Elitech-logo

Elitech Glog 5 Real Time Single Use IoT Data Logger

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-product

Product presentation

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-1

  1. Back mounted hanging hole
  2. LCD display screen
  3. LED indicator light
  4. Start stop button
  5. Serial number
  6. Light sensor
  7. Power supply+data interface
  8. Built-in sensors
  9. Activate/Flight Mode Button
  10. External sensor

LCD display

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-2

  1. Work status
  2. Function Description
  3. Flight mode
  4. Signal status
  5. Battery level
  6. Light and vibration alarm signs
  7. Time and number of records
  8. Temperature and humidity values

Note: To ensure data reliability, please do not enable recording when the battery level is less than or equal to 20% ( Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-3 between 10% and 20%)

Selection table

(standard light and vibration sensors)

 

Model Probe type Measuring range Accuracy
 

Glog 5 T

 

Built in temperature

 

-30℃~70℃

 

±0.5℃

 

Glog 5 TH

 

Built in temperature and humidity

-30℃~70℃ 0%RH~100%RH ±0.5℃

±5%RH

 

Glog 5 TE

External temperature+internal temperature  

-40℃~85℃

 

±0.5℃

 

Glog 5 THE

 

External temperature and humidity+internal temperature

External: -40℃~85℃ 0%RH~100%RH

built-in: -30℃~70℃

±0.5℃

±5%RH

 

Glog 5 TLE

External ultra-low temperature+internal temperature External: -200℃~150℃ built-in: -30℃~70℃ ±0.5℃(-40℃~85℃)

±1℃(-100℃~150℃)

± 2 ℃ (other)

Glog 5 CO₂ External ul-CO₂ & temperature

& humidity built-in temperature

-30℃~70℃ 0%RH~100%RH

0%~100vol%

±0.5℃

±5%RH

1vol%+3vol% measured

Technical parameter

Vibration range 0g~16g
Range of illumination intensity 0~52000Lux
Resolving power 0.1°C/0.1%RH/0.1g/1Lux
Key Double button design
Indicator light Red and green, red and blue LED indicator lights
Display Broken code display screen
Positioning method LBS+GPS (optional)
Storage capacity 60000 (pre shadow data) 32000 (normal recording+rear shadow data)
Shadow data Front+Rear
Record interval 1min~24h; Default: 5 minutes
Upload interval 1min~24h adjustable Default: 60 minutes
Data upload method 4G+2G
Freight initiation method Button, platform, timer
Freight stopping method Button, platform, full memory
Repeat startup 3 times (within the shelf life)
Flight Mode Button, timer, electronic fence
Alarm Mode Overlimit and low battery
Battery type 3.0V disposable lithium manganese battery 4800mAh (CR14505 3B6H)
OTA upgrade Upgrades can be made through data management software and platforms
Waterproof grade IP65 (built-in)
Work environment -30 ℃~70℃, 0% RH~100% RH (non condensing)
Storage environment 15~30℃,20~75%RH
Specification and size 103 x 61.3 x 30 (mm)
Battery life Record once every 5 minutes in a 25 ℃ environment, upload every 30 minutes, and use the temperature and humidity recorder for a total of 60 days;
Shelf life (Usage time+Storage time) 1 year

Technical parameter

Add device
Login platform website: http://www.i-elitech.com, or scan the code to download and install the APP . Register, log in, and add devices according to the prompts.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-4

Activation

Press and hold the Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5 button for 5s, and the screen will display normally, indicating that the device has been activated.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-6

Note: Clicking on the button and the screen displaying normally indicates that the device has been activated;

Start Record
Press and hold the Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-7 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-8 symbol, indicating successful startup recording; If theElitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-8indicator flashes, it will enter a delayed countdown state, and after the delay ends, it will automatically start recording;Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-9

Stop recording

Press and hold the Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-7 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-10 sign indicating that the recording has been successfully stopped;Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-11

Data export

The device is connected to the computer USB interface through a data cable and will automatically generate PDF+CSV format data reports. You can copy the generated report to your computer for saving.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-12

Note: The keys are invalid during the data export process

Flight Mode

  • Enable: Press and hold the Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-13symbol indicating that the airplane mode has been successfully activated;
  • Close: Press and hold the Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5button for 5s. If the screen Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-13icon disappears, it indicates that the airplane mode has been turned off;

Note: To enable and disable other flight modes, please operate through the platform or app.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-14

Freight Management Operation Instructions

  1. After logging into the platform or app, click on the ‘Freight Management’ menu in the main menu;
  2. Click on the ‘Configuration’ menu on the homepage, and sequentially create and add ‘User Management’, ‘Carrier’, ‘Location’, ‘Alarm Presets’, and’ Freight Template ‘;
  3. Click on the ‘Freight Management’ menu on the homepage to create and manage freight;

Note: For detailed operation manuals, please refer to the operating instructions on the platform or APP;

LED indicator light description

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-15

LCD display instructions

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-16

Safety instructions and precautions

Safety instructions

  • To ensure that you install and use this product correctly, please read and strictly comply with the following terms:

Battery

  • Please use the original battery and do not use other batteries to prevent damage to the equipment or other malfunctions. Do not disassemble, squeeze, hit, or heat the battery privately, and do not place it in a fire, otherwise it may cause battery explosion and fire.

Equipment

  • Do not use this equipment in flammable and explosive gas environments, otherwise it may cause explosions or fires. During the use of the equipment, if the equipment emits a burnt or other odor, the power supply should be immediately cut off and the manufacturer or supplier should be contacted in a timely manner.

Precautions and maintenance requirements

  • If the equipment is not used for a long time, it should be removed and stored in a dry and cool environment in the packaging box.
  • Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may affect the accuracy of the device or even damage it.
  • Do not place the device outdoors for use to avoid instrument short circuits, burns, and other malfunctions caused by adverse weather conditions such as rain and lightning.
  • When the recorder is offline (no data upload), please confirm the networking status of the device;
  • Please use within the measurement range of the recorder
  • Please do not forcefully impact this recorder
  • Sensors should be calibrated regularly to ensure their accuracy meets usage requirements
  • The measured values of the recorder may be affected by the following factors:

Temperature error:
The stable time in the measurement environment is too short; Close to heat sources, cold sources, or directly exposed to sunlight.

Humidity error
The stable time in the measurement environment is too short; Long term exposure to steam, water mist, water curtains, or condensation environments.

Contaminated
Being in a dusty or other polluted environment

  • If the sensor is found to be blocked or contaminated, it should be wiped with a dust-free cloth dipped in clean water. It is strictly prohibited to use high molecular weight chemical solvents such as alcohol for wiping.
  • If scrapped, it must be strictly handled in accordance with the “Regulations on the Management of Recycling and Disposal of Waste Electrical and Electronic Products”.

FAQs

What should I do if the battery level is less than 20%?

To ensure data reliability, do not enable recording when the battery level is less than or equal to 20%.

How do I know if the device is activated?

Clicking on the activation button and seeing the screen display normally indicates that the device has been activated.

How can I export data from the device?

Connect the device to the computer via USB to generate PDF+CSV format data reports automatically.

Documents / Resources

Elitech Glog 5 Real Time Single Use IoT Data Logger [pdf] User Manual
Glog 5 T, Glog 5 TH, Glog 5 TE, Glog 5 THE, Glog 5 TLE, Glog 5 CO, Glog 5 Real Time Single Use IoT Data Logger, Glog 5, Real Time Single Use IoT Data Logger, Single Use IoT Data Logger, Data Logger, Logger

References

Leave a comment