DAUDIN-LOGO

DAUDIN MELSEC-Q Modbus TCP Connection

DAUDIN MELSEC-Q Modbus TCP Connection-PRODUCT

ʻIke Huahana

Hāʻawi ka 2302EN V2.0.0 a me MELSEC-Q Modbus TCP Connection Operating Manual i nā ʻōlelo aʻoaʻo e pili ana i ka hoʻopili ʻana a me ka hoʻonohonoho ʻana i kahi ʻōnaehana module I/O mamao me ka hoʻohana ʻana i nā ʻāpana like ʻole me kahi ʻīpuka Modbus TCP-to-Modbus RTU/ASCII, kahi mana Master Modbus RTU nui, Digital Input and Output modules, a me nā modules Power Supply. Hoʻohana ʻia ka ʻīpuka ma waho no ka hoʻopili ʻana me MELSEC-Q series 'communication port (Modbus TCP) a ʻo ka mea hoʻokele nui ke kuleana o ka hoʻokele a me ka hoʻonohonoho ikaika o nā ʻāpana I/O a pēlā aku. He kūlana maʻamau ka module mana no nā I/Os mamao a hiki i nā mea hoʻohana ke koho i ke kumu hoʻohālike a i ʻole ka mana o ka module mana a lākou e makemake ai.

Nā ʻōlelo hoʻohana huahana

Papa inoa hoʻonohonoho hoʻonohonoho mamao I/O Module

Hāʻawi ka Papa Hoʻonohonoho Pūnaehana I/O mamao i ka papa inoa o nā modula like ʻole e hiki ke hoʻohana ʻia no ka hoʻonohonoho ʻana i ka ʻōnaehana me ka Gateway, Main Controller, Digital Input and Output modules, a me nā modules Power Supply. Loaʻa i kēlā me kēia module kahi ʻāpana No., Specification, a me ka wehewehe.

ʻO nā hoʻonohonoho ʻana o nā ʻāpana ʻīpuka

Hōʻike ka ʻaoʻao ʻo Gateway Parameter Settings pehea e hoʻopili ai i kahi ʻīpuka i ka moʻo MELSEC-Q. No ka ʻike kikoʻī e pili ana i kēia mau hoʻonohonoho, e ʻoluʻolu e nānā i ka Series Product Manual.

Hoʻonohonoho Polokalamu i-Designer

  1. E hōʻoia i ka mana o ka module a pili i ka module gateway me ka hoʻohana ʻana i ke kaula Ethernet.
  2. E wehe i ka polokalamu i-Designer.
  3. E koho i ka M Series Module Configuration.
  4. Kaomi ma ke kiʻikona hoʻonohonoho Module.
  5. E komo i ka ʻaoʻao Hoʻonohonoho Module no ka M-series.
  6. E koho i ke ʻano o ke ʻano ma muli o ka module i hoʻohui ʻia.
  7. Kaomi ma luna o Hoʻohui.
  8. E hoʻonohonoho i ka Gateway Module IP Settings. 'Ōlelo Aʻo: Pono ka IP address ma ka waihona like me ka MELSEC-Q controller.
  9. E hoʻonohonoho i nā ʻano hana o ka Module Gateway. Hoʻomaopopo: E hoʻonoho i ka Pūʻulu 1 ma ke ʻano he Kauā a hoʻonohonoho i ka ʻīpuka e hoʻohana i ka hoʻonohonoho mua o ke awa RS485 e hoʻopili ai i ka mea hoʻokele nui (GFMS-RM01N).

MELSEC-Q moʻo hoʻonohonoho hoʻohui

ʻO ka MELSEC-Q series Connection Setup mokuna e wehewehe i ka hoʻohana ʻana i ka polokalamu GX Works2 e hoʻohana i ka module QJ71MT91 e hoʻohui i ka moʻo MELSEC-Q i kahi module puka a hoʻohui i kahi module I/O mamao. No ka ʻike kikoʻī, e ʻoluʻolu e nānā i ka MELSEC-Q Series Manual.

