Logo Elitech

Elitech Glog 5 Real Time Single Use IoT Data Logger

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-product

Présentation du produit

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-1

  1. Back mounted hanging hole
  2. Écran d'affichage LCD
  3. Voyant lumineux à LED
  4. Start stop button
  5. Numéro de série
  6. Capteur de lumière
  7. Power supply+data interface
  8. Capteurs intégrés
  9. Activate/Flight Mode Button
  10. Capteur externe

Écran LCD

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-2

  1. Statut de travail
  2. Description de la fonction
  3. Mode avion
  4. État du signal
  5. Niveau de batterie
  6. Panneaux d'alarme lumineux et vibrants
  7. Time and number of records
  8. Temperature and humidity values

Note: To ensure data reliability, please do not enable recording when the battery level is less than or equal to 20% ( Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-3 between 10% and 20%)

Tableau de sélection

(capteurs de lumière et de vibrations standard)

 

Modèle Type de sonde Plage de mesure Précision
 

Glog 5 T

 

Built in temperature

 

-30℃~70℃

 

±0.5℃

 

Glog 5e

 

Built in temperature and humidity

-30℃~70℃ 0%RH~100%RH ±0.5℃

± 5% HR

 

Glog 5 TE

External temperature+internal temperature  

-40℃~85℃

 

±0.5℃

 

Glog 5 LE

 

External temperature and humidity+internal temperature

External: -40℃~85℃ 0%RH~100%RH

built-in: -30℃~70℃

±0.5℃

± 5% HR

 

Glog 5 TLE

External ultra-low temperature+internal temperature External: -200℃~150℃ built-in: -30℃~70℃ ±0.5℃(-40℃~85℃)

±1℃(-100℃~150℃)

± 2 ℃ (other)

Glog 5 CO₂ External ul-CO₂ & temperature

& humidity built-in temperature

-30℃~70℃ 0%RH~100%RH

0%~100vol%

±0.5℃

± 5% HR

1vol%+3vol% measured

Paramètre technique

Plage de vibrations 0g~16g
Range of illumination intensity 0 ~ 52000Lux
Pouvoir de résolution 0.1 °C/0.1 % HR/0.1 g/1 lux
Clé Conception à double bouton
Voyant lumineux Voyants LED rouges et verts, rouges et bleus
Afficher Broken code display screen
Méthode de positionnement LBS+GPS (optional)
Capacité de stockage 60000 (pre shadow data) 32000 (normal recording+rear shadow data)
Données fantômes Avant+Arrière
intervalle d'enregistrement 1min~24h; Default: 5 minutes
Intervalle de téléchargement 1min~24h adjustable Default: 60 minutes
Méthode de téléchargement des données 4G+2G
Freight initiation method Button, platform, timer
Freight stopping method Button, platform, full memory
Repeat startup 3 times (within the shelf life)
Mode vol Button, timer, electronic fence
Mode alarme Overlimit and low battery
Type de batterie 3.0V disposable lithium manganese battery 4800mAh (CR14505 3B6H)
Mise à niveau OTA Upgrades can be made through data management software and platforms
Niveau d'étanchéité IP65 (intégré)
Environnement de travail -30 ℃~70℃, 0% RH~100% RH (non condensing)
Environnement de stockage 15~30℃,20~75%RH
Spécifications et taille 103 x 61.3 x 30 (mm)
Autonomie de la batterie Record once every 5 minutes in a 25 ℃ environment, upload every 30 minutes, and use the temperature and humidity recorder for a total of 60 days;
Durée de conservation (Usage time+Storage time) 1 year

Paramètre technique

Ajouter un appareil
Plateforme de connexion website: http://www.i-elitech.com, or scan the code to download and install the APP . Register, log in, and add devices according to the prompts.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-4

Activation

Appuyez et maintenez enfoncé le Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5 button for 5s, and the screen will display normally, indicating that the device has been activated.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-6

