WS1 Wifi hitaskynjari
“
Vörulýsing
Fyrirmynd | Aflgjafi | Hámarksstraumur | Mælisvið | Nákvæmni | Upplausn | Verndarstig | Tengi | Lengd snúru | Samskiptabókun | RS485 heimilisfang | Baud hlutfall |
---|---|---|---|---|---|---|---|---|---|---|---|
UB-SEC-N1 | DC 4.5 ~ 30V | — | soil+60%+25) EC: 1S/cm Temperature: 0.1 Humidity: 0.1% | — | — | IP68 | Hljóð | 3m | RS485 Modbus RTU bókun | 0xD6 | 1200 bit/s, 2400 bit/s, 4800 bit/s (default), 9600 bit/s, 19200 biti/s |
Notkunarleiðbeiningar fyrir vöru
Mælisvæði
Measurement area: Inside a 5cm diameter cylinder of equal height
to the probes, centered on the center of the two probes.
Ground Penetration Method
Vertically dig a pit with a diameter of >20cm. Insert the
sensor pin horizontally into the pit wall at the established depth
and fill the pit tightly. After a period of stabilization,
measurements and recordings can be made over a period of days,
months, or even longer.
Samskiptareglur
1. Grunnatriði samskipta
- Kóðunarkerfisgagnabiti
- Parity Checking Bit Stop Bit Error Checking Baud Rate 1200
bit/s, 2400 bit/s, 4800 bit/s (default), 9600 bit/s, 19200
biti/s
2. Snið gagnaramma
Samskiptareglurnar Modbus-RTU eru notaðar í eftirfarandi
snið:
- Upphafleg uppbygging: 4 bæti í tíma.
- Address code: 1 byte, default 0xE1.
- Virknikóði: 1 bæti, stuðningsvirknikóði 0x03 (aðeins lesaðgangur)
og 0x06 (lesa/skrifa). - Gagnasvæði: N bæti, 16 bita gögn, hátt bæti kemur fyrst.
- Villuskoðun: 16-bita CRC kóða.
- Lokauppbygging: 4 bæti af tíma.
3. Skráð heimilisfang
Heimilisfang | Lýsing |
---|---|
0x0000 | Rakastig (ómerktar heiltölur, deilt með 10) |
0x0001 | Hitastig (heiltölur með formerki, deilt með 10) |
0x0002 | EC Address Baud Rate Register Address Register Length Function Code (Integer 1255) |
ATH:
- The probe must be fully inserted into the soil when
mæla. - Pay attention to lightning protection when using in the
sviði. - Do not violently bend the probe, do not pull the sensor lead
wire, do not drop or hit the sensor.
Algengar spurningar (algengar spurningar)
Q: How deep should the sensor be inserted into the soil for
nákvæmar mælingar?
A: The sensor should be fully inserted into the
soil for accurate measurements.
Sp.: Er hægt að nota skynjarann í umhverfi utandyra?
A: Yes, the sensor can be used in outdoor
environments. However, it is important to pay attention to
lightning protection when using it in the field.
Sp.: Hvaða samskiptareglur notar skynjarinn?
A: The sensor uses RS485 Modbus RTU Protocol
til samskipta.
“`
Vörukynning
The sensor, with its stable performance and high sensitivity, is an important tool for observing and studying the occurrence, evolution and improvement of saline soils and water-salt dynamics. Measurement of the dielectric constant of the soil provides a direct and stable reflection of the true water content of various soils, as well as a measurement of the volume percentage of soil moisture.
Use Case Scenarios The sensor is suitable for soil moisture monitoring, scientific experiments, water-saving irrigation, greenhouses, flowers and vegetables, meadows and pastures, rapid soil measurement, plant cultivation, wastewater treatment, fine agriculture and other occasions.
Features 1. Soil water content, conductivity and temperature in one. 2. Completely sealed, acid and alkali corrosion resistant, can be buried in the soil or directly into the
water for long-term dynamic detection. 3. High precision, fast response, good interchangeability, probe insertion design ensures accurate
measurement and reliable performance.