MELSEC-Q moʻo Nā Hoʻohui Lako

  1. Aia ke awa Ethernet o ka module QJ71MT91 ma kona kikowaena lalo a hiki ke hoʻopili ʻia i ka ʻīpuka.

MELSEC-Q moʻo IP Address a me ka hoʻonohonoho pili

  1. E hoʻolele i ka GX Works 2 a kaomi ʻākau ma ka papa kuhikuhi Intelligent Function Module ma lalo o Project ma ka ʻaoʻao hema.
  2. Kaomi ma luna o New Module e hana i ka QJ71MB91 module.

Papa inoa hoʻonohonoho hoʻonohonoho mamao I/O Module

Mahele No. Hōʻike wehewehe
GFGW-RM01N  

Modbus TCP-to-Modbus RTU/ASCII, 4 mau Awa

ʻīpuka
GFMS-RM01S Master Modbus RTU, 1 Awa Luna Nui
GFDI-RM01N Hoʻokomo Kikohoʻe 16 Kanal Hoʻokomo hoʻokomo uila
GFDO-RM01N Puke Kikohoʻe 16 Kanal / 0.5A Hōʻailona Kūpono
GFPS-0202 Mana 24V / 48W Lako ikehu
GFPS-0303 Mana 5V / 20W Lako ikehu

Hōʻike huahana

I. Hoʻohana ʻia ka ʻīpuka ma waho e hoʻopili me MELSEC-Q series' port communication (Modbus TCP)
II. ʻO ka mea hoʻoponopono nui ke kuleana o ka hoʻokele a me ka hoʻonohonoho ikaika o nā ʻāpana I / O a pēlā aku.
III. He kūlana maʻamau ka module mana no nā I/Os mamao a hiki i nā mea hoʻohana ke koho i ke kumu hoʻohālike a i ʻole ka mana o ka module mana a lākou e makemake ai.

ʻO nā hoʻonohonoho ʻana o nā ʻāpana ʻīpuka

Hōʻike kēia ʻāpana i ka hoʻopili ʻana i kahi ʻīpuka i ka moʻo MELSEC-Q. No ka ʻike kikoʻī DAUDIN MELSEC-Q Modbus TCP Connection-FIG1, e ʻoluʻolu e nānā i kaDAUDIN MELSEC-Q Modbus TCP Connection-FIG1 Papa Hana Huahana

Hoʻonohonoho Papahana Hoʻolālā

  1. E hōʻoia i ka mana o ka module a pili i ka module gateway me ka hoʻohana ʻana i ke kaula EthernetDAUDIN MELSEC-Q Modbus TCP Connection-FIG2
  2. Kaomi e hoʻomaka i ka polokalamuDAUDIN MELSEC-Q Modbus TCP Connection-FIG3
  3. E koho i ka "M Series Module Configuration"DAUDIN MELSEC-Q Modbus TCP Connection-FIG4
  4. Kaomi ma ka ikona "Setting Module".DAUDIN MELSEC-Q Modbus TCP Connection-FIG5
  5. E komo i ka ʻaoʻao "Setting Module" no ka M-seriesDAUDIN MELSEC-Q Modbus TCP Connection-FIG6
  6. E koho i ke ʻano o ke ʻano ma muli o ka module i hoʻohui ʻiaDAUDIN MELSEC-Q Modbus TCP Connection-FIG7
  7. Kaomi ma ka "Connect"Note: Pono ka IP address ma ka waihona like me ka MELSEC-Q controllerDAUDIN MELSEC-Q Modbus TCP Connection-FIG8
  8. Hoʻonohonoho IP Module GatewayDAUDIN MELSEC-Q Modbus TCP Connection-FIG9Nānā: Pono ka helu IP ma ka waihona like me ka mea hoʻoponopono MELSEC-Q
  9. ʻO nā ʻano hana o ka Gateway ModuleDAUDIN MELSEC-Q Modbus TCP Connection-FIG10

