan polaritas saka output sirkuit sinyal FACP (polaritas dirujuk ing kondisi weker):
ukuran
Ukuran Enclosure (H x W x D kira-kira):
26" x 19" x 6.25" (660.4mm x 482.6mm x 158.8mm)
eFlow Power Supply / Charger bisa Controlled lan ngawasi nalika Reporting
Daya/Diagnostik saka ngendi wae liwat Jaringan…
LINQ2 – Modul Komunikasi Jaringan
LINQ2 nyedhiyakake akses IP remot menyang data wektu-nyata saka sumber daya / pangisi daya eFlow kanggo mbantu sistem tetep munggah lan mlaku ing tingkat optimal. Iku nggampangake instalasi lan nyetel-up cepet lan gampang, nyilikake downtime sistem, lan ngilangake telpon layanan rasah, kang mbantu ngurangi Total Biaya Kepemilikan (TCO) - uga nggawe sumber anyar saka Ambalan Monthly Revenue (RMR).
Fitur
- UL Kadhaptar ing AS lan Kanada.
- Kontrol lokal utawa remot nganti (2) loro output daya Altronix eFlow liwat LAN lan/utawa WAN.
- Monitor diagnostik wektu nyata: DC output voltage, output saiki, AC & baterei status / layanan, owah-owahan negara pemicu input, owah-owahan negara output lan suhu unit.
- Kontrol akses lan manajemen pangguna: Watesi maca / nulis, Watesi pangguna kanggo sumber daya tartamtu
- Loro (2) jaringan integral kontrol Formulir "C" Relay.
- Telung (3) pemicu input sing bisa diprogram: Kontrol relay lan sumber daya liwat sumber hardware eksternal.
- Email lan Windows Dashboard kabar
- Log acara nglacak riwayat.
- Secure Socket Layer (SSL).
- Programmable liwat USB utawa web browser
- kalebu piranti lunak operasi lan kabel USB 6 ft.
LINQ2 Mounts Nang sembarang MaximalF Enclosure
Dokumen / Sumber Daya
![]() |
Altronix Maximal3F Maximal F Series Single Power Supply Akses Pengontrol Daya [pdf] Pandhuan Instalasi Maximal3F, Maximal5F, Maximal7F, Maximal3F Maksimal F Series Pengontrol Daya Akses Pasokan Daya Tunggal, Maximal3F, Seri F Maksimum Akses Pasokan Daya Tunggal Pengontrol Daya Akses, Pengontrol Daya Akses, Pengontrol Daya, Pengontrol |