2302EN V2.0.0 da MELSEC-Q Modbus TCP Connection Operating Manual yana ba da umarni kan yadda ake haɗawa da daidaita tsarin tsarin I/O mai nisa ta amfani da abubuwa daban-daban ciki har da Modbus TCP-to-Modbus RTU/ASCII ƙofar, babban Modbus RTU. mai sarrafawa, Digital Input and Output modules, and Power Supply modules. Ana amfani da ƙofa a waje don haɗawa tare da tashar sadarwa ta MELSEC-Q jerin' tashar sadarwa (Modbus TCP) kuma babban mai kulawa yana kula da gudanarwa da daidaitawar sigogi na I / O da sauransu. Tsarin wutar lantarki daidaitaccen tsari ne don I/Os mai nisa kuma masu amfani za su iya zaɓar samfuri ko alamar ƙirar wutar lantarki da suka fi so.

Umarnin Amfani da samfur

Jerin Kanfigareshan Tsarin Module I/O mai nisa

Jerin Kanfigareshan Tsarin Module na I/O mai nisa yana ba da jerin nau'ikan nau'ikan nau'ikan nau'ikan da za a iya amfani da su don saita tsarin da suka haɗa da Ƙofar Kofa, Main Controller, Digital Input and Output modules, and Power Supply modules. Kowane module yana da Sashe A'a, Ƙayyadaddun bayanai, da Bayani.

Saitunan Sigar Ƙofar

Sashen Saitunan Ƙofar Ƙofar Ƙofa yayi cikakken bayanin yadda ake haɗa ƙofa zuwa jerin MELSEC-Q. Don cikakkun bayanai game da waɗannan saitunan, da fatan za a koma zuwa Jagoran Samfura.

Saitin Shirin i-Designer

  1. Tabbatar cewa module ɗin yana da ƙarfi kuma an haɗa shi zuwa tsarin ƙofa ta amfani da kebul na Ethernet.
  2. Kaddamar da i-Designer software.
  3. Zaɓi Kanfigareshan Module M Series.
  4. Danna gunkin Saitin Module.
  5. Shigar da shafin Saitin Module don M-jerin.
  6. Zaɓi nau'in yanayin bisa tsarin haɗin da aka haɗa.
  7. Danna Haɗa.
  8. Saita Saitunan IP na Ƙofar Module. Lura: Dole ne adireshin IP ya kasance cikin yanki ɗaya da mai sarrafa MELSEC-Q.
  9. Tsaya Module na Ƙofar Ƙofar Ayyuka. Lura: Saita Rukuni na 1 azaman Bawa kuma saita ƙofa don amfani da saitin farko na tashar RS485 don haɗawa zuwa babban mai sarrafawa (GFMS-RM01N).

MELSEC-Q jerin Haɗin Saitin

Babin Saitin Haɗin Haɗin MELSEC-Q yana bayanin yadda ake amfani da shirin GX Works2 don amfani da tsarin QJ71MT91 don haɗa jerin MELSEC-Q zuwa ƙirar ƙofa da ƙara ƙirar I/O mai nisa. Don cikakkun bayanai, da fatan za a koma zuwa Littafin Jagorar MELSEC-Q.

MELSEC-Q jerin Haɗin Hardware

  1. Tashar tashar Ethernet ta module QJ71MT91 tana tsakiyar tsakiyarta kuma ana iya haɗa ta da ƙofar.

MELSEC-Q jerin adireshin IP da Saitin Haɗin

  1. Kaddamar da GX Works 2 kuma danna-dama akan menu na Module Aiki na hankali ƙarƙashin Project a gefen hagu.
  2. Danna Sabon Module don ƙirƙirar ƙirar QJ71MB91.

Jerin Kanfigareshan Tsarin Module I/O mai nisa

Bangaren No. Ƙayyadaddun bayanai Bayani
GFGW-RM01N  

Modbus TCP-zuwa-Modbus RTU/ASCII, Tashoshi 4

Gateway
GFMS-RM01S Jagora Modbus RTU, 1 Port Babban Mai Gudanarwa
GFDI-RM01N Digital Input 16 Channel Input dijital
GFDO-RM01N Fitar Dijital 16 Channel / 0.5A Fitowar Dijital
Farashin 0202 Ƙarfin wutar lantarki 24V / 48W Tushen wutan lantarki
Farashin 0303 Ƙarfin wutar lantarki 5V / 20W Tushen wutan lantarki

Bayanin Samfura

I. Ana amfani da ƙofar waje don haɗawa da tashar sadarwa ta MELSEC-Q (Modbus TCP)
II. Babban mai sarrafawa yana kula da gudanarwa da kuma daidaitawa na sigogi na I / O da sauransu.
III. Tsarin wutar lantarki daidaitaccen tsari ne don I/Os mai nisa kuma masu amfani za su iya zaɓar samfuri ko alamar ƙirar wutar lantarki da suka fi so.