Nānā: E hoʻonoho i ka Pūʻulu 1 ma ke ʻano he Kauā a hoʻonohonoho i ka ʻīpuka e hoʻohana i ka hoʻonohonoho mua o ke awa RS485 e hoʻopili ai i ka mea hoʻokele nui (GFMS-RM01N)

MELSEC-Q moʻo hoʻonohonoho hoʻohui

Hōʻike kēia mokuna pehea e hoʻohana ai i ka polokalamu GX Works2 e hoʻohana i ka module QJ71MT91 e hoʻohui i ka moʻo MELSEC-Q i kahi module puka a hoʻohui i kahi module I/O mamao. No ka ʻike kikoʻī, e ʻoluʻolu e nānā i ka "MELSEC-Q Series Manual

MELSEC-Q moʻo Nā Hoʻohui Lako

  1. Aia ke awa Ethernet o ka module QJ71MT91 ma kona kikowaena lalo a hiki ke hoʻopili ʻia i ka ʻīpukaDAUDIN MELSEC-Q Modbus TCP Connection-FIG11

MELSEC-Q moʻo IP Address a me ka hoʻonohonoho pili

  1. E hoʻokuʻu i ka GX Works 2 a kaomi pololei ma ka papa kuhikuhi "Intelligent Function Module" ma lalo o "Project" ma ka ʻaoʻao hema. A laila kaomi i ka "Module Hou" e hana i kahi module "QJ71MB91".DAUDIN MELSEC-Q Modbus TCP Connection-FIG12
  2. E hoʻolele i ka GX Works 2 a koho i ka papa kuhikuhi "Intelligent Function Module" ma lalo o "Project" ma ka ʻaoʻao hema. A laila kaomi i ka "Switch Setting" ma ka papa kuhikuhi "QJ71MT91".DAUDIN MELSEC-Q Modbus TCP Connection-FIG13
  3. E hoʻonoho i ka "IP Address" i ka waihona like me ka domain gateway ma 192.168.1.XXX.DAUDIN MELSEC-Q Modbus TCP Connection-FIG14
  4. Kaomi ma ka "Automatic_Communication_Parameter" e hoʻonohonoho i nā ʻano heluhelu a me ke kākau ʻanaDAUDIN MELSEC-Q Modbus TCP Connection-FIG15
  5. Kaomi ma ka "Auto_Refresh" e hoʻonohonoho i ka papa inoa o loko no ka heluhelu a me ke kākau ʻanaDAUDIN MELSEC-Q Modbus TCP Connection-FIG16

Hōʻike papahana maʻalahi me ka hoʻohana ʻana i ka moʻo MELSEC-Q a DAUDIN MELSEC-Q Modbus TCP Connection-FIG1

ʻO ka DAUDIN MELSEC-Q Modbus TCP Connection-FIG1'O ka helu helu helu helu helu 'ana he 4096, 'o ia ka D0 no ka papa inoa o loko o ka mea ho'oponopono.
A ʻo ka DAUDIN MELSEC-Q Modbus TCP Connection-FIG1ʻO 8192 ka helu helu kākau inoa, ʻo ia ʻo D300 no ka papa inoa kūloko o ka mea hoʻoponopono.
No laila, inā makemake ʻoe e hoʻomalu i ka papahana, hiki iā ʻoe ke hoʻohana wale i ka papa inoa kūloko e hoʻomalu i ke kākau a me ka heluhelu.

DAUDIN MELSEC-Q Modbus TCP Connection-FIG17

Palapala / Punawai

DAUDIN MELSEC-Q Modbus TCP Connection [pdf] Palapala Hoʻohana
MELSEC-Q Modbus TCP Connection, MELSEC-Q, Modbus TCP Connection, Modbus

Nā kuhikuhi

Waiho i kahi manaʻo

ʻAʻole e paʻi ʻia kāu leka uila. Hōʻailona ʻia nā kahua i makemake ʻia *