Vörulýsing
Gerð Aflgjafi Hámarksstraumsmælingarsvið
Nákvæmni
Resolution Protection level
Connector Cable Length Communication Protocol RS485 Address
Baud hlutfall
Tæknilýsing
UB-SEC-N1
DC 4.5 ~ 30V
110mA@5V EC: 0~20000S/cm Temperature: -40~80 Humidity: 0~100% EC: ±3%FS (0~10000S/cm), ±5%FS (10000~20000S/cm) Temperature: ±0.5 Humidity: ±2% (@0~50%, palm soil+30%+25) ; ±3% (@50~100%, palm
soil+60%+25) EC: 1S/cm
Temperature: 0.1 Humidity: 0.1% IP68
Hljóð
3m
RS485 Modbus RTU bókun
0xD6
1200 bitar/s, 2400 bitar/s, 4800 bitar/s (sjálfgefið), 9600 bitar/s, 19200 bitar/s
Leiðbeiningar um raflögn
Measurement Area Measurement area: Inside a 5cm diameter cylinder of equal height to the probes, centred on the centre of the two probes.
Quick Test Method Select a suitable measurement site, avoid rocks and ensure that the steel needle does not touch hard objects. Throw away the top layer of soil according to the required measuring depth, keep the original tightness of the soil underneath, and insert the sensor vertically into the soil by holding it tightly. Do not shake the sensor from side to side when inserting it. It is recommended to take several measurements within a small area of one measurement point to find the average value.
Ground Penetration Method Vertically dig a pit with a diameter of >20cm. Insert the sensor pin horizontally into the pit wall at the established depth and fill the pit tightly. After a period of stabilisation, measurements and recordings can be made over a period of days, months or even longer.
Samskiptareglur
1. Grunnbreytur samskipta
Kóðunarkerfisgagnabiti
Stöðvunarbiti fyrir jöfnuðarprófun
Villa við að athuga baudhraða
Grunnbreyta samskipta 8 bita tvíundarkóði 8 bitar enginn 1 biti CRC-prófun
1200 bitar/sek, 2400 bitar/sek, 4800 bitar/sek (sjálfgefið), 9600 bitar/sek, 19200 bitar/sek
2. Snið gagnaramma
Modbus-RTU samskiptareglur eru notaðar á eftirfarandi sniði:
Upphafsbygging 4 bæti í tíma.
Address code: 1 byte, default 0xE1.
Virknikóði: 1 bæti, stuðningsvirknikóði 0x03 (aðeins lesaðgangur) og 0x06 (lesa/skrifa).
Gagnasvæði: N bæti, 16 bita gögn, hátt bæti kemur fyrst.
Villuskoðun: 16-bita CRC kóða.
Lokauppbygging 4 bæti af tíma.
Beiðni
Heimilisfang þræla
Virknikóði Skráarfang Fjöldi skráa
CRC LSB
CRC MSB
1 bæti
1 bæti
2 bæti
2 bæti
1 bæti
1 bæti
Svar
Þrælavistfang Virknikóði Fjöldi bæti Efni 1 Efni 1
…
Efni n
CRC
1 bæti
1 bæti
1 bæti
2 bæti
2 bæti
…
2 bæti
2 bæti
3. Skráð heimilisfang
Address 0x0000 0x0001 0x0002 0x07D0 0x07D1
Content Humidity Temperature
EC Address Baud Rate
Skrá heimilisfang
Skráningarlengdarfallskóði
1
03
1
03
1
03
1
03/06
1
03/06
Lýsing á skilgreiningum Óformaðri heiltölu, deilt með 10
Signed integer data, divided by 10 Integer 1255
0:2400, 1:4800, 2:9600
NOTE 1. The probe must be fully inserted into the soil when measuring. 2. Pay attention to the lightning protection when using in the field. 3. Do not violently bend the probe, do not pull the sensor lead wire, do not drop or hit the sensor