Saitunan Sigar Ƙofar

Wannan sashin yayi cikakken bayanin yadda ake haɗa ƙofa zuwa jerin MELSEC-Q. Don cikakkun bayanai DAUDIN MELSEC-Q Modbus TCP Connection-FIG1, don Allah koma zuwaDAUDIN MELSEC-Q Modbus TCP Connection-FIG1 Jagoran Samfurin Jerin

Saitin Shirin Zane

  1. Tabbatar cewa module ɗin yana da ƙarfi kuma an haɗa shi zuwa tsarin ƙofa ta amfani da kebul na EthernetDAUDIN MELSEC-Q Modbus TCP Connection-FIG2
  2. Danna don ƙaddamar da softwareDAUDIN MELSEC-Q Modbus TCP Connection-FIG3
  3. Zaɓi "Tsarin Tsarin Module M Series"DAUDIN MELSEC-Q Modbus TCP Connection-FIG4
  4. Danna kan gunkin "Setting Module".DAUDIN MELSEC-Q Modbus TCP Connection-FIG5
  5. Shigar da shafin "Saiti Module" don M-jerinDAUDIN MELSEC-Q Modbus TCP Connection-FIG6
  6. Zaɓi nau'in yanayin bisa tsarin haɗin da aka haɗaDAUDIN MELSEC-Q Modbus TCP Connection-FIG7
  7. Danna "Haɗa" Lura: Dole ne adireshin IP ya kasance a cikin yanki ɗaya da mai sarrafa MELSEC-Q.DAUDIN MELSEC-Q Modbus TCP Connection-FIG8
  8. Saitunan IP na Ƙofar ModuleDAUDIN MELSEC-Q Modbus TCP Connection-FIG9Lura: Dole ne adireshin IP ya kasance cikin yanki ɗaya da mai sarrafa MELSEC-Q
  9. Hanyoyin Aiki na Ƙofar ModuleDAUDIN MELSEC-Q Modbus TCP Connection-FIG10

Lura: Saita Rukuni 1 azaman Bawa kuma saita ƙofa don amfani da saitin farko na tashar RS485 don haɗawa zuwa babban mai sarrafawa (GFMS-RM01N)

MELSEC-Q jerin Haɗin Saitin

Wannan babin yana bayanin yadda ake amfani da shirin GX Works2 don amfani da tsarin QJ71MT91 don haɗa jerin MELSEC-Q zuwa tsarin ƙofa da ƙara ƙirar I/O mai nisa. Don cikakkun bayanai, da fatan za a koma zuwa “MELSEC-Q Series Manual

MELSEC-Q jerin Haɗin Hardware

  1. Tashar tashar Ethernet ta module QJ71MT91 tana tsakiyar tsakiyarta kuma ana iya haɗa ta da ƙofarDAUDIN MELSEC-Q Modbus TCP Connection-FIG11

MELSEC-Q jerin adireshin IP da Saitin Haɗin

  1. Kaddamar da GX Works 2 kuma danna dama akan menu "Module Aiki Mai Hankali" a ƙarƙashin "Project" a gefen hagu. Sannan danna "Sabon Module" don ƙirƙirar tsarin "QJ71MB91".DAUDIN MELSEC-Q Modbus TCP Connection-FIG12
  2. Kaddamar da GX Works 2 kuma zaɓi menu "Module Aiki Mai hankali" a ƙarƙashin "Project" a gefen hagu. Sannan danna kan “Switch Setting” a cikin “QJ71MT91” menuDAUDIN MELSEC-Q Modbus TCP Connection-FIG13
  3. Saita "Adireshin IP" zuwa yanki ɗaya da yankin ƙofar a 192.168.1.XXX.DAUDIN MELSEC-Q Modbus TCP Connection-FIG14
  4. Danna "Automatic_Communication_Parameter" don saita hanyoyin karatu da rubutuDAUDIN MELSEC-Q Modbus TCP Connection-FIG15
  5. Danna "Auto_Refresh" don saita rajista na ciki don karatu da rubutuDAUDIN MELSEC-Q Modbus TCP Connection-FIG16

Sauƙaƙan Nunawar Shirin ta amfani da jerin MELSEC-Q da DAUDIN MELSEC-Q Modbus TCP Connection-FIG1

The DAUDIN MELSEC-Q Modbus TCP Connection-FIG1Adireshin rajista na karanta shine 4096, wanda shine D0 don daidaitaccen rajista na cikin mai sarrafawa.
Da kuma DAUDIN MELSEC-Q Modbus TCP Connection-FIG1Adireshin rajista na rubuta shine 8192, wanda shine D300 don daidaitaccen rijistar ciki na mai sarrafawa.
Don haka, lokacin da kuke son sarrafa shirin, zaku iya amfani da rajistar cikin gida kawai don sarrafa rubutu da karatu.