Note: Clicking on the button and the screen displaying normally indicates that the device has been activated;

Début de l'enregistrement
Appuyez et maintenez enfoncé le Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-7 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-8 symbol, indicating successful startup recording; If theElitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-8indicator flashes, it will enter a delayed countdown state, and after the delay ends, it will automatically start recording;Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-9

Arrêter l'enregistrement

Appuyez et maintenez enfoncé le Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-7 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-10 sign indicating that the recording has been successfully stopped;Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-11

Exportation de données

The device is connected to the computer USB interface through a data cable and will automatically generate PDF+CSV format data reports. You can copy the generated report to your computer for saving.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-12

Note: The keys are invalid during the data export process

Mode vol

  • Activer: Appuyez et maintenez enfoncé le Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-13symbol indicating that the airplane mode has been successfully activated;
  • Fermer: Appuyez et maintenez enfoncé le Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5button for 5s. If the screen Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-13icon disappears, it indicates that the airplane mode has been turned off;

Note: To enable and disable other flight modes, please operate through the platform or app.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-14

Freight Management Operation Instructions

  1. After logging into the platform or app, click on the ‘Freight Management’ menu in the main menu;
  2. Click on the ‘Configuration’ menu on the homepage, and sequentially create and add ‘User Management’, ‘Carrier’, ‘Location’, ‘Alarm Presets’, and’ Freight Template ‘;
  3. Click on the ‘Freight Management’ menu on the homepage to create and manage freight;

Note: For detailed operation manuals, please refer to the operating instructions on the platform or APP;

Description du voyant LED

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-15

Instructions d'affichage à cristaux liquides

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-16

Consignes de sécurité et précautions

Consignes de sécurité

  • Pour garantir une installation et une utilisation correctes de ce produit, veuillez lire et respecter scrupuleusement les conditions suivantes :

Batterie

  • Please use the original battery and do not use other batteries to prevent damage to the equipment or other malfunctions. Do not disassemble, squeeze, hit, or heat the battery privately, and do not place it in a fire, otherwise it may cause battery explosion and fire.

Équipement

  • Do not use this equipment in flammable and explosive gas environments, otherwise it may cause explosions or fires. During the use of the equipment, if the equipment emits a burnt or other odor, the power supply should be immediately cut off and the manufacturer or supplier should be contacted in a timely manner.

Precautions and maintenance requirements

  • If the equipment is not used for a long time, it should be removed and stored in a dry and cool environment in the packaging box.
  • Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may affect the accuracy of the device or even damage it.
  • Do not place the device outdoors for use to avoid instrument short circuits, burns, and other malfunctions caused by adverse weather conditions such as rain and lightning.
  • When the recorder is offline (no data upload), please confirm the networking status of the device;
  • Veuillez utiliser dans la plage de mesure de l'enregistreur
  • Please do not forcefully impact this recorder
  • Sensors should be calibrated regularly to ensure their accuracy meets usage requirements
  • The measured values of the recorder may be affected by the following factors:

Erreur de température :
The stable time in the measurement environment is too short; Close to heat sources, cold sources, or directly exposed to sunlight.

Humidity error
The stable time in the measurement environment is too short; Long term exposure to steam, water mist, water curtains, or condensation environments.

Contaminé
Être dans un environnement poussiéreux ou pollué

  • If the sensor is found to be blocked or contaminated, it should be wiped with a dust-free cloth dipped in clean water. It is strictly prohibited to use high molecular weight chemical solvents such as alcohol for wiping.
  • If scrapped, it must be strictly handled in accordance with the “Regulations on the Management of Recycling and Disposal of Waste Electrical and Electronic Products”.

FAQ

What should I do if the battery level is less than 20%?

To ensure data reliability, do not enable recording when the battery level is less than or equal to 20%.

How do I know if the device is activated?

Clicking on the activation button and seeing the screen display normally indicates that the device has been activated.

How can I export data from the device?

Connect the device to the computer via USB to generate PDF+CSV format data reports automatically.